• Title/Summary/Keyword: Compatibility condition

Search Result 240, Processing Time 0.023 seconds

Design Approach for Boundary Element of Flexure-Governed RC Slender Shear Walls Based on Displacement Ductility Ratio (휨 항복형 철근콘크리트 전단벽의 경계요소설계를 위한 변위연성비 모델제시)

  • Mun, Ju-Hyun;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.687-694
    • /
    • 2014
  • This study established a displacement ductility ratio model for ductile design for the boundary element of shear walls. To determine the curvature distribution along the member length and displacement at the free end of the member, the distributions of strains and internal forces along the shear wall section depth were idealized based on the Bernoulli's principle, strain compatibility condition, and equilibrium condition of forces. The confinement effect at the boundary element, provided by transverse reinforcement, was calculated using the stress-strain relationship of confined concrete proposed by Razvi and Saatcioglu. The curvatures corresponding to the initial yielding moment and 80% of the ultimate state after the peak strength were then conversed into displacement values based on the concept of equivalent hinge length. The derived displacement ductility ratio model was simplified by the regression approach using the comprehensive analytical data obtained from the parametric study. The proposed model is in good agreement with test results, indicating that the mean and standard deviation of the ratios between predictions and experiments are 1.05 and 0.19, respectively. Overall, the proposed model is expected to be available for determining the transverse reinforcement ratio at the boundary element for a targeted displacement ductility ratio.

Experimental Performance Evaluation on V-shaped Butt Welding Using GMA Welding Double Wire Reel and Remote Control Torch Welding Technique (GMAW 더블 와이어 릴, 원격제어토치 용접기술을 이용한 V형 맞대기 용접 부의 실험적 성능 평가)

  • Kim, Jeong-Hyeok;Oh, Seck-Hyeog;Lee, Hae-Gil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1339-1347
    • /
    • 2015
  • This study discusses a remote control torch system equipped with a GMAW double wire reel. The welding machine is 30m away from the wire feeder at the industrial site and the feeder is three to five meters away from the torch. Accordingly, the welders cannot control the current and voltage that meets the welding condition during work when they are working at a place that prevents them from seeing the control panel, such as inside a vehicle or tank or at a far work site. They also have no choice but to stop working to change the wire reel when it is burned out completely. Such work suspension resulting from frequent moves to adjust the current and voltage as well as to replace the wire and subsequent cooling causes welding defects. This study produced a remote control torch equipped with a double wire reel by simplifying and streamlining the existing GMAW functions to reduce the troubling issue. The remote control torch equipped with a double wire reel and the existing $CO_2$ /MAG welding torch were applied as a V-groove butt in the vertical position using 6mm rolled steel for a SM50A welding structure. After welding, the condition of welded surface beads underwent a visual inspection and radiographic inspection to analyze the welding quality inside the welded part. This study also evaluated the reduction of welding defects, cost saving, the replacing performance against the existing commercial welders, and the effects on possible compatibility.

A Simple Numerical Procedure for Assessing the Effect of Ground Improvement Around a Circular Tunnel Excavated in Mohr-Coulomb Rock Mass (Mohr-Coulomb 암반에 굴착된 원형터널의 보강효과 해석을 위한 간편 수치해석법)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2008
  • When a tunnel is excavated in a rock mass of poor condition, the adjacent zone of excavation surface may be reinforced by adopting the appropriate methods such as grouting and rock bolting. The reinforced effect can be evaluated by use of various numerical approaches, where the reinforcing elements may be expressed as distinct discretizations or smeared into the equivalent material properties. In this study, a simple numerical method, which can be classified as the latter approach, was developed for the elasto-plastic analysis of a circular tunnel. If a circular tunnel in a Mohr-Coulomb rock mass is reinforced to a finite thickness, the reinforced annulus may have different material properties from the in-situ rock mass. In the proposed elasto-plastic method for assessing the reinforcing effect, Lee & Pietruszczak (2007)'s method is applied to both the reinforced annulus and the outer insitu rock mass of the fictitious tunnel, and then two results are combined by enforcing the compatibility condition. The method were verified through comparing the results with the proposed method and the commercial finite difference code FLAC. When taking the variation of deformation modulus and strength parameters in the reinforced zone into account, the distributions of stress and radial displacement were much different from those obtained with the assumption of homogeneous rock mass.

Joint Rate Control Scheme for Terrestrial Stereoscopic 3DTV Broadcast (스테레오스코픽 3차원 지상파 방송을 위한 합동 비트율 제어 연구)

  • Chang, Yongjun;Kim, Munchurl
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.14-17
    • /
    • 2010
  • Following the proliferation of three-dimensional video contents and displays, many terrestrial broadcasting companies prepare for starting stereoscopic 3DTV service. In terrestrial stereoscopic broadcast, it is a difficult task to code and transmit two video sequences while sustaining as high quality as 2DTV broadcast attains due to the limited bandwidth defined by the existing digital TV standards such as ATSC. Thus, a terrestrial 3DTV broadcasting system with heterogeneous video coding systems is considered for terrestrial 3DTV broadcast where the left image and right images are based on MPEG-2 and H.264/AVC, respectively, in order to achieve both high quality broadcasting service and compatibility for the existing 2DTV viewers. Without significant change in the current terrestrial broadcasting systems, we propose a joint rate control scheme for stereoscopic 3DTV service. The proposed joint rate control scheme applies to the MPEG-2 encoder a quadratic rate-quantization model which is adopted in the H.264/AVC. Then the controller is designed for the sum of two bit streams to meet the bandwidth requirement of broadcasting standards while the sum of image distortions is minimized by adjusting quantization parameter computed from the proposed optimization scheme. Besides, we also consider a condition on quality difference between the left and right images in the optimization. Experimental results demonstrate that the proposed bit rate control scheme outperforms the rate control method where each video coding standard uses its own bit rate control algorithm in terms of minimizing the mean image distortion as well as the mean value and the variation of absolute image quality differences.

  • PDF

Evaluation of the Cytotoxicity and Mechanical Strength of Dental Duplex Stainless Steel Orthodontic Wire (치과 교정용 듀플렉스 스테인리스 스틸 와이어의 기계적 강도 및 세포독성 평가)

  • Lee, Myung-Kon;Kim, Chi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.309-317
    • /
    • 2010
  • The stainless steel wire is extensively used for the orthodontic treatment. But, the stainless steel wire that has commonly superior corrosion resistance has caused hypersensitive reaction or allergy as side effects because of corrosion in the oral environment. For improving the problem of corrosion, we was evaluated the suitability of the duplex stainless steel(DSS) as orthodontic wire through this study. The DSS wire was evaluated the mechanical strength and bio-stability for suitability and bio-compatibility as orthodontic wire. In this work, the DSS and stainless steel(SS) as common use of medical grade were prepared for the tensile strength test. The DSS wire were treated by heat. and Temperature conditions of the heat treatment were $28^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$, $800^{\circ}C$, $900^{\circ}C$, respectively. And the DSS wires that treated by heat on the optimum temperature condition were conducted the bending moment test and calculated the S-Max value and the modulus of elasticity. For evaluating the bio stability, each materials were conducted in vitro test for measuring the cell survival rate. The most interesting results was that the tensile strength test of SS wire($8.17\times10^4\;N/mm^2$) and DSS wire($8.05\times10^4\;N/mm^2$) that treated at $500^{\circ}C$ by heat were similar in mechanical strength. In the bio-stability study, the DSS has no cytotoxicity (p=0.05) Thus, we could make a conclusion that the duplex stainless steel wire has vastly superior corrosion resistance was suitable as orthodontic wire.

Characteristics of Low Dielectric Constant SiOF Thin Films with Post Plasma Treatment Time (플라즈마 후처리 시간에 따른 저유전율 SiOF 박막의 특성)

  • Lee, Seok Hyeong;Park, Jong Wan
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.3
    • /
    • pp.267-267
    • /
    • 1998
  • The fluorine doped silicon oxide (SiOF) intermetal dielectric (IMD) films have been of interest due to their lower dielectric constant and compatibility with existing process tools. However instability issues related to bond and increasing dielectric constant to water absorption when the SiOF films was exposured to atmospheric ambient. Therefore, the purpose of this research is to study the effect of post oxygen plasma treatment on the resistance of moisture absorption and reliability of SiOF film. Improvement of moisture absorption resistance of SiOF film is due to the forming of thin SiO₂layer at the SiOF film surface. It is thought that the main effect of the improvement of moisture absorption resistance was densification of the top layer and reduction in the number of Si-F bonds that tend to associate with OH bonds. However, the dielectric constant was increased when plasma treatment time is above 5 min. In this study, therefore, it is thought that the proper plasma treatment time is 3 min when plasma treatment condition is 700 W of microwave power, 3 mTorr of process pressure and 300℃ of substrate temperature.

A Study on the Nurse's Recognition and Performance in Intravenous Therapy Management (간호사의 정맥주사 관리에 대한 인식과 수행에 관한 연구)

  • Kim Myung-Hee;Kim Youn-Hwa
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.207-224
    • /
    • 1998
  • The purposes of this study were to identify nurse's recognition and performance and to represent the factors of hindrance in the IV therapy management. The subjects were 420 nurses who worked at five general hospitals in Pusan. Tha data were collected using a questionnaire and the period of data collection was from January 1 to January 31, 1998. The instrument for this study was made by author oneself on the basis of guidelines Simmons et al', CDC' Stanley' and Kurdi' guideline, Cllinical Nurse's Association' that consist of 68 items for 5 fields ; pre-injection, just before-injection, needle-injection, during injection, post-injection field. Cron-bach Alpha coefficient of recognition and performance in the IV therapy management was .93 and .87. The datas were analized by a SPSS program using frequency, percent, paired t-test, t-test and oneway ANOVA. The results obtained were as follows : 1. The mean score of recognition in IV therapy management was significantly higher than that of performance(t=5.86, P<.001). 2. The items of lower than mean score of each fields in performance were the identification of drugs, hands washing, patient teaching about medication, disinfectional methods of the injection site and the rubber stopper in bottle, the use of disposable gloves, mask and eye goggles at the chemotherapy preparation, use of tape and armboard, changing the IV tubing, labeling the dressing over the injection site, observation and recordings of patient's condition after medication and confirmation of the needle length at the needle removal. 3. The factors of hindrance in IV therapy were 'having no time', 'insufficiency of goods', 'unknowing of methods', 'no disadvantage', and 'factors of doctor's doing'. The most important factor was 'have no time', especially item of hands washing. The other factors of hindrance showed high frequency in the following items ; 'insufficiency of goods' in the use of disposable gloves, mask and eye goggles at the chemotherapy preparation, 'unknowing of methods' in the certification of drugs compatibility, 'no disadvantage' in the labeling the dressing over the injection site, and 'factors of doctor's doing' in the changing the subclavian catheter dressing and checking the glucose level during the TPN infusion. In conclusion, there is necessity of educational program which can improve the nurse's knowledge of drugs, disinfection methods, comfort of patient and recordings in IV therapy management and alternative plan which are political and financial aids such as setting up the sink, giving of paper towels and necessary goods in the IV therapy for reducing the factors of hindrance for IV therapy management.

  • PDF

Chemical Treatment of Leachate from Swine Manure Composting System (양돈분뇨 퇴비화공정에서 발생하는 침출액의 화학적처리)

  • 정태영;오인환;김동수
    • Journal of Animal Environmental Science
    • /
    • v.8 no.3
    • /
    • pp.145-152
    • /
    • 2002
  • This experiment was conducted to investigate the efficiency and compatibility of the coagulation and settling processes of leachates from the compost of two swine farms. And results obtained are as follows : 1 In the farm A where $COD_{Cr}$, $COD_{Mn}$ and $BOD_5$ of original leachate were 4,400, 2,950 and 87mg/l, respectively, the rate of coagulation and settling process was more efficient in the leachate treated with the conjugate of Alum and cation polymer than that of Alum and anion polymer. The concentrations of BOD$_{5}$, T-N and T-P of the effluent after treatment with the conjugate of Alum and cation polymer under the optimum condition were 19, 257.5 and 0.4mg/l, respectively which are under the governmental regulation level. 2. In the farm B where $COD_{Cr}$, $COD_{Mn}$ and $BOD_5$ of original leachate were 4,720, 3,040 and 95mg/l, respectively, the conjugate of $FeCl_3$, 1,500mg/l and cation polymer 10mg/l ($FeCl_3$+FO4240) was most effective coagulation and settling agent compared with the others. The concentrations of BOD$_{5}$, T-N and T-P of the effluent after treatment with $FeCl_3$+FO4240 were 15.3, 829.4 and 2.8mg/l, respectively. And the concentration of T-N was higher than the governmental regulation level, presumably because of too high concentration of NH$_4$$^{+}$-N in the leachate.

  • PDF

Specific Primer Sets for RT-PCR Detection of Major RNA Viruses of Tomato Plants in Korea (국내의 토마토 주요 바이러스 진단을 위한 역전사중합반응법용 프라이머 세트)

  • Shin, Jun-Sung;Han, Jung-Heon;Shin, Yu-Ju;Kwak, Hae-Ryun;Choi, Hong-Soo;Kim, Jeong-Soo
    • Research in Plant Disease
    • /
    • v.23 no.2
    • /
    • pp.193-201
    • /
    • 2017
  • Major tomato viruses in Korea are Tomato chlorosis virus (ToCV), Tomato spotted wilt virus (TSWV), Cucumber mosaic virus (CMV), Pepper mottle virus (PepMoV), and Tomato mosaic virus (ToMV). RT-PCR conditions for the viruses were examined, especially in primer set and RT-PCR mixture. Total 46 primer sets from the unique sequence of the viruses were tested for nonspecific background products in a RT-PCR mixture without template. Among them 16 primer sets were applied to healthy tomato RNA, resulting the compatibility between RT-PCR mixture and primer set influenced RT-PCR to reduce nonspecific background products. Based on the combinations among cDNA synthesis parameters and RT-PCR mixtures, two reaction mixtures were finally selected for ToCV detection. The condition allowed to determine more specific primer sets; C029 (ToCV), C072 (TSWV), C070 (CMV), C048 (PepMoV), and C065 (ToMV). These primer sets are expected to be of use to specific detection of the major viruses in tomato plants.

Novel Graphene Volatile Memory Using Hysteresis Controlled by Gate Bias

  • Lee, Dae-Yeong;Zang, Gang;Ra, Chang-Ho;Shen, Tian-Zi;Lee, Seung-Hwan;Lim, Yeong-Dae;Li, Hua-Min;Yoo, Won-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.120-120
    • /
    • 2011
  • Graphene is a carbon based material and it has great potential of being utilized in various fields such as electronics, optics, and mechanics. In order to develop graphene-based logic systems, graphene field-effect transistor (GFET) has been extensively explored. GFET requires supporting devices, such as volatile memory, to function in an embedded logic system. As far as we understand, graphene has not been studied for volatile memory application, although several graphene non-volatile memories (GNVMs) have been reported. However, we think that these GNVM are unable to serve the logic system properly due to the very slow program/read speed. In this study, a GVM based on the GFET structure and using an engineered graphene channel is proposed. By manipulating the deposition condition, charge traps are introduced to graphene channel, which store charges temporarily, so as to enable volatile data storage for GFET. The proposed GVM shows satisfying performance in fast program/erase (P/E) and read speed. Moreover, this GVM has good compatibility with GFET in device fabrication process. This GVM can be designed to be dynamic random access memory (DRAM) in serving the logic systems application. We demonstrated GVM with the structure of FET. By manipulating the graphene synthesis process, we could engineer the charge trap density of graphene layer. In the range that our measurement system can support, we achieved a high performance of GVM in refresh (>10 ${\mu}s$) and retention time (~100 s). Because of high speed, when compared with other graphene based memory devices, GVM proposed in this study can be a strong contender for future electrical system applications.

  • PDF