• Title/Summary/Keyword: Compatibility

Search Result 3,157, Processing Time 0.031 seconds

Dual Codec Based Joint Bit Rate Control Scheme for Terrestrial Stereoscopic 3DTV Broadcast (지상파 스테레오스코픽 3DTV 방송을 위한 이종 부호화기 기반 합동 비트율 제어 연구)

  • Chang, Yong-Jun;Kim, Mun-Churl
    • Journal of Broadcast Engineering
    • /
    • v.16 no.2
    • /
    • pp.216-225
    • /
    • 2011
  • Following the proliferation of three-dimensional video contents and displays, many terrestrial broadcasting companies have been preparing for stereoscopic 3DTV service. In terrestrial stereoscopic broadcast, it is a difficult task to code and transmit two video sequences while sustaining as high quality as 2DTV broadcast due to the limited bandwidth defined by the existing digital TV standards such as ATSC. Thus, a terrestrial 3DTV broadcasting with a heterogeneous video codec system, where the left image and right images are based on MPEG-2 and H.264/AVC, respectively, is considered in order to achieve both high quality broadcasting service and compatibility for the existing 2DTV viewers. Without significant change in the current terrestrial broadcasting systems, we propose a joint rate control scheme for stereoscopic 3DTV service based on the heterogeneous dual codec systems. The proposed joint rate control scheme applies to the MPEG-2 encoder a quadratic rate-quantization model which is adopted in the H.264/AVC. Then the controller is designed for the sum of the left and right bitstreams to meet the bandwidth requirement of broadcasting standards while the sum of image distortions is minimized by adjusting quantization parameter obtained from the proposed optimization scheme. Besides, we consider a condition on maintaining quality difference between the left and right images around a desired level in the optimization in order to mitigate negative effects on human visual system. Experimental results demonstrate that the proposed bit rate control scheme outperforms the rate control method where each video coding standard uses its own bit rate control algorithm independently in terms of the increase in PSNR by 2.02%, the decrease in the average absolute quality difference by 77.6% and the reduction in the variance of the quality difference by 74.38%.

A Design and Implementation of Multimedia Retrieval System based on MAF(Multimedia Application File Format) (MAF(Multimedia Application File Format) 기반 멀티미디어 검색 시스템의 설계 및 구현)

  • Gang Young-Mo;Park Joo-Hyoun;Bang Hyung-Gin;Nang Jong-Ho;Kim Hyung-Chul
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.9
    • /
    • pp.574-584
    • /
    • 2006
  • Recently, ISO/IEC 23000 (also known as 'MPEG-A') has proposed a new file format called 'MAF(Multimedia Application File Format)[1]' which provides a capability of integrating/storing the widely-used compression standards for audio and video and the metadata in MPEG-7 form into a single file format. However, it is still very hard to verify the usefulness of MPEG-A in the real applications because there is still no real system that fully implements this standard. In this thesis, a design and implementation of a multimedia retrieval system based on MPEG-A standard on PC and mobile device is presented. Furthermore, an extension of MPEG-A for describing the metadata for video is also proposed. It is selected and defined as a subset of MPEG-7 MDS[4] and TV-anytime[5] for video that is useful and manageable in the mobile environments. In order to design the multimedia retrieval system based on MPEG-A, we define the system requirements in terms of portability, extensibility, compatibility, adaptability, efficiency. Based on these requirements, we design the system which composed of 3 layers: Application Layer, Middleware Layer, Platform Layer. The proposed system consists of two sub-parts, client-part and server-part. The client-part consists of MAF authoring tool, MAP player tool and MAF searching tool which allow users to create, play and search the MAF files, respectively. The server-part is composed of modules to store and manage the MAF files and metadata extracted from MAF files. We show the usefulness of the proposed system by implementing the client system both on MS-Windows platform on desk-top computer and WIPI platform on mobile phone, and validate whether it to satisfy all the system requirements. The proposed system can be used to verify the specification in the MPEG-A, and to proves the usefulness of MPEG-A in the real application.

Analysis of Orthotropic Body under Ultimate Moment Load (극한(極限)모멘트 하중(荷重)을 받는 이방성(異方性) 구조체(構造體)의 해석(解析))

  • Chang, Suk Yoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.3
    • /
    • pp.95-105
    • /
    • 1985
  • This dissertation presents an exact solution for the normal and shearing stresses of an orthotropic plane body loaded by a moment load. The solution satisfies the conditions of equilibrium compatibility equations concurrently and is governing for the body being in the elasto-plastic state. An Airy stress function is introduced to solve the problem related to an orthotropic half-infinite plane under a moment load. All the equations for orthotropy must be degenerated into the expressions for isotropy when orthotropic constants are replaced by isotropic ones. The author has evaluated all the equations of orthotropy and succeeded in obtaining exactly identical expressions to the equations of isotropy which were derived independently by of L'hosptials rule. The analytical results of isotropy are compared with the simple results of other investigator. Since moment Load under the elastic state and plastic state only is a particular case of moment load under the elasto-plastic state. All the equations of elasto-plastic state case are degenerated into the expressions for the each case. The formal solution is expressed in terms of closed form. The orthotropic constants are evaluated for two kinds and two different orientations of the grain of wood and two kinds of structures. The numerical results for orthotropy are evaluated for one kind and two different orientations of three-layered ply wood. The distribution of normal and shearing stresses are shown in figures. It is noted that the distribution of stresses of orthotropic materials depends on the type of materials and orientations of the grain and stiffening.

  • PDF

Electrochemical Decontamination of Metallic Wastes Contaminated with Uranium Compounds (우라늄화합물로 오염된 금속폐기물의 전해제염)

  • 양영미;최왕규;오원진;유승곤
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • A study on the electrolytic dissolution of SUS-304 and Inconel-600 specimen was carried out in neutral salt electrolyte to evaluate the applicability of electrochemical decontamination process for recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant in Korea. Although the best electrolytic dissolution performance for the specimens was observed in a Na2s04 electrolyte, a NaNO$_3$ neutral salt electrolyte, in which about 30% for SUS-304 and the same for Inconel-600 in the weight loss was shown in comparison with that in a Na$_2$SO$_4$ solution, was selected as an electrolyte for the electrochemical decontamination of metallic wastes with the consideration on the surface of system components contacted with nitric acid and the compatibility with lagoon wastes generated during the facility operation. The effects of current density, electrolytic dissolution time, and concentration of NaNO$_3$ on the electrolytic dissolution of the specimens were investigated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as UO$_2$, AUC (ammonium uranyl carbonate) and ADU (ammonium diuranate) taken from an uranium conversion facility were performed in 1M NaNO$_3$ solution with the current density or In mA/$\textrm{cm}^2$. it was verified that the electrochemical decontamination of the metallic wastes contaminated uranium compounds was quite successful in a NaNO$_3$ neutral salt electrolyte by reducing $\alpha$ and $\beta$ radioactivities below the level of self disposal within 10 minutes regardless of the type of contaminants and the degree of contamination.

  • PDF

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.

Analysis of Relativity Between Invasiveness on Chest of Tomographic Finding and Histopathologic Invasiveness (종격동 종양의 전산화 단층촬영(CT)소견, 수술소견 및 병리조직학적 침윤도 사이의 상관성 분석)

  • 김용희;이현우
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.780-785
    • /
    • 1997
  • Mediastinal tumor had been fascinated by its location on heart, great vessels, esophagus, and nervous tissue, its convenience of surgical treatment and superiority of its operative result. Between January 1989 and June 1995, eighty-seven patients with mediastinal tumor which were treated surgically in the Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, School of Medicine, University of Ulsan. To provide the appropriate surgical management of mediastinal tumor, the demographic data, diagnostic evaluation, clinical presentation, location, size, operative finding and histopathologic distribution were reviewed and we analyzed relativity between invasiveness in chest computed tomographic finding or invasiveness on operative finding and histopathologic invasiveness. The anterosuperior mediastinum was the most commonly involved site of a mediastinal tumor(57%), followed by the posterior mediastinum(35%) and middle mediastinum(8%). The most frequently encountered tumors were thymic neoplasia(31%), followed by primary cyst(22%), neurogenic tumor(22%) and teratoma(10%) in decreasing order of frequency. Histopathologically invasive tumors were present in 17 patients(20%) and its site included anterosuperior mediastinum(16%) and posterior mediastinum(4%). All patients in this study underwent chest CT. In chest CT's finding, 15 patients(17%) showed invasiveness. A total excision of the tumor was performed 80 patients(92%), subtotal excision 6 patients(7%) and biopsy only 1 patient(2%). In operative finding, 14 patients(16%) were suspected invasiveness. The mean size of the tumor was 6.0$\pm$ 3.2cm. In anterosuperior mediastinum, the mean size was 6.2$\pm$3.1cm, in middle mediastinum, it was 3.9$\pm$1.1cm, in posterior mediastinum, it was 5.8$\pm$2.6cm. In malignant tumors, the mean size was 7.3$\pm$4.6cm, in benign tumor, it was 5.5$\pm$2.6cm(P<0.05). Relativity between histopathological invasiveness(17 patients) and invasiveness in chest CT's finding(15 patients) included sensitivity 35%, specificity 87% and predictability 35%, relativity between histopathological invasiveness(17 patients) and invasiveness on operative finding included sensitivity 52%, specificity 93% and predictability 64%. In conclusion, since it was proved that the compatibility of preoperative chest CT findings or operative findings and histopathological invasiveness is quite low, it is considered that wide excision of the mediastinal tumor except cystic lesion including adjacent tissues would yield better postoperative results.

  • PDF

The Comparison Evaluation of SUV Using Different CT Devices in PET/CT Scans (PET 검사에서 CT 장비의 차이에 따른 PET/CT의 SUV 비교 평가)

  • Kim, Woo Hyun;Go, Hyeon Soo;Lee, Jeong Eun;Kim, Ho Sung;Ryu, Jae Kwang;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • Purpose: Among different PET/CT devices which are composed of same PET model but different CT models, SUV, usually used for quantitative evaluation, was measured to assess the accuracy of follow up scans in different PET/CT and confirm that interequipment compatibility is useful in arranging the PET/CT exam appointment. Materials and Methods: Using ACR PET Phantom, PET NEMA IEC Body Phantom, SNM Chest Phantom and Ge-68 cylinder Phantom, $SUV_{mean}$ and $SUV_{max}$ was measured by 3 different models of PET/CT (Discovery 690, Discovery 690Elite and Discovery 710, GE) made in same company. ANOVA was used to evaluate the significant difference in the result. Results: In the result, the average of $SUV_{max}$ was D690 (25 mm-1.82, 16 mm-1.75, 12 mm-1.73, 8 mm-1.44), D690E (25 mm-1.76, 16 mm-1.92, 12 mm-1.78, 8 mm-1.55) and D710 (25 mm-1.84, 16 mm-1.89, 12 mm-1.77, 8 mm-1.61) in ACR Phantom, D690 (25 mm-2.26, 16 mm-2.25, 12 mm-1.92, 8 mm-1.85), D690E (25 mm-2.45, 16 mm-2.25, 12 mm-2.05 8 mm-1.91) and D710(25 mm-2.49, 16 mm-2.20, 1 2mm-2.30, 8 mm-2.05) in PET NEMA IEC Body Phantom, D690-1.04, D690E-1.10 and D710-1.09 in SNM Chest Phantom and D690-0.81, D690E-0.81, D710-0.84 in Ge-68 cylinder Phantom. The differences between average SUV of 4 phantoms were $SUV_{mean}$-1.87%, $SUV_{max}$-2.15%. And also as a result of ANOVA analysis, there was no significant difference statistically. Conclusion: If different models of PET/CT have same specification of PET system, there was no significant difference in $SUV_{mean}$ and $SUV_{max}$ even though they have different CT system. And also differences of $SUV_{mean}$ and $SUV_{max}$ in phantom images were under 5% which many manufacturers recommend. Therefore, follow up scan will be possible using different PET/CT if it has same specification of PET system with the previous PET/CT. This information will enable the accurate comparative analysis when conducting follow up scans and be helpful to schedule PET/CT exam more effectively.

  • PDF

Evaluation of Cleaning ability and Environmental Evaluation of Commercial Aqueous/Semi-aqueous Cleaning Agents (시판 수계/준수계 세정제의 세정성 및 환경성 평가 연구)

  • Cha, A.J.;Park, J.N.;Kim, H.S.;Bae, J.H.
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.73-87
    • /
    • 2004
  • In most of industrial fields, cleaning is employed for removing soils on their products or parts. Halogenated cleaning agents such as CFC-113, 1,1,1-TCE(1,1,1-trichloroethane), MC(methylene chloride) and TCE (trichloroethylene) have been used as cleaning ones in most of companies in the world since their excellent performance of cleaning ability and good material compatibility. However, CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of the which are ozone destruction substances are not used any more in the advanced countries because of the Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous/semi-aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. In this study, commercially available 12 aqueous and 6 semi-aqueous cleaning agents were selected and their physical properties, cleaning abilities, rinsing abilities and recycling of contaminated rinse water were measured and analyzed. Aqueous cleaning agents with higher wetting index showed better cleaning ability compared with those with lower wetting index. However wetting index did not have any correlation with cleaning ability in semi-aqueous cleaning agents. It was observed that soil concentration in aqueous and semi-aqueous cleaning agents should be maintained below the certain concentrations which depend on types of clearing agents. More than 70% soils in contaminated rinse water by some of aqueous and semi-aqueous clearing agents could be separated by simple settling method. This means that some cleaning agents with high oil-water separation efficiency will be effiective for recycling oil-contaminated rinse water. It was found that contaminated rinse water with aqueous agents was purified easiy by ultrafiltration method with PAN membrane of 30 kDa.

  • PDF

Effect of Addition of Fractionated Milk Fats on Fat Composition and Melting Behavior of Cocoa Butter (유지방 획분 첨가가 코코아 버터의 지방조성과 용융거동에 미치는 영향)

  • Kim, Sang-Yong;Roh, Hoe-Jin;Oh, Deok-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.482-491
    • /
    • 1997
  • The effect of addition of fractionated milk fats on the composition and melting behavior of cocoa butter was investigated. High melting fraction (HMF) of milk fat fractions had the highest contents of long chain fatty acid $(C16{\sim}C18)$ and saturated fatty acid followed by medium melting fraction 1 (MMF1), medium melting fraction 2 (MMF2), anhydrous milk fat (AMF), and low melting fraction (LMF) in a decreasing order. MMF2 had the highest contents of the short chain fatty acid $(C4{\sim}C10)$ and medium chain fatty acid $(C12{\sim}C14)$ followed by AMF, HMF, MMF1, and LMF in a decreasing order. When the fractionated milk fats were added to cocoa butter, the long chain fatty acid contents increased with increasing the ratio of fractionated milk fats. The saturated fatty acid contents decreased only when the LMF was added. The higher content of long chain triglyceride and the lower contents of short chain triglyceride and medium chain triglyceride were obtained from the fractionated milk fat of higher melting point. When the fractionated milk fats were added to cocoa butter, long chain triglyceride contents decreased with increasing the ratio of the fractionated milk fats. The melting points of cocoa butter, AMF, HMF, MMF1, MMF2, LMF were $33.3^{\circ}C,\;31.2^{\circ}C,\;40.6^{\circ}C,\;37.4^{\circ}C,\;33.5^{\circ}C$, and $6.5^{\circ}C$, respectively. Cocoa butter had the highest content of solid fat followed by HMF, MMF1, MMF2, AMF, and LMF in a decreasing order. When the fractionated milk fat was added to cocoa butter at various temperatures, the solid fat content in the mixture of fractionated milk fat and cocoa butter decreased with increasing the ratio of fractionated milk fat. This results suggested that anhydrous milk fat and fractionated milk fats had a good compatibility with cocoa butter.

  • PDF

Development of Optimum Grip System in Developing Design Tensile Strength of GFRP Rebars (GFRP 보강근의 설계 인장강도 발현을 위한 적정 그립시스템 개발)

  • You Young-Chan;Park Ji-Sun;You Young-Jun;Park Young-Hwan;Kim Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.947-953
    • /
    • 2005
  • Previous test results showed that the current ASTM(American Standard for Testing and Materials) grip adapter for GFRP(Glass Fiber Reinforced Polymer) rebar was not fully successful in developing the design tensile strength of GFRP rebars with reasonable accuracy. It is because the current ASTM grip adapter which is composed of a pair of rectangular metal blocks of which inner faces are grooved along the longitudinal direction does not take into account the various geometric characteristics of GFRP rebar such as surface treatment, shape of bar cross section as well as physical characteristics such as poisson effect, elastic modulus in the transverse direction and so on. The objective of this paper is to provide how to proportion the optimum diameter of inner groove in ASTM grip adapter to develop design tensile strength of GFRP rebar. The proportioning of inner groove in ASTM grip adapter is based on the force equilibrium of GFRP rebar between tensile capacity and minimum frictional resistance required along the grip adapter. The frictional resistance of grip adapter is calculated based on the compressive strain compatibility in radial direction induced by the difference between diameter of GFRP rebar and inner groove In ASTM grip. All testing procedures were made according to the CSA S806-02 recommendations. From the preliminary test results on round-type GFRP rebars, it was found that maximum tensile loads acquired under the same testing conditions is highly affected by the diameter of inner groove in ASTM grip adapter. The grip adapter with specific dimension proportioned by proposed method recorded the highest tensile strength among them.