• Title/Summary/Keyword: Comparison of simulation

Search Result 3,968, Processing Time 0.036 seconds

A simulation comparison on the analysing methods of Likert type data (모의실험에 의한 리커트형 설문분석 방법의 비교)

  • Kim, Hyun Chul;Choi, Seung Kyoung;Choi, Dong Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.2
    • /
    • pp.373-380
    • /
    • 2016
  • Even though Likert type data is ordinal scale, many researchers who regard Likert type data as interval scale adapt as parametric methods. In this research, simulations have been used to find out a proper analysis of Likert type data. The locations and response distributions of five point Likert type data samples having diverse distribution have been evaluated. In estimating samples' locations, we considered parametric method and non-parametric method, which are t-test and Mann-Whitney test respectively. In addition, to test response distribution, we employed Chi-squared test and Kolmogorov-Smirnov test. In this study, we assessed the performance of the four aforementioned methods by comparing Type I error ratio and statistical power.

A Particle Tracking Method for the Lagrangian-Eulerian Finite Element Method in 3-D Subsurface System (3차원 지표하 시스템에서 Lagrangian-Eulerian 유한요소법에 대한 입자추적 알고리즘)

  • Lee, Jae-Young;Kang, Mee-A
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.205-215
    • /
    • 2009
  • The conventional numerical models to analyze flow in subsurface porous media under the transient state usually generate numerical oscillation and unstability due to local flux domain for critical cases such as infiltration into initially dry soil during rainfall period. In this case, it is required refined mesh and small time step, but it decrease efficiency of computation. In this study, numerical unstability in discontinuity domain is removed by applying particle tracking algorithm to simulate unsteady subsurface flow with inflow boundary condition. Finally the hybrid LE FEM improving numerical stability is proposed. The hypothetical domains with unsteady uniform and nonuniform flow field were used to demonstrated algorithm verification. In comparison with analytic solution, we obtained reasonable results and conducted simulation of hypothetical 3-D recharge/pumping area. The proposed algorithm can simulate saturated/unsaturated porous media with more practical problems and will greatly contribute to accuracy and stability of numerical computation.

Energy-Aware Self-Stabilizing Distributed Clustering Protocol for Ad Hoc Networks: the case of WSNs

  • Ba, Mandicou;Flauzac, Olivier;Haggar, Bachar Salim;Makhloufi, Rafik;Nolot, Florent;Niang, Ibrahima
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.11
    • /
    • pp.2577-2596
    • /
    • 2013
  • In this paper, we present an Energy-Aware Self-Stabilizing Distributed Clustering protocol based on message-passing model for Ad Hoc networks. The latter does not require any initialization. Starting from an arbitrary configuration, the network converges to a stable state in a finite time. Our contribution is twofold. We firstly give the formal proof that the stabilization is reached after at most n+2 transitions and requires at most $n{\times}log(2n+{\kappa}+3)$ memory space, where n is the number of network nodes and ${\kappa}$ represents the maximum hops number in the clusters. Furthermore, using the OMNeT++ simulator, we perform an evaluation of our approach. Secondly, we propose an adaptation of our solution in the context of Wireless Sensor Networks (WSNs) with energy constraint. We notably show that our protocol can be easily used for constructing clusters according to multiple criteria in the election of cluster-heads, such as nodes' identity, residual energy or degree. We give a comparison under the different election metrics by evaluating their communication cost and energy consumption. Simulation results show that in terms of number of exchanged messages and energy consumption, it is better to use the Highest-ID metric for electing CHs.

Performance Improvement of Radial Basis Function Neural Networks Using Adaptive Feature Extraction (적응적 특징추출을 이용한 Radial Basis Function 신경망의 성능개선)

  • 조용현
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.3
    • /
    • pp.253-262
    • /
    • 2000
  • This paper proposes a new RBF neural network that determines the number and the center of hidden neurons based on the adaptive feature extraction for the input data. The principal component analysis is applied for extracting adaptively the features by reducing the dimension of the given input data. It can simultaneously achieve a superior property of both the principal component analysis by mapping input data into set of statistically independent features and the RBF neural networks. The proposed neural networks has been applied to classify the 200 breast cancer databases by 2-class. The simulation results shows that the proposed neural networks has better performances of the learning time and the classification for test data, in comparison with those using the k-means clustering algorithm. And it is affected less than the k-means clustering algorithm by the initial weight setting and the scope of the smoothing factor.

  • PDF

A Study on the Nonlinear Resistance Model of a F/L Operating in High Frequency (고주파 점등 형광램프의 비선형 저항 모델에 관한 연구)

  • 지철근;장우진
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.1 no.2
    • /
    • pp.49-56
    • /
    • 1987
  • To save energy consumption, it is proposed to operate a discharge lamp with high frequency power. When designing a high frequency operating circuit containing a discharge lamp, the character of a lamp may be needed. And there are various methods to get and models for this. In this study, to present the volt-ampere character of a fluorescent lamp which gives a good saving effect, the nonlinear resistance model is suggested. And the validity of the model is verified by applying the model for the circuits with inductor ballast and capacifor ballast. This model, in contrast with the others, can be easily obtainable. And for comparison, the model using a modified Francis equation is examined. The method used in this study can be basically applied to the other discharge lamps. As a result, 1) Approximated 3rd order polynomial of nonlinear resistance model gives a good simulation result. 2) When operating in high frequency, the model using a modified Francis equation with constant coefficients can't be applied.

  • PDF

Space-Frequency Block Coded Relay Transmission System for a Shadow Area (음영 지역을 위한 주파수 공간 블록 부호화 중계기 전송 시스템)

  • Won, Hui-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5776-5782
    • /
    • 2014
  • Relay-assisted wireless communication systems have been studied widely to cope with shadow areas and extend the cell coverage. This paper proposes a space-frequency (SF) block coded single carrier-frequency division multiple access (SC-FDMA) transmission system in a relaying multi-path shadow area and present the performance comparison of SC-FDMA systems based on the signal-to-noise power ratio (SNR) between a relay and a destination station. The performance of relaying SC-FDMA systems can be improved by applying SF block code to the recovered signals of relays before re-transmitting them. The simulation result showed that the SNR performance of the proposed SF block coded relaying SC-FDMA system was approximately 5 dB better than the SNR performance of the single-path relaying SC-FDMA system at a symbol error rate (SER) of $10^{-2}$.

Efficient RF Energy Harvesting Algorithm based on Frequency Selective Fading Map (주파수 선택적 페이딩 맵 기반 효율적 무선 에너지 하비스팅 알고리즘)

  • Park, Ji Ho;Hwang, Yu Min;Song, Yu Chan;Kim, Jin Young
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.2
    • /
    • pp.24-29
    • /
    • 2015
  • Recently, with developments of various networks, devices and various services, energy efficiency has become one of the most crucial issues with respect to sustainability of mobile devices. For connecting to networks seamlessly to offer services, a scenario of RF energy harvesting which supplies energy to wireless devices with RF signals is assumed. To increase the efficiency of RF energy harvesting, this paper proposes a RF energy harvesting algorithm which is based upon a frequency selective fading map. Through the algorithm, a receiver of mobile device can get fading information at each frequency and select a frequency which has the best quality. At the end, the simulation result demonstrates its superiority by showing a 4.45dB improvement in comparison to a deep fading frequency point.

Estimation of Optical Properties under High Temperature Conditions (고온 광학특성 평가 기법)

  • Jin, Doo-Han;Jeong, Kyung-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.592-598
    • /
    • 2017
  • A method for estimating the optical characteristics of ceramic materials under high temperature conditions has been applied and evaluated. For that purpose, an interface system combined with a photo-spectrometer was made to keep the samples at the required high temperature. The transmittance of the samples was measured at various temperatures. The measured transmittance data was used to estimate the refractive index using an optical simulation model in conjunction with the Sellmeier equation. The Sellmeier equation parameters were selected by trial-and-error when the transmittance recalculated using the estimated refractive index was compared with the measured transmittance. Furthermore, the estimated refractive indices were checked by a comparison with the reference data at some typical wavelengths at room temperature.

Performance Comparison of Multicast ABR Flow Control Algorithms with Fast Overload Indication in ATM Networks (ATM망에서 신속한 폭주통지 기능을 지닌 멀티캐스트 ABR 흐름제어 알고리즘의 성능비교)

  • Kim, Dong-Ho;Kim, Byung-Chul;Cho, You-Ze;Kwon, Yul
    • Journal of KIISE:Information Networking
    • /
    • v.27 no.1
    • /
    • pp.98-107
    • /
    • 2000
  • This paper compares the performance of feedback consolidation algorithms with or without a fast overload indication function which has been recently proposed in the ATM Forum for multicast ABR (Available Bit Rate) services in ATM networks. We use the performance criteria such as the ACR (Allowed Cell Rate) of a source, queue length at a switch, link utilization, fairness, and BRM (Backward Resource Management) cell overhead. Simulation results show that performance of the feedback consolidation algorithms with a fast overload indication function can be improved sign.ificantly than that of algorithms without this function in terms of ramp-down delay, particularly in initial start-up period or under a severe overload situation. The fast overload indication function can be combined with any feedback consolidation algorithm, whereas its performance is highly dependent on an underlying basic feedback consolidation algorithm.

  • PDF

Sensorless Speed Control of Induction Motor using Model Reference Adaptive Control and Direct Torque Control System (모델기준적응제어 및 직접토크제어 시스템을 이용한 유도전동기의 센서리스 속도제어)

  • Kim, Sung-Hwan;Jeong, Bum-Dong;Yoon, Doo-O;Lee, Sung-Gun;Oh, Sae-Gin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.12
    • /
    • pp.2708-2715
    • /
    • 2012
  • This paper proposes a new sensorless speed control scheme of induction motor using Model Reference Adaptive Control and Direct Torque Control System. The Model Reference Adaptive Control System is based on the comparison between the outputs of Reference Model and Adjustable Model. The error between the estimated quantities obtained by the two models is used to drive a suitable adaptation mechanism which generates the estimated rotor speed for the Adjustable Model. And the Direct Torque Control scheme controls torque and flux by restricting the flux and torque errors within respective hysteresis bands, and motor torque and flux are controlled by the stator voltage space vector using optimum inverter switching table. The simulation results of proposed method indicate good speed responses from the low speed range to the high, and also show favorable characteristics of load operation.