• Title/Summary/Keyword: Comparison of Measurement Method

Search Result 1,174, Processing Time 0.031 seconds

Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study (비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석)

  • Jung, Chang-Hoon;Park, Jin-Hee;Hwang, S.M.
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

A Study of Form Measurement using Noncontact Sensor (비접촉식 센서를 사용한 형상 측정 연구)

  • 송정섭;황윤호;배종일;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.407-410
    • /
    • 1995
  • Many researches on measurement technology has been made and developed by various methods. Considering the measurement environment with cutting fluid, coolant and the like, contact type measurement methods are mostly used. But contact measurement method has measuring force and so the sensing head becomes worn. By these reasons, we considered sensors not influenced by the former fluid and so can acquire accrate measured values using error compensation due to temperature and vibration. For this purpose, eddy current sensors and Extended kalman Filter Algorithm for processing measured data has been used. In this paper, we present new technology that can be used for measuring workpiece with previous bad environment using direct method and comparison measurement method. We used cylindrical workpieces which were produced by grinding machine for the target.

  • PDF

Analysis of Measurement Error for PM-10 Mass Concentration by Inter-Comparison Study (비교 측정을 통한 PM-10 질량농도의 오차 분석)

  • Jung, Chang-Hoon;Cho, Yang-Sung;Hwang, S.M.;Jung, Y.G.;Ryu, J.C.;Shin, D.S.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.689-698
    • /
    • 2007
  • Particular attention is paid to the validity of PM-10 measurement using beta attenuation method. In this study, the inter-comparison studies were undertaken for PM-10 sampler with different measuring methods. The three beta attenuation monitoring instruments (BAM1020, FH C-14, and DIGS-150) and filter based gravitational method using High Volume Air Sampler were collocated and mass concentrations were compared from August to November, 2006. The results of the investigation show that beta attenuation monitoring instruments are comparable with gravitational method within 10% of measurement error. For specific conditions under high humidity and high concentrations, the inter-comparison results also showed a relatively good agreement and this can be explained as the effect of inlet heating of beta attenuation instrument. Subsequently, this study shows that beta attenuation monitoring instruments can be equivalently used with reasonable validity when compared gravimetric method.

The comparison of the basic human body measurement definitions and anthropometric terms between KS and ISO (인체 측정 방법 및 측정 항목에대한 KS와 ISO의 비교)

  • 이영숙;김동진;남경희;안병덕;이관석
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.247-255
    • /
    • 1997
  • In this study, the comparison of the basic human body measurement definitions and anthropometric terms between the Korean Standard and the International Standard. Measurement definitions, measurement method and measurement terms of the international standard ISO 8559, 7250 were compard with the KSRI-88-103-IR. We have tried to suggest the new methods and new terms such as eye height, waist height, arm length.

  • PDF

A Logical Framework of Comparison Shopping Effectiveness and Comparison Challenge Methodology

  • Lee, Jae-Won
    • Proceedings of the CALSEC Conference
    • /
    • 2005.03a
    • /
    • pp.130-134
    • /
    • 2005
  • This research describes the comparison broker's role and its effectiveness measurement using a developed logical framework of comparison shopping service. And verifies that seller-led comparison challenge method provide comparison information of products to buyers more efficiently. In electronic commerce, buyer's satisfaction of purchase (S) can be defined as an interactive function between seller's competitiveness vector (P) of products that supplied to the market, and buyer's informed level vector (B) of products that is known from a lot of sources. Then the buyer's informed level can be changed through the information analysis among products by transformation process using comparison matrix (C). So the role of comparison shopping is to construct a comparison matrix and to serve it to the buyers, and to change the buyer's informed level. The changed informed level influences a buyer's satisfaction, that improved satisfaction of purchase is defined as the effectiveness of comparison shopping. As a perfect provision and usage of comparison matrix is impossible cause of cognitive limit, the most efficient method for improving the comparison effectiveness is the comparison challenge that detects the comparison elements of the largest buyer's information efficiency, and then to be compared between elementary products selectively. This research verifies the substantial superiority of comparison challenge through television market data experiments.

  • PDF

Study on the Sensivivity Difference Measurement by Ultrasonic Testing (초음파탐상(超音波探傷)에서의 감도차(感度差) 측정(測定) 연구(硏究))

  • Chung, Yong-Moo;Ann, Hee-Sung;Lee, Yun-Peel
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.2 no.1
    • /
    • pp.5-9
    • /
    • 1982
  • Experiments were performed according to ultrasonic attenuation measurement and comparison method of DAC curve to analyze the difference between PSI and 2nd ISI ultrasonic testing results. Smaller error was found by comparison method of DAC curve, and that method was more useful practically.

  • PDF

A System for Measuring 3D Human Bodies Using the Multiple 2D Images (다중 2D 영상을 이용한 3D 인체 계측 시스템)

  • 김창우;최창석;김효숙;강인애;전준현
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.5
    • /
    • pp.1-12
    • /
    • 2003
  • This paper proposes a system for measuring the 3D human bodies using the multiple 2D images. The system establishes the multiple image input circumstance from the digital camera for image measurement. The algorithm considering perspective projection leads us to estimate the 3D human bodies from the multiple 2D images such as frontal. side and rear views. The results of the image measurement is compared those of the direct measurement and the 3D scanner for the total 40 items (12 heights, 15 widths and 13 depths). Three persons measure the 40 items using the three measurement methods. In comparison of the results obtained among the measurement methods and the persons, the results between the image measurement and the 3D scanner are very similar. However, the errors for the direct measurement are relatively larger than those between the image measurement and the 3D scanner. For example, the maximum errors between the image measurement and the 3D scanner are 0.41cm in height, 0.39cm in width and 0.95cm in depth. The errors are acceptable in body measurement. Performance of the image measurement is superior to the direct. because the algorithm estimates the 3D positions using the perspective projection. In above comparison, the image measurement is expected as a new method for measuring the 3D body, since it has the various advantages of the direct measurement and 3D scanner in performance for measurement as well as in the devices, cost, Portability and man power.

Evaluation of Thermodynamic Method for Pump Performance Measurement (열역학적 방법을 이용한 펌프 운전성능 평가법 검토)

  • Kang, Shin-Hyoung;Kim, Jin-Kwon;Hong, Soon-Sam;Yates, Alex
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.3 s.8
    • /
    • pp.25-30
    • /
    • 2000
  • Thermodynamic method of pump performance measurement calculates pump efficiency and flowrate by measuring fluid temperature increase and pressure rise through the pump. The theory of this method is investigated and precise comparison experiment with classical hydraulic method was conducted to verify the accuracy. Classical hydraulic pump performance measurement results and Yatesmeter results based on the thermodynamic method showed good agreement in measured performance.

  • PDF

An international Comparison Measurement of Silicon Wafer Sheet Resistance using the Four-point Probe Method

  • Kang, Jeon-Hong;Ying, Gao;Cheng, Yuh-Chuan;Kim, Chang-Soo;Lee, Sang-Hwa;Yu, Kwang-Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.325-330
    • /
    • 2015
  • With approval from the Asia Pacific Metrology Program Working Group on Materials Metrology (APMP WGMM), an international comparison for sheet resistance standards for silicon wafers was firstly conducted among Korea Research Institute of Standards and Science (KRISS) in Korea, CMS/ITRI in Taiwan, and NIM in China, which are national metrology institutes (NMIs), from August 2011 to January 2012. The sheet resistance values of the standards are $10{\Omega}$, $100{\Omega}$, and $1000{\Omega}$; the measurement was conducted in sequence at KRISS, CMS/ITRI, NIM, and KRISS again using the four-point probe method with single and dual configuration techniques. The reference value for the measurement results of the three NMIs was obtained through averaging the values of the three results for each sheet resistance range. The differences between the reference value and the measured values is within 0.22% for $10{\Omega}$, 0.17% for $100{\Omega}$, and 0.12% for $1000{\Omega}$. Therefore, the international consistency for conducting sheet resistance measurements is confirmed within 0.22% through the APMP WGMM approved comparison.

Measurement of Axis Squireness by using Reversal Method (반전법을 이용한 축 직각도 측정방법)

  • Lee C.W.;Song J.Y.;Ha T.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.436-439
    • /
    • 2005
  • In general a square master and a dial gauge are used to measure the axis squareness on the spot. This method is a comparison measurement and its accuracy depends on the square accuracy wholly. Therefore the accuracy of a square master is very important and it is impossible that the accuracy of a square measurement is superior to the accuracy of a square master. In this paper, the new method of square measurement is proposed for measuring square without a square master and easily. This method is an absolute measurement by using a reversal method and can be used to measurement the accuracy of a square master.

  • PDF