• Title/Summary/Keyword: Comparison by Operating mode

Search Result 48, Processing Time 0.028 seconds

ZVS Operating Range Extension Method for High-Efficient High Frequency Linked ZVS-PWM DC-DC Power Converter

  • Sato S.;Moisseev S.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.227-230
    • /
    • 2003
  • In this paper, a full bridge edge-resonant zero voltage mode based soft-switching PWM DC-DC power converter with a high frequency center tapped transformer link stage is presented from a practical point of view. The power MOSFETS operating as synchronous rectifier devices are implemented in the rectifier center tapped stage to reduce conduction power losses and also to extend the transformer primary side power MOSFETS ZVS commutation area from the rated to zero-load without a requirement of a magnetizing current. The steady-state operation of this phase-shift PWM controlled power converter is described in comparison with a conventional ZVS phase-shift PWM DC-DC converter using the diodes rectifier. Moreover, the experimental results of the switching power losses analysis are evaluated and discussed in this paper. The practical effectiveness of the ZVS phase-shift PWM DC-DC power converter treated here is actually proved by using 2.5kW-32kHz breadboard circuit. An actual efficiency of this converter is estimated in experiment and is achieved as 97$\%$ at maximum.

  • PDF

Automatic P/PI speed controller design for industry servo drives (산업용 서보 구동 시스템을 위한 자동 P/PI 속도 제어기 설계)

  • Bae, Sang-Gyu;Seok, Jul-Ki;Kim, Kyung-Tae;Lee, Dong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.179-181
    • /
    • 2003
  • Conventional P/PI speed controller of today's servo drives should be manually tuned the controller switching set-point by trial-and-errors, which may translate the drive system down-time and loss of productivity. The adjustable drive performance is heavily dependent on the qualify of the expert knowledge and becomes inadequate in applications where the operating conditions change in a wide range, i.e., tracking command, cceleration/deceleration time, and load disturbances. In this paper, the demands on simple controls/setup are discussed for industry servo drives. Analyzing the frequency content of motor torque command, P/PI control mode switching is automatically peformed with some prior knowledge of the mechanical dynamics. The dynamic performance of the proposed scheme assures a desired tracking response curve with minimal oscillation and settling time over the whole operating conditions. For comprehensive comparison of traditional P/PI control scheme, extensive test is carried out on actual servo system.

  • PDF

Designs for 25-kA and 40-kA Vapor-Cooled Bi2223/Copper Leads with the Bi2223 Section Operating in the Current-Sharing Mode

  • Lee, Haigun;Kim, Ho-Min;Yukikazu Iwasa;Kim, Keeman
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.4
    • /
    • pp.222-230
    • /
    • 2003
  • This paper presents reference designs for vapor-cooled HTS/Copper leads rated at 25 kA and 40 kA and that satisfy a protection criterion. Each HTS section is cooled by the effluent helium vapor boiling from a 4.2-K bath. Each HTS section is based on a design concept in which a short portion of its warm end (77.3 K) operates in the current-sharing mode; such operation results in a considerable saving for HTS materials required in the HTS section. Two designs of "fully superconducting" vapor-cooled HTS sections, one rated at 25 kA and the other at 40 kA are also presented as comparison bases for the new HTS sections. Each warm end of HTS sections is coupled to an optimal vapor-cooled copper lead rated at the same current as that for the HTS section. The extra coolant required at 77.3 K at the coupling station, an optimal length of the copper section will be shorter than that optimized for helium-vapor cooling between 4.2 K and room temperature.mperature.

Evaluation of Primary Coolant pH Operation Methods for the Domestic PWRs (국내 PWR의 일차냉각재 pH 운전방법의 평가)

  • Paek, Seung-Woo;Na, Jung-Won;Kim, Yong-Eak;Bae, Jae-Heum
    • Nuclear Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.52-62
    • /
    • 1992
  • Radioactive nuclides deposited on out-of-core surface after the radiation in the core by the transport of corrosion products (CRUD) through the primary coolant system in PWR which is the major plant type in Korea, are leading sources of radiation exposure to plant maintenance personnel. Thus, the optimal chemistry operation method is required for the reduction of radiation exposure by the corrosion products. This study analysed the actual water chemistry operation data of four operating domestic PWRs. And in order to evaluate the coolant chemistry operation data, a computer code which can calculate the activity buildup in the various chemistry conditions of PWR coolant was employed. Through the analysis of comparison between the activity buildup of actual water chemistry operation mode and that of assumed Elevated Li operation mode calculated by the computer code, it was found that the out-of core radioactivity can be reduced by diminishing the deposition of corrosion products on the core in case that the Elevated Li operation mode is applied to the coolant chemistry operation of PWR. And the higher coolant pH operation was shown to have the advantage of the reduction of out-of-core activity buildup if the integrity of system structural materials and fuel cladding is guaranteed.

  • PDF

GMA Torch Configuration for Efficient Use of Argon Gas Part 2 : Comparison between AMAG DMAG Process (아르곤 가스를 효율적으로 사용하기 위한 GMA 용접 토치 구조 Part 2 : AMAG와 DMAG 공정의 비교)

  • 문명철;고성훈;유중돈
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.46-52
    • /
    • 1999
  • The auxiliary gas-shielded MAG (AMAG) process, which was devised to provide an argon-rich shielding environment using small amount of argon gas, was investigated experimentally to figure out its effects on metal transfer and weld quality. Proper conditions for the AMAG process including the argon gas ratio, position and direction of the auxiliary nozzle were determined experimentally. Performance of the AMAG process was compared with that of the double gas-shielded MAG(DMAG) and MAG processes by monitoring the bead profile, current and voltage waveforms. The AMAG process was found to provide better bead profile, more stable arc and wider operating range of spray transfer mode compared with the DMAG process. In general, performance of the AMAG process using the argon ratio of 30% was comparable to that of the MAG process using 80% argon and 20% CO₂ gas.

  • PDF

A characteristic test of Auxiliary power supply for High Speed Rolling stock 350 experimental (HSR-350x) (한국형고속열차 보조전원장치 특성시험)

  • Jeong, Sang-Hun;Kim, Dong-Hwan;Lee, Byung-Song;Lee, Tae-Hyung
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.185-191
    • /
    • 2006
  • Auxiliary power supply developed by domestic technology has very important function that not only effect on main power converter & inverter system, traction motor and train control system which are related to performance of train, but also influence on power supply for HVAC(Heat, Ventilation, Air-conditioning) and lighting device which are related to comfort of passengers. This paper shows characteristic test results of auxiliary power supply such as working condition and performance, which is associated with velocity of train, operating mode and surrounding equipment, through test running. Also it shows the results deduced from comparison analysis between designed data and manufactory test data as measuring in put voltage of auxiliary power supply. And, it propose a modification of design parameter for stabilizing operation and improving reliability.

  • PDF

A Study on the Electronic-ECR Valve for Light Duty Diesel Engine (소형 디젤 엔진용 배기 재순환용 전자식 밸브에 관한 연구)

  • 송창훈;이민호;정용일;차경옥
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.4
    • /
    • pp.37-43
    • /
    • 2003
  • The exhaust gas recirculation (EGR) is needed for one of various strategies to reduce NOx emission. But to get the proper EGR rate, the intake and exhaust system become complicated, also application of EGR system is difficult because of the penalty in fuel consumption and the increase in particulate matter. This study is focused on the development of EGR valve using the electrical method. The effects of EGR on the characteristics of NOx, CO, CO2 emissions and particulate mater have been investigated using small-displacement size 0.8-liters engine of diesel passenger car operating at several loads and speeds. After the analysis and comparison between conventional E-EGR valve and developed E-EGR valve performance by test bench, the estimation of vehicle application was executed through the EGR map and CVS-75 test result measured on the chassis dynamometer.

Evaluation and Comparison of Land Consumption Efficiencies of Transportation Modes (교통수단의 토지소모 효율성 비교분석)

  • Shin, Yong Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6D
    • /
    • pp.801-807
    • /
    • 2008
  • This study attempts to evaluate and compare the land consumption efficiencies of various urban transport modes, utilizing the time-area method. With the careful considerations of travel conditions and modal characteristics, equations for the computation of time-area for various different modes are derived. With the appropriate assumed values of parameters, time-area consumptions per person per km for each mode both for peak and off-peak situations are computed and evaluated. The relationships between the time-area consumed and operating speed for each mode are graphically demonstrated and discussed. An example of the time-area consumed for a hypothetical commuter round-trip using various modes are also presented in order to clearly show the consumption of parking requirements by specific modes. It shows that regardless of facilities used, auto users are by far the worst in terms of area efficiency and that transit, especially rail rapid transit, is a superior mode. Pedestrian and bicycle, though consuming more than expected, also demonstrate the advantage in case of a short-distance trip in terms of area efficiency compared with the bus transit modes.

Parallel Computing Environment based on Windows Operating System (Windows 운영체제 기반의 병렬 계산 환경)

  • Choe, Jeong Yeol;Sin, Jae Ryeol;Kim, Myeong Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.16-25
    • /
    • 2003
  • A parallel computing environment based on Windows operating system was constructed and a performance test was mode in comparison with Linux based systems. The Windows 2000 cluster was composed with servers and clients connected by Fast-ethernet, within which two sub-clusters may operates together or separately. Compaq Visual Fortran complier and two MPI libraries, MPICH.NT.1.2.2 and NT-MPICHNT.1.2 were installed as computing tools. Parallel computing performance tests were carried out using two-dimensional preconditioned Navier-Stokes code to examine the dependency on the number of processors, problem size and MPI libraries, those were compared with results from Linux clusters. Results shows that a cluster based on the user-friendly Windows operating system is also useful for the parallel computing and has good performance comparable to the previous Linux clusters.

Nitrogen-Oxygen Separation Characteristics by Polyimide Membrane System for Controlled Atmosphere Storage (CA저장을 위한 폴리이미드 막 시스템의 질소-산소 분리특성)

  • 이호원;현명택;고정삼
    • Food Science and Preservation
    • /
    • v.5 no.3
    • /
    • pp.239-246
    • /
    • 1998
  • Polyimide membrane system was designed for manufacturing nitrogen-enriched gas, and basic technical data was suggested for appling this system to controlled atmosphere storage. The permeability characteristics of pure oxygen and nitrogen could be explained by dual-mode sorption model. There was substantial decrease in the permeation rates of oxygen, which is the more permeable gas, through the polyimide membrane due to the presence of nitrogen in comparison with pure oxygen. However, the permeation rates of nitrogen was increased by the presence of oxygen. The ideal separation factor was in the range of 5 to 6 in the range of temperature and pressure difference studied, and the separation factor of air was lower than the ideal separation factor. The increase of ideal separation factor with increasing temperature is due to the fact that the activation energy for oxygen is larger than that for nitrogen. Nitrogen concentration decreased rapidly with increasing product recovery, and it was found that this is a major operating factor to obtain nitrogen concentration required for controlled atmosphere storage. A relation equation, by which nitrogen concentration in storehouse can be predicted, was suggested under the establishment of a hypothetical model for controlled atmosphere storage process using polyimide membrane system.

  • PDF