• Title/Summary/Keyword: Comparing

Search Result 26,474, Processing Time 0.056 seconds

Investigation of ground condition charges due to cryogenic conditions in an underground LNG storage plant (지하 LNG 저장 시험장에서 극저온 환경에 의한 지반상태 변화의 규명)

  • Yi Myeong-Jong;Kim Jung-Ho;Park Sam-Gyu;Son Jeong-Sul
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.67-72
    • /
    • 2005
  • To investigate the feasibility of a new concept of storing Liquefied Natural Gas (LNG) in a lined hard rock cavern, and to develop essential technologies for constructing underground LNG storage facilities, a small pilot plant storing liquid nitrogen (LN2) has been constructed at the Korea Institute of Geoscience and Mineral Resources (KIGAM). The LN2 stored in the cavern will subject the host rock around the cavern to very low temperatures, which is expected to cause the development of an ice ring and the change of ground condition around the storage cavern. To investigate and monitor changes in ground conditions at this pilot plant site, geophysical, hydrogeological, and rock mechanical investigations were carried out. In particular, geophysical methods including borehole radar and three-dimensional (3D) resistivity surveys were used to identify and monitor the development of an ice ring, and other possible changes in ground conditions resulting from the very low temperature of LN2 in the storage tank. We acquired 3D resistivity data before and after storing the LN2, and the results were compared. From the 3D images obtained during the three phases of the resistivity monitoring survey, we delineated zones of distinct resistivity changes that are closely related to the storage of LN2. In these results, we observed a decrease in resistivity at the eastern part of the storage cavern. Comparing the hydrogeological data and Joint patterns around the storage cavern, we interpret this change in resistivity to result from changes in the groundwater flow pattern. Freezing of the host rock by the very low temperature of LN2 causes a drastic change in the hydrogeological conditions and groundwater flow patterns in this pilot plant.

A Comparison Study of Alkalinity and Total Carbon Measurements in $CO_2$-rich Water (탄산수의 알칼리도 및 총 탄소 측정방법 비교 연구)

  • Jo, Min-Ki;Chae, Gi-Tak;Koh, Dong-Chan;Yu, Yong-Jae;Choi, Byoung-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.1-13
    • /
    • 2009
  • Alkalinity and total carbon contents were measured by acid neutralizing titration (ANT), back titration (BT), gravitational weighing (GW), non-dispersive infrared-total carbon (NDIR-TC) methods for assessing precision and accuracy of alkalinity and total carbon concentration in $CO_2$-rich water. Artificial $CO_2$-rich water(ACW: pH 6.3, alkalinity 68.8 meq/L, $HCO_3^-$ 2,235 mg/L) was used for comparing the measurements. When alkalinity measured in 0 hr, percent errors of all measurement were 0~12% and coefficient of variation were less than 4%. As the result of post-hoc analysis after repeated measure analysis of variance (RM-AMOVA), the differences between the pair of methods were not significant (within confidence level of 95%), which indicates that the alkalinity measured by any method could be accurate and precise when it measured just in time of sampling. In addition, alkalinity measured by ANT and NDIR-TC were not change after 24 and 48 hours open to atmosphere, which can be explained by conservative nature of alkalinity although $CO_2$ degas from ACW. On the other hand, alkalinity measured by BT and GW increased after 24 and 48 hours open to atmosphere, which was caused by relatively high concentration of measured total carbon and increasing pH. The comparison between geochemical modeling of $CO_2$ degassing and observed data showed that pH of observed ACW was higher than calculated pH. This can be happen when degassed $CO_2$ does not come out from the solution and/or exist in solution as $CO_{2(g)}$ bubble. In that case, $CO_{2(g)}$ bubble doesn't affect the pH and alkalinity. Thus alkalinity measured by ANT and NDIR-TC could not detect the $CO_2$ bubble although measured alkalinity was similar to the calculated alkalinity. Moreover, total carbon measured by ANT and NDIR-TC could be underestimated. Consequently, it is necessary to compare the alkalinity and total carbon data from various kind of methods and interpret very carefully. This study provide technical information of measurement of dissolve $CO_2$ from $CO_2$-rich water which could be natural analogue of geologic sequestration of $CO_2$.

Studies on the External Structure of the Cuticle of Silkworm pupa (Bombyx mori L.) (가잠용외피의 외부구조에 관한 조사연구)

  • 윤종관
    • Journal of Sericultural and Entomological Science
    • /
    • v.20 no.2
    • /
    • pp.10-14
    • /
    • 1978
  • There are relatively many reports have been issued on he active movement of cuticle of larva. which tend to protect their body, however, only a few reports have been disclosed on the cuticle of pupal body except the small portion of rectangle which shown tortoise-shell shape. In this connection, many portion of the external structure of pupal cuticle has been studied and the following. results were found: 1) No. spot of rectangle which is sculptured in the surface of cuticle that born by branching. out of the development of cell in imaginal bud of antenna and head were found. However, in the compound eye of net shaped sculpture was found in the (equation omitted) shaped parts which holding. the diameter of about 8u and the surrounding area has the small bump and the one is dark brown coloured comparing with shape. 2) The sculpture shape of thorax is a little different than in the head. However, (equation omitted) portion is varies from the segment to segment. In general, it is not very clear than the compound eye in the head, the dark brown bump shape is slowly fade a from the prothorax, mesothorax to metathorax. 3) The surface of intersegment membrane is colourless or slightly yellow, and the entire surface has stripped marking with thine lines. 4) In the abdominal segment, there are many and small sculptures in net shape around the (equation omitted) shape portions. 5) The size of sculpture in (equation omitted) portion of abdomen is smaller than one in thorax, and in the same segment, the dorsal is smaller than abdomen and the rear portion of the segment is larger than the front of segment. 6) After the 7th abdominal segment, no intersegmental membrane is found and the cuticle of the external structure is the same as external structure of the segment. 7) The seta is not found in head, compound eye, antenna and wing which portions were subdivided by development of imagined bud of the cell, no seta is found in cuticle of the segment in the general cell of the larva stage and also in the dorsal and intersegmental membrane.

  • PDF

Difference of Somatic Symptoms between Anxiety Disorder and Major Depressive Disorder and Their Domainal Association with Suicidal Idealization, Plan and Attempts (불안 장애와 주요우울장애에서 나타나는 신체 증상과 증상군에 따른 자살 사고, 계획, 행동과의 관계 고찰)

  • Ahn, Jun Seok;Kim, Eun young;Cho, Maeng Je;Hong, Jin Pyo;Hahm, Bong-Jin;Chung, In-Won;Ahn, Joon-Ho;Jeon, Hong Jin;Seong, Su Jeong;Lee, Dong-Woo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.24 no.2
    • /
    • pp.174-183
    • /
    • 2016
  • Objectives : The aim of this study is to evaluate difference of somatic symptoms of anxiety disorder and major depressive disorder and domainal association with suicidal idealization, plan, and attempts. Methods : A total of 359 adults diagnosed with major depressive disorder and anxiety disorder of last one year participated. Participants interviewed with certain sections of Korean version of Composite International Diagnostic interview of CIDI. Sections of interests includes questionnaires regarding somatic symptoms and suicidal idea, plan and attempts of last one year. Results : Chest pain shows more prevalence in major depressive disorder. Symptoms of Headache and loose stool are more prevalent in anxiety disorder. Difficulty in equilibrium and fainting spells are more common somatic complaints of co-diagnosis states of anxiety disorder and major depressive disorder. Comparing 3 domains of pain symptoms, gastrointestinal symptoms and pseudo-neurological symptoms, pain symptom domains, gastrointestinal symptoms domain shows significant statistic difference between diagnosis. Average somatic symptom numbers of each symptom domains increase through suicidal idealization, plan and attempt, accordingly. Conclusions : Our finding shows some of somatic symptoms are more prevalent at certain diagnosis. Since increasing numbers of somatic complaints of each symptom domains goes with the suicidal idealization to suicidal attempts, proper psychiatric evaluation and consultations are crucial for patients with numerous somatic complaints in non-psychiatric clinical settings.

Basic Study for Selection of Factors Constituents of User Satisfaction for Micro Electric Vehicles (초소형전기차 사용자만족도 구성요인 선정을 위한 기반연구)

  • Jin, Eunju;Seo, Imki;Kim, Jongmin;Park, Jejin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.581-589
    • /
    • 2021
  • With the recent increase in the introduction of micro-electric vehicles in Korea, interest in micro-electric vehicle user satisfaction is increasing to revitalize related markets. In this paper, a basic study was conducted on the development of public services using micro-electric vehicle based on the constituent factors of user satisfaction. The survey includes: ① 'Analytic Hierarchy Process (AHP) for selecting the priority factors of user satisfaction of micro-electric vehicles', ② 'A survey of micro-electric vehicles image' to collect data in advance for providing users' preferences and transportation services for micro-electric vehicles, ③ In order to investigate the user satisfaction level of users who actually operated micro-electric vehicles, the order of 'user satisfaction survey of micro-electric vehicle drivers' was conducted. In the Analytic Hierarchy Process (AHP) analysis, it was found that users regarded as important in the order of 'user utilization data', 'vehicle movement data', and 'charging service data'. In the micro-electric vehicle image survey, users perceived micro-electric vehicles more positively in terms of "safety", 'durability', 'Ride comfort', 'design', 'MOOE (Maintenance and other operating expense)', and 'environment-friendly' when comparing micro-electric vehicles with electric motorcycles. In the survey on the user satisfaction of micro-electric vehicle drivers, the use of micro-electric vehicle did not directly affect work performance efficiency, and there was an experience of being disadvantaged on the road due to the size of the micro-electric vehicle, and driving in a cluster of micro-electric vehicle for outdoor advertisements. The city's public relations effect was great, but it was concerned about safety. In the future, based on the results of this study, we plan to build a user satisfaction structural equation model, preemptively discover feedback R&D for micro-electric vehicle utilization services in the public field, and actively seek to discover new public mobility support services.

Evaluation of Image Quality for 2D TSE(RT) and 3D GRASE in MRCP Study: Fast MRCP Method (췌담관자기공명영상에서 2D TSE(RT)와 3D GRASE(BH) 기법에 대한 영상의 질 평가 : Fast MRCP 기법)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.983-989
    • /
    • 2021
  • In this study, we intend to evaluate image quality and provide to clinical basic data by applying to 2D TSE (RT) and 3D GRASE (BH) techniques using Fast MRCP testing methods for application to patients in poor patient condition. Data were analyzed for 30 patients (15 males, 15 females, and 64±4.26 average age) who underwent MRCP tests. The equipment used was Ingenia CX 3.0 T equipment and Ds anterior coil was used for data acquisition. SNR and CNR of each image were measured through quantitative analysis, and the quality of the image was evaluated by dividing it into 5 grades for qualitative evaluation. The image evaluation was performed on the paired t-test and the Wilcoxon test, and when the p value was 0.05 or less, it was considered to be significant. As a result of quantitative analysis of SNR and CNR, 3D GRASE (BH) was measured high when comparing the two techniques, 2D TSE (RT) MRCP and 3D GRASE (BH) (p<0.05). The qualitative analysis result is a sharpness of the bile duct: 3D GRASE(BH): 4.12±0.03, Overall image quality: 3D GRASE(BH): 4.21±0.91 was high (p=0.001). The motion artifact of the bile duct showed no significant difference with two techniques(2D TSE(RT): 4.41±0.04, 3D GRASE(BH): 4.53±0.14(p=0.067). However, the background suppression obtained significant results with 2D TSE(RT) of 4.14±0.55(p=0.001). In conclusion, as a result of using the Fast MRCP testing method, MRCP images obtained by 3D GRASE (BH) had an advantage over MRCP images using 2D TSE (RT). However, there will be useful results of 2D TSE(RT) MRCP technique in patients who have difficulty holding their breath.

A Study on the Oxy-Combustion of the Coal in Drop Tube Furnace (Drop Tube Furnace에서 석탄의 순산소 연소 특성)

  • Roh, Seon Ah;Yun, Jin Han;Lee, Jung Kyu;Keel, Sang In;Min, Tai Jin;Kim, Sang-Bok;Park, In-Yong;Han, Bangwoo;Kim, Jin-Tae
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.367-371
    • /
    • 2021
  • The oxy-combustion system is one of the carbon recovery and storage technologies (CCS: Carbon capture & storage) that performs coal combustion using pure oxygen and recirculated flue gas. This is a technology that facilitates storage of carbon dioxide by generating an exhaust gas consisting of only carbon dioxide without a process of separating carbon dioxide and nitrogen when coal is burned using pure oxygen and recirculated flue gas mixture instead of a conventional air combustion system that produces carbon dioxide and nitrogen mixed exhaust gas. In this study, the characteristics of generated NO and SO2 as atmospheric pollutants during oxy-combustion were examined using O2/CO2 mixed simulation gas. The reaction temperature was varied from 900 ℃ to 1200 ℃ and oxygen partial pressure was varied from 30% to 50%. The results showed that NO and SO2 concentrations in flue gas increased as the oxygen concentration and the reaction temperature in the furnace increased. The partial pressure of CO2 in flue gas also increased as the oxygen concentration and the reaction temperature in the furnace increased. As a results of comparing NO production of 30% O2/CO2 oxy-combustion with air combustion, NO in flue gas increased with reaction temperature in both experiments and NO of oxy-combustion was 40 ~ 80 ppm lower than that of air combustion.

Long-term forecasting reference evapotranspiration using statistically predicted temperature information (통계적 기온예측정보를 활용한 기준증발산량 장기예측)

  • Kim, Chul-Gyum;Lee, Jeongwoo;Lee, Jeong Eun;Kim, Hyeonjun
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.12
    • /
    • pp.1243-1254
    • /
    • 2021
  • For water resources operation or agricultural water management, it is important to accurately predict evapotranspiration for a long-term future over a seasonal or monthly basis. In this study, reference evapotranspiration forecast (up to 12 months in advance) was performed using statistically predicted monthly temperatures and temperature-based Hamon method for the Han River basin. First, the daily maximum and minimum temperature data for 15 meterological stations in the basin were derived by spatial-temporal downscaling the monthly temperature forecasts. The results of goodness-of-fit test for the downscaled temperature data at each site showed that the percent bias (PBIAS) ranged from 1.3 to 6.9%, the ratio of the root mean square error to the standard deviation of the observations (RSR) ranged from 0.22 to 0.27, the Nash-Sutcliffe efficiency (NSE) ranged from 0.93 to 0.95, and the Pearson correlation coefficient (r) ranged from 0.97 to 0.98 for the monthly average daily maximum temperature. And for the monthly average daily minimum temperature, PBIAS was 7.8 to 44.7%, RSR was 0.21 to 0.25, NSE was 0.94 to 0.96, and r was 0.98 to 0.99. The difference by site was not large, and the downscaled results were similar to the observations. In the results of comparing the forecasted reference evapotranspiration calculated using the downscaled data with the observed values for the entire region, PBIAS was 2.2 to 5.4%, RSR was 0.21 to 0.28, NSE was 0.92 to 0.96, and r was 0.96 to 0.98, indicating a very high fit. Due to the characteristics of the statistical models and uncertainty in the downscaling process, the predicted reference evapotranspiration may slightly deviate from the observed value in some periods when temperatures completely different from the past are observed. However, considering that it is a forecast result for the future period, it will be sufficiently useful as information for the evaluation or operation of water resources in the future.

Evaluation of Carbon Sequestration Capacity of a 57-year-old Korean Pine Plantation in Mt. Taeh wa based on Carbon Flux Measurement Using Eddy-covariance and Automated Soil Chamber System (에디 공분산 및 자동화 토양챔버 시스템을 이용한 탄소 플럭스 관측 기반 태화산 57년생 잣나무조림지의 탄소흡수능력 평가)

  • Lee, Hojin;Ju, Hyungjun;Jeon, Jihyeon;Lee, Minsu;Suh, Sang-Uk;Kim, Hyun Seok
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.4
    • /
    • pp.554-568
    • /
    • 2021
  • Forests are the largest carbon (C) sinks in terrestrial ecosystems. Recently, as enhancing forest C sequestration capacity has been proposed as a basic direction of the Republic of Korea's "2050 Carbon Neutral Strategy," accurate estimation of forest C sequestration has been emphasized. According to the Intergovernmental Panel on Climate Change guidelines, sequestration quantity is calculated from changes in C stocks in forest C pools, such as biomass, deadwood, litter and soil layer, and harvested wood products. However, in Korea, only the overstory biomass increase is now considered the amount of sequestration quantity, so there can be a significant difference from the actual forest C sequestration. In this study, we quantified forest C exchange through C flux measurement using an eddy covariance system and an automated soil chamber system in a 57-year-old Korean pine plantation located in Mt. Taehwa, Gwangju-si, Gyeonggi-do. Then, the net amount of C sequestration was compared with the amount of the overstory biomass increase. We estimated the annual C stock change in the remaining C pools by comparing the net sequestration amount from the C flux measurement with the overstory biomass increase and C stock change in the litter layer. Therefore, the net C sequestration of the Korean pine plantation estimated from the flux measurement was 5.96 MgC ha-1, which was about 2.2 times greater than 2.77 MgC ha-1 of the overstory biomass increase. The annual C stock increase in the litter layer was estimated to be 0.75 MgC ha-1, resulting in a total annual C stock increase of 2.45 MgC ha-1 in the remaining C pools. Our results indicate that the domestic forest is a larger C sink than the current methods, implying that more accurate calculations of the C sequestration capacity are necessary to quantify C stock changes in C pools along with the C flux measurement.

Trend in Paternal Childcare Time for Preschool Children in Korea from 2004 to 2019 (아버지의 미취학자녀 돌봄시간 변화 추이 분석(2004-2019))

  • Lee, Jung-eun;Seo, Jiwon
    • Journal of Family Resource Management and Policy Review
    • /
    • v.25 no.3
    • /
    • pp.103-120
    • /
    • 2021
  • Recently, the importance of the fathers role in the care of young children has been emphasized in Korea for the balance of childcare responsibilities between mothers and fathers. This study investigates the trends in paternal childcare in Korea over the last 15 years. Childcare is divided into primary and developmental care and fathers's Childcare time and participation rates are inverstigated for dual- and single-income households. Data are collected from the four waves of the five-yearly Statistics of Korea Life Time Surveys between 2004(t1) and 2019(t4) including the workday time diaries of fathers with preschool children(n1=2,264, n2=1,242, n3=959, n4=952). Three major results are identified. First, paternal childcare time and participation rates have increased with dual-income fathers spending 24 more minutes a day with their young child(ren) in 2019 than in 2004, which is nearly double. Second, in the analysis of fathers' childcare time use and participation rates comparing primary and developmental care, primary care is found to have increased more than developmental care, especially among dual income fathers: this further exhibits a reversed relation between primary and developmental care over time. Third, the determinants of paternal childcare time are fathers' age, market labor time, commuting time, gender equality consciousness, and education. In particular, market labor time was significant in all four waves, while gender equality consciousness is only significant for single-income fathers. Based on these results, a specific agenda is provided for family-friendly policies to improve the balance of childcare roles between fathers and mothers, especially encouraging increased(significant and sufficient) participation of fathers in primary care activities.