• 제목/요약/키워드: Compaction condition

Search Result 186, Processing Time 0.029 seconds

A Study on the Uplift Capacity of Cylindrical Concrete Foundations for Pipe-Framed Greenhouse (파이프 골조온실의 원주형 콘크리트 기초의 인발저항력에 관한 연구)

  • ;;;;Shino Kazuo
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.4
    • /
    • pp.109-119
    • /
    • 1998
  • Recently pipe-framed greenhouses are widely constructed on domestic farm area. These greenhouses are extremely light-weighted structures and so are easily damaged under strong wind due to the lack of uplift resistance of foundation piles. This experiment was carried out by laboratory soil tank to investigate the displacement be haviors of cylindrical pile foundations according to the uplift loads. Tested soils were sampled from two different greenhouse areas. The treatment for each soil type are consisted of 3 different soil moisture conditions, 2 different soil depths, and 3 different soil compaction ratios. Each test was designed to be repeated 2 times and additional tests were carried out when needed. The results are summarized as follows : 1. When the soil moisture content are low and/or pile foundations are buried relatively shallow, ultimate uplift capacity of foundation soil was generated just after begining of uplift displacement. But under the high moisture conditions and/or deeply buried depth, ultimate up-lift capacity of foundation soil was generated before the begining of uplift displacement. 2. For the case of soil S$_1$, the ultimate uplift capacity of piles depending on moisture contents was found to be highest in optimum moisture condition and in the order of air dryed and saturated moisture contents. But for the case of soil S$_2$, the ultimate uplift capacity was found to be highest in optimum moisture condition and in the order of saturated and air dryed moisture contents. 3. Ultimate uplift capacities are varied depending on the pile foundation soil moisture conditions. Under the conditions of optimum soil moisture contents with 60cm soil depth, the ultimate uplift capacity of pile foundation in compaction ratio of 80%, 85%, and 90% for soil 51 are 76kg, 115kg, and 155kg, respectively, and for soil S$_2$are 36kg, 60kg, and 92kg, respectively. But considering that typical greenhouse uplift failure be occurred under saturnted soil moisture content which prevails during high wind storm accompanying heavy rain, pile foundation is required to be designed under the soil condition of saturated moisture content. 4. Approximated safe wind velosities estimated for soil sample S$_1$and S$_2$are 32.92m/s and 26.58m/s respectively under the optimum soil condition of 90% compaction ratio and optimum moisture content. But considering the uplift failure pattern under saturated moisture contents which are typical situations of high wind accompanying heavy rain, the safe wind velosities for soil sample S$_1$and S$_2$are not any higher than 20.33m/s and 22.69m/s respectively.

  • PDF

Experimental Analysis for Characteristics of Bank-Scour around Barrier (수리실험을 통한 보 연결부 제방 세굴 특성 분석)

  • Jeong, Seok Il;Lee, Seung Oh
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.34-39
    • /
    • 2017
  • Typical flow regime of overflow at barrier or weir constructed in mid and small streams becomes as the submerged flow during most flood events. One of major causes of barrier failure has been reported as the levee-scour near the conjuction node between barrier and levee. However, most related design guidelines in Korea have not mentioned about the protection of levee around barrier or weir in detail. Furthermore, most previous researches have focused on the flow characteristics of overflow around several types of weirs but they did not have considered the material properties of levee itself. In this study, local scour near barrier was investigated with different material properties of levee under the submerged overflow condition which is assumed to reenact a flood event. Based on results from Fritz et al. and Mavis et al., a theoretical formula was also proposed in initial stage of laboratory experiments. And hydraulic experiments were carried out for the verification of the proposed formula. Levee was installed in the prismetic trapezoidal open channel and most parts were made of concrete except for movable section in which scour was expected to occur for the efficiency of experimental procedure. Each compaction of movable section in levee was followed by the basis of the KS F 2312. Further, after performing the experiments to find the optimum water content for each sediment, the specific amount of water was injected before flowing water. The difference between the proposed theoretical formula and experiment results was not much but considerable, which might be caused by the effect of compaction. For theoretical approach, it seemed that the formula did not take into account the compaction of levee, thus the correction coefficient for levee compaction determined in the literature was considered. Finally, the formula for the length of scour around barrier or weir was proposed, which can be useful to predict a levee in the reference design of revetment in mid and small streams. As shortly future study, scour length of levee around barrier or weir under different flow conditions such as perfect overflow condition will be studied and it will be able to contribute to suggest the design formula or criteria under all overflow conditions near barrier or weir.

A Study on the Effectiveness of Injection in Environmentally-Friendly Bio-grouting with Soil Conditions (지반조건에 따른 친환경 바이오그라우팅 주입 효과에 관한 연구)

  • Kim, Daehyeon;Park, Kyung-Ho;Kim, Min-Seok;Kim, Sun-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4276-4283
    • /
    • 2015
  • The purpose of this research is to identify the effectiveness of injection with soil conditions by injecting CaCO3(created by microorganism reaction), which was recreated with equipment in similar situ condition. To analyze our research, we made 2 cases of single-layer (SP, SW) in D 150mm ${\times}$ H 300mm. Layers were made by RC 70, 80, 85, 90, 95% of soil condition. We measured uniaxial compression strength with cone penetrometer and watched injection range by checking a bulb formation around the injection nozzle. As a result, the relative compaction(RC) in more 85% were not injected in SW, we could identify the effect of bio-grouting technology on ground in relative compaction(RC) of injection ratio and cementation range.

The effect of sintering condition and composition on the mechanical properties of bond materials for micro-blades (Micro Blade용 Bond재료의 소결조건과 조성이 기계적 특성에 미치는 영향)

  • Kim, Song-Hee;Moon, Jong-Chul
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.137-144
    • /
    • 2007
  • Sintering condition and various chemical composition of bond materials for micro-blades were studied. The methods mixing of pure powders and using pre-alloyed powders for compaction and sintering were compared and optimized in terms of the evaluation of bending strength and fractographic study. The effect of the amount of graphite as a lubricant and diamond abrasive on the strength of sintered bond materials and fracture toughness was investigated. The strength decreased with increasing the amount of graphite and diamond abrasive.

  • PDF

A Study for Application of the Light Falling Weight lest on Subbase and Subgrade (노상 및 보조기층의 소형충격재하시험 활용방안 연구)

  • Choi, Jun-Seong;Kim, Jong-Min;Han, Jin-Seok;Kim, Bu-Il
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.85-98
    • /
    • 2009
  • The in-situ Compaction test using sand cone (RC) and Plate Bearing Capacity Test (PBT) has been widely used for evaluating the subgrade and subbase condition on the pavement system. However, because the in-situ RC and PBT test are expensive and take plenties of time for operation, these are very difficult to figure out the in-situ characteristics of subgrade and subbase strength in detail. Therefore, for faster and economical operation, this study is to compare the Light Falling Weight Tests and propose the LFWD test as the in-situ Compaction test. This study suggests the relationship between in-situ RC value, $K_{30}$, $M_R$ and $E_{LFWD}$ of the subgrade and subbase materials in Korea using the laboratory and in-situ testing.

  • PDF

A study on the settlement of earth dam by the changes of the density (흙댐의 밀도변화에 의한 압밀침하에 대한 연구)

  • 윤충섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.28 no.3
    • /
    • pp.89-98
    • /
    • 1986
  • This study was carried out for the settlement and camber of earth dam by the changes of the density. The testing material was taken five kinds of Soil used as banking material and it was compacted by 100, 95, 90, 85 and 80% compaction degree. The results of the settlement of earth dam whose height ranges from 10m to 50m are as follows. 1.The more the fine particle (n) increases, the higher the liquid limit (WL) and the lower the dry density (rd) becomes as follows; rd=2. 22-0. 0052n (gr/cm$_3$) rd=2. 394-0. 0164WL rd=2. 185-(5. 8n-2. 5WL)X10-$_3$ 2. The higher the optimum moisture content (Wo) becomes, the lower the density becomes as follows; rt,=2. 68-0. 028Wo rd=2. 578-0. 04Wo 3. 3.Most of the consolidation occurs immediately by loading and the more the fine particle increases, the lower the coefficient of consolidation becomes. 4.The more the fine particle increases and lower the compaction degree (D) becomes,the lower the pre-consolidation load (Pc) becomes but on the contrary the compression index (Cc) becomes higher. Those equation is as follows. Pc=3. 32-(4. 3n-3. 0D) X10-2 (kg/cm$^2$) Cc=0. 41+(1. 33n-4. 44D) X10-$^3$ 5.The more the consolidation load (P) increases, the lower the coefficient of volume change (mv) becomes with mv=ap-b, the higher the consolidation ratio (u) becomes with U= (0. 6~1. 35)PO.4 6.The more the fine particle (n) increases, the more the settlement of dam occurs with U=anb and 60-80% of the settlement occurs under construction. 7.The camber of dam has higher value in condition that has more fine particle, poorer compaction and higher height of dam. In the dam construction about twice value of table 7 is required for dam safety.

  • PDF

A Study on Crack Control of Tunnel Lining Concrete with Large Section (대단면 터널 라이닝 콘크리트의 균열저감 연구)

  • Kim, Wan-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.509-512
    • /
    • 2008
  • The lining concrete of water tunnel is a much capability to occur crack due to drying shrinkage and vibrator compaction etc. Because of crack of concrete induce structural problem and decrease durability of concrete, it is need to reduce crack of concrete. In this an Analytical study to analyze the effect of curing of concrete and compaction on the lining concrete. As the results, it was found that control of construction condition into curing of concrete and compaction improve on construction efficiency of the lining concrete.

  • PDF

A Study on the Deformation Characteristics on Underground Pipe to Backfill Material Types Using Finite Element Method (유한요소해석을 통한 되메움재 종류에 따른 지하매설관의 변형 특성 연구)

  • Byun, Yoseph;Ahn, Byungje;Kwang, Byeongjoo;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.5
    • /
    • pp.11-18
    • /
    • 2009
  • When underground pipe is installed, backfill materials need proper compaction. But in case of circular underground pipe, compaction of backfill material is difficult and compaction efficiency is poor at beloe the pipe. It caused the stability of underground pipe is reduced and various damages occurred. One of the solutions to solve this problem for underground pipe is to use controlled low strength material (CLSM). CLSM is made by concept of low strength concrete, which is applied to geotechnical engineering field. The representative characteristics of CLSM are self-leveling, self-compacting and flowability. In addition, its strength can be controlled and its construction method is simple. The behavior of underground pipe was investigated by finite element analysis for various backfill materials under same condition. As a result, in case of using the CLSM as backfill material, surface settlement and displacement of pipe are reduced comparing with those in case of using field soil or sand.

  • PDF

Evaluation of correlation between Strain mudulus (Ev2) and Deformation modulus (ELFWD) Using Cyclic Plate loading Test and LFWD (소형 FWD와 반복평판재하시험에서의 변형계수(Ev2)와의 상관관계 평가)

  • Choi, Chan-Yong;Lee, Sung Hyok;Bae, Jae Hun;Park, Doo Hee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.3
    • /
    • pp.33-41
    • /
    • 2011
  • In this study, it conducted a compaction quality control test in 29 domestic construction sites and investigated the relationship between classical method (Cyclic Plate bearing test) and LFWD test with subgrade materials which consist in sandy soil and gravelly soil. According to the test results, the most of soil types were mostly satisfied with specification criterion and gravelly soils were easily satisfied with values over 3 times greater than specification criterion. In term of the correlation relation of soil modulus with the two compaction quality control test methods, it is shown that the sandy soil types were a good correlation, while gravelly soil types with a high stiffness materials were indicated less correlation. After the compensation for stress condition, a linear regression for elastic modulus were higher correlation.

Friction Properties between Fiber-Mixed Soil and Geogrid (섬유혼합토와 지오그리드 사이의 마찰 특성 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;An, Ju-Hwan
    • Journal of the Korean Geosynthetics Society
    • /
    • v.2 no.1
    • /
    • pp.27-37
    • /
    • 2003
  • The factors affecting shear strength and friction characteristics of the fiber-mixed soil can be classified into engineering properties of soil; particle-size, distribution, and particle shape, physical and mechanical properties of fiber; shape, length, diameter, tensile strength, elastic modulus, friction coefficient, and mixed ratio and external factors; confined stress and compaction condition. In this study, a series of shear friction tests and pull-out tests were performed to evaluate the friction properties of fiber-mixed soil according to soil type, fiber type, fiber mixed ratio and compaction degree. The materials and test conditions used in this study are as follows. Soils: SM and ML; mixing fibers: three types of polypropylene fibers(net type 38mm and 60mm, and line type 60mm); reinforcement: geogrid; mixing ratio: 0.2% and 0.3%; degree of compaction : 85% and 95%.

  • PDF