• Title/Summary/Keyword: Compact flash Interface

Search Result 5, Processing Time 0.018 seconds

Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현)

  • Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.678-681
    • /
    • 2003
  • In this paper, we aims to develop a microcontroll er-based portable pulse oximeter using Compact Flash Interface. First, portable pulse oxineter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of SpO$_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patients condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO$_2$ modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact flash interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현)

  • Kim, Dong-Hak;Kim, Young-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

The Study of the Implementation of the Boot System Using CF(Compact Flash) memory card 1. Implementation of the Boot System Using CF memory card (CF(Compact Flash)메모리 카드를 이용한 부트 시스템 구현에 관한 연구 1. CF메모리 카드를 이용한 부트 시스템 구현)

  • 이광철;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.1
    • /
    • pp.108-114
    • /
    • 2004
  • In this paper we propose the boot system using CF memory card and study the system implementation method. The system that is proposed in this paper basically consist of high performance microprocessor, small amount of program memory and CF memory card. And added LCD module and touch panel for the user interface. This system use the CF memory card and DRAM instead of the Flash memory, so it can reduce the system cost. And system performance is increased because of the system program running in the DRAM.

Development of PCM Data Recorder for Telemetry System (원격측정용 PCM 데이터 저장장치 개발)

  • Koh, Kwang-Ryul;Lee, Sang-Bum;Lee, Hyun-Kyu;Kim, Whan-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.607-614
    • /
    • 2011
  • This paper describes the development of pulse code modulation(PCM) data recorder with design, implementation and environmental test. PCM serial data that diverged from telemetry encoder output is used as the input and is reformed to parallel signal through FPGA processing. Controllers construct the packet by the sector and record it into non-volatile memory. Compact flash(CF) memory for data storage media, USB interface for data downloading, and a software for operating status diagnosis and file format conversion are used.

Development of Data Logger System for Ocean Bottom Seimometer (해저면지진계 데이터 기록장치 개발 연구)

  • Hong, Sup;Kim, Hyung-Woo;Lee, Jong-Moo;Choi, Jong-Su
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.336-339
    • /
    • 2003
  • A digital data logging system has been developed for the purpose of a compact offline Ocean Bottom Seismometer(OBS). The Digital Data Logger(DDL) consists of A/D system, Micom with storage memory and firmware managing data files. The A/D system acquires data of 16bit/4ch with sampling rate of 250Hz per channel. The Micom, a micro controller board with T33521 processor of 8051 class, was equipped with 8 flash memories of 128MB for data storage capacity of 1GB. The firmware stores the acquiring data in form of binary files. The DDL was designated to be compact and light and to consume low energy as possible. The DDL is to interface with PC through USB(Universal Serial Bus). The performance of the DDL has been validated through tests with respect to a 3-axis seismometer.

  • PDF