• Title/Summary/Keyword: Communicating

Search Result 1,121, Processing Time 0.03 seconds

Blindness Caused by Wrapping of the ICA Aneurysm

  • Lim, Jae-Kwan;Hwang, Hyung-Sik;Moon, Seung-Myung;Choi, Sun-Kil
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.6
    • /
    • pp.455-458
    • /
    • 2006
  • The incidence of blindness after aneurysm surgery is very rare. We experienced a case of unilateral blindness after internal carotid artery[ICA] aneurysm wrapping. A 43-year-old male immediately developed ipsilateral ocular pain and visual loss in his left eye after the treatment of a lateral ICA aneurysm by wrapping with muscle pieces. He had also multiple aneurysms, which were multilobulated anterior communicating artery [A-com], middle cerebral artery[MCA] and posterior communicating artery [P-com] aneurysms. Coilings were done for a part of A-com artery aneurysm and P-com artery aneurysm on admission. The remaining A-com artery aneurysm was clipped and ICA aneurysm was wrapped with temporal muscle piece. A retrobulbar optic neuropathy might have resulted from either direct injury or damage to small dural vessels of the posterior optic nerve. Actually, the optico-carotid space was tight and the optic nerve was compressed by swollen muscle piece. Despite releasing of compression of the optic nerve on second day, his visual loss was irreversible.

Ideal Internal Carotid Artery Trapping Technique without Bypass in a Patient with Insufficient Collateral Flow

  • Chung, Joon-Ho;Shin, Yong-Sam;Lim, Yong-Cheol;Park, Min-Jung
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.260-263
    • /
    • 2009
  • Internal carotid artery (ICA) trapping can be used for treating intracranial giant aneurysm, blood blister-like aneurysms and ICA rupture during the surgery. We present a novel ICA trapping technique which can be used with insufficient collaterals flow via anterior communicating artery (AcoA) and posterior communicating artery (PcoA). A patient was admitted with severe headache and the cerebral angiography demonstrated a typical blood blister-like aneurysm at the contralateral side of PcoA. For trapping the aneurysm, the first clip was placed at the ICA just proximal to the aneurysm whereas the distal clip was placed obliquely proximal to the origin of the PcoA to preserve blood flow from the PcoA to the distal ICA. The patient was completely recovered with good collaterals filling to the right ICA territories via AcoA and PcoA. This technique may be an effective treatment option for trapping the aneurysm, especially when the PcoA preservation is mandatory.

Process Algebraic Approach to Timing Analysis of Superscalar Processor Programs (프로세스 대수에 기반을 둔 수퍼스칼라 프로세서 프로그램의 시간 분석)

  • Yoo, Hee-Jun;Lee, Ki-Huen;Choi, Jin-Young
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.2
    • /
    • pp.200-208
    • /
    • 2000
  • Multi-ports register could shared several instructions at the same time in read operation. We address a formal methods for describing timing analysis and resource restriction in pipeline super scalar process that having multi-Port registers. First, we specify in-order pipeline instructions, and then, extend timing analysis in out-of-order super-scalar. In this case, we find instruction pairs in any cycle which can execute same time, We use ACSR(Algebra of Communicating Shared Resources), a branch of formal methods based on process algebra, for instruction specification and modelling.

  • PDF

Experiences of Neuroform Stent Applications for Ruptured Anterior Communicating Artery Aneurysms with Small Parent Vessel

  • Yun, Jung-Ho;Cho, Chun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.1
    • /
    • pp.53-58
    • /
    • 2010
  • Objective : The purpose of this study was to review the safety and durability of aneurysms treated with stent-assisted coiling of ruptured anterior communicating artery aneurysms with small parent vessels (< 2.0 mm). Methods : Retrospective review of all ruptured aneurysm treated with stent assisted endovascular coiling between March 2005 and March 2009 at our institution was conducted. We report 11 cases of the Neuroform stent placement into cerebral vessels measuring less than 2.0 mm in diameter (range, 1.3-1.9 mm) in anterior cerebral artery. Clinical follow-up ranged from 3 to 12 months and imaging follow-up was performed with cerebral angiography at 6 months and 12 months after discharge. Results : Complete occlusion was achieved in 10 patients, and a remnant neck was evident in one. No stent displacement or no dislodgement occurred during stent placement. There was no evidence of thromboembolic complication, arterial dissection and spasm during procedure. We performed follow-up angiography in all patients at 6 months and/or 12 months from the first procedure. The follow-up angiographic data showed successfully results except one in-stent stenosis case. All patients improved clinical performances except one patient with severe vasospasm who showed poor clinical condition initially. Conclusion : We have safely and successfully treated 11 vessels smaller than 2.0 mm in diameter with self-expanding stents with good short and intermediate term results. More clinical data with longer follow-ups are needed to establish the role of stent-assisted coiling in ruptured aneurysms with small parent vessels.

Design of the Adaptive SIP Application Server System Architecture supporting SIP-based Session Mobility over the Home Network configured with Private IP (사설IP 기반 홈네트워크에서 세션이동성 지원의 적응적인 SIP 응용서버 시스템 구조 설계)

  • Oh, Yeon-Joo;Beom, Min-Jun;Kim, Dong-Hee;Paik, Eui-Hyun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.1 no.2
    • /
    • pp.73-81
    • /
    • 2006
  • The home network is generally separated from the Internet, as it is made up of a private network due to security issues and the lack of IPv4 addresses space. Also, a user may want to move from a terminal to another terminal connected in the home network during communicating with people outside the home. In this case, people connected in the Internet, or another home network could not communicate the user at the home. These limitations prevent a SIP-capable device connected in the home network from communicating with another SIP-capable device connected in the Internet or the outside of the home network. To overcome the limitations, This paper proposes the Adaptive SIP Application Server System as a software architecture that a user inside of the home can communicate with people outside of the home when the home is composed of a private IP-based network. Moreover, the proposed architecture provides the session mobility that allows the user to maintain a media session even if changing the terminal inside of the home during the session established. The proposed system was implemented over a home server device which acts functionality as a connection point for transmitting IP packets between a home network and the Internet.

  • PDF

Key air pollution problems in the early 21st century

  • Brlmblecombe, Peter
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.5-10
    • /
    • 2003
  • This paper explores not only emerging scientific problems but also the difficulties communicating air quality issues into an increasingly sensitive the public and policy arena. The public understanding and trust in air pollution information and indices may be very different to the notions of validity or accuracy that are important for a scientist. We operate in a world where openness requires us to reveal both the difficulties and disagreements in our understanding of the polluted atmosphere. Yet this can be confusing and increase complexity in situations where clear political and social decisions are required. I am going to examine these issues, starting with questions of what substances we regard as pollutants and the difficulties of getting the correct balance of concern given the broadening the base of chemicals emitted to the environment. There are also questions of exposure particularly in terms of vulnerable populations, who may spend large amounts of time indoors, where air is rarely monitored. In contemporary society there are pollution problems that extend far beyond urban areas and we have to consider regional issues such as windblown dusts, smoke from forest fires along with issues of the emission of green house gases and ozone depleting substances. Finally I will discuss the issues of communicating with a concerned public and sceptical politicians and the troubling interface between technological and sociological control. Such complexity is often missed in a maze of seemingly stronger political and social needs.

  • PDF

A Connection Entropy-based Multi-Rate Routing Protocol for Mobile Ad Hoc Networks

  • Hieu, Cao Trong;Hong, Choong-Seon
    • Journal of Computing Science and Engineering
    • /
    • v.4 no.3
    • /
    • pp.225-239
    • /
    • 2010
  • This paper introduces a new approach to modeling relative distance among nodes under a variety of communication rates, due to node's mobility in Mobile Ad-hoc Networks (MANETs). When mobile nodes move to another location, the relative distance of communicating nodes will directly affect the data rate of transmission. The larger the distance between two communicating nodes is, the lower the rate that they can use for transferring data will be. The connection certainty of a link also changes because a node may move closer to or farther away out of the communication range of other nodes. Therefore, the stability of a route is related to connection entropy. Taking into account these issues, this paper proposes a new routing metric for MANETs. The new metric considers both link weight and route stability based on connection entropy. The problem of determining the best route is subsequently formulated as the minimization of an object function formed as a linear combination of the link weight and the connection uncertainty of that link. The simulation results show that the proposed routing metric improves end-to-end throughput and reduces the percentage of link breakages and route reparations.

Prospect of Communications Customer Premises Technology Considering Home Networking (Home Networking 기술을 고려한 댁내통신설비기술 전망)

  • 이상무;이영환;조평동
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.483-486
    • /
    • 2001
  • Home Networking is the last connection point for global information and telecommunication infrastructure establishment. Information infrastructure has been constructed to matured extent so far, and then the enhancement of data transferring performance and high speed capacity in houses tame to the problem to solve as the last communicating area. In addition, to hold such communicating rapacity in houses, the customer premises technology is important as the framework. In this paper, introducing various home networking technologies, prospect of premise technology is reviewed.

  • PDF

A Study on Multilevel Communication Drive of Full-Duplex Method with Security (보안성을 겸비한 전이중방식의 다중레벨 통신드라이브에 관한 연구)

  • Cho, Su-Eog;Park, Seong-Mi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.1
    • /
    • pp.41-48
    • /
    • 2020
  • Currently, the industry uses MODBUS communication method using RS485 as a communication method used when constructing distributed equipment and networks. However, this method has a rather good transmission and reception distance, but has a disadvantage of being a half-duplex communication method. Therefore, there is a great need for a full-duplex communication method that can simultaneously transmit and receive two-wire communications. Therefore, in this paper, we propose a new communication hardware equipment that can implement full-duplex communication method by communication signal level to overcome the disadvantage of communication speed. The proposed communication hardware is a structure that can transmit and receive at the same time on the same communication line in two equipments communicating in a two-wire system. The characteristic of this communication hardware is that the transmitter generates two-level signal for data transmission, but the receiver generates three-level electric signal according to the status of the transmission data generated by the receiver. The data transmission signal information of the receiver is present at the same time. Therefore, the receiving side can analyze the received signal based on the information on the current transmission signal and can analyze the signal only in the two communicating devices, so it can be seen that the communication security is very excellent.