• 제목/요약/키워드: Common-Mode Filter

검색결과 76건 처리시간 0.026초

고주파용 필터구현을 위한 개선된 CMFB회로를 이용한 CMOS Op-amp 설계 (A CMOS Op-amp Design of Improved Common Mode Feedback(CMFB) Circuit for High-frequency Filter Implementation)

  • 임대성;최영재;이명수;김동용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.479-482
    • /
    • 1993
  • A fully balanced differential amplifier can achieve high-gain wide-bandwidth characteristics. And also, Offset PSRR, CMRR and Noise performance of that are excellent, but these merits can be achieved only when the architecture holds fully balanced. Commonly, the fully balanced differential amplifier has a common mode feedback(CMFB) circuit in order to maintain the balance. This paper presents improved characteristics of the CMFB circuit and designs the wide-bandwidth CMOS Op-amp. The unity gain bandwidth of this Op-amp is 50MHz with the load capacitor 2pF, and the value of phase margin is $85^{\circ}$.

  • PDF

2-5V, 2-4mW, 3차 타원 저역통과 Gm-C 필터 (2-5V, 2-4mW, the third-order Elliptic Low-pass Gm-C Finer)

  • 윤창훈;김종민;유영규;최석우;안정철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(2)
    • /
    • pp.257-260
    • /
    • 2000
  • In this paper, a Gm-C filter for low voltage and low power applications using a fully-differential transconductor is presented. The designed transconductor using the series composite transistors and the low voltage composite transistors has wide input range at low supply voltage. A negative resistor load (NRL) technology for high DC gain of the transconductor is employed with a common mode feedback (CMFB). As a design example, the third-order Elliptic lowpass filter is designed. The designed filter is simulated and examined by HSPICE using 0.25${\mu}{\textrm}{m}$ CMOS n-well parameters. The simulation results show 105MHz cutoff frequency and 2.4㎽ power dissipation with a 2.5V supply voltage.

  • PDF

대전력용 EMC대책 필터의 성능개선에 관한 연구 (A Study or the Improvement of Performance for High power EMC filter)

  • 배대환;김동일;배재영
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2000년도 종합학술발표회 논문집 Vol.10 No.1
    • /
    • pp.75-78
    • /
    • 2000
  • Since the most of malfunctions in the industrial equipment controlled by processors is occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commission(IEC) prepared the dummy signal to test the immunity level of the equipments. In this paper. we designed a new EMC filter for power line in break-box, which is consist of the feed-through capacitor and ferrite materials with high permeability which was wound or inserted in the second layer of the power cable in order to increase common mode inductance. We have obtained a excellent insertion loss characteristics over wide frequency band from 100 KHz up to 6 GHz. It is expected that the new EMC filter could be effectively used for industrial, MIL, and medical equipments to reduce a malfunctions and be suitable for IEC 61000-4-4.

  • PDF

Development of Improved EMC Filter for EFT in Power Supply

  • Bae, Dae-Hwan;Kim, Dong-Il;Song, Jae-Man
    • Journal of electromagnetic engineering and science
    • /
    • 제1권1호
    • /
    • pp.100-104
    • /
    • 2001
  • Since the most of malfunctions in the industrial equipment controlled by processors is consist of the electrical fast transient (EFT)$^{[1],[2]}$TEX>, the International Electrotechnical Commission (IEC) prepared the dummy signal to test the immunity level of the equipments. To work out a countermeasure for the malfunction, We designed a new electromagnetic compatibility (EMC) filter for high power supply, which is consisted of a feed-through capacitor and ferrite materials with high permeability. The ferrite material is surrounded with a power cable or is inserted on the cable’s second layer in order to increase common-mode inductance. We have obtained a excellent insertion loss characteristics over the frequency band from 150 kHz to 30 MHz. The developed new EMC filter satisfy IEC 61000-4-4 and is suitable for industrial, militaly, and medical equipments with reduced malfuntions.

  • PDF

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF

영상기기의 EMC Debugging 기술 (EMC Debugging Technique for Image Equipments)

  • 송민종;김진사
    • 한국전기전자재료학회논문지
    • /
    • 제35권2호
    • /
    • pp.143-148
    • /
    • 2022
  • For the purpose of treating health checkups and recovery of patients in a super-aged society, hospitals use devices designed with a reduction circuit of electromagnetic waves associated with the specific absorption rate of electromagnetic waves absorbed by the human body. In this paper, we proposed a filter improvement design method capable of reducing electromagnetic waves. As a result of confirming the validity of the proposed technique through simulation and experimental results, the following result values were obtained. Applying the common-mode (CM) inductor 4 mH to a calibration circuit, noise decreased in a multiband spectrum. Using the differential mode(DM) inductor 40 µH element in the primary calibration circuit, the noise decreased by 15 dB or more in the 3 MHz band spectrum. Also, applying the Admittance Capacitance (Y-Cap) 10 nF element in the secondary calibration circuit resulted in the decrease by more than 30 dB in the band spectrum before 2 MHz. After using a common-mode inductor 4 mH element in the tertiary calibration circuit, it decreased by more than 15 dB in the band spectrum after 2 MHz.

SNR Improvement of AE Signal for Detection of Gas Leak from Tubes under Vibratory Environment

  • Lee, Tae-Hun;Jhang, Kyung-Young;Kim, Jung-Kyu
    • 비파괴검사학회지
    • /
    • 제27권3호
    • /
    • pp.262-267
    • /
    • 2007
  • Detection of gas leak from a tube is a very important issue in the quality control of machines such as the heat exchanger of an air-conditioner, because leakage of operating gas directly reduces the performance of machines. The acoustic emission (AE) method is a common way to detect leak of gas, however its application under the environment of mechanical vibration is restricted since most AE detectors are very sensitive to external vibration noise. In order to overcome this problem, we propose a method based on the mode analysis of the Lamb wave. In this method, the dominant Lamb mode and its frequency are found first, and then a proper band-pass filter is used to retain only this frequency component. In this way, we could improve the SNR (signal-to-noise ratio) of AE signal generated by gas leak from the tube even under vibratory environment.

전원노이즈 억제용 차폐절연변압기의 설계 및 주파수특성 해석 (Design and Frequency Characteristic Analysis of Shielded Isolation Transformer for the Power Line Noise Reduction)

  • 이재복;허창수;이태호
    • 한국자기학회지
    • /
    • 제9권1호
    • /
    • pp.55-63
    • /
    • 1999
  • AC 전원선로에서 발생하는 수 kHz에서 수십 MHz에 이르는 광대역의 주파수특성을 가진 전원노이즈는 전기, 전자, 통신장비의 정상적인 동작에 많은 장해요소가 되고 있으며 이들 전도성 노이즈를 억제하기 위한 기기로 기존에는 써어지 억제기와 필터가 적용되어 왔다. 그러나, 이러한 기존의 노이즈 대책기기는 전력 공급선과 노이즈 피해회로 상호간의 전기적인 절연 분리가 원천적으로 불가능하므로 전도성 노이즈 중에서 가장 큰 피해를 끼치는 공통모드 노이즈 억제성능이 지극히 제한적이다. 따라서 본 논문에서는 전원회로의 공통모드 및 정상모드 노이즈 억제에 사용 가능한 차폐절연변압기에 대한 모의 등가회로를 제안하였으며, 계산과 실험을 통해 그 성능을 비교 해석함으로써 모의 해석의 유효성을 입증하였다. 또한 차폐절연변압기의 설계 방법을 제시하였으며, 제작된 3kVA급 시작품과 비 차폐된 절연변압기의 노이즈 성능을 비교함으로써 전도성 노이즈 억제성능의 우수성을 검증하였다.

  • PDF

New Strategy for Eliminating Zero-sequence Circulating Current between Parallel Operating Three-level NPC Voltage Source Inverters

  • Li, Kai;Dong, Zhenhua;Wang, Xiaodong;Peng, Chao;Deng, Fujin;Guerrero, Josep;Vasquez, Juan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.70-80
    • /
    • 2018
  • A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter.

Harmonic Suppressed Dual-Band Bandpass Filter with Independently Tunable Center Frequencies and Bandwidths

  • Chaudhary, Girdhari;Jeong, Yongchae;Lim, Jongsik
    • Journal of electromagnetic engineering and science
    • /
    • 제13권2호
    • /
    • pp.93-103
    • /
    • 2013
  • This paper presented a novel approach for the design of a tunable dual-band bandpass filter (BPF) with independently tunable passband center frequencies and bandwidths. The newly proposed dual-band filter principally comprised two dual-mode single band filters using common input/output lines. Each single BPF was realized using a varactor-loaded transmission line resonator. To suppress the harmonics over a broad bandwidth, a defected ground structure was used at the input/output feeding lines. From the experimental results, it was found that the proposed filter exhibited the first passband center frequency tunable range from 1.48 to 1.8 GHz with a 3-dB fractional bandwidth (FBW) variation from 5.76% to 8.55%, while the second passband center's frequency tunable range was 2.40 to 2.88 GHz with a 3-dB FBW variation from 8.28% to 12.42%. The measured results of the proposed filters showed a rejection level of 19 dB up to more than 10 times the highest center frequency of the first passband.