• 제목/요약/키워드: Common rail direct injection

검색결과 101건 처리시간 0.019초

축압식 고압 연료분사펌프 시스템 특성 해석 (Characteristics of a High Pressure Accumulator Type Fuel Injection System)

  • 박석범;구자예
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1101-1110
    • /
    • 1998
  • Computational investigation was conducted to examine the performance of a high pressure common-rail fuel injection system which is used to power a passenger car direct injection (Dl) diesel engine. The pipe flows were modeled by one dimensional wave equation and solved by implicit FDM Each volume of injector was considered as chambers with orifice nozzle in connections. These simulation results were compared with the experimental data of Ganser Hydromag. The comparison of needle life and rate of injection between simulation data and experimental data showed quite a good agreement Different shape of injection rate can be made by adjusting the size of inlet orifice and exit orifice in the piston chamber The pilot injection was accomplished by adjusting command signal.

피에조 인젝터 커먼레일 시스템을 이용한 함산소연료의 분무특성에 관한 연구 (An Investigation on a Spray Characteristics of Oxygenated Fuel with a Piezo Injector Common Rail System)

  • 이세준;양지웅;김상일;임옥택
    • 한국분무공학회지
    • /
    • 제17권4호
    • /
    • pp.171-177
    • /
    • 2012
  • To understand oxygenated fuel characteristics including spray penetration length and spray angle at a real engine ambient pressure condition, DME was injected into a high pressure chamber by a piezo injector common rail system. The piezo injector common rail system was able to apply steady injection pressure, rapid response, and accurate injection quantity. Injection and ambient pressure were varied to confirm a relation with spray form. Using a direct photographing technique, development process of DME spray was captured. DME injection quantity was enlarged linearly as increasing of the injection pressure. In the high pressure chamber, when the injection pressure was enlarged the penetration length and velocity were increased due to a big momentum of fuel particle at the same ambient pressure. When ambient pressure was increased, the DME spray penetration length and velocity were decreased since the high ambient density of nitrogen was acted as a resistance. Although the ambient pressure and injection pressure were varied, each case of spray angle was almost same since the spray angle had a connection of the injector nozzle geometry.

매연여과장치 재생을 위한 커먼레일 디젤엔진의 연소 최적화에 관한 연구 (A Study on the Combustion Optimization of a Common Rail Direct Injection Diesel Engine for Regeneration of the Diesel Particulate Filter)

  • 강중훈;김만영;윤금중
    • 한국자동차공학회논문집
    • /
    • 제13권4호
    • /
    • pp.167-173
    • /
    • 2005
  • Thermal regeneration means burning-off and cleaning-up the particulate matters piled up in DPF(diesel particulate filter), and it requires both high temperature $(550\~600^{\circ}C)$ and appropriate concentration of oxygen at DPF entrance. However, it is not easy to satisfy such conditions because of the low temperature window of the HSDI(high speed direct injection) diesel engine(approximately $200\~350^{\circ}C$ at cycle). Therefore, this study is focused on the method to raise temperature using the trade-off relation between temperature, oxygen concentration, and the influence of many parameters of common rail injection system including post injection. After performing an optimal mapping of the common rail parameters for regeneration mode, the actual cleaning process during regeneration mode is investigated and evaluated the availability of the regeneration mode mapping through regenerating soot trapped in the DPF.

소형 트랙터용 전자제어 직접 분사식 디젤 엔진 고강도 실린더 블록의 설계에 관한 연구 (A Study on Design of High strength Cylinder Block about Common Rail Direct Injection Diesel Engine for Small Tractor)

  • 남석주;박성호;김규태;김귀남
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.649-656
    • /
    • 2023
  • Recently, global warming has become severe, and regulation is established for carbon savings each field. its regulation is applied to various fields using IC engine such as automobile, ship, agricultural machine. Therefore engine block applied Common Rail Direct Injection(CRDI) technology, that carry out thermal-structure analysis to examine design. The thermal load about 900℃ by explosion was applied in cylinder. And pressure about 9 MPa(90 Bar) was applied to structure analysis. As a result, it was the highest at 185.99℃ at the top of cylinder. Static-structure analysis applied thermal load, that was shown maximum equivalent stress at 142.59 Mpa and Maximum principal stress 145.03 MPa, Minimum principal stress -149 MPa. When compare analysis results to material property, it design is safety structurally.

INVESTIGATION OF SHORT INJECTIONS USING STANDARD AND MODIFIED COMMON RAIL INJECTORS

  • Ficarella, A.;Giuffrida, A.;Lanzafame, R.
    • International Journal of Automotive Technology
    • /
    • 제8권2호
    • /
    • pp.155-163
    • /
    • 2007
  • The control of the fuel to be introduced into the combustion chamber under idling and low-load conditions is known to be a problem in Diesel engines, owing to the relatively small fraction of the full-load fuel needed under light loads. Thus, particular attention should be paid to the behavior of the injector with reference to short injection events. This work presents the results of an experimental campaign carried out with two different types of common rail injectors, a standard injector and a modified one. The latter, coming from a simple modification realized in a standard injector, exhibits linear behavior between injected fuel and solenoid energizing time in the field of short injections. A direct comparison of the two injection behaviors suggests a possible way to better control short or pilot injections.

직접분사식 압축착화 디젤엔진의 분사시기 변화에 따른 연소 및 성능특성에 관한 연구 (A Study on the Combustion and Performance Characteristics in Compression Ignition CRDI Diesel Engine)

  • 김기복;김치원;윤창식
    • 한국산업융합학회 논문집
    • /
    • 제19권1호
    • /
    • pp.31-38
    • /
    • 2016
  • Since the oil shock of 1970's there was a strong upward tendency for the use of the high viscosity and poorer quality fuels. Therefore the misfiring engine occurs due to the decrease of quantity injected for lean burn and emission control in Compression Ignition Common Rail Direct Injection diesel engine. In this study, it is designed and used the test bed which is installed with fuel injector controller. In addition to equipped engine using CRDI by controlling the injection timing with mapping modulator, it has tested and analyzed the engine performance and combustion characteristics, as it is varied that they are the operating parameters: fuel injected quantity, engine speed and injection timing.

HSDI Common-Rail 인젝터 모델링 및 니들 변위 추정에 관한 연구 (A Study on the Model of an HSDI Common-Rail Injector and the Estimation of Needle Lift)

  • 성경훈;박승범;선우명호;나형규
    • 한국자동차공학회논문집
    • /
    • 제10권1호
    • /
    • pp.59-66
    • /
    • 2002
  • This paper presents the process of the needle lift estimation ova common-rail injector fur HSDI(High Speed Direct Injection) diesel engines. A nonlinear mathematical model of dynamic behaviors of common-rail injector is established at first. Based on the mathematical model of the common-rail injector, the methodology of estimating the injector needle lift is introduced. A sliding mode observer is applied to overcome the model uncertainties. The common-rail injector model and the needle lift estimator are verified by simulations and experiments. The simulation and experimental results indicate that the model outputs are in a good agreement with experimental data, and the proposed nonlinear sliding observer can effectively estimate the needle lift.

예혼합 압축 착화 엔진용 고압 인젝터의 분무특성과 분사조건 최적화에 관한 기초 연구 (The basic study of spray characteristics and optimal fuel injection for high pressure injector in homogeneous charge compression ignition engine)

  • 류재덕;김형민;이기형;이창식
    • 한국분무공학회지
    • /
    • 제9권1호
    • /
    • pp.30-36
    • /
    • 2004
  • The purpose of this study was to investigate the fuel spray characteristics that made most important at an homogeneous air fuel mixture, in a common rail direct injection type HCCI engine. As a study conducted relation which a back pressure and injection pressure are influenced to air fuel mixture characteristics, we tried to offer date even through we select suitable to a HCCI engine running condition of the fuel injection condition. To accomplish the study, to measure a injection rate of common rail type injector and to visualize and simulate a fuel spray was conducted. From the result of injection rate, a common rail injector was confirmed to appear a initial delay of 0.3msec and a latter period delay of 0.7msec. Therefore, real injection duration was determined by about 0.5msec increasing. From the result of fuel spray, the spray penetration was proportional to 1/4 exponent of atmosphere pressure. An experimental equation was deduced from the spray penetration of spray visualization experiment and the relation of injection duration and penetration was estimated in HCCI engine using an experimental equation.

  • PDF

분사조건에 따른 커먼레일 디젤 인젝터의 분사율 특성에 관한 연구 (A Study on the Characteristics of Injection-rate at Different Injection Conditions in a Common-rail Diesel Injector)

  • 김형민;정재우;이기형
    • 한국분무공학회지
    • /
    • 제12권3호
    • /
    • pp.166-171
    • /
    • 2007
  • Recently, many studies on HSDI diesel engines have been performed to reduce the fuel consumption and $CO_2$ emission. One of the prominent technique to reduce emission is a high pressure multiple injection. For this technique, the injection rate is a critical parameter in order to determine precise injection duration and timing for combustion control. Thus the purpose of this study was to investigate relationship between the injection rate and the time-signature of chamber pressure at different injection pressure conditions in a common rail direct injection type injector using the Zeuch method. Using the measured correlation constants, estimated fuel injection rates are presented at many different injection conditions.

  • PDF

커먼레일 분사장치를 이용한 Dimethyl Ether와 디젤연료의 연소특성 (Combustion Characteristics of Dimethyl Ether (DME) and Diesel Fuel Using a Common-rail Fuel Injection System)

  • 최욱;이주광;배충식
    • 한국자동차공학회논문집
    • /
    • 제12권6호
    • /
    • pp.30-37
    • /
    • 2004
  • The combustion and emission characteristics of a direct injection CI engine fuelled with DME(Dimethyl Ether) and diesel fuel were compared at idle engine speed(800 rpm) with various injection parameters. An optical single cylinder diesel engine equipped with a common-rail fuel injection system was constructed to investigate combustion processes of DME and diesel fuel. The combustion images were recorded with a high-speed video camera system. The results demonstrated that the DME-fuelled engine was superior to the conventional diesel engine in terms of engine performance and emissions. The optimal injection timing of DME was located around IDC(Top Dead Center), which was roughly same as that of diesel fuel. As the injection timing was advanced much earlier than TDC, NOx (Nitric Oxides) level increased considerably. NOx emission of DME was equal or a little higher than that for diesel fuel at the same injection pressure and timing because of higher evaporation characteristics of DME. Throughout all experimental conditions, DME did not produce any measurable smoke level.