• 제목/요약/키워드: Common load

검색결과 601건 처리시간 0.03초

웹 클러스터 구성을 위한 시뮬레이션 분석 (Simulation Analysis for Configuring Web Clusters)

  • 강성열;송영효
    • 디지털융복합연구
    • /
    • 제6권2호
    • /
    • pp.117-125
    • /
    • 2008
  • High-volume web sites often use clusters of servers with load balancing as a way to increase the performance, scalability, and availability of the sites. Load balancing, usually performed by load balancer in front of such clusters, is a technique to spread workload between several computers or resources, in order to get optimal resource utilization or response time. In this paper we examine the performance for several configurations of cluster-based web servers using a simulation approach. We investigate two types of buffering scheme (common and local) for web clusters and three load balancing policies (uniformly random, round robin, and least queue first), using response time as a performance measure. We also examine two basic approaches of scaling web clusters: adding more servers of same type or upgrading the capacity of the servers in the clusters.

  • PDF

정적 수평하중에 의한 경량벽체의 최대변형량 허용기준에 관한 연구 (Permissible Criteria of the Stiffness of Lightweight Wall by the Horizontal Static Load)

  • 송정현;김기준;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.204-205
    • /
    • 2014
  • Among common test methods of assessing structure safety for existing lightweight walls, the criteria of the quality assessment of the horizontal static load resistance has been considered ambiguous. In the current study, therefore, an experiment was conducted to figure out the standardized assessment criteria of the lightweight wall's horizontal static load resistance. Based on the findings of the experiment with gypsum board and ALC block walls, an acceptable amount of each standard and the variables of the stud wall arising from the appropriate load (1000N) on the wall in a daily life were accounted for, arbitrarily setting the maximum deformation amount below 15mm.

  • PDF

자동차 냉방부하 계산 및 초기 냉방성능 시뮬레이션 (Computer simulation of cooling load and cool-down performance in an automotive air-conditioning system)

  • 오상한;이창원;원성필
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.364-375
    • /
    • 1997
  • The fundamental theory and technical approach to aid design and development of an automotive air-conditioning system are presented. The evaluation methods for transient cooling load transferred to a passenger compartment and simulation of automotive air-conditioning components are outlined. The structure of the computer program, the experiemntal correlations, and the simulation results are also included. The total cooling load of the white-colored car is reduced upto 5% for that of the black-colored car when the car is running. Using the infrared reflectance glass, we can also obtain 5% reduction of the total cooling load for the common glass.

  • PDF

다중 균열 보강 판재에 관한 파괴 역학적 해석 (Fracture Mechanics Analysis of Multiple Load Path Plate)

  • 한문식;이양섭
    • 한국정밀공학회지
    • /
    • 제18권10호
    • /
    • pp.109-115
    • /
    • 2001
  • The compliance approach to the problem of load sharing between a cracked plate and multiple plate used to bridge the crack. The theory is validated by using calculated stress intensity factors for the multiple load path plate to reduce experimentally observed growth rate to a common base. Calculations are them made on the effect of multiple load path plate width on fatigue crack retardation in order to demonstrate the predictive capability of the technique.

  • PDF

A Simplified Control Algorithm for Three-Phase, Four-Wire Unified Power Quality Conditioner

  • Singh, Bhim;Venkateswarlu, P.
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a simplified control algorithm for a three-phase, four-wire unified power quality conditioner (UPQC) is presented to compensate for supply voltage distortions/unbalance, supply current harmonics, the supply neutral current, the reactive power and the load unbalance as well as to maintain zero voltage regulation (ZVR) at the point of common coupling (PCC). The UPQC is realized by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The shunt AF is realized using a three-phase, four leg voltage source inverter (VSI) and the series AF is realized using a three-phase, three leg VSI. A dynamic model of the UPQC is developed in the MATLAB/SIMULINK environment and the simulation results demonstrating the power quality improvement in the system are presented for different supply and load conditions.

소형 트랙터용 전자제어 직접 분사식 디젤 엔진 고강도 실린더 블록의 설계에 관한 연구 (A Study on Design of High strength Cylinder Block about Common Rail Direct Injection Diesel Engine for Small Tractor)

  • 남석주;박성호;김규태;김귀남
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.649-656
    • /
    • 2023
  • Recently, global warming has become severe, and regulation is established for carbon savings each field. its regulation is applied to various fields using IC engine such as automobile, ship, agricultural machine. Therefore engine block applied Common Rail Direct Injection(CRDI) technology, that carry out thermal-structure analysis to examine design. The thermal load about 900℃ by explosion was applied in cylinder. And pressure about 9 MPa(90 Bar) was applied to structure analysis. As a result, it was the highest at 185.99℃ at the top of cylinder. Static-structure analysis applied thermal load, that was shown maximum equivalent stress at 142.59 Mpa and Maximum principal stress 145.03 MPa, Minimum principal stress -149 MPa. When compare analysis results to material property, it design is safety structurally.

스프링하중을 고려한 디젤차량용 오버플로우 밸브 성능평가 (Overflow Valve and Performance Evaluation System for Diesel Cars based on Spring Load)

  • 윤달환
    • 전기전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.200-204
    • /
    • 2016
  • 본 연구에서는 유로형(EURO type) 클린 디젤 CRDI(common rail direct injection) 엔진용 오버플로우 밸브 성능 평가 시스템을 구현한다. 친환경 조건에 맞도록 정밀 기능을 구비한 오버플로우를 위해 스프링의 하중을 고려한 구현이 중요하다. 특히 정밀제어에 따른 디젤 차량의 성능평가는 연비 향상과 환경 규제 만족이 필연적이다. 이에 성능평가를 위한 평가 알고리즘의 기본 조건은 100cc 미만에서 3.0 bar, 150 cc 이상에서 3.3 bar, 250 cc이상에서 4.0 bar를 사용하여 시험한다.

Vortex Tube의 승용 디젤기관 배기가스 온도 분리특성에 관한 연구 (An Experimental Study on Characteristics of Temperature Separation in a Vortex Tube for Diesel Engine Exhaust Gas)

  • 정영철;최두석;임석연;김홍주;류정인
    • 한국자동차공학회논문집
    • /
    • 제18권1호
    • /
    • pp.93-98
    • /
    • 2010
  • An object of this study is to confirm the opening amount of the throttle valve that is begun the temperature separation of vortex tube for various engine speed and load condition in a common rail diesel engine. The vortex tube located at downstream of the exhaust manifold is a device separating the incoming exhaust gas to hot and cold stream. To find optimum separation efficiency of vortex tube, the opening amount of throttle valve has been investigated for various engine speed and load conditions. Engine speed was found that the influence of engine speed was dominant compared with that of engine load. As engine speed was increased, the throttle opening amount starting temperature separation was reduced.

로타리 경운날의 개량 연구 -경운날 3종의 경운부하특성 분석 - (Study on the Improvement of Rotary Blade - Tilling Load Characteristic Analysis of the Three Kinds of Rotary Blade -)

  • 김수성;이여성;우종구
    • Journal of Biosystems Engineering
    • /
    • 제22권4호
    • /
    • pp.391-400
    • /
    • 1997
  • Using the soil bin systems, this study was carried out to investigate the tilling load characteristic for the three kinds of Japanese rotary blade and the possibility of common use for power tiller and tractor rotary. The results obtained from the study are summarized as follows : 1. At all tested soils. the average and maximum tilling torque of all tested blades increased as the tillage pitch did. 2. The torque requirements of newly designed and produced blade was less than that of blade which has been used on power tiller and tractor rotary. 3. The maximum tilling torque of new ONE were decreased 7%, 10~11%, 27% in comparing with another blades at clay loam, loam and sandy loam, respectively. 4. According to observation of the extent of soil adhesion on blade and the contact aspect of blade, new ONE is the most excellent of all tested rotary blades and till smoothly not to compress the untilled soil. From the results of this study. the newly developed blade(new ONE) proved to be good tilling load performance and had a conclusion that it is possible to use it on power tiller and tractor rotary in common.

  • PDF

Correlation of wind load combinations including torsion on medium-rise buildings

  • Keast, D.C.;Barbagallo, A.;Wood, G.S.
    • Wind and Structures
    • /
    • 제15권5호
    • /
    • pp.423-439
    • /
    • 2012
  • Three common medium- rise building forms were physically tested to study their overall wind induced structural response. Emphasis was placed on the torsional response and its correlation with other peak responses. A higher correlation was found between the peak responses than between the general fluctuating parts of the signals. This suggests a common mechanism causing the peak event, and that this mechanism is potentially different to the mechanism causing the general load fluctuations. The measurements show that about 80% of the peak overall torsion occur simultaneously with the peak overall along wind drag for some generic building shapes. However, the peak torsional response occurs simultaneously with only 30%-40% of the peak overall drag for the rectangular model. These results emphasise the importance of load combinations for building design, which are often neglected in the design of medium sized rigid buildings for which the along-wind drag is dominant. Current design wind loading standards from around the world were evaluated against the results to establish their adequacy for building design incorporating wind-induced torsion effects. Although torsion is frequently neglected, for some structural systems it may become more important.