• Title/Summary/Keyword: Common Glass

Search Result 181, Processing Time 0.026 seconds

Optical design of a projection lens for high definition digital TV (고화질 프로젝션 디지털 TV용 광학렌즈 설계)

  • 박성찬;문희종
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.291-299
    • /
    • 1998
  • In the rear projection TV, the optimal system configurations of optical parts are presented, which are focused on competitive price and performances. From the initial design with five Seidel aberrations free, aspherization of the plastic lenses, and optimization with tolerances, a new lens consisting of two plastic and one glass lenses was designed. It is able to be used on current broadcast standard NTSC and digital TV in common. The developed CRT-lens assembly could display the 40 to 50 inch image and its resolution is more than 800 TV-lines.

  • PDF

Characteristics of Films Based on Chitosans Isolated from Todarodes pacificus

  • Chung, Dong-Hwa;Kim, Sang-Moo;Kim, Won-Tae;Shin, Il-Shik;Park, Hoon
    • Food Science and Biotechnology
    • /
    • v.14 no.3
    • /
    • pp.433-436
    • /
    • 2005
  • Chitosans were obtained with varying deacetylation times using the ${\beta}$-chitin isolated from Todarodes pacificus, and their deacetylation degrees and average molecular weights were determined. Films prepared with the squid chitosans were characterized by estimating their tensile strengths, percent elongations, water vapor permeabilities, degree of swelling, and temperatures of glass transition and thermal decomposition. The results suggest that the squid chitosan films were comparable to common crustacean chitosan films in regard of mechanical, moisture barrier, and thermal properties, although further, multilateral investigations are necessary to make a more definitive conclusion.

New Polyarylates Prepared from 2,5-Bis($\alpha$-phenylisopropyl)hydroquinone, Terephthalic Acid and Isophthalic Acid

  • 진정일;유승주
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.1
    • /
    • pp.17-21
    • /
    • 1995
  • A new series of polyarylate copolyesters were prepared by melt polycondensation of 1,4-diacetoxy-2,5-(α-phenylisopropyl)benzene with mixture of terephthalic acid and isophthalic acid in varying ratio. And their general properties such as the glass transition temperature, crystalline melting temperature, crystallinity and solubility were studied. The intrinsic viscosity values of the present polymers measured in a mixed solvent of phenol/p-chlorophenol/1,1,2,2-tetrachloroethane ranged from 0.45 to 0.66 depending on the composition and molecular weight. The copolyesters containing greater than 20 mole % of isophthalic acid were found to be amorphous, whereas the homopolymer derived from terephthalic acid was semicrystalline with a melting point of 414℃. The glass transition temperatures of the polymers ranged from 165 to 180℃ depending on the composition. The copolyesters containing 50 mole % and greater of isophthalic acid moiety were soluble at room temperature in such common solvents as tetrahydrofuran, chloroform and N,N-dimethylformamide.

The effect of acidic drinks on the surface of tooth-colored restorative materials (산성음료가 치아색 수복재의 표면에 미치는 영향)

  • Bang, Seok-Yun;Kim, Eun-Jung;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.469-481
    • /
    • 2006
  • Among the etiologic factors of enamel corrosion, daily intake has been considered with a profound interest, especially the intake of acidic drinks. It is thought that the rapid consumption of acidic drinks will not only results in the affection to the teeth but also to the surface of the tooth-colored restorative materials. Therefore, the puopose of this study is to examine the alterations occurred in the surface of the tooth-colored materials according to the exposed time, with 3 most common acidic drinks in contact with daily life. Resin-modified glass-ionomer, polyacid-modified composite resin, composite resin were immersed on 0.9% NaCl, Coke, orange juice, sports beverages as 4 groups in each. The surface hardness and the surface roughness of specimens were measured with following methods: before immersion, 1 day after immersion, 1-,2-,3-,4- weeks after immersion. Results were as follows. 1. Tooth-colored restorative materials, with the exception of composite resin, showed statistically significant changes in surface hardness and roughness when immersed on acidic drinks(p<0.05). 2. The degree of change in surface hardness and roughness occurred as follows, in order of severity from greatest to least resin-modified glass-ionomer, polyacid-modified composite resin, composite resin 3. Sports beverages resulted in greater alterations to surfaces than Coke and orange juice. 4. In the SEM image of the groups immersed in acidic drinks, resin-modified glass-ionomer and polyacid-modified composite resin showed loss of filer. Severe cracks were observed, especially on the resin-modified glass-ionomer.

  • PDF

Solar Module with a Glass Surface of AG (Anti-Glare) Structure (연요철(Anti-Glare) 구조의 표면 유리 기판을 가지는 고효율 태양전지 모듈)

  • Kong, Dae-Young;Kim, Dong-Hyun;Yun, Sung-Ho;Bae, Young-Ho;Yu, In-Sik;Cho, Chan-Seob;Lee, Jong-Hyun
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.3
    • /
    • pp.233-241
    • /
    • 2011
  • Currently, solar module is using the two methods such as a glass-filled method or a super-straight method. The common point of these methods is to use glass structure on the front of solar module. However, the reflectance of the solar module is high depending on the height of the incident sunlight due to the flat surface of the module front glass. Purposed to solve these problems, AG (anti-glare) structures were formed on the glass surface. Next is fabrication methods of AG structure. First, uneven structure made by micro blaster equipment was dipped in Hydro-fluidic acid (HF) acid. HF acid process was carried out to remove particles and to make high transmittance. The reflectance and transmittance of the anti-glare glass was compared to those of the bare glass. The reflectance of anti-glare glass decreased approximately 1% compared with bare glass. The transmittance of anti-glare glass was similar to bare glass. According to the sample angle, the difference of the reflectance between bare glass and the anti-glare glass was about 19%. Isc and efficiency value of anti-glare glass on bare solar cell appeared about 3.01 mA and 0.228% difference compared with bare glass. Anti-glare glass on textured solar cell appeared about 9.46 mA and 0.741% difference compared with bare glass. As a result, the role of anti-glare in the substrate is to reduces the loss of sunlight reflected from the surface. In this study, therefore, AG structure on the solar cell was used to improve the efficiency of solar cell.

Health Assessment for Glass Fibre Landfill at Gozan-dong, Inchon (인천시 고잔동에서 제기된 유리섬유에 의한 건강피해 역학 조사)

  • Cho, Soo-Hun;Ju, Yeong-Su;Kim, Kyung-Ryul;Lee, Kang-Kun;Hong, Kug-Sun;Eun, Hee-Chul;Song, Dong-Bin;Hong, Jae-Woong;Kwon, Ho-Jang;Ha, Mi-Na;Han, Sang-Hwan;Seong, Joo-Heon;Kang, Jong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.77-101
    • /
    • 1997
  • In September 1994, residents of Gozan-dong, Incheon City, made a petition to the government about their health problems which might be caused by previous glass fibre landfill nearby 'H' company. In february 1995, at regular academic meeting of occupational and environmental medicine, a research team of 'D' University presented that they had found glass fibres in groundwater of the area through their survey. They were suspicious of probable association between ingestion of groundwater contaminated with glass fibres and skin tumors among residents. A joint research team was formed and carried out the survey of environment concerning groundwater and its glass fibre existence, and health assessment of residents in the area and industrial workers of 'H' company during May to November, 1995. Analysis of groundwater flow system indicates that the flow lines from the glass fibre landfill pass through or terminate at the 6 houses around the landfill. This means that the groundwater of the 6 houses around the glass fibre landfill could be affected by some possible contaminants from the landfill, but the groundwater quality of the other houses was irrelevant to the landfill. The qualitative and qualitative analyses for glass fibres in 54 groundwater samples including those from the nearby 6 houses, were carried out using SEM equipped with EDS, resulting in no evidence for the presence of glass fibres in the waters. Major precipitates, formed in waters while boiling, were identified as calcium carbonates, in particulary, aragonites in needle form. The results of health assessments of 889 residents in Gozan-dong, participated in this study, showed statistically significant differences in past medical histories of skin tumor and respiratory disease between the exposed group (31 persons who inhabited in 6 houses around the landfill) and the control group, but no significant differences in past medical histories of other diseases, such as cancer mortality, current gastroscopic findings, current skin diseases and respiratory diseases, etc. Also, we could not prove any glass fibres in excised specimens of 9 skin tumors in both groups and there were no health problems possibly associated with glass fibres in employees of the 'H' company. After all, we could not authenticate the association, raised by prior investigators, between groundwater streams, assumedly contaminated with glass fibres or not, and specific disease morbidities or common disease/symptom prevalences. That is, we could not find any glass fibres in groundwater as the only exposure factor of this study hypothesis, and there were not enough certain evidences such as increasing disease prevalences, for examples, skin, respiratory and gastrointestinal diseases etc, possibly related to glass fibre exposure, in exposed group. As a matter of course, the conditions for confirming causal association, for example, strength of the association, consistency of the association, specificity of the association, temporality of the association and dose-response relationship etc, have not been satisfied. In conclusion, we were not able to certify the hypothesis that contamination of groundwater with glass fibres might cause any hazardous health effects in residents who used it for drinking.

  • PDF

Effect of Lu3Al5O12:Ce3+ and (Sr,Ca)AlSiN3:Eu2+ Phosphor Content on Glass Conversion Lens for High-Power White LED

  • Lee, Hyo-Sung;Hwang, Jong Hee;Lim, Tae-Young;Kim, Jin-Ho;Jeon, Dae-Woo;Jung, Hyun-Suk;Lee, Mi Jai
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.4
    • /
    • pp.229-233
    • /
    • 2015
  • Currently, the majority of commercial white LEDs are phosphor converted LEDs made of a blue-emitting chip and YAG yellow phosphor dispersed in organic silicone. However, silicone in high-power devices results in long-term performance problems such as reacting with water, color transition, and shrinkage by heat. Additionally, yellow phosphor is not applicable to warm white LEDs that require a low CCT and high CRI. To solve these problems, mixing of green phosphor, red phosphor and glass, which are stable in high temperatures, is common a production method for high-power warm white LEDs. In this study, we fabricated conversion lenses with LUAG green phosphor, SCASN red phosphor and low-softening point glass for high-power warm white LEDs. Conversion lenses can be well controlled through the phosphor content and heat treatment temperature. Therefore, when the green phosphor content was increased, the CRI and luminance efficiency gradually intensified. Moreover, using high heat treatment temperatures, the fabricated conversion lenses had a high CRI and low luminance efficiency. Thus, the fabricated conversion lenses with green and red phosphor below 90 wt% and 10 wt% with a sintering temperature of $500^{\circ}C$ had the best optical properties. The measured values for the CCT, CRI and luminance efficiency were 3200 K, 80, and 85 lm/w.

Provenance Study on Ancient Lead Glass Relics Using a Lead Isotope Ratio (납동위원소비를 이용한 고대 납유리 유물의 산지추정)

  • Han, Min Su;Kim, So Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.187-193
    • /
    • 2015
  • The purpose of the present study is to trace the provenance of lead raw materials using the lead isotope ratio of 9 lead glasses excavated from the Sarira hole of Mireuksaji stone pagoda and to determine correlation between them and other lead glasses excavated from the Wanggungri site. The results of chemical analysis of the 9 lead glasses show that they are common lead glass system($PbO-SiO_2$) with respect to the contents of PbO (70 wt.%) and $SiO_2$ (30 wt.%). The lead isotope ratios of them plot to northern Korean peninsula when applied to the distribution map of lead isotopes of East Asia. On the other hand, southern Korean peninsula is verified as the main deposits of the lead ore in the distribution map of lead isotopes of South Korea. With respect to the results, it is notable that the provenance of the 9 lead glasses can be very different depending on the distribution map. In addition, a comparative study between them and the lead glasses excavated from the Wanggungri which was built in the same region and period shows that their lead isotopes are highly correlated.

Analysis of Patient Exposure dose with Glass Dosimeter (Glass Dosimeter를 이용한 환자피폭선량에 관한 분석)

  • Kim, Jae-In;Choi, Won-Keun;Chang, Sung-Won;Oh, Chang-Seop;Lee, Kwan-Sup;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • Far reducing medical radiation exposure and managing patient doses, Entrance surface doses(ESDs) were measured at Diagnostic Radiology Department in ASAN medical center, also we determined and compared with the Diagnostic Reference Level(DRL) of some other countries. ESDs were measured far the most common types of X-ray procedures, such as chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA. ESDs were measured by Glass dosimeter and Unfors Xi meter. Those were applied collimation center of phantom's entrance skin surface. The results of ESDs were compared Glass dosimeter with Unfors Xi meter. Those were measured within 5% statistical difference. It seemed well agreement at two devices. In most cases ESDs measured far the different types of X ray procedures were found to be lower than the DRL of IAEA, but ESDs on chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA were proximity ar excesses at DRL of advanced country. Through this study, we need an investigation and improvement at present diagnostic radiology exam system. Also, radiologists make an effort to reduce patient dose and having a technical skill.

  • PDF

A Study on the Warpage of Glass Fiber Reinforced Plastics for Part Design and Operation Condition: Part 2. Crystalline Plastics (유리섬유로 보강된 수지에서 제품설계 및 성형조건에 따른 휨의 연구: Part 2. 결정성 수지)

  • Lee, Min;Kim, Hyeok;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.677-684
    • /
    • 2012
  • Injection molding process is a popular polymer processing involving plasticizing and enforcing the material flow into the mold. A polymer material shrinks according to temperature variations during the shaping process, and subsequently molding shrinkage developed. Developed deflections or warpages after molding process in part are caused by residual stress relaxation contained in the part. Adding inorganic materials or fibers such as glass and carbon to control shrinkage and enhance warpage resistance are common. In this study, warpages according to part design have been investigated through experiment. Warpages for molding conditions and mold designs such as gate locations were measured. Warpages along flow direction and perpendicular to the flow direction were also measured. Warpages near gate and far from gate were compared. Glass fiber reinforced crystalline polymers, PP and PA66 have been used in this experiment. Glass fiber reinforced crystalline polymers showed large warpage compared with glass reinforced amorphous polymers. Warpages in crystalline polymers were less influenced by molding conditions compared with amorphous polymers, however warpages of crystalline polymers significantly depend on part design.