• Title/Summary/Keyword: Common Electrode

Search Result 172, Processing Time 0.026 seconds

Effects of Phase Difference between Voltage loaves Applied to Primary and Secondary Electrodes in Dual Radio Frequency Plasma Chamber

  • Kim, Heon-Chang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.2 s.11
    • /
    • pp.11-14
    • /
    • 2005
  • In plasma processing reactors, it is common practice to control plasma density and ion bombardment energy by manipulating excitation voltage and frequency. In this paper, a dually excited capacitively coupled rf plasma reactor is self-consistently simulated with a three moment model. Effects of phase differences between primary and secondary voltage waves, simultaneously modulated at various combinations of commensurate frequencies, on plasma properties are investigated. The simulation results show that plasma potential and density as well as primary self-dc bias are nearly unaffected by the phase lag between the primary and the secondary voltage waves. The results also show that, with the secondary frequency substantially lower than the primary frequency, secondary self·do bias remains constant regardless of the phase lag. As the secondary frequency approaches to the primary frequency, however, the secondary self-dc bias becomes greatly altered by the phase lag, and so does the ion bombardment energy at the secondary electrode. These results demonstrate that ion bombardment energy can be more carefully controlled through plasma simulation.

  • PDF

Detecting gold by voltammetric handhold systems

  • Kim, Nack-Joo;Choi, Dal-Woong;Yoo, Hai-Soo;Lee, Kyung;Lee, Chang-Hyun;Ly, Suw-Young;Kim, Tae-Yun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.472-477
    • /
    • 2014
  • A voltammetric investigation of Au assay was conducted at a low cost, using Nafion and DNA immobilized on a graphite Pencil working electrode (NDP) with a black lead counter and reference. The following optimal parameters were found: 0.4 V amplitude, 500 Hz frequency, -0.7 V initial potential, and 0.015 V increment potential. These optimal conditions were also applied to sand obtained from the river site. The aforementioned technique is simpler and less costly compared to the common voltammetry and spectrophotometric methods.

Hybrid Energy Storage Mechanism Through Solid Solution Chemistry for Advanced Secondary Batteries (고성능 이차 전지용 하이브리드 에너지 저장 메커니즘을 위한 고용체 화학)

  • Sion Ha;Kyeong-Ho Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.1
    • /
    • pp.11-25
    • /
    • 2024
  • Lithium-ion batteries (LIBs) have attracted great attention as the common power source in energy storage fields of large-scale applications such as electrical vehicles (EVs), industries, power plants, and grid-scale energy storage systems (ESSs). Insertion, alloying, and conversion reactions are the main electrochemical energy storage mechanisms in LIBs, which determine their electrochemical properties and performances. The electrochemical reaction mechanisms are determined by several factors including crystal structure, components, and composition of electrode materials. This article reviews a new strategy to compensate for the intrinsic shortcomings of each reaction mechanism by introducing the material systems to form a single compound with different types of reaction mechanisms and to allow the simultaneous hybrid electrochemical reaction of two different mechanisms in a single solid solution phase.

MOF-based Sensing Materials for Non-enzymatic Glucose Sensors

  • Jingjing Liu;Xiaoting Zha;Yajie Yang
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.32-50
    • /
    • 2024
  • Diabetes mellitus is one of the common chronic diseases, seriously threating to human health. The continuous monitoring of blood glucose concentration can effectively prevent diabetic diseases. The sensing performance of glucose non-enzymatic sensors is mainly determined by working electrode materials. Metal-organic frameworks (MOFs) are recognized as promising candidate for glucose sensor application, due to its large surface areas, ordered porous structure and nearly infinite designability. In this review, the sensing performance, research progress and future challenge of non-enzymatic glucose sensors based on MOF-based materials in recent years are presented. We hope that this review would provide valuable technology guidance for high performance non-enzymatic glucose sensors based on MOFs.

Effect of NEES on the Occurrence of c-Fos in the Cerebrum of a Rat With Transient Global Ischemia (일과성 전뇌허혈 유발 쥐의 침전극 저주파자극 후 대뇌의 c-Fos 발현에 미치는 영향)

  • Lee, Jung-Sook;Kim, Sung-Won
    • Physical Therapy Korea
    • /
    • v.17 no.1
    • /
    • pp.69-76
    • /
    • 2010
  • Ischemia that causes stroke induces inflammation of brain cells and apoptosis and as a result, it influences much on the functional part of a man. The needle electrode electrical stimulation (NEES) that combines acupuncture of oriental medicine with electric therapy of western medicine relieves inflammation of cells and has effect on regrowth of nerve tissues. This study was conducted to verify the influence of NEES on the occurrence of c-Fos of cerebrum after applying NEES to the meridian point, Zusanli (ST 36) of a rats with induced ischemia. Global ischemia was induced by using ligation method on common carotid artery of male Sprague Dawley (SD) rats. The ligation was maintained for 5 minutes and then suture was removed for blood reperfusion. After inducing global ischemia, NEES was done to the left and right meridian points of Joksamri of a rat for 30 minutes after 12 hours, 24 hours, and 48 hours. The findings were as follows. 1. In the result of immunohistochemical method, the number of c-Fos immune response cells significantly decreased (P<.05) in NEES group than the control group (GI) that did not get NEES. 2. In the result of western blotting, the occurrence of c-Fos after 24 hours from the inducement of ischemia significantly decreased (P<.05) in NEES group than the control group (GI) that did not get NEES. Therefore, as the effect of NEES was shown highest after 24 hours from the ischemia, it is suspected that NEES would take important role in early treatment after cerebral stroke.

Development of a Tactile Sensor Array with Flexible Structure Using Piezoelectric Film

  • Yu, Kee-Ho;Kwon, Tae-Gyu;Yun, Myung-Jong;Lee, Seong-Cheol
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1222-1228
    • /
    • 2002
  • This research is the development of a flexible tactile sensor array for service robots using PVDF (polyvinylidene fluoride) film for the detection of a contact state in real time. The prototype of the tactile sensor which has 8${\times}$8 array using PVDF film was fabricated. In the fabrication procedure, the electrode patterns and the common electrode of the thin conductive tape were attached to both sides of the 281$\mu\textrm{m}$ thickness PVDF film using conductive adhesive. The sensor was covered with polyester film for insulation and attached to the rubber base for a stable structure. The proposed fabrication method is simple and easy to make the sensor. The sensor has the advantages in the implementing for practical applications because its structure is flexible and the shape of the each tactile element can be designed arbitrarily. The signals of a contact force to the tactile sensor were sensed and processed in the DSP system in which the signals are digitized and filtered. Finally, the signals were integrated for taking the force profile. The processed signals of the output of the sensor were visualized in a personal computer, and the shape and force distribution of the contact object were obtained. The reasonable performance for the detection of the contact state was verified through the sensing examples.

Development and Application of Electrode for a New Secondary Aqueous Cell (새로운 수용성 2차 전지용 전극의 개발과 응용)

  • Hwang, Kum-Sho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.2
    • /
    • pp.165-170
    • /
    • 2005
  • Al-Zn alloy/$MnO_2$, seawater cell was considered as a primary aqueous cell with an average voltage range from 1.0 to 1.1V, and the electrolyte of seawater was uptaken into the cell. Eventually, the capacity of its usage will be used for long-term. However, the more use of this cell, the higher corrosion phenomenon of the electrode occurred. Due to its corrosion phenomenon, one main default has been observed with gradual decrease during a discharge process. In this research, a common-used active material for anode was $LiNiO_2$. An active material for cathode, $Zn_{X}FeS_2$ was synthesized in high temperature by uptaken a small amount of 1.3 wt% of ZnS into $FeS_2$, one of the transition-metal dichalcogenides in high temperature. Consequently, based on their usages shown above, this secondary aqueous lithium cell could be more developed. This cell was shown as remarkable charge/discharge performance during the charge/discharge processes. This cathode with active material was given a considerable efficiency of inserting $Li^+$ ions. Moreever, in accordance with the characteristic of the crystal structure for $Zn_{x}FeS_2$, a small amount of ZnS was added which made it possible to reduce prominently velocity of corrosion during the charge/discharge cycle. By applying those merits, Al-Zn alloy/$MnO_2$ seawater cell will be used as a fundamental data in order to transform into a secondary aqueous cell.

The Effect that the Application of Time-Based Electrolysis Has on Acute Ischemia

  • Lee, Jung Sook;Song, Young Wha;Kim, Sung Won
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.6 no.2
    • /
    • pp.846-851
    • /
    • 2015
  • This neurological damage accelerates the infection reaction of cells and apoptosis at the time of reperfusion after ischemia occurs. BCL-2/BCL-2 allogeneic begeminum has a function of suppressing the apoptosis of cells, and thus it is inferred that the susceptibility of cells to apoptosis is determined by the amount of allogeneic begeminum present which is determined based on the amount of BAX. Ischemia was induced in SD mice by occluding the common carotid artery for 5 minutes, after which blood was re-perfused. NEES was applied to acupuncture points, at 12, 24, and 48 hours post-ischemia on the joksamri, Hapgok. Protein expression was investigated through BAX antibody immuno-reactive cells in the cerebral nerve cells and Western blotting. The results were as follows: In the present study as well, as a result of observation of the change in the number of the BAX reaction cells after the inducement of GI, there was the aspect of most of the BAX reaction cells being observed in the corpus striatum area of the GI group 24 hours after the inducement of ischemia. This revealed the same results as those of previous studies in which the change in the number of BAX reaction cells occurred in all areas while ischemia was in progress. The change in the expression of BAX protein after 24 hours showed that there was a very significant reduction in the NEES group compared to the GI group (p<.01). As a result, a greatest amount of change in the number of BAX immunoreactive cells related to apoptosis 24 hours after ischemia appeared in the NEES group. This study that ischemia increases the expression of BAX that induces apoptosis. Thus, it is determined that ischemia is the main cause of the apoptosis of neurons, and this study reveals that low frequency needle electrode electrical stimulation has the effect of blocking the apoptosis of neurons by reducing protein related to the apoptosis of cells that has increased after ischemia has occurred.

The Effects of NEES on PARP Expression and Cell Death in Rat Cerebral Cortex After Ischemic Injury

  • Kim, Sung-Won;Lee, Jung-Sook;Um, Ki-Mai;Kim, Ji-Sung;Lee, Suk-Hee;Choi, Yoo-Rim;Kim, Nyeon-Jun;Kim, Bo-Kyoung;Cho, Mi-Suk;Park, Joo-Hyun;Kim, Soon-Hee
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.1 no.2
    • /
    • pp.107-112
    • /
    • 2010
  • The majority of strokes are caused by ischemia and result in brain tissue damage, leading to problems of the central nervous system including hemiparesis, dysfunction of language and consciousness, and dysfunction of perception. The purpose of this study was to investigate the effects of Poly(ADP-ribose) polymerase(PARP) on necrosis in neuronal cells that have undergone needle electrode electrical stimulation(NEES) prior to induction of ischemia. Ischemia was induced in male SD rats(body weight 300g) by occlusion of the common carotid artery for 5 min, after which the blood was reperfused. After induction of brain ischemia, NEES was applied to Zusanli(ST 36), at 12, 24 and 48 hours. Protein expression was investigated using immuno-reactive cells, which react to PARP antibodies in cerebral nerve cells, and Western blotting. The results were as follows: In the cerebral cortex, the number of PARP reactive cells after 24 hours significantly decreased(p<.05) in the NEES group compared to the GI group. PARP expression after 24 hours significantly decreased(p<.05) in the NEES group compared to the GI group. As a result, NEES showed the greatest effect on necrosis-related PARP immuno-reactive cells 24 hours after ischemia, indicating necrosis inhibition, blocking of neural cell death, and protection of neural cells. Based on the results of this study, NEES can be an effective method of treating dysfunction and improving function of neuronal cells in brain damage caused by ischemia.

  • PDF

Electro-optic characteristics of novel biased vertical alignment device using the polymerized reactive mesogen (광경화성 단분자를 이용한 새로운 수직배향 액정 디바이스의 전기 광학적 특성연구)

  • Kim, Dae-Hyun;Kim, Sung-Min;Cho, In-Young;Kim, Woo-Il;Kwon, Dong-Won;Son, Jong-Ho;Ryu, Jae-Jin;Kim, Kyeong-Hyeon;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.269-270
    • /
    • 2009
  • The biased vertical alignment (BVA) liquid crystal (LC) mode shows a has a distinct advantage of lower manufacture cost due to the elimination of a lithographic process step to form either ITO-patterning or protrusions on the color-filter substrates. However, those devices have complex voltage conditions which is the respective induce voltage on common electrode, pixel electrode and bias electrode when positive and negative frame. In order to overcome the complex voltage condition, the pretilt angles is controlled by photo polymerization of the UV-curable reactive mesogen (RM). According to our studies, voltages to the cell are critical to achieve an optimized surface-modified quality BVA (Q-BVA) mode which provides the well defined reorientation of the LCs with respect to an electric field.

  • PDF