• 제목/요약/키워드: Commissioning

검색결과 270건 처리시간 0.029초

COMMISSIONING RESULT OF THE KSTAR HELIUM REFRIGERATION SYSTEM

  • Park, Dong-Seong;Chang, Hyun-Sik;Joo, Jae-Joon;Moon, Kyung-Mo;Cho, Kwang-Woon;Kim, Yang-Soo;Bak, Joo-Shik;Cho, Myeon-Chul;Kwon, Il-Keun;Andrieu, Frederic;Beauvisage, Jerome;Desambrois, Stephane;Fauve, Eric
    • Nuclear Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.467-476
    • /
    • 2008
  • To keep the superconducting (SC) magnet coils of KSTAR at proper operating conditions, not only the coils but also other cold components, such as thermal shields (TS), magnet structures, SC bus-lines (BL), and current leads (CL) must be maintained at their respective cryogenic temperatures. A helium refrigeration system (RRS) with an exergetic equivalent cooling power of 9 kW at 4.5 K without liquid nitrogen ($LN_2$) pre-cooling has been manufactured and installed. The main components of the KST AR helium refrigeration system (HRS) can be classified into the warm compression system (WCS) and the cryogenic devices according to the operating temperature levels. The process helium is compressed from 1 bar to 22 bar passing through the WCS and is supplied to cryogenic devices. The main components of cryogenic devices are consist of cold box (C/B) and distribution box (D/B). The C/B cool-down and make the various cryogenic helium for the KSTAR Tokamak and the various cryogenic helium is distributed by the D/B as per the KSTAR requirement. In this proceeding, we will present the commissioning results of the KSTAR HRS. Circuits which can simulate the thermal loads and pressure drops corresponding to the cooling channels of each cold component of KSTAR have been integrated into the helium distribution system of the HRS. Using those circuits, the performance and the capability of the HRS, to fulfill the mission of establishing the appropriate operating condition for the KSTAR SC magnet coils, have been successfully demonstrated.

Superconducting Magnet Power Supply System for the KSTAR 2nd Plasma Experiment and Operation

  • Choi, Jae-Hoon;Lee, Dong-Keun;Kim, Chang-Hwan;Jin, Jong-Kook;Han, Sang-Hee;Kong, Jong-Dae;Hong, Seong-Lok;Kim, Yang-Su;Kwon, Myeun;Ahn, Hyun-Sik;Jang, Gye-Yong;Yun, Min-Seong;Seong, Dae-Kyung;Shin, Hyun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.326-330
    • /
    • 2013
  • The Korea Superconducting Tokamak Advanced Research (KSTAR) device is an advanced superconducting tokamak to establish scientific and technological bases for attractive fusion reactor. This device requires 3.5 Tesla of toroidal field (TF) for plasma confinement, and requires a strong poloidal flux swing to generate an inductive voltage to produce and sustain the tokamak plasma. KSTAR was originally designed to have 16 serially connected TF magnets for which the nominal current rating is 35.2 kA. KSTAR also has 7 pairs of poloidal field (PF) coils that are driven to 1 MA/sec for generation of the tokamak plasma according to the operation scenarios. The KSTAR Magnet Power Supply (MPS) was dedicated to the superconducting (SC) coil commissioning and $2^{nd}$ plasma experiment as a part of the system commissioning. This paper will describe key features of KSTAR MPS for the $2^{nd}$ plasma experiment, and will also report the engineering and commissioning results of the magnet power supplies.

Analysis of Dose Distribution According to the Initial Electron Beam of the Linear Accelerator: A Monte Carlo Study

  • Park, Hyojun;Choi, Hyun Joon;Kim, Jung-In;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.10-19
    • /
    • 2018
  • Background: Monte Carlo (MC) simulation is the most accurate for calculating radiation dose distribution and determining patient dose. In MC simulations of the therapeutic accelerator, the characteristics of the initial electron must be precisely determined in order to achieve accurate simulations. However, It has been computation-, labor-, and time-intensive to predict the beam characteristics through predominantly empirical approach. The aim of this study was to analyze the relationships between electron beam parameters and dose distribution, with the goal of simplifying the MC commissioning process. Materials and Methods: The Varian Clinac 2300 IX machine was modeled with the Geant4 MC-toolkit. The percent depth dose (PDD) and lateral beam profiles were assessed according to initial electron beam parameters of mean energy, radial intensity distribution, and energy distribution. Results and Discussion: The PDD values increased on average by 4.36% when the mean energy increased from 5.6 MeV to 6.4 MeV. The PDD was also increased by 2.77% when the energy spread increased from 0 MeV to 1.019 MeV. In the lateral dose profile, increasing the beam radial width from 0 mm to 4 mm at the full width at half maximum resulted in a dose decrease of 8.42% on the average. The profile also decreased by 4.81% when the mean energy was increased from 5.6 MeV to 6.4 MeV. Of all tested parameters, electron mean energy had the greatest influence on dose distribution. The PDD and profile were calculated using parameters optimized and compared with the golden beam data. The maximum dose difference was assessed as less than 2%. Conclusion: The relationship between the initial electron and treatment beam quality investigated in this study can be used in Monte Carlo commissioning of medical linear accelerator model.

동일 기종 선형가속기간 8 MV 광자선에 대한 빔 매칭 정확도 평가 (Evaluation of Beam-Matching Accuracy for 8 MV Photon Beam between the Same Model Linear Accelerator)

  • 김연래;정진범;강성희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권2호
    • /
    • pp.105-114
    • /
    • 2020
  • This study aimed to assess of beam-matching accuracy for an 8 MV beam between the same model linear accelerators(Linac) commissioned over two years. Two models were got the customer acceptance procedure(CAP) criteria. For commissioning data for beam-matched linacs, the percentage depth doses(PDDs), beam profiles, output factors, multi-leaf collimator(MLC) leaf transmission factors, and the dosimetric leaf gap(DLG) were compared. In addition, the accuracy of beam matching was verified at phantom and patient levels. At phantom level, the point doses specified in TG-53 and TG-119 were compared to evaluate the accuracy of beam modelling. At patient level, the dose volume histogram(DVH) parameters and the delivery accuracy are evaluated on volumetric modulated arc therapy(VMAT) plan for 40 patients that included 20 lung and 20 brain cases. Ionization depth curve and dose profiles obtained in CAP showed a good level for beam matching between both Linacs. The variations in commissioning beam data, such as PDDs, beam profiles, output factors, TF, and DLG were all less than 1%. For the treatment plans of brain tumor and lung cancer, the average and maximum differences in evaluated DVH parameters for the planning target volume(PTV) and the organs at risk(OARs) were within 0.30% and 1.30%. Furthermore, all gamma passing rates for both beam-matched Linacs were higher than 98% for the 2%/2 mm criteria and 99% for the 2%/3 mm criteria. The overall variations in the beam data, as well as tests at phantom and patient levels remains all within the tolerance (1% difference) of clinical acceptability between beam-matched Linacs. Thus, we found an excellent dosimetric agreement to 8 MV beam characteristics for the same model Linacs.

프로젝트 및 발주자 특성을 고려한 CM업무 위탁모델 (Commissioning Model for CM Services Considering Project and owner Properties)

  • 강현구;유정호;김창덕
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2007년도 정기학술발표대회 논문집
    • /
    • pp.632-636
    • /
    • 2007
  • 최근 건설프로젝트는 점차 대형화, 복잡화 되어가고 있으며 그에 따라 관리하여야 할 항목 또한 늘어났으며 발주자 조직 역시 축소되었다. 이에 따라 국내 건설산업에도 다양한 사업관리방식이 도입되었다. 그러나 이와 같은 건설사업관리의 도입은 시행착오로 인한 혼라, 제도의 불합리성으로 인한 관리주체의 역할중복으로 인하여 비용증가 등의 문제를 야기시키고 있다. 그리고 건설프로젝트는 그 특성상 매 프로젝트마다 각자 다른 특성을 가지고 있으며 프로젝트의 발주자 조직 역시 다양한 특성을 지니고 있다. 하지만 건설사업관리에 있어서 이러한 특성을 반영하지 못하고 있으며 획일적인 사업관리 방식만이 적용되어지고 있다. 이러한 문제의 해결을 위하여 본 연구에서는 프로젝트의 특성과 발주자의 특성의 분석을 통하여 해당 프로젝트에 특화될 수 있는 CM업무 위탁모델을 제안하고자 한다. 이를 위하여 프로젝트, 발주자 능력, 발주자 요구사항을 파악, 분석하여 중점관리대상의 선정, CM의 서비스항목, 발주자의 역할정의를 하고자 한다.

  • PDF

세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용 (Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119)

  • 안우상;조병철
    • 한국의학물리학회지:의학물리
    • /
    • 제22권2호
    • /
    • pp.99-105
    • /
    • 2011
  • 본 연구에서는 미국의학물리학회(AAPM)에서 제안된 세기조절방사선치료(IMRT)의 commissioning 및 정도관리를 위해 제안된 일련의 시험을 통해 본원의 세기조절방사선치료의 정확도를 평가하고 정도관리 절차를 수립하고자 하였다. TG119에 제시된 5가지 세기조절방사선치료의 표적체적: multi-target, 두경부, 전립선, 및 두 가지의 C-shape (easy&hard)을 대상으로 CT 스캔된 팬텀을 이용하여 치료계획시스템에서 IMRT 치료계획을 수행하였다. 얻어진 치료계획을 dynamic sliding window 전달방식으로 팬텀에 조사하였다. 절대 선량은 표적 및 위험장기 부위에 이온 전리함(CC13, IBA)을 이용하여 측정하고, 2차원 상대 선량분포는 EBT2 필름을 사용하여 측정하였다. 측정된 값들은 해당하는 치료계획시스템 계산값과 비교하여 오차의 평균 및 표준편차를 구하였다. 이를 바탕으로 TG119에 제시된 신뢰구간을 계산하여 제시된 값과 비교하였다. 이온 전리함을 이용한 측정 결과에서 표적 및 위험장기에 대한 계산값과 측정값 사이의 평균오차는 각각 $1.2{\pm}1.1%$$1.2{\pm}0.7%$이었고, 95% 신뢰구간은 각각 3.4%와 2.6%으로 TG119에서 제시하고 있는 4.5%와 4.7% 이내에 있었다. 필름을 이용한 측정 결과에서는 허용기준 3%/3 mm를 통과하는 감마인덱스는 평균$ 97.7{\pm}0.8%$로 95% 신뢰구간은 3.9%로 TG119에서 제시하고 있는 7.0% 이내에 있었다. 따라서 TG119에서 제시된 일련의 표준화된 시험을 통해 본원의 세기조절방사선치료의 commissioning 및 정도관리를 평가할 수 있었다. 이온 전리함을 이용한 절대 선량에 대한 action level은 표적과 위험장기에서 각각 ${\pm}4%$${\pm}3%$로, EBT2 필름을 이용한 2차원 상대선량분포는 허용기준 3%/3 mm 기준으로 감마인덱스 1이하를 통과하는 비율이 96%로 정할 수 있었다. 이를 통해 TG119에서 제시된 일련의 표준화된 시험을 통해 각 기관의 IMRT 정확도 평가에 대한 객관적인 지표로 이용될 수 있을 것으로 기대된다.

주위 온도변화가 다층구조 해저 파이프라인 내부 압력변화에 미치는 영향 (Effects of Ambient Temperature Change on the Internal Pressure Change of Multi-Layered Subsea Pipeline)

  • 양승호
    • 해양환경안전학회지
    • /
    • 제25권6호
    • /
    • pp.772-779
    • /
    • 2019
  • 해저 파이프라인은 자원개발을 포함한 에너지산업 및 철강산업과 연계한 고부가가치 산업으로서 상당한 관심을 받아왔다. 해저 파이프라인의 설계와 설치 프로젝트 수행을 위해서는 다양한 핵심요소기술들이 필요하다. 특히, 해저 파이프라인의 안전한 운영을 위해서는 예비커미셔닝을 통한 철저한 사전검증과정이 필수 불가결한 부분이다. 해저 파이프라인 예비커미셔닝 과정 중 하이드로테스팅 공정은 파이프라인 주위 온도변화에 크게 영향을 받는 것으로 알려져 있으나 이에 관한 이론적, 수치해석적 접근방법을 활용한 연구는 미미한 편이다. 본 연구에서는 해저 파이프라인의 예비커미셔닝 과정 중 하이드로테스팅 공정에 대해 과도열전달 해석법을 활용하여 내부 온도변화량 산정 및 이를 활용한 파이프라인 내부 압력변동량 예측법을 제시하였고 예측된 결과를 현장 실계측 데이터와 비교·검토하여 그 유효성을 입증하였다. 제안된 해석절차는 해저 파이프라인 설치 프로젝트 수행 사전단계에서부터 파이프라인 열전달 시뮬레이션을 통해 압력변동량 예측을 가능하게 함으로써 해저 파이프라인 설치 프로젝트의 생산성 향상에 크게 기여할 것으로 사료된다.

A Commissioning of 3D RTP System for Photon Beams

  • Kang, Wee-Saing
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.119-120
    • /
    • 2002
  • The aim is to urge the need of elaborate commissioning of 3D RTP system from the firsthand experience. A 3D RTP system requires so much data such as beam data and patient data. Most data of radiation beam are directly transferred from a 3D dose scanning system, and some other data are input by editing. In the process inputting parameters and/or data, no error should occur. For RTP system using algorithm-bas ed-on beam-modeling, careless beam-data processing could also cause the treatment error. Beam data of 3 different qualities of photon from two linear accelerators, patient data and calculated results were commissioned. For PDD, the doses by Clarkson, convolution, superposition and fast superposition methods at 10 cm for 10${\times}$10 cm field, 100 cm SSD were compared with the measured. An error in the SCD for one quality was input by the service engineer. Whole SCD defined by a physicist is SAD plus d$\sub$max/, the value was just SAD. That resulted in increase of MU by 100${\times}$((1_d$\sub$max//SAD)$^2$-1)%. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth in uniform medium of relative electron density (RED) 1, PDDs for 4 algorithms of dose calculation, Clarkson, convolution, superposition and fast-superposition, were compared with the measured. The calculated PDD were similar to the measured. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth with 5 cm thick inhomogeneity of RED 0.2 under 2 cm thick RED 1 medium, PDDs for 4 algorithms were compared. PDDs ranged from 72.2% to 77.0% for 4 MV X-ray and from 90.9% to 95.6% for 6 MV X-ray. PDDs were of maximum for convolution and of minimum for superposition. For 15${\times}$15 cm symmetric wedged field, wedge factor was not constant for calculation mode, even though same geometry. The reason is that their wedge factor is considering beam hardness and ray path. Their definition requires their users to change the concept of wedge factor. RTP user should elaborately review beam data and calculation algorithm in commissioning.

  • PDF

CM 전문회사 단장 활용실태 및 개선방안 (Analyzing the Engagement of Professional Construction Managers in Construction Management firm and Its Improvement Measures)

  • 손창백;허영기;이동은
    • 한국건설관리학회논문집
    • /
    • 제14권2호
    • /
    • pp.87-95
    • /
    • 2013
  • 국내 CM시장이 활성화됨에 따라 경쟁이 심화되어 실제 프로젝트 관리를 담당하는 CM단장의 능력은 CM사업 수주를 위한 중요한 요소가 되었다. 이로 인해 각 CM전문회사는 유능한 CM단장의 확보를 위해 현재 담당 프로젝트가 없더라도 후속 프로젝트의 수주를 위해 CM단장을 일정수 대기상태로 확보하고 있으나, 효율적인 활용방안에 대해서는 체계적인 방법이 마련되지 못한 실정이다. 이에 본 연구는 현재 CM전문회사가 보유하고 있는 대기상태 CM단장들의 활용실태 및 문제점을 분석하고, CM단장의 효율적인 활용을 위한 개선방안을 모색하기 위한 실무적 기초자료를 제시하고자 하였다. 본 연구결과, CM전문회사의 현재 대기상태 CM단장 인력수는 적정 비율 및 인력수에 비해 약 2배 정도 많은 것으로 나타났고, CM단장의 선정기준으로 프로젝트의 수주를 위해 프레젠테이션 능력을 가장 중요한 요소로 고려하고 있었다. 그리고 대기상태 CM단장의 보유 및 활용상 문제점은 크게 고용비용 증가와 현장 및 본사 업무지원능력 부족 및 제한적 활용으로 요약되었고, 대기상태 CM단장의 효율적인 활용을 위한 현장 및 본사 기술지원과 수주능력 강화 및 제도개선 등에 관한 개선방안을 제안하였다.

2DF ON THE AAT - PROJECT UPDATE AND FIRST SCIENTIFIC RESULTS

  • CANNON RUSSELL;TAYLOR KEITH
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.367-370
    • /
    • 1996
  • Construction of the 'Two-degree Field' (2dF) instrument on the Anglo-Australian Telescope (AAT) is now virtually complete and commissioning is well underway. The key components are described. Several recent milestones are reported, including the first scientific results. Future prospects and plans are discussed.

  • PDF