• Title/Summary/Keyword: Comminuted

Search Result 167, Processing Time 0.022 seconds

Intraoral Approach and K-Wire Fixation of Zygomatic Tripod Fractures (강선 고정술을 이용한 관골골절의 치료)

  • Choi, See-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.85-92
    • /
    • 1988
  • To avoid external facial scar which resulted from ordinary infraorbital and lateral eyebrow incision in surgical treatment of zygomatic tripod fractures, the author used intraoral incision and K-wire fixation method in 37 selected patients. This method contraindicated for the patient with multiple comminuted zygomatic fracture, patient combined with hard palatal fracture, and patient combined with herniated orbital floor fracture. The advantages of this method are simple, no external facial scar, and operate under direct visual field. The postoperative results were satisfactory. Balanced facial symmetry and good cosmetic results were obtained.

  • PDF

Traumatic Atlantoaxial Rotatory Fixation with Accompanying Odontoid and C2 Articular Facet Fracture

  • Oh, Jong-Yang;Chough, Chung-Kee;Cho, Chul-Bum;Park, Hae-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.5
    • /
    • pp.452-454
    • /
    • 2010
  • Traumatic atlantoaxial rotatory fixation (AARF) with accompanying odontoid and C2 articular facet fracture is a very rare injury, and only one such case has been reported in the medical literature. We present here a case of a traumatic AARF associated with an odontoid and comminuted C2 articular facet fracture, and this was treated with skull traction and halo-vest immobilization for 3 months. After removal of the halo-vest immobilization, his neck pain was improved and his neck motion was preserved without any neurologic deficits although mild torticolis was still observed in closer inspection.

Surgical Treatment of Ipsilateral Multi-Level Femoral Fracture Treated Using Antegrade Intramedullary Nail

  • Kim, Beom-Soo;Cho, Jae-Woo;Yeo, Do-Hyun;Oh, Jong-Keon
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2018
  • Ipsilateral fractures of proximal femur with shaft and condylar region are very rare. Current concept of management is based on fixation of each fracture as independent entity using separate fixation modalities for proximal and distal parts of femur. However, we considered that antegrade femoral nailing with cephalomedullary screw fixation is a good option for ipsilateral multi-level femoral fractures. Here, we present an experience of satisfactory treatment for ipsilateral femoral neck fracture, subtrochanteric fracture, comminuted shaft fracture with supracondylar fracture following road traffic accident.

Attrition Milling and Reaction-Sintering of the Oxide-Metal Mixed Powders: I. Milling Behavior as the Powder Characteristics (산화물과 금속 복합 분말의 Attrition Milling 및 반응소결: I. 분말의 특성에 따른 분쇄 거동)

  • 황규홍;박정환;윤태경
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.3
    • /
    • pp.337-345
    • /
    • 1994
  • The reaction-sintered alumina and zirconia-alumina ceramics having low firing shrinkage were prepared from the Al/Al2O3 or Al/ZrO2(Ca-PSZ) powder mixtures via the attrition milling. And in this milling process the effect of the characteristics of used powders was investigated. Attrition milling was much more effective in reducing the particle size of ceramic/metal mixed powders than ball milling. Powder mixtures of flake-type Al with coarse alumina was much more effectively comminuted by the attrition milling than the mixtures of globular-type Al with coarse alumina powders. And coarse alumina than fine alumina was much more beneficial in cutting and reducing the ductile Al particles. In the contrary to Al/Al2O3 powder mixtures, Al/ZrO2 powder mixtures was not effectively comminutd. But whether using the alumina ball media or attrition milled with Al2O3 powder rather than Al, the milling efficiency was much more increased.

  • PDF

Treatment of Talonavicular Subluxation Accompanied by Calcaneal Malunion (A Case Report) (종골 부정 유합에 동반된 거주상 관절 아탈구의 치료 (1예 보고))

  • Cha, Seong-Mu;Chang, Bo Hoon;Suh, Jin-Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.4
    • /
    • pp.270-275
    • /
    • 2012
  • There may be complications after comminuted or intraarticular calcaneal fracture regardless of the initial treatment. Transcalcaneal talonavicular dislocation is rarely reported severe form of calcaneal fracture. We experienced a neglected transcalcaneal talonavicular subluxation case, who had been treated for intraarticular calcaneal fracture conservatively. Subtalar distraction bone block fusion was done for calcaneal malunion with talonavicular subluxation. Inspite of successful subtalar fusion, pain was persisted because of talonavicular re-subluxation with arthritis and calcaneocuboid arthritis. So, second operation, the talonavicular and calcaneocuboid fusion, was done. After union achieved, the patient's foot pain was improved. Calcaneal malunion combined with talonavicular subluxation and unstable transverse tarsal joint, such as this case, initial triple arthrodesis could be considered.

Study on Development of High Performance Microwave Absorber Using Natural Lacquer Binder (옻칠을 소재로한 고성능 전파흡수체의 개발에 관한 연구)

  • 김동일;최동한;구동우;김도연;옥승민;양은정;김보영
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.03a
    • /
    • pp.53-57
    • /
    • 2002
  • In this paper, we explain new EM(electromagnetic) wave absorber that mixed NC (Natural Ceramics) and Ferrite with NL(Natural Lacquer). At first, a mixed NC and Ferrite(NC : F = (0.1~30)wt% : (99.9~70)wt%) bum at 95$0^{\circ}C$~125$0^{\circ}C$. And then, it is comminuted and injected into NL((NC+F) . NL = (30~80)wt% (70~20)wt%), finally we made Ferrite-NL EM wave absorber. Generally, conventional labor Ferrite covers only 500 MHz to 10 GHz under tolerance limits of 2 to 6 dB in absorption, and Ferrite-NL is over 8 ~ 14 dB. However, NCFerrite-NL huts superior absorption ability. It is over 16 to 19 dB through 500 MHz to 10 GHz.

  • PDF

Application of Plate and Circumferential Wiring with Resin to Bilateral Mandibular Fractures in a Calf: Case Report

  • Yu, Yong;Kim, Namsoo;Heo, Suyoung
    • Journal of Veterinary Clinics
    • /
    • v.37 no.6
    • /
    • pp.363-366
    • /
    • 2020
  • A 2-month-old, 50 kg male Korean native calf was referred with bilateral mandibular fractures. The bilateral mandible was hanging loose, with inability to use the jaw, indicated by excessive salivation. Radiography revealed a long oblique fracture in the right mandible, and a short oblique fracture in the left mandible. Computerized Tomography, a different form of radiography, revealed the fracture in the left mandible to be a comminuted fracture. In order to stabilize the bilateral mandible fractures, a combination of bone plate and wiring was applied; in addition, resin was applied to enhance stabilization of the mandible. Six weeks after surgery, the calf was able to masticate and ruminate well. In this case, application of the plate and wiring with resin to bilateral mandibular fractures presented a successful functional recovery. Accordingly, the combination of bone plate and wiring with resin can be an effective technique for treating mandibular fractures.

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

Treatment of Distal Clavicular Fracture by Reconstruction Plate and Wire Fixation (쇄골 원위부 골절에 대한 재건 금속판과 강선 고정술을 이용한 치료)

  • Suh, Mu-Sam;Kim, Sang-Hyo;Park, Hyeong-Taek
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.58-62
    • /
    • 2006
  • Purpose: To evaluate the result of operative treatment with plate and wire fixation for fractures of the distal clavicle. Materials and Methods: We assessed 9 cases of fractures of the distal clavicle that were treated by plate and wire fixation from March 2001 to July 2003 and followed up over 1year. We used the reconstruction plate as a buttress and performed cerclage wiring to fix comminuted fracture site. The functional result of shoulder was evaluated by the scoring system of Rowe. Results: The average periods of bony union was 9 weeks in all cases. According to Rowe scoring system, the functional result was exellent in 7 cases and good in 2 cases. There was no LOM of shoulder and traumatic arthritis in AC joint. But there was skin irritation in 1 case. Conclusion : The operative method by reconstruction plate and wire fixation for distal clavicular fracture was useful when there were comminuted fracture. This method seems to be simple and satisfactory in terms of improvement of range of motion of shoulder, restoration of function and rare complication.

  • PDF

Hemiarthroplasty for the Comminuted Fracture of the Proximal Humerus (상완골 근위부 분쇄 골절에서의 상완골 두 치환술)

  • Seo Joong-Bae;Won Choong-Hee;Kim Yong-Min;Choi Eui-Seong;Lee Ho-Seung;Hong Yoon-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.2
    • /
    • pp.61-67
    • /
    • 2000
  • Purpose: Most proximal humeral fractures are minimally displaced and can be treated satisfactorily with a conservative method. But in many comminuted fractures, hemiarthroplasty is usually done as a primary treatment. The authors evaluated how much functional improvement was achieved after hemiarthroplasty and which factors influence on the final functional results. Materials and Methods: Eleven hemiarthroplasties were performed for three- and four-part fractures(including fracture-dislocation) between April 1992 and June 1999. There were eight women and three men, and the mean age was 65 years. According to Neer classification, six was three-part fracture and five was four-part fracture. Six patients were injured on their right shoulder and five on the left shoulder. Among the five four-part fractures, three had axillary nerve injury and among the six three-part fractures, only one patient had axillary nerve injury. The average follow-up period was 2.4 years(1 year-7 years) after operation. The functional results were evaluated with the UCLA scoring system(Modification for hemiarthroplasty). In addition to the overall results, we compared the results according to the classification of the fracture, the cause of injury, and whether the axillary nerve was injured. Results: At the last follow-up, average total UCLA score was 18.2. The mean score for pain was 7.0, mean muscle power and motion score was 5.5 and 5.7 respectively. The pain relief was more satisfactory than any other functional results. The average score for three-part fractures was 22, and the average for four-part fractures was 13.6. The average score for the patients fractured by vehicle accidents was 15.3, and 19.3 for the patients fractured by slip-down injury. In patients without axillary nerve injury, the average score was 20, and with axillary nerve injury, the score was 15. Conclusion: Shoulder hemiarthroplasty, for the treatment of proximal humeral fractures, cannot restore the shoulder function to normal, but can achieve the functional result to some degree, especially for the activity of daily living. And as for pain, we think that it is relatively effective measure. And we think that the severer the comminution, the more the chance of axillary nerve injury, and the poorer the functional results. In conclusion, the severity of initial injury seems to be the major prognostic factor.

  • PDF