• 제목/요약/키워드: Commercial power changing

검색결과 57건 처리시간 0.021초

CFD에 의한 입형 다단 원심펌프 유동특성에 관한 연구 (A Study on Flow Characteristics of Vertical Multi-stage Centrifugal Pump by CFD)

  • 모장오;남구만;김유택;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.402-407
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pimp including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26\;m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is to confirm how much the effect of blade inlet angle of guide vane has an influence on the performance of vertical multi-stage centrifugal pimp. these results performed by $20^{\circ},\;30^{\circ}$ inlet angle of guide vane are compared with grundfos performance data. The vertical multi-stage pump consist of the impeller, guide vane, and cylinder. The characteristics such as total pressure coefficient total heat shaft horse power, power efficiency, discharge coefficient are represented according to flow rate changing.

  • PDF

입형 다단 원심펌프 유동특성에 관한 수치해석 (A Numerical Analysis on Flow Characteristics of Vertical Multi-stage Centrifugal Pump)

  • 모장오;강신정;송근택;김성동;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.589-592
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pump including impeller of centrifugal pump with 6 blades and guide vain with 11 blades. The numerical analysis of vertical multi-stage centrifugal pump is performed by changing flow rate from $8\;to\;26\;m^{3}/h$ at the constant 3500rpm. The characteristics such as total pressure coefficient, total head, water horse power, power efficiency are represented according to flow rate changing. In the future, we will need to perform flow calculation of vertical multi-stage centrifugal pump by considering meridional shape of impeller.

  • PDF

유압식 동력 조향기어 박스에서 설계변수의 특성검토 (Characteristic Investigation of Design Parameters on the Hydraulic Power Steering Gear Box)

  • 장주섭;윤영환
    • 한국자동차공학회논문집
    • /
    • 제16권4호
    • /
    • pp.135-142
    • /
    • 2008
  • Hydraulic power steering system has been adopted in seniority passenger and commercial vehicle system for an easy maneuverability and a smoother ride. In this study, hydraulic power steering system analysis model which includes hydraulics and mechanical sub-systems was developed using commercial software, AMESim in order to predict characteristics for various steering components. Each component which constructs system was modeled and verified by experimentally obtained characteristics curves of each components. The parameter sensitivity analysis such as valve opening area, torsional stiffness of torsion bar for system design are carried out by the analysis and experimental method. The predicted results by the development model were a good agreement with experimentally obtained results. The sensitivity investigation results rotary torque when changing an input shaft edge width, was most sensitive, to change in angle and slot width and supply flow of input shaft edge is not a lot sensitively.

상용 CFD코드를 이용한 입형 다단 원심펌프 성능해석 (Performance Analysis of the Vertical Multi-stage Centrifugal Pump using Commercial CFD Code)

  • 모장오;강신정;송근택;남청도;이영호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 추계 학술대회논문집
    • /
    • pp.150-155
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pump including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is not only to confirm how much the effect of three kinds of blade inlet breadth (11mm, 11.5mm, 12mm) of impeller has influence on the performance of vertical multi-stage pump but also to make clear the cause about performance difference at the exit side of impeller and guide vane. The vertical multi-stage pump consisit of the impeller, guide, vane and cylinder. The grid of numerical analysis used to the vertical multi-stage pump is 18,000, 45,000, and 100000 cells in case of the impeller, guide vane, cylinder and total grid is 730,000 cells. The characteristics such as total pressure coefficient, total head, shaft horse power, power efficiency at the exit side of impeller and guide vane, discharge coefficient are represented according to flow rage changing.

  • PDF

전력수요 탄력성에 따른 각 용도별 부하의 전력수요 영향 (The Effects of the Electric Power Demand for Each Loads Based the Electric Power Demand Elasticity)

  • 김문영;백영식;송경빈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권12호
    • /
    • pp.568-574
    • /
    • 2001
  • The variations of real time electric power price in competitive electricity markets have influence on electric power demands of the consumers. The effects of the consumers for electric power price can be expressed the price elasticity coefficient of the power demand as a measurement. Residential, commercial, and industrial consumers with different characteristics cause the different price elasticity of the power demand due to changing the pattern of consumption. It is necessary that the effects of electric power demands as a function of elasticity coefficient for each loads should be analyzed in Korea which is processing deregulated electric market. Therefore, this paper calculate the elasticity coefficient of each loads and analysis the effects of electric power demands as a function of elasticity coefficient of inflexible and flexible consumers in competitive electricity market.

  • PDF

Experimental performance characteristics of 1 kW commercial PEM fuel cell

  • Shubhaditya Kumar;Pranshu Shrivastava;Anil Kumar
    • Advances in Energy Research
    • /
    • 제8권4호
    • /
    • pp.203-211
    • /
    • 2022
  • The aim of this paper is to analyze the performance of commercial fuel cell (rated capacity 1000W) with the help of resistive load and output power variation with change in H2 flow rate and calculate the maximum power point (MPP) of the proton exchange membrane (PEM) while changing AC and DC load respectively. The factors influencing the output power of a fuel cell are hydrogen flow rate, cell temperature, and membrane water content. The results show that when the H2 flow rate is changed from 11, 13, and 15 Lpm, MPP is increased from lower to higher flow rate. The power of the fuel cell is increased at the rate of 29% by increasing the flow rate from 11 to 15 lpm. This study will allow small-scale industries and residential buildings (in remote or inaccessible areas) to characterize the performance of PEMFC. Furthermore, fuel cell helps in reducing emission in the environment compared to fossil fuels. Also, fuel cells are ecofriendly as well as cost effective and can be the best alternative way to convert energy.

석탄가스화 복합화력 발전용 가스터빈 성능해석 (Performance Analysis of a Gas Turbine for Integrated Gasification Combined Cycle)

  • 이종준;차규상;손정락;김동섭
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.771-774
    • /
    • 2007
  • Integrated Gasification Combined Cycle (IGCC) power plant converts coal to syngas, which is mainly composed with hydrogen and carbon monoxide, by the gasification process and produces electric power by the gas and steam turbine combined cycle power plant. The purpose of this study is to investigate the influence of the syngas to the performance of a gas turbine in a combined cycle power plant. For this purpose, a commercial gas turbine is selected and its performance characteristics are analyzed with syngas. It is found that different heating values of those fuels and chemical compositions in their combustion gases are the causes in the different performance characteristics. Also, Changing of turbine inlet Mass flow lead to change the turbine matching point, in the event the pressure ratio is changed.

  • PDF

정상상태 전압제어를 위한 UPFC와 조상설비의 협조 (Coordination of UPFC and Reactive Power Sources for Steady-state Voltage Control)

  • 박지호;이상덕;정태영;정기석;백영식;서규석
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.921-928
    • /
    • 2011
  • This paper presents a new method of local voltage control to achieve coordinative control among UPFC(Unified Power Flow Controller) and conventional reactive compensation equipments, such as switched-shunt and ULTC(Under-Load Tap Changing) transformer. Reactive power control has various difficult aspects to control because of difficulty of system analysis. Recently, the progress of power electronics technologies has lead to commercial availability of several FACTS(Flexible AC Transmission System) devices. The UPFC(Unified Power Flow Controller) simultaneously allows the independent control of active and reactive power flows as well as control of the voltage profile. When conventional reactive power sources and UPFC are used to control system voltage, the UPFC reacts to the voltage deviation faster than the conventional reactive power sources. Keeping reactive power reserve in an UPFC during steady-state operation is always needed to provide reactive power requirements during emergencies. Therefore, coordination control among UPFC and conventional reactive power sources is needed. This paper describe the method to keep or control the voltage of power system of local area and to manege reactive power reserve using PSS/E with Python. The result of simulation shows that the proposed method can control the local bus voltage within the given voltage limit and manege reactive power reserve.

수요 탄력성에 따른 전력수요의 변화가 현물가격에 미치는 영향 (The Effects of Spot Pricing for the Change of the Electric Power Demand Based the Demand Elasticity)

  • 김문영;백영식;송경빈
    • 에너지공학
    • /
    • 제11권2호
    • /
    • pp.142-148
    • /
    • 2002
  • 경쟁적인 전력시장에서 실시간 전력가격의 변화는 전력소비자들의 전력소비에 영향을 주게된다. 서로 다른 특성을 가지는 가정용, 상업용, 산업용 부하들은 전력소비 성향의 변화에 따라 서로 다른 가지 탄력성을 가진다. 따라서, 본 논문에서는 계산된 각 용도별 부하에 대한 수요 탄력성을 적용하여 경쟁 전력시장에서 수요 탄력성에 따른 전력수요의 변화가 현물가격에 미치는 영향을 분석한다.

수요 탄력성에 따른 전력수요의 변화가 현물가격에 미치는 영향 (The effects of spot pricing for the change of the electric power demand based the demand elasticity)

  • 김문영;백영식;송경빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.524-526
    • /
    • 2001
  • The variations of real time electric price in competitive electricity markets have influence on electric power demands of the consumers. Residential, commercial, and industrial consumers, with different characteristics cause the different price elasticity of the demand due to changing the pattern of consumption. Therefore, this paper calculate the elasticity of each loads and analysis the effects of electric power demands and spot pricing as a function of elasticity in competitive electricity market.

  • PDF