• Title/Summary/Keyword: Commercial building

Search Result 788, Processing Time 0.033 seconds

Application of Seismic Isolation Technique in Residential-Commercial Building (주상복합건물에 대한 면진기술의 적용)

  • 이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.465-472
    • /
    • 2000
  • Seismic isolation technique has been applied mainly in low rise buildings and its seismic performance was satisfactory during Kobe Earthquake. However, in the case of medium and/or high-rise buildings, mid-story isolation could be more technically feasible than base isolation to reduce earthquake forces. In this paper, the seismic effectiveness of mid-story isolation in medium and/or high-rise shear building as well as low rise shear building was evaluated analytically. After verifying the effectiveness of mid-story isolation technique, this method also applied in residential-commercial building. It was found that mid-story isolation, that is isolation between upper residential area and lower commercial area, could reduce inter-story drift and floor shear forces comparing to the conventional fixed base.

  • PDF

A Study on the Improvement of Human Safety Standards Considering Fire Cases in High-rise Residential Facilities (고층 주거시설 화재사례를 고려한 인명안전기준 개선방안에 관한 연구)

  • Cho, Hwi-Je;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.106-107
    • /
    • 2021
  • The fire in Ulsan in 2020 was a 33-story residential and commercial complex with about 90 injuries and more than 10 billion won in property damage, and considering the recent increase in high-rise residential and commercial complexes, the risk of similar fires is high. As can be seen through the residential and commercial complex fire case in Ulsan, life-based fire safety standards need to be established to minimize casualties. Therefore, the purpose of this study is to draw improvements for the development of human safety standards for high-rise residential facilities in the future through comparison with the Korean Building Act, Firefighting-rellated Acts and the U.S. NFPA 101.

  • PDF

BIM-based Property Management by Linking Maintenance with Financial Data for Commercial Building Projects

  • Shin, Hyeonju;Cha, Heesung
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.418-425
    • /
    • 2022
  • For a commercial building, property managers play an important role in maximizing the benefit by reducing cost and increasing revenue in the operation and maintenance phase of the building. However, most of property managers are spending their time in monitoring facility managers who have little impact on cost reduction and maximization of operating profit. The industry practitioners have difficutlty in increasing the efficiency of thier work due to this work environment. In addition, both property managers(PMr) and facility managers(FMr) are dependent on the paper drawings and manuals, which can worsen the inefficiency and human errors are inevitable. This study aims to contribute to improvement of the current practice by developing a novel algorithm that autmatically links the facility information with 3D model, which can provide an efficient property management for commercial buildings.

  • PDF

A Study on the Complex Effects of Streetscape Components on Visual Preference (도시가로경관요소가 시각적 선호에 미치는 복합적 영향에 관한 연구)

  • 변재상;정수정;임승빈
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.2
    • /
    • pp.9-18
    • /
    • 1999
  • In this study the relative effects among trees, cars, wires and building facades on visual preference are measured with the photo-montage scenes, which were synthesized by computer graphic programs. In addition to these experiments, the interaction of each elements of streetscapes have been investigated. The results of this study can be summarized as follows ; (1) It was found that trees had a remarkable positive effect on preference for streetscapes, wires had a moderate negative effect, cars had a trivial effect and the effects of building facades were medium. (2) It was investigated that the building of residential type was most preferred among commercial, residential, and office building types. The next preferred building facade was the commercial type. (3) The interaction of each element of streetscapes also have effects on preference. Especially, it was found that the combined effects of building-wire and building-cars were more notable than other combined effects of two elements.

  • PDF

Structural Design of Mid-Story SI Tall-building with RC Frame Placed on Steel Structure

  • Isobe, Tomonobu;Aono, Hideshi
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.3
    • /
    • pp.173-178
    • /
    • 2021
  • In this paper we introduce Shinagawa HEART, located in Shinagawa district, Tokyo. It is a mixed-use building with residences on the upper floors, offices on the lower floors, and commercial uses on the first and second floors, and is intended to meet the various needs of a building on the border between residential and commercial areas. The upper floors of the building are made of reinforced concrete, while the middle and lower floors are made of steel with CFT columns. First, an overview of the structural plan of the building is presented. Next, the adoption of the middle layer seismic isolation and the switch between the lower steel structure and the upper reinforced concrete structure, which are the features of this building, are explained. Finally, the construction method adopted to achieve the design performance is explained.

A Study on the Quality Control Effectiveness in the High-rise residential-commercial Complex Building Project (초고층 주상복합건물의 품질관리 효율성에 관한 연구)

  • Kim, Suk-Hoi;Im, Chil-Soon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.4
    • /
    • pp.79-87
    • /
    • 2007
  • The object of this study is to understand of the effectiveness characteristic in the field work which is controlled by the quality in the high-rise residential-commercial complex building. From the previous study, the quality improvement factors are investigated. Through the structured questionnaire, the opinions of the field engineers(University, Design firms, Construction company) are gathered in the improvement factors of construction phase. Comparing the results of questionnaire with the conception of field engineers, this study helps in revising and improving the quality control system including tangible factors and intangible factors in the frame work of the high-rise residential-commercial complex building project.

  • PDF

Detailed Analysis on Operation Characteristics and Cooling Energy Saving Effect of Chiller Staging in an Office Building (사무소 건물에서 냉동기의 대수제어를 통한 냉동기 거동 특성 및 에너지 절감 효과 분석)

  • Seo, Byeong-Mo;Son, Jeong-Eun;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.4
    • /
    • pp.137-144
    • /
    • 2016
  • Commercial buildings account for a significant proportion of the total building energy use in Korea, and cooling energy, in turn, accounts for the largest proportion of total energy consumption in commercial buildings. Under this circumstance, chiller staging is considered to be a reasonable and practical solution for cooling energy saving. In this study, the part-load ratio and the operating characteristics of a vapor compression chiller were analysed within an office building. In addition, energy consumption among different chiller staging schemes was comparatively analysed. As a result, significant proportions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range from 0% through 50%, and thus energy consumption was significantly affected by the chiller COP at low part-load conditions, indicating that the chiller operation at the part-load is an important factor in commercial buildings. In addition, utilizing a sequential chiller staging scheme can reduce the annual cooling energy usage by more than 10.3% compared to operating a single chiller.

Development of Building Integrated PV(BIPV) module for the replacement of commercial building envelope materials (건물외피용 태양광발전 BIPV 모듈 개발 연구)

  • Yoon, Jongho;Kim, J.I;Lee, K.S.;Yu, G.J.
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.113-119
    • /
    • 2004
  • As Building Integrated Photovoltaic(BIPV) system replaces the conventional building finishing materials with PV modules, two function of electricity generation and building envelope can be expected. Therefore BIPV can be a good alternative technology for the 21 century environment-friendly buildings. The objective of this paper is to develope BIPV modules for a commercial buildings of which structure is mainly light-weight, curtain wall system. Two types of module are developed for a opaque part and a transparent part of building envelope. Current technology level and market status of Korea determines the configuration of developed BIPV modules. Architectural considerations for the integration of PV module to building envelope such as building structure, construction type, safety, regulation, maintenance etc. have been carefully reflected from the early stage of BIPV module design. Especially the survey result of current building envelope materials determines the size of unit BIPV modules and a unique cladding method for PV module installation is developed. Trial product of BIPV modules and cladding hardwares are manufactured and sample construction details for a demonstration building are proposed.

A Study on the Characteristics of Space Utilization after converting of Residential District in a New Development Area - Focused on Dunsan of Daejeon City - (신개발지 일반주거지역의 용도전환시 공간변용 특성에 관한 연구 - 대전 둔산 신시가지를 중심으로 -)

  • Park, Jung-A;Kang, In-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.123-130
    • /
    • 2010
  • The purpose of this study is to find the characteristics of space utilization and the problems that follows after converting in a new developmental residential area. This study used the content-analysis method and analysis was made on the floor plans for 95 different conversion cases. Above all, 190 unit plans (the unit plans for conversion before and after) were analyzed. The results of this study were as follows; 1) There were 8 types of conversion according to such usages as residential, commercial and residential-commercial buildings. 2) In the case of conversions, from residential to commercial, there was a tendency each floor was integrated to exclusive use for commercial or commercial with small portions of residential usage. And in the case of conversions from commercial to residential, there was a tendency that all space of each floor were changed to exclusive usages for residential purposes. 3) In case of usage conversion from commercial to residential, there were constraints for balcony installation, because of its original lot-structure and building equipments. Also, when the basement was converted for residential purpose, there was no possibility for an extra lighting or ways to ventilate the area.

Assessment of indoor ventilation in commercial office buildings (업무용 빌딩 소재 사무실의 실내환기 평가)

  • Jeong, Jee Yeon;Lee, Gwang Yong;Lee, Byung Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.2
    • /
    • pp.115-121
    • /
    • 2008
  • In winter season, the survey was performed in three commercial office buildings in the metropolitan Seoul, Pusan, and Gwangju city. The purpose of the survey was to evaluate the effectiveness of ventilation for offices in commercial buildings. The data were compared to standard of applicable to the indoor ventilation in office. The results indicated that the most commercial office buildings used the air handing unit and fan coil unit as HVAC system, and the intake amount of fresh outdoor air were very inadequate to compared to the ASHRAE standard value of $0.57\;m^3/min/person$. Also the surveyed all commercial office building used the HVAC system as a meas of controlling temperature for office indoor air. Ultimately, these results presented that there were possibility of evoking indoor air quality problems by the insufficient ventilation.