the Application and Structural Behavior of Ultra High Strength Concrete on Sam Sung Sin-Dae Bang project. (초고층 주상복합 건물에의 초고강도 콘크리트의 시공 및 구조적 성능)

  • 신성우;이광수;최종수;유석형;안종문;윤영수;성상래;백승준;이승훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.313-318
    • /
    • 1994
  • This paper present the application and Structural Behavior of Ultra-High Strength Concrete on Samsung Sin Dae-Bang Housing-Commercial Combined building with 28 story including 8 story basement in seoul. 70 MPa compressive strength has been placed for all 8 basement shear wall. 42 MPa design strength concrete was used for other basement and frame up to 10th floor which us used for commercial purposes

  • PDF

Evaluating Spatiality of Green-House Gas Emission in Building Site ("대" 지목에 의거한 온실가스 분포의 공간성 평가)

  • Kim, Jun-Hyun;Um, Jung-Sup
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2010.06a
    • /
    • pp.94-102
    • /
    • 2010
  • These days the land category is the most specific basis of legal for land use or land use form that is determined by the main use of land. Even if same land building site, it is used very various like a detached house, a row house, a multiplex house, a villa, an apartment, a mixed-use Apartments, commercial building, fallow land etc. There is a need of variety analysis in order to apply greenhouse gas emission or statistics assessment for standard of classification. Therefore, This study measured carbon dioxide by for different government agencies of maps by land use time, season, elevation, space, area of floating population. As a result, The emission characteristic was high l.78 times, on average of l.35 times in winter compared with summer, when the temperatures increased 11C, the carbon dioxide is 22ppm high in the afternoon, A commercial building is high 4.04 times compare with detached house.

  • PDF

Asbestos Content in Friable Sprayed-on Surface Material and Airborne Fiber Concentrations in Commercial Buildings (대형건물내 비고형 석면함유 건축자재에 의한 기중 석면오염 및 관리실태)

  • Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.137-146
    • /
    • 1995
  • Twenty(20) large commercial buildings located in Seoul with friable sprayed-on surface insulation material on ceilings were investigated for asbestos content in bulk material by polarized light microscopy and for airborne fiber concentrations in buildings by phase contrast microscopy. In addition, such building-related variables as building age, numbers of traffic, airflow, surface conditions of the ceiling, temperature, and humidity were studied for any correlation with airborne fiber concentrations. The results were as follows: 1. Chrysotile asbestos was found in two bulk samples with 3-5% content and with <1%in one sample out of total 20 bulk samples collected. Glass fiber and mineral wool were the two major constituents of the bulk samples. 2. The ceiling surfaces were very friable in 16 buildings and were relatively hard in 4 buildings. The friability of the surface material was dependent upon the type and the amount of binder that had been mixed with the sprayed-on surface material. 3. Airborne fiber concentrations were log-normally distributed and the geometric mean(geometric standard deviation) fiber concentrations in the underground parking lots, inside buildings, and outdoor ambient air were 0.0063(1.97)f/cc, 0.0068(2.29)f/cc, and 0.0033(2.36)f/cc, respectively. 4. No significant relationship of airborne fiber concentrations and all building-related variables studied except humidity was found. The results of this study suggest that the sprayed-on surface insulation material found in some commercial buildings may possibly be contaminated with asbestos. Since most of the ceiling surfaces surveyed were very friable and poorly maintained and the airborne fiber concentrations were relatively high, there is a possibility of asbestos fiber contamination in these buildings, particularly at those buildings with asbestos-contaminated surface material. Since poorly maintained surface conditions were thought to be a source of high airborne fiber concentrations, there is a urgent need of a systematic operation and maintenance program. Further study of non-occupational asbestos exposure in general population utilizing advanced analytical technique such as transmission electron microscopy is highly recommended.

  • PDF

A Study on the Rent Characteristics of Small Shopping Malls

  • KIM, Sun-Ju
    • Journal of Distribution Science
    • /
    • v.20 no.12
    • /
    • pp.109-116
    • /
    • 2022
  • Purpose: The purpose of this study is to analyze the rental determinants of a small shopping mall located in Seoul, Korea, and the characteristics of four commercial districts (CBD, GBD, YSD, etc.). Research design, data, and methodology: For the characteristics of the data, descriptive statistics and frequency analysis were used. Artificial Neural Networks (ANNs) have been used as rental determinants for small shopping malls. The characteristics of 4 commercial districts were analyzed using Analysis of variance (ANOVA) and post-hoc analysis. Results: 1) CBD 14.8%, GBD 16.7%, YSD 13.0%, others 55.6%. 2) The order of important variables affecting rent: CBD=1> GBD=1> vacancy rate> rental index> number of buildings> YBD=1> average gross floor area> conversion rate> average floor. 3) Characteristics of commercial district: Rents in CBD and GBD are high. The conversion rate is high in the GBD commercial area. The number of buildings is high in the CBD. The average area of GBD is larger than that of other commercial districts. Conclusions: 1) Several factors should be considered when investing in or renting a small shopping mall. 2) Depending on the investment and business purpose, factors such as rent, conversion rate, building, and area average should be considered.

Conceptual Design of Intelligent Building Automation System Using Computer-Aided Systems Engineering Approach (시스템공학 접근법을 이용한 지능형 건물 자동화 시스템의 개념설계)

  • 유일상;박영원
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.166-178
    • /
    • 2000
  • As the 21st century signifies an information-oriented society, the computer integration takes place in all walks of human presence. Needs for computer and network-integrated automation present new challenges in military as well as commercial facility systems engineering. Since the first intelligent building appeared in USA in 1984, it gradually became an essential capability for the building industry requirement these days. Intelligent Building System(IBS) is evolving to be very complex because there are many subsystems such as telecommunication(TC), office automation(OA), building automation(BA), security, construction environments, etc. During the planing phase of IBS development, therefore, a disciplined systems engineering must be performed to analyze stake- holder's requirements to build an optimized system while minimizing trial-and-error expenses and risks. This paper presents a conceptual design of BAS applying systems engineering methods. The contribution of this study includes the development of IBS subsystem specification for building automation subsystem, which is a part of IBS, using the methodology of requirement analysis, functional analysis, synthesis, and verification. A computer-aided systems engineering s/w, RDD-100, was used to improve the system design efficiency and to promote the product design knowledge management for reuse in later design programs.

  • PDF

Structural Design and Construction of High-rise Building to Feature the High-performance Oil Dampers for Vibration Control - Hibiya Mitsui Tower -

  • Kato, Takashi;Hara, Kenji;Tanaka, Hiroyuki
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.229-234
    • /
    • 2019
  • This report introduces the structural design of Hibiya Mitsui Tower built in Tokyo Midtown Hibiya. The upper part of this tower is used for offices and the lower portion is for commercial facilities and a cinema complex which need the large open spaces. The 192m-high building has 35 floors above ground and 4 below ground. The structure is a steel frame using CFT columns to feature the high-performance oil dampers and the buckling restrained braces for vibration control. First, an outline of the structural design of this building is presented. Second, we introduce the transfer frame adopted to realize the large open spaces in the lower part, and the long column supporting the corner part of the high-rise building to avoid making a shade on the adjacent Hibiya Park, which are the feature of this building. Finally, we present an outline of the latest highly efficient semi-active oil dampers adopted in this building, and the vibration responses of this tower.

Estimation and Feature of Greenhouse Gas Emission in Building Sector by National Energy Statistic (국가 에너지통계에 따른 건물부문 온실가스 배출량 추계 및 특성)

  • Jeong, Young-Sun;Kim, Tae-Hyoung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.187-195
    • /
    • 2019
  • In December 2015, The Paris Agreement was adopted to undertake ambitious efforts to combat climate change. Korean government announced its goal of reducing the country's greenhouse gas emissions by up to 37% below business as usual projections by 2030 in 2015. The purpose of this study was to set up the calculation methodology of GHG emission($CO_{2e}$) in building sector and to estimate the annual GHG emission in building sector based on national energy consumption statistic. The GHG emission from buildings is about 135.8 million ton $CO_{2e}$ as of 2015, taking up about 19.6% of Korea's entire emission and is about 144.7 million ton $CO_{2e}$ in 2017. The GHG emission of building sector is increasing at annual rate of 2.0% from 2001 to 2017. The GHG emission from electricity consumption in buildings is 91.8 million ton $CO_{2e}$ in 2017, is the highest $CO_2$ emission by energy source. The results show that the intensity of GHG emission of residential building sector is $40.6kg-CO_{2e}/m^2{\cdot}yr$ and that of commercial building sector is $68.4kg-CO_{2e}/m^2{\cdot}yr$.

Anomaly Detection and Diagnostics (ADD) Based on Support Vector Data Description (SVDD) for Energy Consumption in Commercial Building (SVDD를 활용한 상업용 건물에너지 소비패턴의 이상현상 감지)

  • Chae, Young-Tae
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.579-590
    • /
    • 2018
  • Anomaly detection on building energy consumption has been regarded as an effective tool to reduce energy saving on building operation and maintenance. However, it requires energy model and FDD expert for quantitative model approach or large amount of training data for qualitative/history data approach. Both method needs additional time and labors. This study propose a machine learning and data science approach to define faulty conditions on hourly building energy consumption with reducing data amount and input requirement. It suggests an application of Support Vector Data Description (SVDD) method on training normal condition of hourly building energy consumption incorporated with hourly outdoor air temperature and time integer in a week, 168 data points and identifying hourly abnormal condition in the next day. The result shows the developed model has a better performance when the ${\nu}$ (probability of error in the training set) is 0.05 and ${\gamma}$ (radius of hyper plane) 0.2. The model accuracy to identify anomaly operation ranges from 70% (10% increase anomaly) to 95% (20% decrease anomaly) for daily total (24 hours) and from 80% (10% decrease anomaly) to 10%(15% increase anomaly) for occupied hours, respectively.

A Study for Transfer Girder Details of the Upper-Wall and Lower-Frame Structures (주상복합구조의 전이보 상세설계기법 연구)

  • 이한선;김상연;고동우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.529-534
    • /
    • 2000
  • Hybrid building structure, which comprise both the residential and commercial spaces in a building, are composed of upper shear-walls and lower frames. In these hybrid structures, the structural analysis and design of transfer systems which link upper-wall and lower-frame are crucial. The available structural design methods for the transfer girder are performed by taking a prototype structure, and the details of transfer girder based on these design methods are presented and compared with regard to the dimensions and amount of reinforcements.

  • PDF

Inductive Sensor and Target Board Design for Accurate Rotation Angle Detection

  • Hwang, Jae-Jeong;Moon, Joon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.1
    • /
    • pp.64-70
    • /
    • 2017
  • In the commercial building such as huge enterprise building, more accurate operation of the center-controlled roller blind. We design, in this work, the target disc that its shape is nonlinearly changing and the sensor coils that are differentially arranged. The performance shows less than 1% accuracy when it is implemented in the roller blind.