• Title/Summary/Keyword: Commercial Center

Search Result 2,281, Processing Time 0.028 seconds

Development of Lateral Flow Immunoassay for Antigen Detection in Human Angiostrongylus cantonensis Infection

  • Chen, Mu-Xin;Chen, Jia-Xu;Chen, Shao-Hong;Huang, Da-Na;Ai, Lin;Zhang, Ren-Li
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.3
    • /
    • pp.375-380
    • /
    • 2016
  • Angiostrongyliasis is difficult to be diagnosed for the reason that no ideal method can be used. Serologic tests require specific equipment and are not always available in poverty-stricken zone and are time-consuming. A lateral flow immunoassay (LFIA) may be useful for angiostrongyliasis control. We established a LFIA for the diagnosis of angiostrongyliasis based on 2 monoclonal antibodies (mAbs) against antigens of Angiostrongylus cantonensis adults. The sensitivity and specificity were 91.1% and 100% in LFIA, while those of commercial ELISA kit was 97.8% and 86.3%, respectively. Youden index was 0.91 in LFIA and 0.84 in commercial ELISA kit. LFIA showed detection limit of 1 ng/ml of A. cantonensis ES antigens. This LFIA was simple, rapid, highly sensitive and specific, which opened an alternative approach for the diagnosis of human angiostrongyliasis.

Experimental Evaluation of Filter Performance of Depth Filter Media Cartridge with Varying the Pleat Count and the Cartridge Assembly Arrangement

  • Hasolli, Naim;Park, Young-Ok;Rhee, Young-Woo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.133-141
    • /
    • 2012
  • A new depth filter media was designed and samples of flat sheet as well as cartridge assembly were prepared and tested to evaluate the filtration performance and compare with the commercial product. The arrangement of the depth filter media layers is important to reach the optimal filtration parameters like filter pressure drop, particle collection efficiency and dust holding capacity. Initially, both flat sheet samples of new media and commercial product have been tested using standard test units. Tests with new depth filter media cartridges of various pleat count were conducted in order to find the optimal pleat count which would represent the lowest pressure drop. These tests give an insight on how the pleat count and the assembly configuration affect the performance of the depth filter media cartridge. By comparing the samples with a commercial product we could confirm relatively high filtration performance of the sample cartridge with pleat count 150 made of new depth filter media. The cartridge with the same pleat count exhibits better performance without the outer mesh.

A Study on the Structural Strength Fatigue Improvement of an Axle Shaft for a 3.5-Ton Commercial Vehicle (3.5톤 상용차용 액슬샤프트의 피로강도 개선에 대한 연구)

  • Moon, Hong-Ju;Sim, Ki-Joong;Jeon, Namjin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.3
    • /
    • pp.71-77
    • /
    • 2018
  • This paper suggests how to improve the fatigue strength of an axle shaft, which is the vulnerable part of an axle shaft system for a 3.5-ton commercial vehicle. The axle shaft is composed of a universal joint with a spider and yoke, yoke shaft, and so on. Structural analysis of the initial axle shaft was conducted to select the exact area for structural strength fatigue improvement, and as a result, the inner/outer yoke shaft and spider were selected. Four cases considered design variables, such as length and thickness, to verify the enhanced durability of the axle shaft, and fatigue analysis was conducted. Finally, we suggest that the axle shaft system satisfied the working conditions for a 3.5-ton commercial vehicle.

Current status in molecular farming (분자농업의 현황 및 전망)

  • Kim, Tae-Geum;Yang, Moon-Sik
    • Journal of Plant Biotechnology
    • /
    • v.37 no.3
    • /
    • pp.243-249
    • /
    • 2010
  • Molecular farming is production of pharmaceutically and industrially important proteins in plants. Plants and plant cell culture systems have been used as bio-factory to produce recombinant proteins such as monoclonal antibodies, enzymes, vaccines, hormones, interleukins, commercial enzymes and etc. The terms molecular farming, biofarming, molecular pharming, phytomanufacturing, recombinant or plant-made industrials, planta-pharma, plant bioreactors, plant biofactory, and pharmaceutical gardening are used interchangeably. Molecular farming can provide safe and inexpensive pharmaceutical proteins as well as commercial ones. In spite of several advantages of molecular farming such as safety and inexpensive cost, there are also a couple of drawbacks in the existing technology. One of them is low expression level of target gene in plants, which has been improved by optimizing gene-based codon usage, screening of strong promoters, expression of transcription factors, subcellular targeting of target proteins, chloroplast transformation, and transient expression using viral expression system (magnifection). Some plant-based commercial proteins have already been in markets and more than twenty plant-based pharmaceuticals have been in clinical trials, from that we can expect that several plant-based pharmaceutical proteins will be seen in the markets in the near future.

Quality Characterization of Commercial Flounder Verasper moseri Jordan et Gilberu Sikhae (시판 가자미(Verasper moseri Jordan et Gilberu)식해의 품질 특성)

  • Han, Dae-Won;Han, Ho-Jun;Kim, Deok-Gi;Im, Mi-Jin;Cho, Soon-Yeong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.46 no.6
    • /
    • pp.696-701
    • /
    • 2013
  • Flounder Verasper moseri Jordan et Gilberu sikhae is one of the traditional Korean fermented food. Microbiological, chemical, and biogenic amine analyses were carried out to evaluate the quality of commercial flounder sikhae and establish standardization. The quality characteristics were analyzed in terms the salinity, volatile basic nitrogen, pH, amino-N, TBA value, biogenic amine, viable cell count, and lactic acid bacteria. Quality evaluation of commercial flounder sikhae revaled an average pH of 4.84, volatile basic nitrogen of 43.47 mg/100 g, amino-N of 213.04 mg/100 g, salinity of 5.77 %, viable cell count of $10^6-10^7CFU/g$, viable lactic acid bacteria count of $10^6-10^7CFU/g$ and biogenic amine level of 0.70-47.34 mg/kg.

Comparative Study on the Stability of Amoxicillin, Clavulanic Acid and its Commercial Combination Products (아목시실린, 클라불란 산 및 시판 아목시실린-클라불란 산 복합제제의 안전성 비교연구)

  • Han, Sang-Dug;Kim, Chong-Kook
    • YAKHAK HOEJI
    • /
    • v.49 no.5
    • /
    • pp.392-398
    • /
    • 2005
  • In this study, we evaluated the stability of amoxicillin (AMX) and clavulanic acid (CLA) in aqueous solution, and compared the stability of AMX and CLA in commercial combination products. In aqueous solutions, the degradation of AMX ($t_{90}=8.88\;day\;at\;10^{circ}C$) and CLA ($t_{90}=3.53\;day\;at\;10^{circ}C$) occurred rapidly. From the pH-rate profile, AMX and CLA were the most stable at the range of pH 5.5 and 6.0. After reconstitution of commercial dry syrups, the contents of AMX and CLA in suspensions were gradually decreased for 7 days. However, AMX and CLA in dispersible tablet were not changed at all. The contents of CLA in the dispersible tablet ($87.92\%$) and dry syrups (2.16 and $3.91\%$) were remained in the accel­erated stability test ($75\%\;RH,\;at\;40^{circ}C$) after 10 hours. And the colors of the dry syrups were rapidly changed from white to yellow. From these results, we concluded that the dispersible tablet could overcome the stability problems of dry syrups.

Characteristics of phosphorescent OLEDs and flexible OLED fabricated indium-zinc-tin-oxide anode (IZTO 애노드를 이용하여 제작한 인광 OLED 및 플랙시블 OLED 특성)

  • Choi, Kwang-Hyuk;Bae, Jung-Hyeok;Moon, Jong-Min;Jeong, Jin-A;Kim, Han-Ki;Kang, Jae-Wook;Kim, Jang-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.399-400
    • /
    • 2007
  • In this work, we have investigated the characteristics of the phosphorescent OLED and flexible OLED fabricated on IZTO/glass and IZTO/PET anode film grown by magnetron sputtering, respectively. Electrical and optical characteristics of amorphous IZTO/glass anode exhibited similar to commercial ITO anode even though it was deposited at room temperature. In addition, the amorphous IZTO anode showed higher work function than that of the commercial ITO anode after ozone treatment for 10 minutes. Furthermore, a phosphorescent OLED fabricated on amorphous IZTO anode film showed improved current-voltage-luminance characteristics, external quantum efficiency and power efficiency in contrast with phosphorescent OLED fabricated on commercial ITO anode film. This indicates that IZTO anode is promising alternative anode materials for anode in OLEDs and flexible OLEDs.

  • PDF

Change of the Kyeong-seong-bu Administration Office's former Site after the Office's Moving out in 1926 -From a Administrative Center to a Commercial Center- (1926년 경성부청 이전 후 옛 청사 터의 변화 -행정 중심지에서 상업 중심지로 -)

  • Kim, Myungsun
    • Journal of architectural history
    • /
    • v.28 no.2
    • /
    • pp.19-30
    • /
    • 2019
  • The former administration office building of Kyeong-seong-bu(京城府) was a building converted from the Japanese residency-general's of Kyeong-seong(京城理事廳) which was originally built as the Japanese consulate in Joseon(日本領事館). It was too worn and too small as a Kyeong-seong-bu administration office even with several annexes. Kyeong-seong-bu tried to build a new big administration office building at the vacant north side of the same site, which was closely faced to the rotary in front of the Bank of Joseon(朝鮮銀行前廣場). But this trial was ended in vain due to insufficient budget. Therefore Kyeong-seong-bu built a new administration office building in another site and moved to it in 1926 with debts. For paying for the debts Kyeong-seong-bu sold the former site after partitioning with new roads through it. As a result the nature of the former site and its surroundings was changed. This study traces the changes and inquires how the authorities in the colonial Joseon and various commercial powers of Kyeong-seong-bu behaved for their own interests in the meantime. It makes use of the historical records and documentary literatures between early 1910s and early 1930s.

Investigation of Single Nucleotide Polymorphisms in Porcine Candidate Genes for Economic Traits in the Commercial Pig Breed (돼지 품종의 경제형질 관련 후보유전자의 단일염기 다형성에 관한 연구)

  • Kim, Sang-Wook;Lee, Mi-Rang;Kang, Han-Seok;Kim, Seon-Ku;Shin, Teak-Soon;Lee, Hong-Gu;Jeon, Hae-Yeal;Kim, Kwan-Suk;Do, Chang-Hee;Choi, Bong-Hwan;Kim, Tae-Hun;Cho, Byung-Wook
    • Journal of Life Science
    • /
    • v.18 no.6
    • /
    • pp.770-775
    • /
    • 2008
  • Several studies reported quantitative trait loci (QTL) for meat quality on porcine chromosome 2. For application of the chromosomal information to pig industry through using DNA technology, single nucleotide polymorphism (SNP) markers are developed by comparative re-sequencing of polymerase chain reaction (PCR) products of 13 candidate genes. A total of 34 SNPs were identified in 11 PCR products, an average of one SNP in every 296 bp.PCR restriction fragment length polymorphism (RFLP) assays were developed for 11 SNPs and used to genotype four commercial pig populations in Korea. The SNP markers were used to map candidate genes in QTL and to clarify the relevance of SNP and quantitative traits.

Evaluation of Irritating Potential of Newly Developed Toothpaste in the Hamster Oral Mucous Membrane

  • Kim, Bae-Hwan;Kim, Jin-Woo;Chang, Ih-Seop;Sim, Young-Chul;Lee, Yong-Soon
    • Toxicological Research
    • /
    • v.17 no.3
    • /
    • pp.167-171
    • /
    • 2001
  • Oral mucous membrane test using Syrian hamsters was performed to evaluate the reliability as a model system for the assessment of the potentially irritating substances intended for the mucous membranes, and to determine the irritating potential of a new emulsion-type formulated toothpaste. After test substances were implanted into the cheek pouches of hamsters with diluents (20 mg/kg) under pento-barbital sodium anesthesia, we made the comparison in irritation between emulsion-type and dispersion-type of triclosan (TCS) formulations in the range of 0.2% to 0.3%. The emulsion-type formulations using non-ionic surfactant showed less mucosal lesion than other commercial toothpastes with 0.3% TCS, or dispersion-type ones. However, no significant difference in irritation was detected between 0.2% and 0.3% TCS. We report that this hamster cheek pouch method could be a reliable approach for the evaluation slight difference in the irritating potentials of cosmetics and hygiene products intended for the lips or other mucous membranes, and this method showed that the new emulsion-type formulation significantly lowered the TCS-induced toxicity, compared with other commercial toothpastes.

  • PDF