• 제목/요약/키워드: Comfort level

검색결과 475건 처리시간 0.028초

축냉 시스템이 차 실내 열 쾌적성에 미치는 영향에 관한 실험적 연구 (Experimental Study of the Effect on Cabin Thermal Comfort for Cold Storage Systems in Vehicles)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제23권4호
    • /
    • pp.428-435
    • /
    • 2015
  • This paper presents the experimental study of cabin thermal comfort using a cold storage heat exchanger in a vehicle air-conditioning system. Recent vehicle-applied ISG functions for fuel economy and emission, but when vehicles stop, compressors in the air-conditioning system stop, and the cabin temperature sharply increases, making passengers feel thermal discomfort. This study conducts thermal comfort evaluation in the vehicle, which is applied to a cold storage system for the climate control wind tunnel test and the vehicle fleet road test with various airflow volume rates and ambient temperatures blowing to the cold storage heat exchanger. The experimental results, in the cold storage system, air discharge temperature is $3.1-4.2^{\circ}C$ lower than current air-conditioning system when the compressor stops and provides cold air for at least 38 extra seconds. In addition, the blowing airflow volume to the cold storage heat exchanger with various ambient temperature was examined for the control logic of the cold storage system, and in the results, the airflow volume rate is dominant over the outside temperature. For this study, a cold storage system is economically useful to keep the cabin at a thermally comfortable level during the short period when the engine stops in ISG vehicles.

성능시험을 통한 경전철 차량의 주행특성 비교 고찰 (A Comparison on Running Characteristics of Light Rail Transit Vehicles through Performance Test)

  • 전창성;전홍규;김영국;박태원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.47-50
    • /
    • 2011
  • Test Results of noise, ride comfort and vibration tests are investigated for three kinds of light rail transit vehicles which have passed the performance test and the test criteria has been satisfied. Noise level of light rail transit vehicles was 64~69dB(A) at stop and 74~75dB(A) when operated at full speed. The ride comfort index according to UIC 513R was 2.02 to 2.45. Vibration level of rubber tired light rail transit vehicle was from 'normal' to 'good' and that of iron wheel light rail transit vehicle was 'good' to 'excellent'. These data are the results for three kinds of light rail transit vehicles and more data can be accumulated after further performance test. These data can be used for a reference for the design of light rail transit vehicles.

  • PDF

Measurement of Dynamic Contact Angle of Yarn for Evaluation of Fabric Comfort Performance

  • Hong, Cheol-Jae
    • 감성과학
    • /
    • 제5권3호
    • /
    • pp.67-74
    • /
    • 2002
  • Testing device was newly designed and built to measure the dynamic contact angle. The measurement was made using microscope interfaced with computerized image analysis system while the dynamic condition being controled using Instron. As specimens for the experiment, two different types of fibers, i.e., hydrophilic and hydrophobic, were prepared. In case of hydrophilic fiber, the increase of twist level gave the increase of contact angle. However, in hydrophobic yarn the increase of twist level gave the decrease of contact angle. When saline was used as a telling liquid, the increase of the concentration gave the increase of contact angle. The results rationalized clearly on the basis of known concepts could be used in designing fabric structure for the improvement of comport performance.

  • PDF

통증치료를 위한 신경차단과 부위 마취시 Anesthesiologist Controlled Sedation과 Patient Controlled Sedation의 비교 (Comparison of Anesthesiologist Controlled Sedation and Patient Controlled Sedation during Neurolytic Pain Block and Regional Anesthesia)

  • 김익곤
    • The Korean Journal of Pain
    • /
    • 제7권2호
    • /
    • pp.199-204
    • /
    • 1994
  • The purpose of this study is to evaluate the feasibility, advantages/disadvantages of patient-controlled sedation (PCS) compared to anesthesiologist-controlled sedation (ACS) during neurolytic pain block and regional anesthesia. Forty patients were divided randomly into two groups of 20 patients each. Group 1(ACS) received 0.01 $mg{\cdot}kg^{-1}$ intravenous midazolam and 0.5 ${\mu}g{\cdot}kg^{-1}$ fentanyl intravenously by anesthesiologist just before, 30, and 60 minutes after the procedure to acheive sedation; Group 2 (PCS) patients self-administered a mixture of midazolam (0.4 mg) and fentanyl ($20{\mu}g$) using a syringe type infusion pump (Terumo, Japan) to acheive sedation. Considering the dermographics of patients, the types and durations of procedure performed, the level of average sedation the comfort level were similar in both groups. But the doses of midazolam and fentanyl administerd in group 2 were smaller than those in group 1 (p<0.01). Patients in PCS group showed their level of sedation more proper than did those in ACS group. However, patients in ACS group rated their level of comfort higher than did those in PCS group. The findings of this study indicate that PCS using a combination of midazolam and fentanyl is a fafe and effective technique. More studies are, however, needed to determinc the best choice of drug(s), doses, lock-out intervals, and possible use of continuous infusion with patient-controlled sedation.

  • PDF

순차적 냉·온 요법이 척추 수술 후 통증과 통증 조절 만족도, 안위, 주관적 반응에 미치는 효과 (Effects of Sequential Application of Superficial Cold and Heat on Pain, Patient Satisfaction with Pain Control, Comfort Level and Subjective Response after Spine Surgery)

  • 김정희;임승철;노성우;이순진;고영미;김여옥;신용순
    • 기본간호학회지
    • /
    • 제23권2호
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: The aims of the current study were to evaluate the effects of superficial cold and heat after spine surgery on pain, satisfaction with pain control and comfort level, and to identify subjective responses and adverse effects. Methods: A prospective, single-blind, randomized controlled trial was utilized. The intervention group (n=36) received superficial cooling until the wound drain was removed and thereafter followed by superficial heating until discharge, while the control group (n=34) received only superficial cooling until wound drain was removed. Data were collected from August 4 to November 11 2014. Results: There was significant difference in pain according to time within groups (F=71.87, p<.001). However, we found no difference in pain between groups. The intervention group reported higher patient satisfaction with pain control (4 vs 3, z=-2.83, p=.005) and higher comfort level (5 vs 4, z=-4.12, p<.001) than the control group. Conclusion: Results indicate that sequential application of superficial cold and heat is a useful method in clinical practice for management of pain after spine surgery.

두개의 제어기를 사용한 건물 내부의 온도변화와 에너지소비량을 계산하기 위한 해석적 연구 (A study on the analytical method for calculating the inside air temperature transient and energy consumption load of the building using two different controllers)

  • 한규일
    • 수산해양기술연구
    • /
    • 제48권1호
    • /
    • pp.82-90
    • /
    • 2012
  • Four different buildings having various wall construction are analyzed for the effect of wall mass on the thermal performance and inside building air and wall temperature transient and also for calculating the energy consumption load. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one-dimensional, linear, partial differential equations is obtained using the Laplace transform method, Bromwich and modified Bromwich contour method. A simple dynamic model using steady state analysis as simplified methods is developed and results of energy consumption loads are compared with results obtained using the analytical solution. Typical Meteorological Year data are processed to yield hourly average monthly values. This study is conducted using weather data from two different locations in Korea: Daegu having severe weather in summer and winter and Jeju having mild weather almost all year round. There is a significant wall mass effect on the thermal performance of a building in mild weather condition. Buildings of heavyweight construction with insulation show the highest comfort level in mild weather condition. A proportional controller provides the higher comfort level in comparison with buildings using on-off controller. The steady state analysis gives an accurate estimate of energy load for all types of construction. Finally, it appears that both mass and wall insulation are important factors in the thermal performance of buildings, but their relative merits should be decided in each building by a strict analysis of the building layout, weather conditions and site condition.

Ride Quality Investigation of Passenger Cars on Different Road Conditions

  • Park, Se Jin;Subramaniyam, Murali
    • 대한인간공학회지
    • /
    • 제32권4호
    • /
    • pp.389-396
    • /
    • 2013
  • Objective: The ride qualities of the six passenger cars were evaluated in 4 subjects on the highway and uneven road. The relation between vibration with driving velocity and driving posture were also investigated separately. Background: Ride comfort plays an important role in the vehicle design. Vibration is the one of the principal components associated with ride comfort. Method: The acceleration of the foot, hip and back were measured using B&K accelerometers in this study. The velocity of the passenger cars was maintained at a constant speed of 80km/h on the highway and 40km/h on the uneven road. For evaluating the effects of driving velocity and driving posture on vehicle's vibration level, separate experiments were performed on the highway with 5 different vehicle speeds and 5 different backrest angles, respectively. Results: The overall ride value of the luxury car showed the best result while the smaller car showed the worst value on the highway. On the uneven road the overall ride value level was increased 75~98%. All the vehicles had the SEAT value less than 1. Faster the velocity lowers the SEAT value. The ride quality in terms of vibration gets worst when the backrest angle increased. Conclusion: The smaller car had a first mode at the higher frequency and showed higher vibration level. SEAT value was mostly affected by the seat property not by vehicle. We ranked the luxury car seat had a best vibration reduction quality than others based on SEAT values. When the driving velocity increased, the overall ride values were increased proportionally and the SEAT values were somewhat decreased. Application: Evaluation of whole-body vibration in the passenger car.

The Effects of Hearing Aid Digital Noise Reduction and Directionality on Acceptable Noise Level

  • Ahmadi, Roghayeh;Jalilvand, Hamid;Mahdavi, Mohammad Ebrahim;Ahmadi, Fatemeh;Baghban, Ali Reza Akbarzade
    • Clinical and Experimental Otorhinolaryngology
    • /
    • 제11권4호
    • /
    • pp.267-274
    • /
    • 2018
  • Objectives. Two main digital signal processing technologies inside the modern hearing aid to provide the best conditions for hearing aid users are directionality (DIR) and digital noise reduction (DNR) algorithms. There are various possible settings for these algorithms. The present study evaluates the effects of various DIR and DNR conditions (both separately and in combination) on listening comfort among hearing aid users. Methods. In 18 participants who received hearing aid fitting services from the Rehabilitation School of Shahid Beheshti University of Medical Sciences regularly, we applied acceptable noise level (ANL) as our subjective measure of listening comfort. We evaluated both of these under six different hearing aid conditions: omnidirectional-baseline, omnidirectional-broadband DNR, omnidirectional-multichannel DNR, directional, directional-broadband DNR, and directional-multichannel DNR. Results. The ANL results ranged from -3 dB to 14 dB in all conditions. The results show, among all conditions, both the omnidirectional-baseline condition and the omnidirectional-broadband DNR condition are the worst conditions for listening in noise. The DIR always reduces the amount of noise that patients received during testing. The DNR algorithm does not improve listening in noise significantly when compared with the DIR algorithms. Although both DNR and DIR algorithms yielded a lower ANL, the DIR algorithm was more effective than the DNR. Conclusion. The DIR and DNR technologies provide listening comfort in the presence of noise. Thus, user benefit depends on how the digital signal processing settings inside the hearing aid are adjusted.

실습선 가야호의 선체진동에 대한 승선환경 (Boarding environment of training ship KAYA for the hull vibration)

  • 김민선;신현옥;김민석;한진석
    • 수산해양기술연구
    • /
    • 제45권1호
    • /
    • pp.46-55
    • /
    • 2009
  • To compare and evaluate the suitability and comfort levels of the environment on board a stern trawl training ship, KAYA(GT: 1737 tons, Pukyong National University), with the international standardization guide ISO 6954:2000(E), measurements of the hull vibration on accommodation areas and working areas of the training ship from July 8 to July 10, 2008 were completed upon KAYA's linear sea route. The vibrations along the z-axis were measured with the use of a 3-axis vibration level meter, which included a marine vibration card. Results show accelerations of the vibrations on the passenger's accommodation area to be 42.0-115.8(average: 78.0, standard deviation(SD): 21.0) mm/$s^2$, which is largely below the permissible upper limit, but 75 % of the observation points exceeded the permissible lower limit of 71.5 mm/$s^2$, indicating a comfortable environment. The accelerations of the vibration in a frequency of 10-24Hz lowering the visual performance were measured at 2.5-12.0(average: 7.6, SD: 3.1) mm/$s^2$. The crew s accommodation area experienced vibration accelerations of 42.9-82.3(average: 93.1, SD: 53.1) mm/$s^2$, which is generally below the permissible upper limit of 214.0 mm/$s^2$, and 62.5% of the observation points did not exceed the permissible lower limit of 107.0 mm/$s^2$, denoting a level of comfort. The acceleration of the vibration in a frequency of 10-24Hz were 4.7-28.3(average: 12.4, SD: 8.8) mm/$s^2$. On the crew s working area the accelerations were measured at 86.9-153.9(average 119.3, SD 18.0) mm/$s^2$. These values were generally below the permissible upper limit of 286.0 mm/$s^2$ and only 12.5% of the observation points did not exceed the permissible lower limit of 143.0 mm/$s^2$, the level at which a high level of comfort is maintained. The accelerations in frequency of 10-24Hz and 30Hz were 9.1-29.8 (average 13.8, SD= 4.5) mm/$s^2$ and 8.9-13.7 (average 11.8, SD 2.1) mm/$s^2$, respectively. In conclusion the boarding environment of the training ship was good in general although an improvement of the vibration condition partially needed on the crew s accommodation area near the engine room.

COVID-19 감염병 대응 의료진용 개인보호복의 동작성 및 생리적 부담 평가를 위해 개발된 모의 작업 프로토콜의 타당도 (Validity of a Simulated Practical Performance Test to Evaluate the Mobility and Physiological Burden of COVID-19 Healthcare Workers Wearing Personal Protective Equipment)

  • 권주연;조예성;이범휘;김민서;전영민;이주영
    • 한국의류산업학회지
    • /
    • 제24권5호
    • /
    • pp.655-665
    • /
    • 2022
  • This study evaluated the validity of a newly developed mobility protocol examining the comfort functions and requirements of personal protective equipment (PPE) for COVID-19 healthcare workers. Eight males (age: 24.7 ± 3.0 y, height: 173.4 ± 2.3 cm, and body weight 69.9 ± 3.7 kg) participated in the following three PPE conditions: (1) Plastic gown ensemble, (2) Level D ensemble, and (3) Powered air purifying respirator (PAPR) ensemble. The mobility protocol consisted of 10 different tasks in addition to donning and doffing. The 10 tasks were repeated twice at an air temperature of 25oC with 74% RH. The results showed significant differences among the three PPE conditions in mean skin temperature, local skin temperatures (the forehead, thigh, calf, and foot), clothing microclimate (the chest and back), thermal sensation, thermal comfort, and humidity sensation, while there were no significant differences in heart rate or total sweat rate. At rest, the subjects felt less warm and more comfortable in the PAPR than in the Level D condition (P<0.05). However, subjective perceptions in the PAPR and Level D conditions became similar as the tasks progressed and mean skin and leg temperature became greater for the PAPR than the Level D condition (P<0.05). An interview was conducted just after completing the mobility test protocol, and suggestions for improving each PPE item were obtained. To sum up, the mobility test protocol was valid for evaluating the comfort functions of PPE for healthcare workers and obtaining requirements for improving the mobility of each PPE item.