• Title/Summary/Keyword: Comfort Conditions

Search Result 454, Processing Time 0.027 seconds

A Study on the Integrated Dynamic Control System to Improve the Lateral Dynamics and Ride Comfort of SUV Vehicles (SUV 차량의 횡방향 운동 및 승차감 개선을 위한 제동장치를 이용한 통합운동제어장치의 연구)

  • Song, Jeonghoon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.70-75
    • /
    • 2018
  • This paper describes an Integrate Dynamic Control system with Brake System (IDCB) for SUV vehicles. The system was developed to stabilize the lateral dynamics, maintain the steerability and improve the ride comfort on various roads. A fuzzy logic control method is used to design the IDCB. The performance of the IDCB is validated under different road and driving conditions. The results show that the IDCB tracks the reference yaw rate under all tested conditions; in addition, it reduces the body slip angle and roll angle. When a vehicle runs on a split-${\mu}$ road and a brake input is applied, the IDCB virtually eliminates the lateral dynamics. Thus, the IDCB improves the lateral stability, preserves the steerability and enhances the ride comfort of vehicles.

Evaluation of abutment types on highway in terms on driving comfort

  • Nam, Moon S.;Park, Min-Cheol;Do, Jong-Nam
    • Geomechanics and Engineering
    • /
    • v.13 no.1
    • /
    • pp.43-61
    • /
    • 2017
  • The inverted T-type abutments are generally used in highway bridges constructed in Korea. This type of abutment is used because it has greater stability, with more pile foundations embedded in the bedrock, while simultaneously providing support for lateral earth pressure and vertical loads of superstructures. However, the cross section of inverted T-type abutments is large compared with the piers, which makes them more expensive. In addition, a differential settlement between the abutment and embankment, as well as the expansion joints, causes driving discomfort. This study evaluated the driving comfort of several types of abutments to improve driving comfort on the abutment. To achieve this objective, a traditional T-type abutment and three types of candidate abutments, namely, mechanically stabilized earth wall (MSEW) abutment supported by a shallow foundation (called "true MSEW abutment"), MSEW abutment supported by piles (called "mixed MSEW abutment"), and pile bent and integral abutment with MSEW (called "MIP abutment"), were selected to consider their design and economic feasibility. Finite element analysis was performed using the design section of the candidate abutments. Subsequently, the settlements of each candidate abutment, approach slabs, and paved surfaces of the bridges were reviewed. Finally, the driving comfort on each candidate abutment was evaluated using a vehicle dynamic simulation. The true MSEW abutment demonstrated the most excellent driving comfort. However, this abutment can cause problems with respect to serviceability and maintenance due to excessive settlements. After our overall review, we determined that the mixed MSEW and the MIP abutments are the most appropriate abutment types to improve driving comfort by taking the highway conditions in Korea into consideration.

Assessment of Thermal Comfort in a General Hospital in Winter Using Predicted Mean Vote (PMV) (Predicted Mean Vote(PMV)를 이용한 겨울철 종합병원의 실내 온·열 환경의 평가)

  • Lee, Boram;Kim, Jeonghoon;Kim, KyooSang;Kim, Hyejin;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.389-396
    • /
    • 2015
  • Objectives: A hospital is a complex building that serves many different purposes. It has a major impact on patient's well-being as well as on the work efficiency of the hospital staff. Thermal comfort is one of the major factors in indoor comfort. The purpose of this study was to determine thermal comfort in various locations in a hospital. Methods: Various indoor environmental conditions in a general hospital were measured in February 2014. The predicted mean vote (PMV) and carbon dioxide ($CO_2$) concentration were measured simultaneously in the lobby, office, restaurant, and ward. Results: The ward was the most thermally comfortable location (PMV=0.44) and the lobby was the most uncomfortable (PMV = -1.39). However, the $CO_2$ concentration was the highest in the ward (896 ppm) and the lowest in the lobby (572 ppm). The average PMV value was the most comfortable in the ward and the lowest in the lobby. In contrast, for concentration of carbon dioxide, the highest average was in the ward and the lowest in the lobby. Due to air conditioner operation, during operating hours the PMV showed values close to 0 compared to the non-operating time. Correlation between PMV and $CO_2$ differed by location. Conclusion: The PMV and concentration of carbon dioxide of the hospital lobby, office, restaurant and ward varied. The relationship between PMV and carbon dioxide differed by location. Consideration of how to apply PMV and carbon dioxide is needed when evaluating indoor comfort.

Evaluation of Annual Indoor Environment Quality in Hospitals using Various Comfort-related Factors (보건의료시설의 실내 예상 평균 온열감(PMV), 이산화탄소 농도, 소음도, 조도의 통합실내쾌적도(IEQh)를 통한 연간 실내 쾌적도 평가)

  • Lee, Boram;Lee, Daeyeop;Ban, Hyunkyung;Lee, Sewon;Kim, KyooSang;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.3
    • /
    • pp.214-222
    • /
    • 2017
  • Objectives: A hospital is a complex building that serves many different purposes. The indoor environment in a hospital plays a major role in patient well-being and the work efficiency of the hospital staff. This study was conducted to evaluate overall comfort in two major hospitals over the course of one year. Methods: Various indoor environmental conditions were measured in two general hospitals for one year (April 2014 to April 2015). Monitoring alternated between the hospitals at one month per respective monitoring session. The indoor air temperature, relative humidity (RH), mean radiant temperature and air velocity were measured in order to calculate the predicted mean vote (PMV). Carbon dioxide concentration, noise level and illumination level were concurrently measured and applied to the overall IEQ acceptance model for the hospitals (IEQh). Results: The IEQh at the two general hospitals was different at five spaces within a building. The IEQh for summer and winter were significantly different. Real-time IEQh demonstrated that indoor comfort was affected by the hospital's operating hours due to operation of the HVAC system. The percentage of indoor comfort in the hospitals was higher using PMV than IEQh. Conclusion: IEQh in the hospitals was different at locations with different purposes. Indoor comfort assessment using IEQh was stricter than with PMV. Additional research is needed in order to optimize the IEQh model.

A Study on Thermal Comfort of Korea Men감s Wear in Summer - Based on Indoor Environment conditions - (하계 남성복의 온열쾌적감에 관한 연구 - 실내 환경조건을 중심으로 -)

  • 정상열;고경태
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1997.10a
    • /
    • pp.364-368
    • /
    • 1997
  • The purpose of this Study was to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate Variability(HRV), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at 50% R.H., 24C, and the difference of skin temperature was found at the calf area as air temperature changes. At low air temperature and low humidity, heart rate was decreased, but there was no change at brain wave, keeping a-wave.

  • PDF

Changes in Moisture Permeability and Waterproofness of High-density Fabric by Repeated Laundering and Condition (고밀도 직물의 반복세탁 및 세탁조건에 따른 투습.발수성 변화)

  • Roh, Eui-Kyung;Han, Jung-Eun;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.11
    • /
    • pp.1798-1811
    • /
    • 2010
  • This research evaluates the changes in the comfort-related properties of high-density fabric, such as moisture permeability and waterproofness, in order to assess the relative importance of laundry conditions for clothing properties after repeated laundering and suggest the best laundering conditions for high-density fabric through the identification of the most influential factor. A commercial high-density fabric was washed 25 times in a drum-type washer using nine different laundry conditions based on profiles derived from a fractional factorial design. To evaluate the changes in the comfort-related properties of the fabric, pore size, air permeability, water vapor transport, water repellency, and water resistance were measured. The comfort-related properties of the fabric deteriorated after repeated laundering by the damaged surface finish; in addition, the damaged surface also changed the pore size. As a result, the water repellency and water resistance decreased. The detergent was the most responsible factor to change the properties among the four factors of detergent, hardness, temperature, and RPM. The best laundering conditions for the fabric was a neutral detergent, soft water of 70ppm, a temperature of $15^{\circ}C$, and 30rpm.

Challenges in Selecting an Appropriate Heat Stress Index to Protect Workers in Hot and Humid Underground Mines

  • Roghanchi, Pedram;Kocsis, Karoly C.
    • Safety and Health at Work
    • /
    • v.9 no.1
    • /
    • pp.10-16
    • /
    • 2018
  • Background: A detailed evaluation of the underground mine climate requires extensive measurements to be performed coupled to climatic modeling work. This can be labor-intensive and time-consuming, and consequently impractical for daily work comfort assessments. Therefore, a simple indicator like a heat stress index is needed to enable a quick, valid, and acceptable evaluation of underground climatic conditions on a regular basis. This can be explained by the unending quest to develop a "universal index," which has led to the proliferation of many proposed heat stress indices. Methods: The aim of this research study is to discuss the challenges in identifying and selecting an appropriate heat stress index for thermal planning and management purposes in underground mines. A method is proposed coupled to a defined strategy for selecting and recommending heat stress indices to be used in underground metal mines in the United States and worldwide based on a thermal comfort model. Results: The performance of current heat stress indices used in underground mines varies based on the climatic conditions and the level of activities. Therefore, carefully selecting or establishing an appropriate heat stress index is of paramount importance to ensure the safety, health, and increasing productivity of the underground workers. Conclusion: This method presents an important tool to assess and select the most appropriate index for certain climatic conditions to protect the underground workers from heat-related illnesses. Although complex, the method presents results that are easy to interpret and understand than any of the currently available evaluation methods.

Design Analysis of Ride Comfort- and Driving Safety-control Strategies for the Continuously Controlled Semi-active Suspension Systems (연속 가변식 반능동형 현가시스템의 승차감 및 주행안전성 제어기 설계 해석)

  • 허승진;황성호;박기홍
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.1
    • /
    • pp.17-23
    • /
    • 2004
  • The semi-active suspension system is getting widely adopted in passenger vehicles for its ability to improve ride comfort over the passive suspension system while not degrading driving safety. A key to the success is to develop practical controllers that yield performance enhancement over the passive damper under various driving conditions. To this end, several control strategies have been studied and evaluated in this research in consideration of practical aspects such as nonlinearity and dynamics of the damper. From simulation results. it has been observed that, with the proposed control schemes, ride comfort can be significantly upgraded while suppressing degradation of driving safety.

Evaluation of Speed Limit of Tilting Trains Including Passenger's Comfort in Conventional Line (틸팅특성과 승차감을 고려한 틸팅열차의 곡선부 제한속도 평가)

  • Eum Ki-Young;Um Ju-Hwan;Yeo In-Ho;You Young-Hwa
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.927-934
    • /
    • 2004
  • For the purpose of speed-up of conventional lines with many curves, the introduction and operation of tilting train is under process. Those are Joong-Ang, Jang-Hang and Ho-nam lines etc. Tilting trains can run a curve section faster than existing trains without a significant violation of passenger's comfort and enable to reduce operating time in the lines with many curves. In this study, the trains speeds are evaluated, based on the alignment of conventional line, criteria for passenger's comfort and investigated field conditions of the sections where the curves exist. Decision on whether the alignment(transition line) needs to be modified or not is also made. Relative efficiency on curve sections of tilting train to existing trains is approximately $50\%$ in average.

  • PDF

A Study on the Optimization of the Alignment Considering the Ride Comfort in the Case of the Superimposition of Vertical and Horizontal Curves (종곡선/평면곡선 경합 시 승차감을 고려한 선형최적화에 관한 연구)

  • Um, Ju-Hwan;Yang, Sin-Chu;Choi, Il-Yoon
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1943-1950
    • /
    • 2010
  • Superimposition of horizontal and vertical curves may hamper the ride comfort and the running stability of train and largely affect the maintenance cost. However, in many cases, it's not easy to make a track plan because of the fixed points (bridge, tunnel, turnout, catenary system, etc.) to be avoided due to the geographic conditions or to be passed for utilization of existing structures. In this study, when the horizontal and vertical curves are superimposed, in order to optimize the horizontal curve in aspect of the ride comfort, the object function $P_{CT}$ was developed and verified by vehicle dynamic analysis. Also, the solution algorithm for simplified evaluation method was presented.

  • PDF