• Title/Summary/Keyword: Combustion heat

Search Result 1,725, Processing Time 0.029 seconds

A Development of General Purpose Program NUFLEX for the Analysis of Heat/Fluid Flow (범용 열/유체 유동해석 프로그램 NUFLEX의 개발)

  • Hur N.;Won C.-S.;Son G.;Ryou H.-S.;Shin D.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.53-59
    • /
    • 2004
  • A general purpose program NUFLEX for the analysis of 3-D heat/fluid flow in complex geometry with pre/post processor have been developed, which consists of a flow solver based on FVM and a dedicated pre/post processor. The program employs a general non-orthogonal grid system and solve laminar and turbulent (lows with standard and RNG $\kappa-\epsilon$ turbulence models. NUFLEX is capable of analysing two-phase flow with topologically complex interface, turbulent diffusion combustion, solidification problems and magnetic flow. For the purpose of verification of the program and testing the applicability, several practical problems are solved and compared with the available data. Comparison of the NUFLEX results with that by the STAR-CD program has been also made for the same flow configuration and grid structure.

  • PDF

An Experimental Study on the Effects of the Automotive Cooling Performance by Cooling Airflow rate (II) (냉각 공기량이 자동차 냉각성능에 미치는 영향에 관한 실험적 연구(II))

  • Kim, J.H.;Lee, H.C.;Lee, M.H.;Park, J.N.;Cha, K.O.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.940-945
    • /
    • 2001
  • Gasoline engine manufacturers are currently considering designs that will result in low combustion air temperature for improvement of fuel consumption and emission levels. There are a variety of cooling systems that can be used to accomplish this goal. Cooling is therefore normally achieved through a balance of ram and fan action. This paper studies the various systems and compare the cooling performance for several conditions, based on a automotive engine. An experimental analysis was developed to predict the interaction of the fan system and the heat exchangers of the engine cooling system. The local temperature induced by the fan on the cooling system is measured. These experimental result were accomplished using airflow management techniques.

  • PDF

Estimation of Greenhouse Gas and Environmental Assessment in Co-generation Plant (열병합발전소의 온실가스 배출량 산정 및 환경성 평가)

  • Shin, Choon-Hwan;Park, Do-Hyun
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.2035-2044
    • /
    • 2014
  • Taking sample processes from the combined heat and power plant in Busan Fashion Color Industry Complex, the characteristics and amounts of greenhouse gas (GHGs) emissions were analysed and calculated, respectively. Based on the results, environmental assessment was evaluated for recent 3 years. The amounts of GHG emissions from 2011 to 2013 were estimated at 182,750, 184,384 and 190,250 $Ton.CO_2eq/year$, respectively. GHG emissions from stationary combustion sources were found to be more than 99 % of the total emissions. Also, the overall eco-efficiency indicator for environmental assessment was more than 1, suggesting that these results would be beneficial for GHG emissions allowance allocations.

The Use of methanol in Diesel Engines (디이젤기관에 있어서 매타놀의 사용)

  • ;Yoo, Byung Chul
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 1979
  • Methanol was examined as supplemental fuel for open chamber type and pre-combustion chamber type diesel engine. Pre-determined quantities of diesel oil were injected as ordinary diesel engines and methanol was added at inlet pipe using venturi, nozzel and and float chamber for the rest of the charge. In this mode of operation, addition of methanol reduced inlet and exhaust temperature. Inlet air quantities were essentially unchanged in spite of lower inlet temperature. Exhaust smoke was significantly reduced At light load when both diesel oil and methanol were introduced with small quantities, specific heat consumption was considerably increased. However, with the increase of the quantity of methanol or diesel oil, specific heat consumption was improved. With sufficient quantities of diesel oil enough to produce the power above 3/4 load, addition of methanol showed better thermal economy.

Fabrication and Performance Test of MEMS Catalytic Combustors Using Photosensitive Glass Wafer (감광유리를 이용한 MEMS 촉매 연소기의 제작 및 성능 평가)

  • Jin, Jung-Kun;Kwon, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.3
    • /
    • pp.237-242
    • /
    • 2009
  • MEMS catalytic combustors were fabricated to use in micro-power sources as a heat source. The combustor was fabricated by photolithography and anisotropic wet etching of photosensitive glass wafers. Two different catalyst loading methods were used to complete the fabrication of the combustors. For thin film type, the $Al_2O_3$ was washcoated on the surface of the combustion chamber as a catalyst support, and for packed-bed type, ceramic foam was inserted after Pt was coated. The volume of the combustors was 1.8 $cm^3$ and 16W of heat was generated using the fabricated combustors with hydrogen. The energy density of combustor was about 8.9 W/$cm^3$.

Stabilizing Mechanism for Methane Rich-Lean Flame (메탄 과농-희박 예혼합화염의 안정화 메커니즘)

  • Lee, Won-Nam;Seo, Dong-Kyu
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.19-24
    • /
    • 2002
  • Recent studies of a triple flame suggested that the presence of triple point (triple line in this planar configuration) could explain the mechanisms of stable fuel-lean premixed flames with equivalence ratio lower than the flammability limit. In the present study, for better understanding of the stability mechanisms of fuel rich-lean premixed flames, the fuel-rich flames were replaced with hot coils that will provide heat flux into the fuel-lean flames. It is found that the fuel-lean premixed flames could be stabilized without any triple point (triple line): however, the equivalence ratio limit for stable fuel-lean flame in this case is higher than that of the present work with the presence of fuel-rich flames. These results demonstrate that heat flux coming from fuel-rich flames should be considered in order to properly understand the roll of a triple flame for stable fuel rich-lean flames.

  • PDF

An application of general-purpose computer program in heat transfer and fluid flow to combustion process (열.유체 일반적 컴퓨터 프로그램의 연소과정 연구에의 응용)

  • 이재헌
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.1-6
    • /
    • 1984
  • 복잡한 연소과정의 예측을 위한 이론적인 연구는 Gosman, Spalding, Patankar등의 수치해석방 법을 이용하여 진행된 것들이 많다. 현재 이분야에 응용되는 일반적인 Program으로는 Boundary Layer Type의 방정식을 이용한 One-Dimensional Program (GENMIX 4, Revised GENMIX) 등이 있으나 Parabolic Type이므로 주방향에 수직된 방향으로 동일한 값이 2개 이상 존재할 수 있는 Elliptic현상을 설명하기에는 어려움이 있다. 그러므로 비록 기억용량(Computation Storage) 및 계산시간(Running Time)에 불리한 점이 있기는 하나 Elliptic상황을 해석해야만 할 경우가 있다. 본 해설은 Patankar의 Elliptic "SIMPLE" Program을 연소 해석과정에 이용되는 방법을 간단한 연소과정의 예로서 설명하는 것으로 연소과정의 연구보다도 Program의 응용성에 중점을 두었다. 따라서 실제의 물리적인 연소 mechanism에서 많은 가정을 도입하여 문제를 단순화 시켰으며 실제의 연소문제에 충분한 접근을 위해서는 turbulence-modeling과 radiation heat flux가 본 해설에 덧붙여져서 논의되어야 한다. 논의되어야 한다.

  • PDF

A Study on the Fire Safety Performance of Interior Surface Materials in a Building (건축물의 실내건축 재료에 관한 화재안전성 연구)

  • Seo, Su-Eun;Shin, Seung-Woo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.275-290
    • /
    • 2013
  • The main cause of building fire fatalities occur in the combustible material heat, smoke and toxic gases are. Building interior decoration, etc., especially as much of the harmful substances generated during combustion, and, used in domestic architecture wallpaper, ceiling, and other plastics, built-in foam insulation also analyzed recognition of fire hazards approach to test the conkalrorimiteo test, choedaeyeolbangchulryul through, chongbal heat, mass loss rate, generates carbon monoxide gas hazard ratio tests, analysis and evaluation rigid foam index testing the toxicity of hazardous material generated by performing a gas clean up and assess the material test results, the minimum order to provide data to quantify the risk of fire. Ensure fire safety of building materials, composite materials in order to test the various risk factors could be considered organic to the introduction of testing and evaluation is needed urgently.

  • PDF

Ventilation Effects on Smoke Behavior in Rescue Station for Tunnel Fires (철도터널 화재시 구난역 내의 연기거동에 미치는 배연효과에 관한 수치연구)

  • Jang, Won-Cheol;Kim, Dong-Woon;Ryou, Hong-Sun;Lee, Seong-Hyuk
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2130-2138
    • /
    • 2008
  • The present study investigates the ventilation effects on smoke spreading characteristics in railway tunnels with the rescue stations. Experiments were carried out for n-heptane pool fires with a square length 4 cm at different fire locations, and the heat release rates (HRR) were obtained by the measurement of burning rates. In addition, using the commercial code (FLUENT), the present article presents numerical results for smoke behavior in railway tunnels with rescue station, and it uses the MVHS (Modified Volumetric Heat Source) model for estimation of combustion products resulting from the fire source determined from the HRR measurement. As a result, it is found that smoke propagation is prevented successfully by the fire doors located inside the cross-passages and especially, the smoke behavior in the accident tunnel can be controlled through the ventilation system because of substantial change in smoke flow direction in the cross-passages.

  • PDF

Analysis of Thermodynamic Design Data for Cooling of Double -Effect Absorption System of Solar Energy using LiBr - water and Ethylene Glycol Mixture (흡수액으로 에틸렌글리콜이 혼합되고 태양열을 이용한 이중효용 흡수식 시스템의 냉방 특성해석)

  • Won, Seung-Ho;Park, Sang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.45-54
    • /
    • 2003
  • For cooling of double effect absorption heat pump system of solar heating source, analysis of thermodynamic design data has been done to find the property of Libr-water + ethylene Glycol mixture for working fluid by computer simulation. Derived thermodynamic design data, enthalpy based coefficient of performance and flow ratio for possible combinations of operating temperature for water - LiBr and Ethylene Glycol mixture ($H_2O$ : CHO ratio 10:1 by mole) by computer simulation are done. The obtained results, COP and mass flow ratio of the water - lithium bromide - ethylene glycol system, are compared with data for the water-Libr pair solution.