• Title/Summary/Keyword: Combustion Field

Search Result 537, Processing Time 0.023 seconds

Numerical Study of Thermal Choking Process in a Model SCRamjet Combustor (모델 스크램제트 연소기 내의 열적 질식 과정 수치 연구)

  • Lee, B.R.;Moon, G.W.;Jeung, I.S.;Choi, J.Y.
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.83-91
    • /
    • 2000
  • A numerical study was carried out to investigate the 'unstart' process of thermally-choked combustion in model scramjet engines. The combustion mechanism of supersonic combustor will be compared with the experimental results obtained from the T3 free-piston shock tunnel at ANU (Australian National University) and the high enthalpy supersonic wind tunnel at UT (University of Tokyo). For the numerical simulation of supersonic combustion. multi-species Navier-Stokes equations were considered. and detailed chemistry reaction mechanism of $H_2$-Air were adopted. The governing equations were solved by Roe's FDS method and LU-SGS method with MUSCL scheme. In this study. it is found that the thermal choking process could result from excessive heat release due to combustion. In detail, sufficient heat release could be generated at local region of very high temperature increased by reflection of shock waves or vortex sheets. Accordingly the flow of downstream of the combustor fell to subsonic field propagated upstream along the combustor. Sometimes the subsonic flow field propagated into isolator could generate precombustion shock waves in the isolator.

  • PDF

Experimental Study on the Characteristics of Pressure Fluctuation in the Combustion Chamber with Branch Tube (분기관을 가진 연소 챔버 내 압력변동 특성에 관한 실험적 연구)

  • Park, Jang-Hee;Lee, Dae-Keun;Shin, Hyun-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.552-558
    • /
    • 2009
  • An experimental study using the combustor with branch tube was conducted in order to model the industry combustor with FGR (flue gas recirculation) system and to study a thermo-acoustic instability generated by a branch tube. The branch tube is a structure used to modify a system geometry and then to change its pressure field, and the thermo-acoustic instability, usually occurs in a confined geometry, can result in serious problems on industrial combustors. Thus understanding of the instability created by modifying geometry of combustor is necessary to design and operate combustor with FGR system. Pressure fluctuation in the combustion chamber was observed according to diameter and length of branch and it was compared with the solution of 1-D wave equation. It was found that branch tube affects the pressure field in the combustion chamber, and the pressure fluctuation in the combustion chamber was reduced to almost zero when phase difference between an incipient wave in the combustion chamber and a reflected wave in the branch tube is $\pi$ at the branch point. Also, the reduction of pressure fluctuation is irrespective of the installed height of branch tube if it is below $h^*=0.9$ in the close-open tube and open-open tube.

Reactive Fields Analysis of End-Burning Hybrid Combustor Using Tangential Oxidizer Injectors with Various Momentum Ratio (접선형 산화제 주입기의 운동량비에 따른 End-Burning 하이브리드 연소기의 연소유동장 해석)

  • Min, Moon-Ki;Kim, Soo-Jong;Kim, Jin-Kon;Moon, Hee-Jang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.2
    • /
    • pp.37-46
    • /
    • 2007
  • In this study, combustion fields of the end-burning hybrid combustor with tangential oxidizer injectors are examined. Momentum ratio of oxidizer is used as a main parameter to analyse the combustion efficiency with temperature, pressure, swirl velocity and mixture fraction field. It was found that as momentum ratio decreases the overall combustion efficiency is enhanced with the pressure field being insensitive to momentum ratio keeping quasi-uniform distribution. Irrespective to the momentum ratio, annular hot region commonly occurred in the upper combustion chamber where this phenomenon was left for a future improvement to be followed.

Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers (보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법)

  • Jung, Jae-Jin;Song, Jung-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

The Influence of Magnetic Field on Diffusion Flames: Role of Magnetic Field On/Off Frequency and Duty Ratio (자기장 분포가 확산화염의 연소특성에 미치는 영향: 자기장 On/Off 주기와 Duty Ratio의 역할)

  • Lee, Won-Nam;Bae, Seung-Man
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.1
    • /
    • pp.58-65
    • /
    • 2012
  • The influence of magnetic field on propane and acetylene diffusion flames have been experimentally investigated using an electromagnetic system. Periodically induced magnetic field having various frequencies and duty ratios was established in square wave form. The maximum intensity and gradient of magnetic field were 1.3 T and 0.27 T/mm, respectively. The width of a propane flame was reduced up to 4.5% and the brightness was enhanced up to 25% when the magnetic field was induced. The soot emission from an acetylene flame was ceased when magnetic field was induced. The alteration of flow field, which is due to the paramagnetic characteristics of oxygen molecule, is most likely to be responsible for the change in flame size and brightness. The effect of magnetic field on diffusion flames, which competes with the gravitational effect, was more apparent from a smaller size flame. The magnetic field effect, therefore, could be important under microgravity conditions. Since the time required to alter the flow field must be finite, the magnetic field effect is likely to be less significant for a periodically oscillating magnetic field at a high frequency or having a small duty ratio.

Investigation on the Turbulent Swirling Flow Field within the Combustion Chamber of a Gun-Type Gas Burner (Gun식 가스버너의 연소실내 난류 선회유동장 고찰)

  • Kim, Jang-Kweon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.9
    • /
    • pp.666-673
    • /
    • 2009
  • The turbulent swirling flow field characteristics of a gun-type gas burner with a combustion chamber were investigated under the cold flow condition. The velocities and turbulent quantities were measured by hot-wire anemometer system with an X-type probe. The turbulent swirling flow field in the edge of a jet seems to cause a recirculation flow from downstream to upstream due to the unbalance of static pressure between a main jet flow and a chamber wall. Moreover, because the recirculation flow seems to expand the main jet flow to the radial and to shorten it to the axial, the turbulent swirling flow field with a chamber increases a radial momentum but decreases an axial as compared with the case without a chamber from the range of about X/R=1.5. As a result, these phenomena can be seen through all mean velocities, turbulent kinetic energy and turbulent shear stresses. All physical quantities obtained around the slits, however, show the similar magnitude and profiles as the case without a chamber within the range of about X/R=1.0.

Development of Wound Rotor Synchronous Motor for Belt-Driven e-Assist System

  • Lee, Geun-Ho;Lee, Heon-Hyeong;Wang, Qi
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.487-493
    • /
    • 2013
  • The automotive industry is showing widespread interest in belt-driven electric motor-assisted (e-Assist) systems. A belt-driven assist system (BAS) starts and assists the combustion engine in place of the conventional generator. In this study, a water-cooled wound rotor synchronous motor (WRSM) for the e-Assist system was designed and analyzed. The performance of the WRSM was compared with that of an interior permanent magnet synchronous motor (IPMSM). The WRSM efficiency can be improved for the BAS by adjusting the field flux at high speeds. The field current map to obtain the maximum efficiency based on the speed and torque was developed. To control the field flux via field current control in the WRSM, a general H-bridge circuit was added to the WRSM inverter to get the rapid current response in the high-speed region; the characteristics were compared with the chopper circuit. A WRSM developed for the belt-driven e-Assist system and a prototype 115 V power electronic converter to drive the WRSM were tested with a 900 cc combustion engine. The test results showed that the WRSM-type e-Assist system had good characteristics and could successfully start and assist the 900 cc combustion engine.

Effect of Magnetic Field on Negative DC Corona Discharge (부극성 직류 코로나 방전에 미치는 자계의 영향)

  • Park, J.Y.;Kim, I.K.;Jung, J.G.;Kim, G.H.;Kim, J.D.;Koh, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2308-2310
    • /
    • 1999
  • The effect of magnetic field on NOx removal characteristics from a combustion flue gas has been experimentally investigated for a DC corona discharge reactor with a multipoint plate geometry in our Lab. Combustion flue gas removal efficiency of this type was much higher than that of the other types. In this paper, needle-plate geometry discharge system with applied magnetic field at a right angle to the electric field was made. Input power source was used negative DC. The corona discharge characteristics for this system was investigated and compared with the corona characteristics for the corona discharge system without magnetic field.

  • PDF

CFD STUDY ON THE COMBUSTION CHAMBER OF AN OXY-FUEL FGR BOILER FOR $CO_2$ CAPTURING (순산소 재순환 연소를 채택한 $CO_2$ 회수형 보일러 연소실에 대한 수치해석)

  • Ahn, J.;Kim, H.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.329-334
    • /
    • 2009
  • An oxy-fuel boiler has been developed to capture $CO_2$ from the exhaust gas. FGR (flue gas recirculation) is adopted to be compliant with the retrofit scenario. Numerical simulations have been performed to study the detailed physics inside the combustion chamber of the boiler. The temperature field obtained from the simulation agrees with the flame image from the experiment. The FGR combustion yields similar heat transfer characteristics with the conventional air combustion while the flame is formed further downstream in case of the FGR combustion.

  • PDF

Study on Characteristics of Spray Combustion for Various Operation Conditions in a Gas Turbine Combustor (가스터빈 연소기 내 운전조건 변화에 따른 분무연소 특성 연구)

  • Cho, S.P.;Kim, H.Y.;Park, S.
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.3-10
    • /
    • 2002
  • In this work, numerical parametric studies on spray combustion have been conducted. In simulation of turbulence, RNG ${\kappa}-{\varepsilon}model$ is adopted. Initial spray distribution is specified by Rosin-Rammler distribution function. Eddy break-up model is adopted as a combustion model. The parameters considered are inlet air temperature, swirl number, and SMD. With higher inlet air temperature, the axial velocities are increased and penetration of primary jet is stronger than that of lower inlet air temperature and temperature at the exit of combustor is more uniform. Combustion efficiency is improved with high inlet air temperature. The effect of swirl number on flow field is not significant. It affect only recirculation zone. So temperature at upstream of combustor is influenced. Combustion efficiency deteriorate as SMD of fuel spray increase.

  • PDF