• 제목/요약/키워드: Combustion Fan

검색결과 52건 처리시간 0.022초

가스 스월버너의 공연비 제어에 관한 연구 (Study on the control of fuel-air ratio ofgas swirl burner)

  • 김인규;김영수;김양호;김경수;김지원
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.129-138
    • /
    • 1999
  • In this paper, our main issue is that establishing the control procedure of continuous gas flow rate according to combustion fan RPM. For this, first, we decide the optimum operating condition of gas swirl burner through analysis of combustion characteristics - thermal efficiency, combustion efficiency and exhaust gases such as CO, $CO_{2}$, $O_{2}$, $NO_{x}$ and THC. Second, fuel gas flow rate of gas valve is decided with considering excess air ratio and combustion fan RPM is decided by the target of combustion air flow rate. Finally, experimental operating equation is acquired by regression for gas valve and combustion fan. This equation is the control equation of continuous gas flow rate and always gas flow rate is decided by combustion fan operating RPM.

  • PDF

석유 팬 히터의 연소실 주변 열전달 특성 (Heat transfer characteristics around a circular combustion chamber of kerosene fan heater)

  • 김장권
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.551-561
    • /
    • 1998
  • This paper was studied to understand the characteristics of heat transfer coefficients and surface temperature distributions around a circular combustion chamber within the heat-intercept duct of kerosene fan heater. The experiment was carried out in the heat-intercept duct of kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of 240 mm * 240 mm * 1200 mm. The purpose of this paper was to obtain the basic data related with normal combustion for new design from conventional kerosene fan heater, and to investigate the effect of surface temperature, local and mean heat transfer coefficients versus flow-rate of convection axial fan according to the variations of heat release conditions from kerosene fan heater during normal combustion. Consequently it was found that (i) the revolution of convection axial fan during combustion had a smaller value than that of non-combustion because of the thermal resistance due to the high temperature in the heat-intercept duct, (ii) the pressure ratio P$_{2}$/P$_{1}$ had a comparatively constant value of 0.844 according to the revolution increase of turbo fan and the heating performance of kerosene fan heater had a range of 1,494 ~ 3,852 kcal/hr, (iii) the local heat transfer coefficient around a circular combustion chamber had a comparatively larger scale in the range of 315 deg. < .theta. < 45 deg. than that in the range of 90 deg. < .theta. < 270 deg. as a result of heat transfer difference between front and back of a circular combustion chamber, and (iv) the mean heat transfer coefficient around a circular combustion chamber increased linearly like a H$_{m}$=95.196Q+104.019 in condition of high heat release according to the increase of flow-rate of axial fan.n.

전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선 (Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD)

  • 김민철;손병현;이재정;박흥석
    • 한국산학기술학회논문지
    • /
    • 제22권6호
    • /
    • pp.460-468
    • /
    • 2021
  • 본 연구는 multi fan 방식의 "공랭식 연소설비"의 공정관리상의 문제점을 single F.D. fan 으로 대체하여 개선시키기 위해 CFD 진행하였고, 연소로 내 유동조건 변화를 분석하여 문제점을 확인하였다. 이를 개선하기 위해 연소공기 주입구조를 변경하였고, 구조 변화에 따른 연소효율 개선을 수치해석으로 평가하였다. 또한 실제 연소설비에 수치해석결과를 반영하여 구조개선을 한 후 개선 전·후의 연소효율을 실험적으로 측정하였다. 먼저 기존 Single F.D fan 이 적용된 연소설비에 대한 수치해석을 통해, 2개의 유로로 공급되는 연소공기가 각 유로의 마찰력 차이와 압력의 변화로 인해 연소로 내에서 공급비율이 불규칙하게 되어 선회방식의 연소조건을 위한 축 형태의 난류형성이 어려움을 확인하였다. 이를 개선하기 위해서 연소로에 주입하는 공기 공급 방식을 두 가지로 나누어 수치해석을 하였다. 첫 번째 방식은 연소공기를 외벽에서 180 ~ 360° 회전 후 예열된 연소공기가 주입되는 구조에 대하여 검토하였고, 두 번째는 연소로 내에는 선회할 수 있는 베인(vane) 구조를 적용하여 연소로 밖에서 1차 열교환 후 연소로 내부에 접선방향으로 연소공기가 주입되는 구조에 대하여 검토하였다. 그 결과, single F.D. fan을 가진 공랭식 연소로에 선회방식으로 공기를 주입할 경우, 연소로 외벽의 냉각과 연소로 내부의 완전혼합 유지를 위해 이중 냉각벽을 가지는 덕트 구조를 적용하는 것이 연소조건을 최적화하는데 바람직한 것으로 나타났으며, 실제 운영중인 설비에 적용하여 개선 전·후의 연소효율을 비교한 결과 연소효율이 개선되는 것을 확인할 수 있었다.

초음파 수첨가 연소에 의한 석유 홴 히터의 배기가스 특성 고찰 (An Investigation of Combustion Emission Characteristics of Kerosene Fan Heater with Addition of Water Droplets by Ultrasonic Atomizer)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제3권3호
    • /
    • pp.44-53
    • /
    • 1999
  • This study is concerned with the emission characteristics of kerosene fan heater, which is burned with kerosene and water droplets simultaneously in the burner, in order to prohibit the emissions of harmful exhaust gas and reduce smell caused by incomplete combustion, and the addition of water droplets to the conventional kerosene fan heater was performed by ultrasonic atomizer. For the investigation of this study, the measurement of exhaust gas components and exhaust gas temperature was carried out by using an automatic combustion gas analyser and $NO_x$ analyser, and the measurement of consumption weight of oil and water was obtained by using electric digital balance. Consequently, according as the water percent weight ratio of about $21{\sim}23%$ was supplied for this study, it was found that the combustion-generated $NO_x$ and CO emissions were reduced very largely, but the emissions of $O_2\;and\;CO_2$ and the temperature of exhaust gas were not changed.

  • PDF

석유 홴 히터의 난방 능력 고찰 (Investigation of Heating Performance of Kerosene Fan Heater)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제1권1호
    • /
    • pp.51-60
    • /
    • 1997
  • In this paper, we investigated the heating performance and the basic characteristics required for normal combustion of kerosene fan heater. And also the iso-velocity contours and the iso-temperature contours of hot gas discharged from the exit of kerosene fan heater were analyzed. The experiment was carried out with kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of $240mm{\times}240mm{\times}1200mm$. The purpose of this paper was to obtain the basic data for new design from conventional kerosene fan heater. Consequently it was found that (i) the pressure ratio $P_2/P_1$ had a comparatively constant value of 0.844 according to the increase of the revolution of turbo fan, (ii) the primary excess air ratio had a range of $0.84{\sim}1.11$ during normal combustion, and (iii) the heating performance of kerosene fan heater had a range of $1,494{\sim}3,852kcal/hr$.

  • PDF

미분탄 순산소 연소 운전 모드 전환 과정에 대한 Pilot 규모 설비에서의 실험적 연구 (An Experimental Study on Mode Switching from Air-firing to Oxy-firing in Pilot-scale Combustion Systems)

  • 최종균;나익환;이재욱;채태영;양원;김영주;김종안;서상일
    • 한국연소학회지
    • /
    • 제16권3호
    • /
    • pp.12-20
    • /
    • 2011
  • Oxy-coal combustion for $CO_2$ capture in coal power plants entails a mode switching from air-firing to oxyfiring. In this study, procedure of the mode switching was investigated and discussed through experiments in pilot scale facilities: (1) a 0.3 $MW_{th}$ furnace with a vertical single burner and a FGR(Flue Gas Recirculation) system (2) a 1 $MW_{th}$ furnace with horizontal 4 burners and a FGR system. Principle of the mode switching was established and performed with control of FD fan, FGR fan, ID fan and oxygen flow rates. We have found that equivalence ratio in the oxy-firing mode should be increased more than that in the air-firing to achieve stable mode switching. Control of FD, ID and FGR fans should be performed carefully in the mode switching, in the sense of complete combustion and flame attachment. Moisture contents in the ash and the flue gas recycled to the primary oxidizer stream should be removed to prevent condensation, corrosion and duct clogging.

에너지 절감형 전기 유류 겸용 온풍기 개발 (Development of Electrical and Oil Heater for Energy Saving)

  • 정성원;김동건;공상호
    • 한국기계가공학회지
    • /
    • 제10권5호
    • /
    • pp.38-43
    • /
    • 2011
  • This study was carried out to evaluate the structural stability of hybrid type fan heater. The evaluation of structural safety of hybrid fan heater was conducted by using Ansys Workbench and CFX-11 under the design condition. The hybrid fan heater was operated by heat transfer for heat source supplied from electric heater and combustion gas. According to result of structural analysis, the maximum equivalent stress of hybrid fan heater was 150MPa when the temperature of heat transfer fluids was $150^{\circ}C$. It was found that the hybrid fan was structurally safe because the value of maximum equivalent stress was smaller than that of yield stress of the material.

냉각 팬의 설계에 의한 유동저항에 관한 연구 (Study on Flow Resistance by the Design of Cooling Fan)

  • 조재웅
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.41-47
    • /
    • 2011
  • In this study, the structural analysis of cooling fan is combined with 3-D flow analysis by using CFD on fluid domain. The smoothly cooling flow with optimum design of cooling parts is essential at automotive combustion engine. The fan shape is modeled with three kinds of shape by varying the radius of the fan blade. By the results of analysis, the flow at Model I is more uniform than Model II or III. And the displacement at Model I is less than Model II or III. As the flow resistance of cooling fan at Model I decreases more than Model II or III, the efficiency becomes better.

습식 배연탈황 시스템의 효율 향상을 위한 전산해석 (Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas)

  • 황우현;이경옥
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권2호
    • /
    • pp.161-171
    • /
    • 2014
  • 본 논문에서는 CFDRC 사의 상용 CFD 소프트웨어인 CFD-ACE+로 전산유체역학 기법을 적용하여 수치 해석을 수행하여 배연탈황 설비에서 Induced Draft Fan(I.D.Fan) 출구부터 Booster Up Fan(B.U.Fan) 입구까지 난류 유동장과 연소 유동 문제를 모사하여 배기가스 계통 설비의 유동 특성을 해석하였다. 배기가스가 I.D.Fan 출구 ~ B.U.Fan 입구 구간을 적정속도로 균일하게 유동하여 B.U.Fan로 균일하게 유입되도록 하며 압력손실이 적게 발생하도록 설계기준 보일러 부하와 최대연속 정격유량의 보일러 부하에서 이 구간의 안내깃을 검토하였다. 검토한 결과에 대해 CFD 해석을 수행하여 I.D.Fan 출구에서 안내깃을 제거하고 B.U.Fan 입구 전에 안내깃을 보강할 수 있도록 설계를 변경하였다. 배기가스 계통에 변경된 설계를 적용하여 수치모사한 결과에서 배연탈황 설비 내부의 배기가스 압력손실이 줄어들고 유속과 유선이 균일하게 유동할 수 있어 배연탈황 시스템의 효율이 향상한 것을 확인하였다.

가솔린 직접분사식 고압 슬릿 노즐의 팬형 분무 특성 고찰 (Fan-shaped Spray Characteristics of High Pressure Slit Nozzle in a Gasoline Direct Injection Engine)

  • 송범근;김종민;강신재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2239-2244
    • /
    • 2003
  • A new stratified charge combustion system has been introduced and developed for GDI engines. Before this new GDI system, the stratified mixture was formed by a high pressure swirl injector. But, the special feature of new system is employed of a thin fan-shaped fuel spray formed by a slit type nozzle. Also, this system has been adopted a shell-shaped piston cavity. We made high pressure gasoline injection system and investigated the fan-shaped spray characteristics such as spray tip penetration, spray angle, SMD and velocities of droplets using PDPA(Phase Doppler Particle Analyzer) system and spray visualization system to obtain the concept of the new design and the fundamental data for the next generation GDI system. The experiment was performed at the injection pressures of 5 and 9MPa under the atmospheric condition.

  • PDF