• Title/Summary/Keyword: Combustion Control

Search Result 900, Processing Time 0.025 seconds

Effects of Surface Defect Distribution of $SiO_x(x{\le}2)$ Plates on Chemical Quenching ($SiO_x(x{\le}2)$ 플레이트의 표면 결함 분포가 화학 소염에 미치는 영향)

  • Kim, Kyu-Tae;Kwon, Se-Jin
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.328-336
    • /
    • 2005
  • Effects of surface defect distribution on flame instability during flame-surface interaction are experimentally investigated. To examine the chemical quenching phenomenon, we prepared thermally grown silicon oxide plates with well-defined defect density. Ion implantation was used to control the number of defects, i.e. oxygen vacancies. In an attempt to preferentially remove the oxygen atoms from silicon dioxide surface, argon ions with low energy level from 3keV to 5keV were irradiated at the incident angle of $60^{\circ}C$. Compositional and structural modification of $SiO_2$ induced by low-energy $Ar^+$ ion irradiation has been characterized by Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS). The analysis shows that as the ion energy increases, the number of structural defect also increases and non-stoichiometric condition of $SiO_x(x{\le}2)$ plates is enhanced. From the quenching distance measurements, we found out that when the surface temperature is under $300^{\circ}C$, the quenching distance decreases on account of reduced heat loss; as the surface temperature increases over $300^{\circ}C$, however, quenching distance increases despite reduced heat loss effect. Such aberrant behavior is caused by heterogeneous chemical reaction between active radicals and surface defect sites. The higher defect density, the larger quenching distance. This results means that chemical quenching is governed by radical adsorption and can be parameterized by the oxygen vacancy density on the surface.

  • PDF

Development of Non-CO2 Greenhouse Gas Emission Factors for the B-C Oil Fired Boiler Power Plants (B-C유 화력발전소 보일러의 Non-CO2 온실가스 배출계수 개발 연구)

  • Lee, See-Hyung;Kim, Jin-Su;Kim, Ok-Hun;Lee, Jeong-Woo;Lee, Seong-Ho;Jeon, Eui-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • The power plants are one of the GHG major source among the sectors of fossil fuel combustion, therefore information of its emission factors is very essential to the establishing control strategies for the greenhouse gas emissions. The $CH_4$ and $N_2O$ concentration from power plants were measured using GC-FID and GC-ECD. The results showed that $CH_4$ emission factor was 0.33 kg/TJ and $N_2O$ emission factor was 0.88 kg/TJ. The $CH_4$ and $N_2O$ emission factors developed in this study were compared with those for IPCC default value and other countries emission factors. The results showed that $CH_4$ emission factor was lower than IPCC default value and Finnish emission factor, but higher than Japanese emission factor. $N_2O$ emission factor was higher Japanese emission factor and IPCC default emission factor however lower than Finnish emission factor. More research is needed on our own emission factors of various energy-consuming facilities in order to stand on a higher position in international negotiations regarding the treaties on climate changes.

Analysis of Unsteady Combustion Performance in Solid Rocket Motor with Pintle (핀틀을 장착한 고체추진기관의 비정상 연소 성능 분석)

  • Ki, Taeseok;Ha, Dongsung;Jin, Jungkun;Lee, Hosung;Yoon, Hyungull
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.68-75
    • /
    • 2015
  • In this paper, unsteady characteristics of pressure in solid rocket motor were analyzed by using response of pintle actuation, pressure and thrust data from ground test. Pressure and thrust in solid rocket motor can be controlled in real time by varying nozzle throat area with pintle, installed in the valve. Unsteady characteristics of pressure can be observed in this system occurred by various reasons. Two critical reasons, error of pintle actuation and ablation of center tube, are found and effects of each reason can be analyzed individually by re-prediction of pressure with response of pintle actuation and analyzing thrust to pressure ratio.

Development of a System for Measuring the Velocity of a Waste-gas Produced from a Melting Process (용해공정에서 배출되는 폐가스 유속 측정 시스템 개발)

  • Park, Jin Soo;Jung, Jae Hak;Sung, Su Whan
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.340-347
    • /
    • 2008
  • In the case of a melting process, the velocity of waste-gas has been measured to produce the melt of an equal condition and to analyze the combustion situation of the fuel which was inputted in a furnace. Recently, there are many kinds of measuring equipments of gas-velocity on the market. But, the waste-gas produced from a melting process is high temperature, the slow speed and includes much dust. Existent measuring equipments are not suited to these conditions. Therefore, we made the measuring equipment of new method which is enough detailed to react on the slow speed and sustains in high temperature. As shown in the result of field test, the manufactured measuring equipment is so sensitive as to react on a small change of velocity and senses temperature change rapidly, we expect that this equipment helps in temperature control of a melting furnace.

Adsorption characteristics of the sericite and diatomite for ammonia gas (견운모와 규조토에 대한 암모니아 기체의 흡착특성)

  • Lee, Suseung;Kim, Jinsoo;Yun, Chang Yeon;Yi, Jongheop
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.175-181
    • /
    • 2006
  • The feasibility of the use of porous fossil diatoms for indoor air pollution control was investigated via the characterization of physical and chemical properties. The fossil diatoms were observed by SEM(Scanning Electron Microscope). Diatomite had well-distributed pores below 5 nm and relatively large surface area compare to sericite. However, no porosity in sericite was found. Results showed that diatomite had better performance than sericite in respect to porosity and large surface area. But diatomite which is thermally treated at $950^{\circ}C$ has no porosity and low surface area because of combustion of fossil diatoms or calcination of inorganic oxide at high temperature, and has poor adsorption capability of ammonia gas. In conclusion, porous diatomite has relatively high performance to adsorb noxious chemical compounds, such as ammonia gas and VOCs.

  • PDF

Responses of Various Biomarkers in Common Carp (Cyprinus carpio) Exposed to Benzo[k]fluoranthene

  • Kim, Woo-Keun;Kim, Ja-Hyun;Yeom, Dong-Hyuk;Lee, Sung-Kyu
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.3
    • /
    • pp.331-337
    • /
    • 2008
  • Polycyclic aromatic hydrocarbons (PAHs) derived from leakage of fossil fuels and incomplete combustion of organic materials have been considered as harmful contaminants in environments. This study evaluated the effect of benzo[k]fluoranthene (BkF), one of the PAHs, using the multiple biomarkers and applied the integration model with those biomarker responses. After 10 days of the exposure at the measured concentrations of BkF (6, 25, and 45 ${\mu}g\;L^{-1}$), the changes of the four biomarkers, that is, 7-ethoxyresorufin-O-deethylase (EROD), DNA single-strand breaks (Comet), acetylcholinesterase (AChE) and vitellogenin (VTG) in the common carp (Cyprinus carpio) were observed. The standardized values of four biomarker responses were computed and integrated as star plots, representing Integrated Biomarker Respnse (IBR) values. DNA damage was induced in a dose-dependent manner, and increased significantly compared with that in the control. EROD and VTG levels were significantly elevated at low concentrations of BkF. On the other hand, AChE activities were not altered by BkF. IBR values increased as the exposure concentrations increased. Thus, the metabolic, endocrine and genetic changes of the biomarker responses in the common carp exposed to BkF should be considered in the case of the ecological risk assessment of the BkF in fish and it can be used as a biomonitoring tool in aquatic ecosystems. In addition, star plots can be used as a useful analysis tool in multibiomarker integration approach.

Effects of various densities and velocities on gaseous hydrocarbon fuel on near nozzle flow field under different laminar coflow diffusion flames

  • Ngorn, Thou;Jang, Sehyun;Yun, Seok Hun;Park, Seol Hyeon;Lee, Joo Hee;Chung, Suk Ho;Choi, Jae Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.2
    • /
    • pp.102-106
    • /
    • 2016
  • An experimental study on the flow characteristics under various laminar coflow diffusion flames was conducted with a particular focus on the buoyancy force exerted from gaseous hydrocarbon fuels. Methane ($CH_4$), ethylene ($C_2H_4$), and n-butane ($C_4H_{10}$) were used as the fuels. A coflow burner and the Schlieren imaging technique were used to observe the flow field of each fuel near the nozzle exit as well as the flow characteristics in the flames. The results show that a vortex with a density heavier than air appeared in n-butane near the nozzle exit with a strong negative buoyancy on the fuel steam. As the Reynolds number increased through the control of the fuel velocity of the n-butane flame, the vortices were greater and the vortex tips were moved up from the nozzle exit. In addition, the heated nozzle affected the flow fields of the fuel steam near the nozzle exit.

An experimental study on development of water mist fire-fighting systems for Ro-Ro spaces (Ro-Ro 구역용 미분무 소화설비의 개발을 위한 실험적 연구)

  • Kwark, Ji-Hyun;Kim, Young-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.946-952
    • /
    • 2013
  • Large scale fire tests were conducted to develop water mist nozzles as a component of fixed water- based fire fighting systems for Ro-Ro spaces and special category spaces. Fire scenarios for this system consist of two cases which are for cargo fire in a simulated truck and for passenger vehicle fire, and each case has 3 different tests according to the position between fixed water mist nozzles and fire source. Every experiment proceeded for 30 minutes and acceptance criteria were based on gas temperature, fuel package's damage and ignition of targets. This study primarily dealt with the experimental results of cargo fire and focused on fire suppression capability in accordance with discharge pressure, flow rate and flow characteristics like swirl and penetration of the developed water mist nozzles. It appeared that low pressure water mist nozzles with about 40 L/min were able to control fire occurred in Ro-Ro spaces.

A Study on the Pressure Increment of Fuel Pump for GDI Engines Considering Leakage Flows (누설특성을 고려한 GDI 엔진용 연료펌프의 고압생성 증진에 관한 연구)

  • Na, Byung-Chul;Kim, Byoung-Soo;Choi, Suk-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.785-791
    • /
    • 2000
  • GDI (Gasoline Direct Injection) engines are considered as one of the candidates for next generation engines of passenger cars, which reduce exhaust emissions and fuel consumption. In GOI engines, a high-pressure gasoline supply system is required to directly inject the fuel to combustion chambers. Because of low lubricity of gasoline fuel, the clearance between a plunger and a barrel in GDI fuel pumps is too wide to achieve smooth hydrodynamic lubrication. Thus, it is difficult to generate high-pressure condition in GDI fuel pump since large amount of leakage flow occurs between the plunger and the barrel In this study, an optimum plunger design is presented to minimize leakage in the aspect of flow control. This paper analyzes leakage flow characteristics in the clearance to improve pumping performance of GDI fuel pumps. Effects of groove in the plunger are studied according to variations of depth and width. Evaluations of pumping performance are determined by the amount of pressure drop in the leakage path assuming a constant leakage flows. Both of turbulence and incompressible models are introduced in CFD (Computational Fluid Dynamics) analysis. Design parameters have been introduced to minimize leakage in limited space, and a methodological study on geometrical optimization has been conducted. As results of CFD analysis in various geometrical cases, optimum groove depths have been found to generate maximum sealing effects on gasoline fuel between the plunger and the barrel. This procedure offers a methodological way of an enhancement of plunger design for high-pressure GDI fuel pumps.

A Toxicity Evaluation for the Toxic Gases of Building Finish Materials (건축물 마감재료 연소가스에 의한 독성평가)

  • Cho, Nam-Wook;Cho, Dong-Ho;Oh, Eun-Ha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.129-140
    • /
    • 2012
  • Smoke toxicity is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice. This test result can be influenced by the health status of mice and test condition. In acute inhalation toxicity test of hazardous gas, no typical clinical findings and histopathologic abnormalities were observed. Tracheitis and bronchitis as well as acute lung inflammation around terminal bronchiole in some mouse of the highest dose group. Through this study, we established the method for inhalation toxicity test of hazardous gas as well as the SOP of inhalation toxicity test. However, in the future studies, the concentration control methods for inhalation technologies on hazardous gas will be needed to improve continuously and also further studies on other gas inhalation toxicity will be needed to conduct.