• 제목/요약/키워드: Combustible

검색결과 518건 처리시간 0.023초

가연성(可燃性) 물질(物質)의 중량(重量) 연소속도(燃燒速度) 측정(測定)에 관(關)한 실험적(實驗的) 연구(硏究) (An experimental study on measurement of combustion rate of combustible substances)

  • 박영조;한응교;김상욱;박원영
    • 한국안전학회지
    • /
    • 제2권1호
    • /
    • pp.11-16
    • /
    • 1987
  • A study was performed on combustion rates of three kinds of combustible substances under a few different combustion conditions. To measure the combustion rates by weight method, I contrived an apparatus using a sensitive load cell. The experimental results by the combustion tests of various combustible substances shows that the combustion circumstances, eg., air supply condition and the existence of flammable oil. And it is found that the time constant T in case of oil absence is smaller than that in case of oil existence, and the time constant T in case of enforced air-entrained condition is greater that in case of natural air-entrained condition.

  • PDF

LPG 가연성 혼합물에 대한 고형 금지제의 억제 효과 (Inhibitory Effect of Solid Inhibitors on LPG Combustible Mixtures)

  • Hamdan, M. A.;Yamin, J. A.;Dabbas, R. K.
    • 대한화학회지
    • /
    • 제54권3호
    • /
    • pp.295-299
    • /
    • 2010
  • 액화석유가스-공기 불꽃에 대한 2가지 열적 금지제(즉, 돌가루, 탄산칼슘)의 억제효과를 연구하였다. 이를 위해 이들 금지제를 가하기 전과 후 가연성 혼합물의 가연성 한도를 측정하여 조사하였다. 그 결과, 탄산칼슘이 돌가루에 비해 억제 효과가 우수하였다.

경량 폴리머 콘크리트의 난연성 및 동결융해 저항성 (Incombustibility and Freezing-Thawing Resistance of Lightweight Polymer Concrete)

  • 채경희;최예환;연규석;이윤수;주명기
    • 한국농공학회지
    • /
    • 제45권1호
    • /
    • pp.45-54
    • /
    • 2003
  • The effects of binder content and silica sand content on the durability characteristics of lightweight polymer concretes are examined. As a result, the flame lingering times using unsaturated polyester resin and non-combustible polyester resin were 60∼120 and 0∼4 seconds respectively, and the combustion lengths were 9∼11 mm and 0∼3 mm, respectively. Thus it is believed that the lightweight polymer concrete was incombustible and the light weight polymer concrete in which non-combustible material was added was perfectly non-combustible. The percent of original mass of lightweight polymer concrete, according to the freezing-thawing experiment, was below 0.3 %, which was much less than that of cement concrete. The pluse velocity, for the case of the binder content 28 %, showed the minimum decreasing rate for the lightweight polymer concrete with silica sand content of 50 %. The higher the binder content, the greater the durability. That is much higher than other material and believed that the freezing-thawing was suppressed by a low absorption.

연소시 생성된 CO가스의 고찰을 통한 인명피해 최소화 방안에 관한 연구 (A Study on the ways to minimize Casualties through a consideration of the CO gas generated during combustion)

  • 최만철;김병석
    • 대한안전경영과학회지
    • /
    • 제15권1호
    • /
    • pp.133-140
    • /
    • 2013
  • Recently developed a variety of architectural interior decoration according hwadoeme type of toxic gases generated during fire also are becoming diversified, resulting in fatal casualties occurred in the trend is also being increased. During a fire, toxic gas that is generated varies depending on the combustible material occurs. However, all combustible materials, including carbon, incomplete combustion of carbon monoxide which is generated in the most common toxic gases can be seen as one. Accordingly, in this study of organic solids that are generated in case of fire toxic gases, and briefly discuss the characteristics of the risks and, by far the most common Co gas for measures to prevent human casualties, seolbijeok, the temperature dependence, divided into four aspects of administrative daechaekdeung explained.

가연성 유해가스 처리를 위한 연소기 개발 (Development of Combustor for Combustible Hazardous Gas)

  • 전영남;채종성;김미환
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.479-485
    • /
    • 1996
  • Volatile organic compounds are air pollutants exhausting from industrial process, evaporation of solvent, and so on. Most of VOCs are the combustible gas of low calorific value as it is diluted by air. The systems burning such a hazardous gas need to increase enthalpy in order to increase flame stability. In this study an incinerator with reciprocating flow in the honeycomb ceramic has been used for the experiment of VOCs control. By the reciprocating flow system, the enthalpy of combustion gas is effectively regenerated into the enthalpy increases of the combustible gas through the honeycomb ceramic, which provides a heat storage. The position of the reaction zone is strongly dependent on the parameters of mixture velocity and time frequency. Flame front is changed to the point where burning velocity is coincided with burning velocity in the honeycomb ceramic. In this system it is important that flame front should be located symmetrically at the center of honeycomb ceramic for the purpose of increasing the reaction rate at one point. Peak temperature becomes higher with decreasing time frequency, at which the flow direction is regularly reversed.

  • PDF

화재시 생성된 유독가스로부터의 소방 안전관리 방안 연구(Co 가스 대책을 중심으로) (A Study on the Fire Safety Management measures from during a fire toxic gases generated (Focus to Co gas measures))

  • 김병석;장병집;최만철
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 추계학술대회
    • /
    • pp.55-66
    • /
    • 2011
  • Recently developed a variety of architectural interior decoration according hwadoeme type of toxic gases generated during fire also are becoming diversified, resulting in fatal casualties occurred in the trend is also being increased. During a fire, toxic gas that is generated varies depending on the combustible material occurs. However, all combustible materials, including carbon, incomplete combustion of carbon monoxide which is generated in the most common toxic gases can be seen as one. Accordingly, in this study of organic solids that are generated in case of fire toxic gases, and briefly discuss the characteristics of the risks and, by far the most common Co gas for measures to prevent human casualties, seolbijeok, the temperature dependence, divided into four aspects of administrative daechaekdeung explained.

  • PDF

고온 환경에서의 적외선 열화상 측정에 관한 연구 (Research on Measurement of Infrared Thermograpphy under High Temperature Condition)

  • 이준식;전재욱
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

A Study on the Prevention of Fire Korean in Waste Facilities

  • Jang-Oh Kim;Kyong-Jin Park
    • 한국산업융합학회 논문집
    • /
    • 제27권4_1호
    • /
    • pp.722-733
    • /
    • 2024
  • According to the National Fire Agency, there are 1,810 waste recycling facilities, 2,094 waste treatment facilities, and 223 waste minimization facilities in Korea. Waste fires are characterized by high severity and are prone to reignition, and it is difficult to timely detect them. Waste fires consequently demand many firefighters, equipment, and time to extinguish. Notwithstanding this reality, waste is excluded from the category of special combustible materials in the Act on Installation and Management of Firefighting Systems, 2021 (the Act). Therefore, this study proposes that special combustible materials, including waste, should be incorporated into the Act, that fire detectors and photoelectric smoke detectors should be installed to enable early detection of fires, and that the use of water and foaming agents as firefighting equipment should be enforced.

종량제봉투 내 폐자원에 대한 최적 처리방안 연구 (A Study on the Optimal Management Option of the Disposal of Resources Found in Standard Plastic Garbage Bags)

  • 박상준;김의용
    • 자원리싸이클링
    • /
    • 제23권5호
    • /
    • pp.44-54
    • /
    • 2014
  • 인천광역시에서 배출되는 종량제봉투 안에는 재활용 가능자원이 4.5% (알루미늄캔류 0.2%, 철캔류 2.5%, 유리류 1.8%), 에너지회수가 가능한 자원이 92.5% (종이류 23.0%, 플라스틱류 15.5%, 가연성 기타류 54.0%) 및 매립이 필요한 불연성 기타류가 3.0%로 분석되었다. 알루미늄캔류, 철캔류 및 유리류는 기존의 매립처리보다 재활용처리가 효과적이며, 종이류와 플라스틱류는 기존의 단순 소각처리보다 폐기물 고형원료 (SRF)로 만들어 에너지회수처리하는 편이 더 효과적이고, 가연성 기타류는 기존의 단순 소각처리가 재활용처리보다 효과적이다. 본 연구에서 제안한 폐자원별 처리방안을 적용하면 2,068,948 Million Btu의 에너지가 절감되고, 21,008 $MTCO_2E$의 온실가스가 저감되는 것으로 분석되었다. 총 에너지 절감량을 경제적 효과로 환산하면 연간 약 422억 원의 비용절감 효과가 있으며, 총 온실가스 저감량을 승용차의 이산화탄소 배출량으로 환산하면 연간 약 4,119대의 운행감축 효과가 있는 것으로 나타났다. 종량제봉투 내 가연성 물질의 저위발열량은 종이류 1,936 kcal/kg, 플라스틱류 5,079 kcal/kg, 가연성 기타류 2,462 kcal/kg로 분석되었다. 종이류와 플라스틱류를 적절하게 혼합한다면 SRF로 활용이 가능하고, 가연성 기타류는 저위발열량이 고형연료 기준을 충족시키지 못하고 구성성분들이 폐기물 고형연료로 사용하기엔 부적절하였다.

가연성 천연고분자 분체의 훈소에 관한 연구 (Smouldering Combustion of Combustible Natural Polymer Dust Layer)

  • 김홍
    • 한국안전학회지
    • /
    • 제5권1호
    • /
    • pp.7-18
    • /
    • 1990
  • This study measured the smouldering temperature of dust layer for various combustible natural polymer material by practical apparatus. The dust layer was either put on the preheated plate of constant temperature, or formed with cylinderical metal sleeve of various diameters and depths at room temperature and then heated up to a pre-determined smouldering temperature. Plots of arrival times versus smouldering temperature were made to compare the smouldering characteristics with kinds of dusts. The natural polymer material was divided into theree groups by characteristics of smouldering mechanism. This groups are cellulose group, lipide group and glucose group.

  • PDF