• Title/Summary/Keyword: Combined strength ratio

Search Result 209, Processing Time 0.024 seconds

Test study of precast SRC column under combined compression and shear loading

  • Chen, Yang;Zhu, Lanqi;Yang, Yong
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.265-275
    • /
    • 2022
  • A new type of precast steel reinforced concrete (PSRC) column was put forward in this paper. In order to study the static performance of PSRC column and hollow precast steel reinforced concrete (HPSRC) column subjected to combined compression and shear loading, a parametric test was carried out and effects of axial compression ratio, concrete strength and shear ratio on the mechanical behavior of composite PSRC column and HPSRC column were explored. In addition, the cracks development, load-span displacement relationship, strain distribution and shear bearing strength of column specimens were emphatically focused. Test results implied that shear failure of all specimens occurred during the test, and higher strength of cast-in-place concrete, smaller shear ratio and larger axial compression ratio could lead to greater shear resistance, but when the axial compression ratio was larger than 0.36, the shear capacity began to decrease gradually. Furthermore, truss-arch model for determining the shear strength of PSRC column and HPSRC column was proposed and the calculated results obtained from proposed method were verified to be valid.

Utimate strength analysis of cylindrical members of offshore structure subject to combined loads (조합하중을 받는 해양구조물 원통부재의 최동강도 해석)

  • 박치모
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.11-17
    • /
    • 1997
  • Simple and efficient way of nonlinear analysis considering elasto-plastic large deformation is introduced to calculate the strength of ring-stiffened cylinears subject to combined load of axial compression and lateral pressure. Parametric study gives various collapse modes according to the combination ratio of axial compression and lateral pressure, interaction between axial compression and lateral pressure and imperfection sensitivity of ultimate strength.

  • PDF

A Study on the Non-Destructive Testing Method on the Estimation of the Compressive Strength Concrete (콘크리트의 압축강도 추정을 위한 비파괴시험식에 관한 연구)

  • Kwon, Young-Jin;Oh, Sang-Kun;Kim, Moo-Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.1
    • /
    • pp.97-105
    • /
    • 1997
  • The major object of this study is to analyze and investigate experimentally the experimenal equation for the estimate of compressive strength of concrete. The results are as follows. The relation between maturity scaled logarithm and compressive strength of concrete can be expressed in liner equation which show an good correlation. And combined method using rebound number, pulse velocity and water cement ratio also show an excellent correlation. The equation by combined method is same as the conclusions.

  • PDF

Evaluation on Spalling Properties of Ultra High Strength Concrete with Combined Fiber (복합섬유를 혼입한 초고강도 콘크리트의 폭렬 특성 평가)

  • Son, Myung-Hak;Kim, Gyu-Yong;Min, Choong-Siek;Lee, Tae-Gyu;Koo, Kyung-Mo;Youn, Yong-Sang
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.209-210
    • /
    • 2011
  • This study is aimed to draw a optimum combined fiber mix condition to improve spalling resistance and flowability of ultra high-strength concrete. As a result, W/B 12.5% concrete specimens were prevented spalling with PE0.05+ PP0.1, PE0.05+NY0.1 and W/B 12.5% concrete specimens were prevented spalling with all of combined organic fiber mix condition. But There is no significant influence of steel fiber under 5% volume ratios to prevent spalling. In the scope of this study, we suggest that condition of optimum volume ratio PE0.05+NY0.1 is to improve spalling resistance, flowability and residual compressive strength.

  • PDF

Analysis of Static and Dynamic Characteristics of Reinforced Roadbed Materials (철도 강화노반재료의 정ㆍ동적 특성 분석)

  • 황선근;신민호;이성혁;이시한;최찬용
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.1
    • /
    • pp.34-41
    • /
    • 2000
  • The analysis of static and dynamic characteristics of reinforced roadbed materials was performed through model and laboratory tests. The strength characteristic of reinforced roadbed materials such as HMS-25 and soil were investigated through the unconfined axial compression test, the model soil box test and the combined resonant column and torsional shear test. The unconfined axial compression strength of HMS-25 shows a steady increasement in strength due to the chemical hardening reaction between HMS-25 and water. The result of model soil box test reveals that railroad roadbed of HMS-25 is better than that of soil in several aspects, such as, bearing capacity and settlement. The combined resonant column and torsional shear test result indicates that shear modulus of HMS-25 and soil increase with the power of 0.5 to the confining pressure and linear relationship to normalized shear modulus and damping ratio.

  • PDF

Properties of the Combined High Flowing Concrete by Mix Design Factors (병용계 고유동 콘크리트의 배합요인에 따른 특성)

  • Kwon Yeong Ho;Lee Hyun Ho;Lee Hwa Jin;Ha Jae Dam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.407-410
    • /
    • 2005
  • This research investigates experimentally an effect on the properties of the combined high flowing concrete by mix design factors. The purpose of this study is to determine the optimum mix proportion of the combined high flowing concrete having good flowability, viscosity, no-segregation and design strength(40.0MPa). For this purpose, trial mixings used belite cement+lime stone powder(LSP) are tested by mix design factors including water-cement ratio($47.9\~54.0\%$), fine aggregate volume ratio($41\~45\%$) and coarse aggregate volume ratio($41\~45\%$). As test results of this study, the optimum mix proportion for the combined high flowing concrete is as followings. Water-cement ratio $51.0\%$, fine aggregate volume ratio $43{\pm}1\%$ and coarse aggregate volume ratio $0.30{\pm}0.05m^3/m^3$ and replacement ratio of LSP $42.7\%$.

  • PDF

Effect of spiral reinforcement on flexural-shear-torsional seismic behavior of reinforced concrete circular bridge columns

  • Belarbi, Abdeldjelil;Prakash, Suriya;You, Young-Min
    • Structural Engineering and Mechanics
    • /
    • v.33 no.2
    • /
    • pp.137-158
    • /
    • 2009
  • This paper investigates the behavior of reinforced concrete (RC) circular columns under combined loading including torsion. The main variables considered in this study are the ratio of torsional moment to bending moment (T/M) and the level of detailing for moderate and high seismicity (low and high transverse reinforcement/spiral ratio). This paper presents the results of tests on seven columns subjected to cyclic bending and shear, cyclic torsion, and various levels of combined cyclic bending, shear, and torsion. Columns under combined loading were tested at T/M ratios of 0.2 and 0.4. These columns were reinforced with two spiral reinforcement ratios of 0.73% and 1.32%. Similarly, the columns subjected to pure torsion were tested with two spiral reinforcement ratios of 0.73% and 1.32%. This study examined the significance of proper detailing, and spiral reinforcement ratio and its effect on the torsional resistance under combined loading. The test results demonstrate that both the flexural and torsional capacities are decreased due to the effect of combined loading. Furthermore, they show a significant change in the failure mode and deformation characteristics depending on the spiral reinforcement ratio. The increase in spiral reinforcement ratio also led to significant improvement in strength and ductility.

Early Strength and Properties of EVA Powder Modified High Strength Concrete (EVA Powder 개질 고강도 콘크리트의 초기강도 및 수밀특성)

  • Kim, Young-Ik;Sung, Chan-Yong
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.123-127
    • /
    • 2005
  • EVA Powder modified high strength concretes were prepared by varying polymer/binder mass ratio with a constant water/binder mass ratio of 0.3. The effect of EVA powder on the slump, hydration heat, compressive and flexural strength, toughness and water absorption ratio was studied. In hydration heat test, temperature of hydration reaction displayed almost fixed level regardless of containing rate of EVA powder, but peak time of hydration reaction displayed late inclination as containing rate of powder increases. With the same water/binder mass ratio, the compressive strength and water absorption of EVA powder modified concretes decreased slightly when EVA powder was added and the flexural strength of EVA powder modified concretes rised slightly when EVA powder was added. Also, the toughness of the modified concretes can be improved markedly. The interpenetrating structure between the polymeric phase and cement hydrates formed at a $2{\sim}6%$(containing rate of EVA powder). The properties of the polymer modified concretes were influenced by the polymer film, cement hydrates and the combined structure between the organic and inorganic phases.

  • PDF

Yield strength estimation of X65 and X70 steel pipe with relatively low t/D ratio

  • Kim, Jungho;Kang, Soo-Chang;Kim, Jin-Kook;Song, Junho
    • Steel and Composite Structures
    • /
    • v.38 no.2
    • /
    • pp.151-164
    • /
    • 2021
  • During the pipe forming process, a steel plate undergoes inelastic behavior multiple times under a load condition repeating tension and compression in the circumferential direction. It derives local reduction or increase of yield strength within the thickness of steel pipes by the plastic hardening and Bauschinger effect. In this study, a combined hardening model is proposed to effectively predict variations of yield strength in the circumferential direction of API-X65 and X70 steel pipes with relatively low t/D ratio during the forming process, which is expected to experience accumulated plastic strain of 2~3%, the typical Lüder band range in a low-carbon steel. Cyclic tensile tests of API-X65 and X70 steels were performed, and the parameters of the proposed model for the steels were calibrated using the test results. Bending-flattening tests to simulate repeated tension and compression during pipe forming were followed for API-X65 and X70 steels, and the results were compared with those by the proposed model and Zou et al. (2016), in order to verify the process of material model calibration based on tension-compression cyclic test, and the accuracy of the proposed model. Finally, parametric analysis for the yield strength of the steel plate in the circumferential direction of UOE pipe was conducted to investigate the effects of t/D and expansion ratios after O-forming on the yield strength. The results confirmed that the model by Zou et al. (2016) underestimated the yield strength of steel pipe with relatively low t/D ratio, and the parametric analysis showed that the t/D and expansion ratio have a significant impact on the strength of steel pipe.

An Investigation on the Quality of High-Strength Shotcrete and the Long Term Durability using Combined Deterioration Test (고강도 숏크리트의 품질평가와 복합열화시험을 통한 장기내구성 검토)

  • Ma, Sang-Joon;Kim, Dong-Min;Choi, Jae-Seok;Ahn, Kyung-Chul;Kim, Sun-Myung;Ko, Jin-Kon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.906-915
    • /
    • 2006
  • In this study, Field test was performed using high-quality additions and accelerators to obtain the improvement of the strength on domestic shotcrete and quality test based on EFNARC was performed. In addition, Deterioration test that combined the Freezing-thawing and Carbonation was also performed in order to investigate a long-term durability of high-strength shotcrete. As a result of field test, a promotion ratio of early strength is $90\sim97%$ in case of using alkali-free accelerators. And a compressive strength of shotcrete using Micro-silica fume was $45.2\sim55.8MPa$ and the flexible strength was $5.01\sim6.66MPa$, so a promotion ratio of strength was $37\sim79%$, $17\sim61%$ respectively. It was showed that increment effect of strength by the Micro-silica fume replacement of $7.5\sim10%$ for cement mass was remarkable. It was also realized that application of Micro-silica fume to shotcrete reduced deterioration and improved a long-term durability of shotcrete.

  • PDF