• 제목/요약/키워드: Combined sewer

검색결과 147건 처리시간 0.031초

우수저류조의 형상과 도류벽 및 자갈채움에 따른 SS 제거효율 (SS Removal-rate Efficiency of Storm-water Detention Storage Tank Depending upon Length, Inside Training Wall and Gravel Filling)

  • 이종태;서홍준;서경아
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.655-667
    • /
    • 2009
  • An experimental study is performed on reducing the pollutants supplied by storm water through enhancing efficiency of SS from the detention storage tank where CSOs are kept temporarily before discharge to the receiving water system. SS removal efficiency is investigated in accordance with various conditions of the detention pond-such as its length, the existence of training wall, and the use of gravel filling. The removal efficiency is strongly affected by the detention pond's length until the critical falling distance of the suspended solids is reached. For cases where the tank has a length longer than this critical condition, the removal rate shows less sensitivity. To enhance the SS removal efficiency of tanks of shorter than the critical length, we studied alternative types of tank in which inside training walls are installed. The results showed improvement of 14 to 37% in removal efficiency in 2hours detention(2 training walls). The important factor in achieving a high SS removal rate is ensuring the critical length of the detention pond, but for the cases where the basin length cannot be guaranteed, baffles or a gravel filling scheme may be introduced to attain considerable efficiency. The results of studying and comparing different storage tank conditions show that, in terms of elimination efficiency, a storage tank with gravel filling and training walls > a storage tank with gravel filling > a storage tank with training walls > an empty tank. The experimental results should contribute to development of related further research, by empirically verifying the already assumed importance of critical falling distance, training walls, and gravel filling schemes.

도시지역 월류수에 의한 비점오염원의 유출 특성과 연계한 하천 영향 평가 (Impacts Assessments of River Linked with Runoff Characteristics of Non-Point Source by CSOs in Urban Area)

  • 김유성;고혁배;안상대;김원일;안원식
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.92-96
    • /
    • 2008
  • 최근에 이상기후로 인한 집중호우는 단시간의 높은 강우 강도의 발생을 증가시켜 재해 유발의 측면에서 뿐만 아니라 유역 내 비점오염원이 합류식 관거의 월류수인 CSOs(Combined Sewer Overflows)의 형태로 강우와 함께 유입되어 수질 및 환경을 오염시키는 문제점이 발생한다. 이에 따라 월류수의 유출특성에 대한 정량적인 분석을 통하여 유량 및 수질 등의 오염부하량에 대한 적절한 저감 방안이 요구되고 있는 실정이다. 이에 본 연구에서는 비점오염원의 농도가 상대적으로 높은 도시유역에 강우로 인한 월류수의 유출 특성 변화를 분석함과 동시에 월류수가 하천에 방류되었을 때의 하천에 미치는 영향 분석을 통하여 하천의 효율적인 수질 관리 방안을 제시하고자 한다. 경기도 구리시를 대상유역으로 선정하였으며, 도시 강우-유출 모델인 SWMM을 사용하여 유역의 유출량 및 월류수의 수질 모의를 수행하였으며, 유역의 최종 방류구에 비점오염 저감을 위해 설치된 저류지를 통해 하천으로 배출되는 유출수와의 연계는 미국 환경청에서 개발된 WASP 모델을 적용하여 왕숙천 본류에 대한 월류수 변화가 하천에 미치는 영향을 분석하였다. 저류지 설치 전 후의 하천에 월류수가 미치는 영향을 BOD 농도를 중심으로 비교 분석하였다. 분석 결과 저류지 설치 후 BOD 농도의 저감율은 설치 전 보다 최소 1.9%, 최대 81.2%의 저감 효과가 있는 것으로 분석되었다. 향후 신뢰도 높은 수질모의를 위해서는 월류수 발생시 월류수와 하천의 지속적인 모니터링을 통해 현장 여건을 반영할 수 있는 입력변수의 도출이 매우 중요한 것으로 나타났다.

  • PDF

분뇨수거량 평가방법 연구 : 서울시를 중심으로 (Prediction of Sludge's Volume Collected from Septic Tank Cleaning in Seoul)

  • 유기영;조인성
    • 유기물자원화
    • /
    • 제15권4호
    • /
    • pp.138-146
    • /
    • 2007
  • 서울시에는 아직도 생활하수와 빗물이 함께 흘러가는 합류식 하수관거지역이 많다. 이들 지역의 모든 건물들은 화장실 세정수로부터 고체상 물질을 분리해서 저장하는 정화조가 설치되어 있다. 정화조는 연 1회 이상 청소를 해야 하며 이 과정에서 분뇨가 수거된다. 수거분뇨는 처리시설이 필요로 하며, 과부족이 없는 처리시설을 확보하기 위해서는 장래에 발생할 분뇨수거량을 예측해야 한다. 본 연구에서는 그 분뇨수거량의 예측방법을 검토하였다. 여러 가지 예측인자 중 건물연면적이 가장 신뢰할 수 있었고, 수거분뇨는 처리 시설이 필요로 하며, 과부족이 없는 처리시설을 확보하기 위해서는 장래에 발생할 분뇨수거량을 예측해야 한다. 본 연구에서는 그 분뇨수거량의 예측방법을 검토하였다. 여러 가지 예측인자 중 건물연면적이 가장 신뢰할 수 있었고, 분뇨수거량이 꾸준하게 증가해서 2020년 서울시에서는 1일 13,149kL이 발생할 것으로 평가되었다. BOD의 변화도 예측이 가능하였다.

  • PDF

Vortex separator와 연속식 섬유사여과를 이용한 CSOs 처리연구 (A Study on Treatment of CSOs by Vortex Separator and Continuous Fiber-Filter System)

  • 이범준;나지훈;김진성;주재영;배윤선;정인호;박철휘
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.443-451
    • /
    • 2010
  • This study was conducted to confirm the CSOs characteristics, and to estimate treatment efficiency of CSO treatment process. Flowrate was average $53,500m^3$/d, maximum $58,100m^3$/d during dry season, but after rain-fall, the flowrate was increased more than twice that of the dry season. And, water pollution concentrations, such as $COD_{Cr}$, SS, $BOD_5$, TN and TP of after rain-fall, were also increased. Thus, for more efficient treatment of pollutants during rainy season, The vortex separator and continuous fiber filter devices were used. From the results on particle range, removal efficiency of particle was 99.7% at the particle size range of $40{\sim}100{\mu}m$ but decreased as 55-80% at the below $40{\mu}m$. The removal efficiencies of $COD_{Cr}$, SS, TN and TP were approx. 70, 60, 70 and 50, respectively during the dry season and approx. 50, 50, 8 and 18% during the rainy season. Also, when compared with the primary sediment basin, $COD_{Cr}$, SS, TN and TP removal efficiencies were high. especially, at the case of TN and TP, TN was more removed than TP because of higher conversion factor value. But we needed more study for the injection of a coagulants to get more stable treatment efficiency for soluble pollutants. Consequently, This process can be used for CSOs treatment as well as replace the primary sedimentation basin during the dry season.

LCA 기법을 활용한 합류식 하수도 월류수 사업의 잠재적 환경영향 저감효과 분석 (An Analysis of Potential Environmental Impact Reduction for Combined Sewer Overflow Project using a LCA Methodology)

  • 조현정;송장환;황용우;박지형
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.885-892
    • /
    • 2011
  • In this study, LCA(Life Cycle Assessment) on 'Saemangum CSO Project' was carried out to evaluate environmental impact which occurred during the construction and operation periods and the potential environmental impact reduction was analyzed by comparing production and reduction level of pollution loads. LCA was conducted out according to the procedure of ISO14040 which suggested Goal and Scope Definition, Life Cycle Inventory Analysis, Life Cycle Impact Assessment and Interpretation. In the Goal and Scope Definition, the functional unit was 1 m3 of CSO, the system boundary was construction and operation phases, and the operation period was 20 years. For the data collection and inventory analysis, input energies and materials from civil, architecture, mechanical and electric fields are collected from design sheet but the landscape architecture field is excepted. LCIA(Life Cycle Impact Assessment) was performed following the procedure of Eco-Labelling Type III under 6 categories which were resource depletion, eutrophication, global warming, ozone-layer destruction, and photochemical oxide formation. In the result of LCA, 83.4% of environmental impact occurred in the construction phase and 16.6% in the operation phase. Especially 78% of environmental impact occurred in civil works. The Global warming category showed the highest contribution level in the environmental impact categories. For the analysis on potential environmental impact reduction, the reduction and increased of environmental impact which occurred on construction and operation phases were compared. In the case of considering only the operation phase, the result of the comparison showed that 78% of environmental impact is reduced. On the other hand, when considering both the construction and operation phases, 50% of environmental impact is increase. Therefore, this study showed that eco-friendly material and construction method should be used for reduction of environmental impact during life cycle, and it is strongly necessary to develop technology and skills to reduce environmental impact such as renewable energies.

PC용 CAD를 이용한 단지기반시설 정보화 (Establishing Automated Mapping/Facilities Management System Using PC-CAD)

  • 이규석;안승만;탁형렬
    • 한국측량학회지
    • /
    • 제15권2호
    • /
    • pp.141-148
    • /
    • 1997
  • 지속적인 PC의 발전 및 이에 반비례한 가격의 하락, Windows 95. Windows N/T로 이어지는 PC운영체제의 확장은 소규모 단지의 경우 PC에서도 도시기반시설관리정보체계의 운영가능성을 신중히 모색케 하고 있다. 이와 같은 점을 고려하여 AutoCAD를 이용하여 한국토지공사의 단지기반시설 업무인 pipe-based도시기반시설-상수, 우수, 오수-및 도로의 도면정보와 속성정보를 PC상에서 동시에 관리할 수 있는 자료자동화 시스템을 구축하였고, 향후 구축 방향 및 문제점을 논하였다.

  • PDF

산림과 밭 지역 강우 유출수의 EMC 및 원단위 산정 (Determination of EMC and Unit Loading of Rainfall Runoff from Forestry-Crops Field)

  • 원철희;최용훈;서지연;김기철;신민환;최중대
    • 한국물환경학회지
    • /
    • 제25권4호
    • /
    • pp.615-623
    • /
    • 2009
  • The research of the determination of event mean concentration (EMC) was focussed combined sewer overflows and highway runoff in korea. But those of non-urban areas are few. In this study, EMC and unit loading on land use types in Nogok watershed were estimated by runoff loading of non-point source (NPS) on non-urban area. Two monitoring sites were equipped with an automatic velocity meter, flow meter, and water sampler. Monitoring was conducted at two monitering site during the rainy season. The results show that the EMC ranges in forest land use are 1.3~2.6 mg/L for BOD, 2.0~16.1 mg/L for SS, 0.1~2.1 mg/L for TN, and 0.12~0.49 mg/L for TP. The unit loading of NPS in this study was difficult to compare directly with that used conventionally because of the difference of field investigation. In near future, it needs to conduct more systematic and long-term research about NPS within the watershed. The results of this research can be used to estimate the total pollution load management system (TPLMS) program in korea.

Pulsed UV를 이용한 CSOs 소독시 반사체에 따른 처리효율 연구 (A Study of Treatment Efficiency of Reflectors for CSOs Disinfection by Pulsed UV)

  • 한종훈;허지용;김강욱;이준영;박원석;이종열;허남국
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권1호
    • /
    • pp.36-40
    • /
    • 2015
  • This study examined the disinfection in combined sewer overflows (CSOs) by pulsed ultraviolet (PUV). The reflectors (stainless steel. mirror, aluminium foil, aluminium (1050), aluminium (6061), aluminium (5052), and aluminium mirror) of PUV irradiation was performed in a 90 L stainless reactor at a constant temperature of $20^{\circ}C$ and an applied power of 4000 W. The reflection efficiency of reflectors were showed 1.00 (aluminium mirror) ~ 1.48 (aluminium foil) does. The case of a rough surface analysis using SEM showed high reflectance, was the case of a smooth surface and a low reflectivity. Pseudo first-order rate constant calculated results, has a higher reflectivity values were more than twice as high compared to the low reflectivity. Affected Total coliforms disinfection time, depending on the type of reflector is considered.

컴퓨터 시뮬레이션을 이용한 신 생물학적 고도처리 (병렬 고도처리) 공법 개발 (Developing a New BNR (Parallel BNR) Process by Computer Simulation)

  • 이병희;이용운
    • 상하수도학회지
    • /
    • 제16권6호
    • /
    • pp.670-678
    • /
    • 2002
  • Since Korean government imposed a stricter regulation on effluent T-N and T-P concentrations from wastewater treatment plant, a new process has to be developed to meet these rules and this process should remove T-N and T-P, economically, from weak wastewater that is typical for Korea's combined sewer system sewage. In this study, a computer simulator, BioWin from EnviroSim, Inc. was used. Three processes - A2/O, Modified Johannesburg, UCT- had been simulated under same operational conditions and a new process - Parallel BNR Process - had been developed based on these simulation results. The Parallel BNR process consists of two rows of reactors: One row has anaerobic and aerobic reactors in series, and the other row has RAS anoxic1 and RAS anoxic2 reactors in series. In order to ensure anaerobic state in anaerobic tank, a part of influent is fed to RAS anoxic1 tank in second row. This process had been simulated under same conditions of other three processes and the simulation results were compared. The results showed that three existing processes could not perform biological phosphorus removal when the average influent was fed at any operation temperatures. However, the Parallel BNR process was found that biological phosphorus removal could be performed when both design and average influent were fed at any operation temperatures. This process showed the T-N concentration in effluent had a maximum value of 15mg/L when design influent was fed at $13^{\circ}C$ and a minimum value of 14mg/L when average influent was fed at $20^{\circ}C$. Also, T-P concentrations had a maximum value of 1.3mg/L when average influent was fed at $20^{\circ}C$ and a minimum value of 1.1mg/L when design influent was fed at $13^{\circ}C$. Based on these results, we found that this process can remove nitrogen and phosphorus biologically under any operational conditions.

오염부하량을 고려한 월류수 처리시설 규모 결정 (Determination of CSOs Treatment Capacity considering the Pollution Load)

  • 김중훈;유도근;이의훈
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3270-3278
    • /
    • 2014
  • 도시배수시스템에서는 초기유출수(first flush)에 의한 하천오염이 심각한 문제로 대두되고 있다. 이는 강우발생시 강우에 의해 도시지역의 비점오염원들에 의해서 오염물이 하수관거로 유입되고 한정된 하수처리장의 용량으로는 제대로 처리하지 못하는 월류수에 의해 하천의 수질이 악화되기 때문이다. 대상유역으로 선정한 경기도 구리시 돌다리분구는 합류식 관거로 이루어져 있어 우기시 강우에 의한 월류가 발생할 확률이 높다. 월류에 의해 인근 왕숙천의 수질오염이 가중될 우려가 있어 적절한 처리시설의 설치가 필요하였다. 기존의 CSOs 설계에서는 강우의 최대치를 이용하여 설계가 연구되었다. 그러나, 강우의 최대치를 이용한 설계는 시설의 과다계획으로 이어져 많은 예산낭비를 초래할 수 있으며, 처리시설의 적정규모를 산정하지 못한다. 본 연구에서는 강우특성을 분석하여 매개변수들을 산정하고 이에 따른 유출분석을 실시하였다. 또한 위험도를 고려한 강우-유출분석을 이용하여 유출량을 계산하였다. 유출량을 포함한 유출특성에 의해 월류특성을 분석하였다. 왕숙천 BOD 오염농도를 기준으로 설계하기 위해 하수처리장 용량별 처리시설 요구효율을 산정하였으며 현재 하수처리장의 하수처리를 고려하여 간이 CSOs 처리시설의 효율을 71.48%로 하여 설계하였다.