• Title/Summary/Keyword: Combined sewer

Search Result 147, Processing Time 0.034 seconds

Study on the influence of sewer network simplification on urban inundation modelling results (하수관망의 간소화가 도시침수 모의에 미치는 영향 분석에 관한 연구)

  • Lee, Seung-Soo;Pakdimanivong, Mary;Jung, Kwan-Sue;Kim, Yeonsu
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.4
    • /
    • pp.347-354
    • /
    • 2018
  • In urban areas, runoff flow is drained through sewer networks as well as surface areas. Therefore, it is very important to consider sewer networks as a component of hydrological drainage processes when conducting urban inundation modelling. However, most researchers who have implemented urban inundation/flood modelling, instinctively simplified the sewer networks without the appropriate criteria. In this research, a 1D-2D fully coupled urban inundation model is applied to estimate the influence of sewer network simplification on urban inundation modelling based on the dendritic network classification. The one-dimensional (1D) sewerage system analysis model, which was introduced by Lee et al. (2017), is used to simulate inlet and overflow phenomena by interacting with surface flow. Two-dimensional (2D) unstructured meshes are also applied to simulate surface flow and are combined with the 1D sewerage analysis model. Sewer network pipes are simplified based on the dendritic network classification method, namely the second and third order, and all cases of pipes are conducted as a control group. Each classified network case, including a control group, is evaluated through their application to the 27 July 2011 extreme rainfall event, which caused severe inundation damages in the Sadang area in Seoul, South Korea. All cases are compared together regarding inundation area, inflow discharge and overflow discharge. Finally, relevant criterion for the simplification method is recommended.

Effects of Disinfectant Concentration, pH, Temperature, Ammonia, and Suspended Solids on the Chlorine Disinfection of Combined Sewer Overflow (소독제 농도, pH, 온도, 암모니아 농도, 부유물질이 강우 월류수 염소 소독에 미치는 영향)

  • Kim, Sang-Hyoun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.685-690
    • /
    • 2014
  • The treatment of combined sewer overflow (CSO) is one of potential concerns in domestic wastewater treatment in Korea due to the pre-announce of CSO regulations. This work investigated the effects of disinfectant (NaOCl) concentration (0.11 to 4.0 mg $Cl_2/L$), pH (6.5 to 8.0), temperature (15 to $25^{\circ}C$), ammonia (10 to 41 mg N/L), and suspended solids (91 to 271 mg SS/L) on the chlorine disinfection of CSO. The effect of NaOCl concentration on the pseudo-$1^{st}$ order reaction rate for total coliform inactivation was described well with a saturation-type model with the half-velocity constant of 1.212 mg/L. The total coliform inactivation reaction rate decreased with SS and pH, and increased with temperature. Ammonia in the examined range did not affect the disinfection kinetics. A chlorine contact tank with the injection chlorine level of 1 mg $Cl_2/L$ and the hydraulic retention time of 1.25 min is estimated to reduce total coliform from $1{\times}10^5MPN/mL$ to 1,000 MPN/mL at 271 mg SS/L, $15^{\circ}C$, and pH 8.0. Chlorine would be a proper option for the disinfection of CSO.

Evaluation of Pilot scale Coagulation system Design for CSOs treatment (CSOs 처리를 위한 실증규모 응집침전시스템의 설계평가)

  • Lee, Seung-Chul;Ha, Sung-Ryong
    • Journal of Wetlands Research
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • A pilot scale coagulation system, which has a function of physicochemical treatment, was developed to treat Combined sewer overflows(CSOs). This coagulation system requires evaluation of optimum design factors whether it has reflected those of lab scale system, moreover, the pilot scale system can be evaluated differently according to the characteristics of influent CSOs even though it has reflected lab scale's design factors. We conducted an experiment using lab scale system that could treat $1m^3$ of CSOs in a day, and also pilot-scale system with $100m^3/day$ CSOs flowed into the Cheongju sewage treatment plant. Therefore the aim of this study is to evaluate a hydraulic similarity between the design factors of pilot scale and those of lab scale coagulation system, and to evaluate feasibility of the coagulation system for the CSOs treatment with optimum operation conditions. From the result of pilot-test, we drew the optimum operation factors of in line mixer and flocculator having similarities with those of lab scale system as well as the optimum coagulant dose. Finally we confirmed that the coagulation system has feasibility to treat the CSOs with high removal efficiency.

A Case Study on Cost-Benefit Analysis of the Septic Tank and Exclusive Sewage Pipe Line in Designing the large Building at Combined Sewer District (합류식 하수도 지역에 대형 건축물 설계시 정화조 및 전용오수관로의 비용편익분석 사례연구)

  • Oh, Hyun-Taek;Kim, Sung-Tai;Lim, Byung-In;Kang, Byong-Jun;Park, Kyoo-Hong
    • Journal of Digital Convergence
    • /
    • v.17 no.6
    • /
    • pp.169-175
    • /
    • 2019
  • The aim of this study is to examine the relative economic benefits between the septic tank and exclusive sewage pipe line in designing the large building at combined sewer districts. With the case study of Lotte World Tower Building, we analyze a cost-benefit between two alternatives. The research results showed 2 years of payback period, about ₩6.17 billion of NPV, and 1.93 of B/C ratio for installing the exclusive sewage pipe line in comparison with septic tank. This results provide useful guidelines for policy establishment of the septic tank closure and for plausibility of installing exclusive sewage pipe line when constructing a large building. In the future, it will be necessary to consider additional cost-benefit analysis including burden charge borne by causers, the burden of management responsibility with a exclusive sewage pipe line, and the economic benefits of reducing odor.

Optimum Flow and Pollution Load Monitoring Time of Combined Sewers of Urban Watersheds during Dry Weather (비강우시 도시 합류식 하수도의 오염부하 산정을 위한 최적관측시간 산정연구)

  • Choi, Yong-Hun;Won, Chul-Hee;Park, Woon-Ji;Seo, Ji-Yeon;Shin, Min-Hwan;Lee, Chan-Ki;Choi, Joong-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.3
    • /
    • pp.9-14
    • /
    • 2009
  • Flow and pollution load were monitored at 2 combined sewer outlets (C-1 and C-2) of urban watersheds during dry weather from September, 2004 to April, 2006 for 20 months. The objectives were to investigate the diurnal variation of flow and pollutant load and to find the proper sampling time that could measure representative flow and pollutant load. Pollution load closed to the average daily load at C-1 could be measured at 00:00 hour and by the mean of 15:00 and 18:00 hour measures, and 15:00 and 21:00 hour measures, respectively. In addition at C-2, it was 21:00 hour and the mean of 15:00 and 18:00 hour measures. This study concluded that arbitrary sampling of flow and water quality could cause large errors in the estimation of urban pollution load and recommended that urban combined sewers should be monitored when flow and water quality showed daily average and concentration.

Urban Flood Simulation Considering Building and Sewer Lines (건물 및 우수 배제를 고려한 시가지 범람해석)

  • Kang, Sang-Hyeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3B
    • /
    • pp.213-219
    • /
    • 2009
  • In densely urban areas, features such as the sewer system, buildings and river banks have an effect on flow dynamics and flood propagation, and will therefore be accounted for in the model set-up. While two-dimensional (2D) flood models of urban areas are at the forefront of current research into flood inundation mechanisms, they are however constrained by inadequate parameters of topography, and insufficient and inaccurate data. In this study, an urban flood model (overland flow, 2D urban flood flow and sewer flow) was combined and applied at Samcheok city which was damaged by inundation in 2002, in order to simulate inundation depth. The influence of buildings and pumping capacity was also analyzed to estimate the inundated depth in the study area. As a result, it was found that urban inundated depth are affected by pumping capacity directly and it increased about 20-30 cm on most of the modeled area with a building share rate of 0.2-0.6 per unit grid.

Modeling of Discharge Characteristics of Combined Sewer Overflows(CSOs) from a Small Urban Watershed in Daejeon City (대전광역시 소유역에서 합류식 하수관거 월류수(CSOs)의 배출특성 모델링)

  • Kim, Jeong-Kon;Ko, Ick-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.654-660
    • /
    • 2006
  • This study investigated the discharge characteristics of combined sewer overflows(CSOs) at a small watershed located in the Ojeong-cheon area of the Daejeon-cheon, Daejeon City. The long-term variations of discharges, water quality, and SS loads from 2001 to 2004 were simulated using SWMM. The simulation results indicated that suspended solid(SS) loads during the rainy seasons(July${\sim}$August) were highest throughout the whole year, but not substantially higher than those during the dry seasons. This result is due to the fact that contaminants do not buildup significantly because of frequent rainfall events during the wet seasons. It was estimated that about 9.3% of SS was discharged to the receiving body the during dry seasons while 90.7% during the rainy seasons. Further analysis showed that during the wet seasons SS loads discharged at the site as CSOs and at the wastewater treatment plant without treatment were 38% and 62%, respectively.

A Study on the Risk - based Local Normal CSOs Curve Designs (위험도 기반 지역별 정규 CSOs 곡선 설계에 관한 연구)

  • Jo Deok-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.7 s.168
    • /
    • pp.575-581
    • /
    • 2006
  • This paper presents a systematic approach for the economical design of stormwater quality control systems. For the design of runoff quality control system (RQCS), the rainfall-runoff process requires the local rainfall data recorded continuously. In this study the rainfall probability distribution is assumed to follow an exponential decay function. Applying the exponential decay function, the normalized curves are derived to explain the non-exceedance probability distributions. The optimal curves for the determination of the RQCS size are derived based on the overflow risk. Comparison of the optimal capture volume and peak runoff rate to those computed by an urban rainfall-runoff model(ILLUDAS) demonstrates that the optimal CSOs(Combined Sewer Overflows) curves derived in this study can be utilized for the design of stormwater quality control systems in Korea avoiding an excessive computational effort based on over flow risks.

Criteria for calculation of CSO volume and frequency using rainfall-runoff model (우수유출 모형을 이용한 합류식하수관로시스템의 월류량, 월류빈도 산정 기준 결정 연구)

  • Lee, Gunyoung;Na, Yongun;Ryu, Jaena;Oh, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.313-324
    • /
    • 2013
  • It is widely known that untreated Combined Sewer Overflows (CSOs) that directly discharged from receiving water have a negative impact. Recent concerns on the CSO problem have produced several large scale constructions of treatment facilities, but the facilities are normally designed under empirical design criteria. In this study, several criteria for defining CSOs (e.g. determination of effective rainfall, sampling time, minimum duration of data used for rainfall-runoff simulation and so on) were investigated. Then this study suggested a standard methodology for the CSO calculation and support formalized standard on the design criteria for CSO facilities. Criteria decided for an effective rainfall was over 0.5 mm of total rainfall depth and at least 4 hours should be exist between two different events. An Antecedent dry weather period prior to storm event to satisfy the effective rainfall criteria was over 3 days. Sampling time for the rainfall-runoff model simulation was suggested as 1 hour. A duration of long-term simulation CSO overflow and frequency calculation should be at least recent 10 year data. A Management plan for the CSOs should be established under a phase-in of the plan. That should reflect site-specific conditions of different catchments, and formalized criteria for defining CSOs should be used to examine the management plans.

Analysis of Hydrodynamic Separators for Combined Sewer Overflows and Stromwater Runoff Control (합류식 하수관거 월류수 및 우수관거 유출수의 수리동력학적 오염부하저감장치의 분석)

  • Lee, Soo Young;Oh, Ji Hyun;Ryu, Seong Ho;Kwon, Bong Ki;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.117-124
    • /
    • 2005
  • Appropriate removal of pollutants from combined sewer overflows(CSOs) and stormwater runoff is of primary concern to watershed managers trying to meet water quality standards even under a wet weather condition. Harmful substances associated with particles besides TSS and BOD are subjected to removal prior to discharge into the natural waters. Effectiveness of five major hydrodynamic separation technologies, Vortechs, Downstream Defender including Storm King for CSOs control, CDS, Stormceptor, and IHS, were evaluated in this study. There is not sufficient information for accurate evaluation of the removal efficiency for the pollutants from the stormwater runoff and CSOs. Based upon limited engineering data, however, all technologies were found to be effective in separation of heavy particles and floating solids. Technologies utilizing screens seem to have advantage in the treatment capacity than the other technologies relied fully on hydrodynamic behavior. The IHS system seems to have a strong potential in application for control of CSOs because of unique hydrodynamic behavior as well as a flexibility in opening size of the screens. Size of the particulate matter in the CSOs and stormwater runoff is found to be the most important parameter in selection of the type of the hydrodynamic separators. There exists an upper limit in the solids removal efficiency of a hydrodynamic separator, which is strongly dependent upon the particle size distribution of the CSOs and stormwater runoff.