• Title/Summary/Keyword: Combined heat and power system (CHP)

Search Result 57, Processing Time 0.019 seconds

A Study on Generating efficiency of the Double Acting Stirling Engine/Generator (양방향 스털링엔진/발전기의 효율 특성 연구)

  • PARK, SEONGJE;KO, JUNSEOK;HONG, YONGJU;KIM, HYOBONG;YEOM, HANKIL;IN, SEHWAN
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.1
    • /
    • pp.114-120
    • /
    • 2016
  • This paper describes generating efficiency characteristics of the double acting Stirling engine/generator for domestic small-scale CHP (Combined Heat and Power) system. In small distributed generation applications, Stirling engine has competition from fuel cell, microturbine and etc. In order to be economical in the applications, a long life with minimum maintenance is generally required. Free piston Stirling engine (FPSE) has no crank and rotating parts to generate lateral forces and require lubrication. Double acting Stirling engine/generator has one displacer and two power piston which are supported by flexure springs. Two power pistons oscillate with symmetric displacement and are connected with moving magnet type linear generators for power generation from PV work. In experiments, 1 kW class double acting free piston Stirling engine/generator is fabricated and tested. Heat is supplied to hot end of engine by the combustion of natural gas and converted to electric power by linear generators which are assembled with power pistons. The electric parameters such as voltage, current and phase are measured with for variable flow rate of fuel gas. Especially, generating efficiency of FPSE is measured with three different measurement methods. Generating efficiency of the double acting Stirling engine/alternator is about 24%.

High Efficiency Fuel Cell System with Air Amplifier using Waste Heat (배열이용 공기증폭기를 활용한 고효율 연료전지 시스템)

  • Jun, Jaeho;Choi, Youngjae;Jun, Joonghwan;Kim, Seontae;Kim, Seongwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.72.1-72.1
    • /
    • 2010
  • 지금까지 연료전지 시스템의 효율을 극대화시키기 위한 기술들이 개발되어 왔는데, 대표적인 방법은 CHP(Combined Heat & power)와 FCT(Fuel cell & Turbine) Hybrid 시스템이다. 그러나 본 연구의 기술은 연료전지 배열을 이용한 Coanda 공기증폭기를 장착한 새로운 개념의 고효율 연료전지 시스템이다. 원래 공기 증폭기는 완만한 곡면 주위를 흐르는 유체가 곡면의 표면을 따라 흐름의 방향이 바뀌는 원리(Coanda Effect)를 이용한 장치로서, 소량의 고압유체를 구동 에너지원으로 사용하여 최고 20배에 해당하는 많은 양의 주변 유체를 빠른 속도로 이송시키는 역할을 한다. 문제는 고압의 유체원을 만드는 것인데, 본 연구에서는 발전용 연료전지 시스템의 배기가스를 활용하여 먼저 고압의 수증기를 발생시키고, 다음으로 고압의 수증기를 공기 증폭기의 구동원으로 사용함으로써 연료전지 시스템의 Air blower를 대체하는 것이다. 이러한 개념을 검증하기 위해서 고압의 스팀작동 Coanda 공기증폭기를 제작하여 선행실험을 진행하였다. 먼저 공기증폭기의 Gap 및 스팀압력에 따른 공기유량, 압력 등의 기본특성을 조사하였고, 출력 공기의 특성을 개선하기 공기증폭기의 형상 및 재료를 새롭게 설계하였다. 그리고 실제 시스템의 적용가능성을 알아보기 위해서, 예로 300kW급 용융탄산염 연료전지 발전시스템의 Air blower 대체가능성을 확인하였고, 배열이용 Coanda 공기증폭기를 활용한 고효율 연료전지 시스템의 개념설계를 수립하였다. 결론적으로 본 기술을 활용하면 연료전지 시스템의 최종 전기효율을 향상시킬 뿐 아니라는 시스템의 장기 신뢰성을 증대시키는 효과를 기대할 수 있다.

  • PDF

Simulation Model of AC Interconnection System for CHP(Combined Heat and Power) Generation (계통연계형 열병합발전시스템의 시뮬레이션모델)

  • Jeong, Jong-Kyou;Yun, Dong-Jin;Kwon, Ki-Hyun;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.164-166
    • /
    • 2008
  • 본 논문은 계통연계형 열병합발전의 동작특성을 모의하는 시뮬레이션모델에 관해 기술하고 있다. 계통연계형 열병합발전은 가스엔진, 영구자석발전기, 전력변환기로 구성되어 있는데 본 연구에서는 가스엔진은 일정출력을 공급하고 다극형 영구자석발전기에서 생산되는 400Hz 출력을 컨버터와 인버터를 통하여 상용주파수의 교류로 전력계통과 연계하는 것으로 가정하였다 개발된 시뮬레이션모델은 PSCAD/EMTDC를 이용하였고 전력회로는 내장모듈을 그리고 제어기는 C 프로그램으로 직접 개발하였다. 개발된 PSCAD/EMTDC 시뮬레이션모델을 이용한 다양한 시뮬레이션을 실시하여 하드웨어 시뮬레이터를 설계하였다.

  • PDF

Current and Future Trends of District Heating System for a Sustainable Future and Greenhouse Gas Reduction (온실가스 감축 및 지속가능 미래를 위한 집단에너지사업 방향)

  • Jung, Min-Jung;Park, Jin-Kyu;Ahn, Deog-Yong;Lee, Nam-Hoon
    • Journal of Climate Change Research
    • /
    • v.8 no.4
    • /
    • pp.377-384
    • /
    • 2017
  • Amid growing concerns about energy security, energy prices, economic competitiveness, and climate change, district heating (DH) system has been recognized for its significant benefits and the part it can play in efficiently meeting society's growing energy demands while reducing environmental impacts. Policy makers often need to quantify the fuel and carbon dioxide ($CO_2$) emissions savings of DH system compared to conventional individual heating (IH) system in order to estimate its actual emissions reductions. The objective of this paper is to calculate energy efficiency and $CO_2$ emissions saving, and to propose the future direction for DH system in Korea. DH system achieved total system efficiencies of 67.9% compared to 54.1% for IH system in 2015. DH system reduced $CO_2$ emissions by $381,311ton-CO_2$ (4.1%) compared to IH system. The results suggest that DH system is more preferred than IH system using natural gas. In Korea, the aim is to reduce dependence on fossil fuels and to use energy more efficiently. DH system have significant potential with regard to achieving this aim, because DH system are already integrated with power generation in the electricity since combined heating and power (CHP) are used for heat supply. Although the future conditions for DH may look promising, the current DH system in Korea must be enhanced in order to handle future competition. Thus, the next DH system must be integrated with multiple renewable energy and waste heat energy sources.

A Study on Simplified Robust Optimal Operation of Microgrids Considering the Uncertainty of Renewable Generation and Loads (신재생에너지와 부하의 불확실성을 고려한 마이크로그리드의 단순화된 강인최적운영 기법에 관한 연구)

  • Lee, Byung Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.513-521
    • /
    • 2017
  • Robust optimal operation of a microgrid is required since the increase of the penetration level of renewable generators in the microgrid raises uncertainty due to their intermittent power output. In this paper, an application of probabilistic optimization method to economical operation of a microgrid is studied. To simplify the treatment of the uncertainties of renewable generations and load, the new 'band of virtual equivalent load variation' is introduced considering their uncertainties. A simplified robust optimization methodology to generate the scenarios within the band of virtual equivalent load variation and to obtain the optimal solution for the worst scenario is presented based on Monte Carlo method. The microgrid to be studied here is composed of distributed generation system(DGs), battery systems and loads. The distributed generation systems include combined heat and power(CHP) and small generators such as diesel generators and the renewable energy generators such as photovoltaic(PV) systems and wind power systems. The modeling of the objective function for considering interruption cost by the penalty function is presented. Through the case study for a microgrid with uncertainties, the validity of proposed robust optimization methodology is evaluated.

A Study for the Methodology of Analyzing the Operation Behavior of Thermal Energy Grids with Connecting Operation (열 에너지 그리드 연계운전의 운전 거동 특성 분석을 위한 방법론에 관한 연구)

  • Im, Yong Hoon;Lee, Jae Yong;Chung, Mo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.143-150
    • /
    • 2012
  • A simulation methodology and corresponding program based on it is to be discussed for analyzing the effects of the networking operation of existing DHC system in connection with CHP system on-site. The practical simulation for arbitrary areas with various building compositions is carried out for the analysis of operational features in both systems, and the various aspects of thermal energy grids with connecting operation are highlighted through the detailed assessment of predicted results. The intrinsic operational features of CHP prime movers, gas engine, gas turbine etc., are effectively implemented by realizing the performance data, i.e. actual operation efficiency in the full and part loads range. For the sake of simplicity, a simple mathematical correlation model is proposed for simulating various aspects of change effectively on the existing DHC system side due to the connecting operation, instead of performing cycle simulations separately. The empirical correlations are developed using the hourly based annual operation data for a branch of the Korean District Heating Corporation (KDHC) and are implicit in relation between main operation parameters such as fuel consumption by use, heat and power production. In the simulation, a variety of system configurations are able to be considered according to any combination of the probable CHP prime-movers, absorption or turbo type cooling chillers of every kind and capacity. From the analysis of the thermal network operation simulations, it is found that the newly proposed methodology of mathematical correlation for modelling of the existing DHC system functions effectively in reflecting the operational variations due to thermal energy grids with connecting operation. The effects of intrinsic features of CHP prime-movers, e.g. the different ratio of heat and power production, various combinations of different types of chillers (i.e. absorption and turbo types) on the overall system operation are discussed in detail with the consideration of operation schemes and corresponding simulation algorithms.

Large-scale Virtual Power Plant Management Method Considering Variable and Sensitive Loads (가변 및 민감성 부하를 고려한 대단위 가상 발전소 운영 방법)

  • Park, Yong Kuk;Lee, Min Goo;Jung, Kyung Kwon;Lee, Yong-Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.225-234
    • /
    • 2015
  • Nowadays a Virtual Power Plant (VPP) represents an aggregation of distributed energy resource such as Distributed Generation (DG), Combined Heat and Power generation (CHP), Energy Storage Systems (ESS) and load in order to operate as a single power plant by using Information and Communication Technologies, ICT. The VPP has been developed and verified based on a single virtual plant platform which is connected with a number of various distributed energy resources. As the VPP's distributed energy resources increase, so does the number of data from distributed energy. Moreover, it is obviously inefficient in the aspects of technique and cost that a virtual plant platform operates in a centralized manner over widespread region. In this paper the concept of the large-scale VPP which can reduce a error probability of system's load and increase the robustness of data exchange among distributed energy resources will be proposed. In addition, it can directly control and supervise energy resource by making small size's virtual platform which can make a optimal resource scheduling to consider of variable and sensitive load in the large-scale VPP. It makes certain the result is verified by simulation.