• Title/Summary/Keyword: Combined Transmission Systems

Search Result 138, Processing Time 0.037 seconds

A Study on Overvoltage Reduction Method of Single Point Bonded Section on Combined Transmission Lines (혼합송전선로 편단접지 구간 과전압 저감 방안에 관한 연구)

  • Jung, Chae-Kyun;Kang, Ji-Won;Park, Hung-Sok;Kim, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1881-1887
    • /
    • 2009
  • This paper discusses the effects of ECC (Earth Continuity Conductor) for reducing the level of induced sheath overvoltages at the single point bonded section of combined transmission lines which are mixed underground power cable with overhead line in one T/L. In previous papers, the characteristics of ECC on only underground power cable systems were sufficiently analyzed. However, the result of only underground power cable systems are totally different from that of combined transmission lines because ECC is commonly grounded with overhead grounding wire at mesh of cable head. Therefore, in this paper, the installation effects of ECC have been variously analyzed considering the three kinds of fault positions, cable formation of duct and trefoil, spacing between phase conductor and ECC, and the change of overhead transmission line section length on 154kV combined transmission line. Finally, simulation results show that ECC can effectively reduce the induced sheath voltage.

Analysis of Switching Overvoltage on Operating Reclosing in Combined Transmission Systems (혼합송전계통에서 재폐로 시행시 개폐과전압 해석)

  • Lim, Kwang-Sik;Lee, Jong-Boem;Jung, Chae-Kyun;Kang, Ji-Won;Park, Hung-Sok
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.391-393
    • /
    • 2008
  • This paper is analysed by switching overvoltage on operating reclosing in 154 [kV] combined transmission systems. Combined transmission systems are modeled by EMTP/ATPDraw program. It is fault condition that simulate high resistance earth fault. The simulation is carried out considering variation of parameters such as resistance value of fault point and rate of underground line.

  • PDF

Proper Cable Arrangement Selection by Induced Voltage Evaluation of DC Cable in AC/DC Hybrid Combined Transmission Systems (AC/DC 하이브리드형 혼합송전계통에서 DC 케이블의 유도전압평가에 의한 적정배열 선정)

  • Son, Yong-Dae;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.680-688
    • /
    • 2015
  • Hybrid type combined transmission systems is being operated by AC and DC line at the same space will be expanded instead of the overhead line. However, such hybrid type combined system has problem like the arrangement selection of DC cable for effective system operation. In this paper, to select the proper arrangement of DC cable, induced voltage of DC cable influenced by AC cable was analyzed in case of several type arrangement of DC cable. Such induced voltage is in detailed analyzed not only in case of steady, but transient state. The arrangement which has the lowest induced voltage is selected as the proper one. EMTP/ATPDraw is used for modeling and analysis of hybrid type combined transmission system.

Improvement of Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line (웨이브렛을 이용한 혼합송전선로에서의 거리계전 알고리즘 개선)

  • 정채균;김경호;하체웅;이종범;윤양웅
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.593-601
    • /
    • 2003
  • Distance realy is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding resistance, and sheath voltage limiters(SVLs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable systems, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using D1 coefficient summation in db4. And also, error compensation value was proposed for correct calculation of impedance in power cables section.

Fault Location in Combined Transmission Systems Using Wavelet Transform (웨이브렛 변환을 이용한 혼합송전계통에서의 Fault Location)

  • Jung, Chae-Kyun;Hong, Dong-Suk;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.226-229
    • /
    • 2001
  • The combined transmission lines with the underground power cables are continuously expanded in power systems. So the fault of combined transmission line is increased every year as the complication of underground transmission line. In this paper. traveling wave theory and DWT wavelet transform are used for fast and accurate detection of fault location at the combined transmission line. Traveling wave travels to each bus like surge and repeats reflection and transmission till transient signal is completely disappeared. When fault is occurred on overhead and underground tine, the fault location detecting algorithm was performed with using continuous peak value time-delay of traveling wave reflected from A bus.

  • PDF

A Study on a Fault Location Algorithm Using Wavelet Transform in Combined Transmission Systems (혼합송전계통에서 웨이브렛 변환을 이용한 고장점 탐색 알고리즘에 관한 연구)

  • Jeong, Chae-Gyun;Lee, Jong-Beom;Yun, Yang-Ung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.5
    • /
    • pp.247-254
    • /
    • 2002
  • This paper describes a fault location algorithm in real combined transmission systems with underground power cable. The algorithm to calculate the fault location was developed using DWT wavelet transform and travelling wave occurred at fault point. And the proposed algorithm is also used the transient signal of one end in stead of the signal information of two ends. On the other hand, in this papers, the method to discriminate fault point between overhead line and cable section is also Proposed. Variety simulations were carried out to verify the accuracy and effectiveness of the proposed algorithm using EMTP/ATFDraw and Matlab. Simulation results show that the proposed method has the excellent ability for discrimination of fault section and fault location in combined transmission systems with power cables.

Comparative Analysis and Improvement of Transmitting Efficiency in RF Wireless Charging System (RF무선충전 시스템 전송효율 개선 및 비교 분석)

  • Son, Myung Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.4
    • /
    • pp.102-107
    • /
    • 2021
  • In this paper, the measurements of received power was shown and compared in two developed 5.8GHz 25W wireless charging systems. One is the system using commercial transmission antenna, and the other is the system using transmission antenna combined with metamaterial. The system combined with metamaterial shows higher received power due to negative reflective index of metamaterial. In addition, a comparative analysis of the systems shows that the transmission efficiency in the systems can decrease the real gain of transmission antenna due to higher side robe of beam pattern. The side robe beams of transmitting antenna interferes transmitted beam with the reflected beams from the bottom region due to the side robes. The failure problems of the RF wireless charging systems are discussed and proposed in order to charge mobile devices through the RF wireless charging system.

Fault Location Using Neuro-Fuzzy for the Line-to-Ground Fault in Combined Transmission Lines with Underground Power Cables (뉴로-퍼지를 이용한 혼합송전선로에서의 1선지락 고장시 고장점 추정)

  • 김경호;이종범;정영호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.602-609
    • /
    • 2003
  • This paper describes the fault location calculation using neuro-fuzzy systems in combined transmission lines with underground power cables. Neuro-fuzzy systems used in this paper are composed of two parts for fault section and fault location. First, neuro-fuzzy system discriminates the fault section between overhead and underground with normalized detail coefficient obtained by wavelet transform. Normalized detail coefficients of voltage and current in half cycle information are used for the inputs of neuro-fuzzy system. As the result of neuro-fuzzy system for fault section, impedance of selected fault section is calculated and it is used as the inputs of the neuro-fuzzy systems for fault location. Neuro-fuzzy systems for fault location also consist of two parts. One calculates the fault location of overhead, and the other does for underground. Fault section is completely classified and neuro-fuzzy system for fault location calculates the distance from the relaying point. Neuro-fuzzy systems proposed in this paper shows the excellent results of fault section and fault location.

Modeling and Switching Overvoltage Analysis for Reclosing Analysis in Combined Transmission Systems (혼합송전계통에서 재폐로 해석을 위한 모델수립 및 개폐과전압해석)

  • Lim, Kwang-Sik;Lee, Jong-Beom;Kang, Ji-Won;Jung, Chae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.442-443
    • /
    • 2008
  • This paper describes modeling using the EMTP/ATPDraw for reclosing analysis in 154kV combined transmission systems, and analyzes switching overvoltage. Current transformer established at lead-in area and lead-out area in transmission line and circuit breaker were modeled using TACS in the EMTP/ATPDraw. And also MODELS was constructed by signal processing of the operating reclosing. The simulation was carried out the switching overvoltage according to the length of overhead and underground transmission line, overvoltage between sheath and earth, and voltage between joint boxes.

  • PDF

Generalized Analysis on the Combined Effect of SPM and Fiber Chromatic Dispersion on Subcarrier Multiplexed Optical Transmission Systems for RoF Applications

  • Kim, Kyoung-Soo;Lee, Jae-Hoon;Jeong, Ji-Chai
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.132-139
    • /
    • 2011
  • We investigate theoretically the combined effect of fiber chromatic dispersion and self-phase modulation (SPM) on multi-channel subcarrier multiplexed (SCM) optical transmission systems in terms of the detected RF carrier power and SPM-induced power gain after transmission over single-mode fiber (SMF) links. According to the calculated power gain due to the SPM effect at the transmission distance of P3dB using the detected radio-frequency (RF) carrier power after photo-detection, the power gain is significantly degraded with large optical modulation index (OMI), small SCM channel spacing, and large fiber launching power because of the increased interaction between subcarrier channels. The nonlinear phase shift due to linear and nonlinear fiber characteristics is investigated to explain these results in detail. The numerical simulation results show that the OMI per SCM channel has to be smaller than 10 % for the fiber launching power of 10 dBm to guarantee prevention of SPM-induced power gain degradation below 0.5 dB for the SCM system with the channel spacing of 100 MHz. This result is expected to be utilized for the optical transmission systems using the SCM technology in future radio-over-fiber (RoF) networks.