• 제목/요약/키워드: Combined Test

검색결과 2,662건 처리시간 0.034초

배전용 폴리머애자 열화특성 평가를 위한 복합열화 시험장치 구축 (A Combined Aging Test Facility for Evaluating an Aging Characteristics of Distribution Polymer Insulators)

  • 이병성;한재홍;김찬영;윤태상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1948-1950
    • /
    • 2000
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. Especially, these insulators are subjected to the environmental stress such as ultraviolet radiation, electrical stress, mechanical load, etc.. Hence, in this paper, we simulated the factors having influence on aging of polymer insulators using the combined aging test chamber. In order to evaluate an aging characteristics with time, we measured leakage current on these insulators to make out the degree of aging.

  • PDF

석탄가스화 발전슬래그를 잔골재로 사용한 콘크리트 Mock-up 부재의 공학적 특성 (Engineering Properties of Concrete Mock-up Using Coal Gasification Slag as Fine Aggregate.)

  • 한준희;이영준;현승용;한민철;윤기원;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.159-160
    • /
    • 2018
  • In this study, the characteristics of the Mock-up test were reviewed to analyze the applicability of the coal gasification slag (CGS) from the integrated gasification combination Cycle (IGCC) to the concrete fine aggregate. The analysis shows that CGS and crushed sand mix is the best combination of CGS combined with about 50 % of CGS based on the effects of promoting liquidity and strength. This is expected to be a positive factor in securing the strength and flexibility of concrete given the optimal mix of CGS, and may also contribute to the improvement of quality.

  • PDF

전호(Anthriscus sylvestris) 뿌리 정유의 항균 및 항산화 작용 (Antibacterial and Antioxidant Activities of the Essential Oil from the Roots of Anthriscus sylvestris)

  • 임혜림;신승원
    • 약학회지
    • /
    • 제56권5호
    • /
    • pp.320-325
    • /
    • 2012
  • To develop a new effective and safe natural antibiotics and antioxidant the essential oil was extracted from the roots of Anthriscus sylvestris by steam distillation. Its composition was analyzed by GC-MS. The activities of the essential oil fraction and its main components were evaluated against antibiotic-susceptible and -resistant strains of some food-born bacteria. In addition the synergism was examined with this oil combined with antibiotic by checkerboard titer test. The antioxidant activities were determined by in 1,1-diphenyl-2-picryl-hydrazil (DPPH) free radical scavenging activity test and reducing power assay. The essential oil fraction of A. sylvestris revealed significant inhibiting activities against antibiotic-susceptible and -resistant species of Vibrio and Shigella with MICs ranged from 1.00~4.00 mg/ml. It showed synergistic or additive effects when it was combined with amphicillin or trimethoprim/sulfamethoxazole (1 : 9). Additionally, the essential oil fraction of A. sylvestris exhibited significant DPPH free radical scavenging activity and the reducing power.

조합형 윅을 사용한 히트파이프의 작동특성에 관한 실험적 연구 (Experimental study on the working characteristic of a heat pipe with combined wick)

  • 홍진관;부준홍;정원복
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.236-243
    • /
    • 1999
  • Aluminum/Freon-22 heat pipes were manufactured and tested which have a special wick geometry combining axial groove and screen mesh. There were 14 axial grooves in a cross-section and these were covered by two layers of 350 mesh screens to enhance the thermal performance. The performance test was conducted by varying the thermal load and tilt angle. Furthermore, the operation limits and overall heat transfer coefficient were investigated. The experimental results will be useful in a variety of applications, especially in design and manufacturing of a high-efficiency heat exchanger and energy recovery systems.

  • PDF

화강암골재를 사용한 콘크리트의 강도추정식 개발 (Development of Compressive Strength Estimation Equation for Concrete Mixed with Granite Aggregates)

  • 임홍철;서태석;우상균;송영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.91-98
    • /
    • 2002
  • Prediction for the compressive strength of concrete by non-destructive tests(NDT) has a tendency to show different outcomes according to various aggregates. The purpose of this study is to develop estimation equation by rebound number, ultrasonic velocity and combined method at concrete structures which used granite as coarse aggregates. The test variable is water/cement ratio(41.1%, 48.6%, 67.6%), curing method(moisture condition, dry condition) and age(7, 14, 28, 56). According to the test variable, new equation was suggested, and compared with the existing equations.

이형 하부다이아프램으로 보강된 각형 CFT 기둥-보 접합부의 내진성능에 관한 연구 (A Study on Seismic Performance for CFT Square Column-to-Beam Connections Reinforced with Asymmetric Lower Diaphragms)

  • 최성모;윤여상;김요숙;김진호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.163-171
    • /
    • 2003
  • Most of existing beam-to-column connections are reinforced symmetrically because of reverse action cause by earthquake but in the weak-earthquake region like Korea connections reinforced asymmetrically can be used. Specially, the connections between CFT(Concrete Filled Tube) column and H-shape beam can be applied by simplified lower diaphragm. The tensile capacity of Combined Cross Diaphragm for upper reinforcing was tested by simple tension test and four types for lower reinforcing; Combined Cross, None, Horizontal T-bar and Vertical Plate were tested by ANSI/AISC SSPEC 2002 loading program. Horizontal T-bar and stud bolts in vertical flat bar transmit tensile stress from bottom flange of beam to filled concrete. All test specimens were satisfied 0.01 radian of inelastic rotational requirement in ordinary moment frame of AISC seismic provision. As the results of parametric studies, simplified lower diaphragms demonstrated an outstanding strength, stiffness and plastic deformation capacity to use sufficient seismic performance in the field.

  • PDF

Development of Durable Reliability Assessment Methods for Heavy Duty Coatings

  • Kim, Seung-Jin;Jung, Ho;Yang, In-Mo;Tanaka, Takeyuki
    • Corrosion Science and Technology
    • /
    • 제4권4호
    • /
    • pp.155-163
    • /
    • 2005
  • Heavy duty coating are required to have minimum durable period of 15 years under average usage environment because these paints are coated with purpose of anti-corrosion, antifouling, plastering etc. Onto steel structures constructed upon land and sea and other ferrous structures of electric power generation plants, electricity transmission towers, large structures of various plants, etc. Therefore we tried to estimate heavy duty coating longevity through reliability evaluation method and used combined cyclic anti-conrrosion test method composed of drying, moisturizing and salt spray as for accelerated life test to estimate longevity. Accelerated life test hours to heavy duty coating of first grade (with longevity not less than 15 years) specification may be obtained from troubleless test hours $t_n=\frac{B_p}{n^{1/\beta}}\left[\frac{1n(1-CL)}{1n(1-p)} \right]^{1/\beta}=19.671$ (yr) where shape parameter $\beta=1.1$, confidence level CL=80 %, warranty life $B_{10}=15$ yr and sampling size n=10 (2 sets). Because acceleration factor {AF} found by accelerated test is 41.7, accelerated life test hours required may be represented about 4,132 hr so that if this amount of hours is converted to number of cycles(6 hr/cycle) of complex cycle corrosion resistance test then the amount is tantamount about 690 cycles. That means if there does not occur trouble failure (with defect factor sum not more than 20) during when there is performed 690 cycles of combined cyclic anti-corrosion test to heavy duty coating specimen then it signifies that there can be warranted longevity $B_{10}$ of 15 yr under condition of confidence level CL=80 %.

함정사업 시험평가의 효율적 수행방안에 관한 연구 (A Study on Efficient Test & Evaluation Methods in Naval Ship Acquisitions)

  • 김재용;최원석;홍석윤;정현균;송지훈;임우석;권현웅
    • 한국군사과학기술학회지
    • /
    • 제19권6호
    • /
    • pp.703-711
    • /
    • 2016
  • The purposes of this study is to identify the problems arising from current Test & Evaluation process of the naval ship acquisition program and to suggest methods to increase the acquisition efficiency. Considering that the present rule of developmental test &evaluation(DT&E) and operational test & evaluation(OT&E) has caused an inefficiency effect on the acquisition procedures due to the limited practices on it, the DT&E and OT&E procedures through test & evaluation master plan(TEMP) is proposed based on the selective practices of the defense instruction articles. Also, considering characteristics of naval ship acquisitions, efficient procedure systems are derived through case analysis results by comparing each performances of the system. The suggested methods are able to meet the requirements of the changed acquisition environments and also increase efficiency of acquisition systems by adoption of DT&E and OT&E combined test scheme.

TTCN을 사용한 추상시험스위트 작성 방안 (Description of Abstract Test Suite using TTCN)

  • 박용범;진병문
    • 한국정보처리학회논문지
    • /
    • 제5권1호
    • /
    • pp.128-136
    • /
    • 1998
  • 프로토콜에 대한 적합성시험을 기술하기 위한 국제 시험 표준 언어인 TTCN(Tree and Tabular Combined Notation)은 추상시험스위트의 전체적인 구조, 시험 목적의 표현 그리고 각 시험 기술 요소에 대한 개념과 표기법을 제공하고 있다. 이 논문에서는 TTCN을 사용하여 프로토콜 시험 규격 즉 추상시험스위트를 기술함에 있어서 추상시험스위트의 각 요소에 대해 고려하여야 할 점을 설명하고, 실제적인 시험 기술 경험을 토대로 시험 적용범위의 검증이 용이하고 사용자에게 많은 정보를 줄 수 있는 시험제약과 시험경우에 대한 명명법을 제안하였다. 또한 이 논문에서는 추상시험스위트를 수행 가능한 형태로 변환하여 시험대상에 대해 적용할 때 실제 환경의 제한으로 인하여 발생할 수 있는 문제점을 분석하고 이를 추상 시험스위트 작성 단계에서 미리 해결하는 방안을 제시하였다. 이 논문에서는 ATM Forum UNI 3.1 신호방식 프로토콜 스택 중 AAL(ATM Adaptation Layer)계층의 부계층인 SSCOP(Service Specific Connection Oriented Protocol) 프로토콜을 대상으로 하여 사례를 제시하고, 이를 바탕으로 TTCN 사용의 문제점을 고찰하고 그 해결 방안을 제시하였다.

  • PDF

설린닥의 경구용 지속성 제제설계 및 생체이용율 (The Formulation and Bioavailability of Oral Sustained Release Sulindac Delivery System)

  • 이계주;박선희;황성주
    • 약학회지
    • /
    • 제41권1호
    • /
    • pp.60-73
    • /
    • 1997
  • In order to design a 24 hr sustained release preparation of sulindac for oral administration, fast release pellet (FR), slow release pellet (SR) and two combined formulation (1 : 1 and 1 : 2) were prepared. The pharmacokinetic effect of such preparations has been evaluated using rabbits as a suitable in vivo model, and tested in man. Dose determination was carried out using curve fitting according to RSTPJP II program. In bioavailability test using rabbit, AUCs of sulindac in a few designed formulations were similar to each other. $C_{max}$- of RF and SR were 1.8 times and 1.2 times higher, respectively, compared to that of combined formulation (FR:SR=1:1). While plasma concentration of FR and SR decreased rapidly, that of combined formulation (FR:SR 1:1) lasted at the level close to $C_{max}$ for 24 hrs. Plasma concentration of sulfide form from the combined pellet(FR:SR=1:1) lasted for 24 hrs, and its AUC value was 1.4-fold, 2.7-fold. and 1.2-fold greater than FR pellet, SR pellet and combined pellet (FR:SR 1 : 2). Thus, the combined pellet of 1:1 ratio was found to be the most effective for oral sustained release formulation. Bioavailability test in human showed that AUC of sulfide from TSRP (1 : 1) was approximately 1.5 times greater than total AUC of Immbaron$^{\circledR}$ administered twice in a day. While $T_{max}$ of sulfide from lmmbaron$^{\circledR}$ was 4.33 +/- 1.37 hr (lst administration) and 3.33 ${pm}$ 0.82 hr (2nd administration), respectively, that of sulfide from TSRP increased to 7.17 ${pm}$ 2.86 hr. Plasma concentration of sulfide from TSRP was sustained at more, than 1.0 ${\mu}g{\cdot}$hr/ml until 24 hrs after one dose administration. In addition, TSRP may decrease local adverse reaction in the stomach, since plasma concentration of sulfide from the combined pellet was low within 2hrs in the stomach. In conclusion, it is suggested that TSRP formulation may be effective for oral 24 hr sustained release formulation of sulindac dosing 300 ~ 350mg once a day.

  • PDF