• 제목/요약/키워드: Combined Deterioration

검색결과 179건 처리시간 0.026초

반강접 접합부를 갖는 평면 강골조의 거동에 관한 해석적 연구 (Analytical Study on Behaviour of Plane Steel Frame with Semi-Rigid Beam-to-Column Connection)

  • 김종성
    • 한국강구조학회 논문집
    • /
    • 제21권5호
    • /
    • pp.483-492
    • /
    • 2009
  • 소성영역에서 부재의 강성감소, 휨효과 및 잔류응력의 영향을 고려하면서 극한 한계상태에서 강골조의 거동을 평가하기 위해 개선 소성 힌지법을 이용하여 평면강골조의 비선형해석을 실시하고, 강접 및 반강접 평면강골조의 다양한 모델에 대한 수치해석을 통하여 거동을 평가하는데 목적이 있다. 그리고 상용프로그램을 이용한 해석결과를 이용하여 반강접율의 변화에 따른 골조의 거동을 분석한다.

라빌레뜨 이후 현대건축에서 나타난 폴리 프로젝트 사례 연구 (A Study on the Cases of Folly Project in the Contemporary Architecture After Parc de la Villette)

  • 강효정
    • 한국실내디자인학회논문집
    • /
    • 제23권3호
    • /
    • pp.144-152
    • /
    • 2014
  • This study evaluated how folly is experimented in the contemporary architecture after 30 years when Bernard Tchumi first introduced it to the public by the modern transformation as a garden ornament. First, folly project has been carried out based on the general concept of energizing dwindling cities. However, it has changed to the direction of adding specific programs. Also, along urban regeneration that does not change deterioration of previous structures, Folly changed in the emphasis on readjust existing structure. Second, by having different designers presenting their own follies during the Osaka Expo, folly now has part on visual exhibition element. This has similarity with public art project, yet it could more actively intervene for urban regeneration compared to conventional environment sculpture. Third, folly is experimented as the event-installation art combined form of architecture and art where people could experience the space and enjoy art. Fourth, folly enabled the landscaping of architecture and expanding city planning. Recently Gwangju Folly invited various arts, social, and cultural professionals to converge city design with architecture, landscaping, and other diverse genres.

외상성 흉요추접합부 파열골절의 전측방경유법에 의한 신경감압 및 기구고정술 (Anterolateral Surgical Decompression and Instrumentation in Thoracolumbar Bursting Fracture)

  • 배장호
    • Journal of Yeungnam Medical Science
    • /
    • 제13권2호
    • /
    • pp.234-242
    • /
    • 1996
  • 영남대학교 의과대학 부속병원 신경외과에서 1994년 l월부터 1994년 12월까지 1년간 흉요추접합부 파열골절로 입원한 환자중 전측방경유법으로 10례를 수술로 치료경험 하였던 바, 척추골절이 척수원추 상부이면서 전방의 골편에 의해 척수신경이 압박되고 있는 불안정 파열골절시는 전방도달술에 의한 늑골 골융합 및 Kaneda기기내고정술로 좋은 결과를 기대할 수 있겠고, 척수 후주의 심한 손상이나 또는 3 column을 전체가 손상된 불안정 파열골절의 경우에는 후방접근법이나 후측방접근법으로 신경감압 및 내고정술 시행하는 것이 좋은 치료법이라 할 수 있겠다.

  • PDF

남매에서 가족력을 가진 galactosialidosis 1례 (Galactosialidosis with a Family History in a Sibling)

  • 임선주;남상욱
    • 대한유전성대사질환학회지
    • /
    • 제6권1호
    • /
    • pp.32-39
    • /
    • 2006
  • 저자들은 출생 후 정상적인 발달을 보이다가 생후 6개월부터 의식과 운동 발달의 퇴행을 보이던 13개월 환아에서 효소 검사를 시행하여 ${\beta}$-galactosidase의 결핍을 확인하고 $GM_1$-gangliosidosis type 1으로 진단하였지만, 후에 추가적으로 시행한 효소 검사에서 ${\alpha}$-neuraminidase의 결핍도 발견되어 galactosialidosis로 진단한 증례를 경험하였기에 문헌 고찰과 함께 보고하고자 한다.

  • PDF

플라이 애시와 고로슬래그 미분말을 복합 활용한 3성분계 혼합 콘크리트의 내구성능에 대한 실험적 연구 (An Experimental Study on the Durability Performance for Ternary Blended Concrete Containing Both Fly Ash and Granulated Blast Furnace Slag)

  • 이창수;윤인석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.139-145
    • /
    • 2003
  • Ternary blended concrete, which contains both fly ash and granulated blast furnace slag, has an initial cost effective and is environment friendly. Furthermore, it has a lot of technical advantages such as the improvement of long term compressive strength, high workability, and the reduction of hydration heat. However, as the use and study on the performance of ternary blended concrete is limited, it is worthwhile studying the actual performance of this technology. This study examined the durability performance of ternary blended concrete, compared to binary blended concrete and ordinary portland concrete. It led to the conclusion that ternary blended concrete is very suitable for submerged members under marine environment. However, it should be noticed that ternary blended concrete becomes weak on carbonation, when it is situated on combined deterioration environment of carbonation and chloride. Therefore, the curing duration of ternary blended concrete should be prolonged in order to enhance the resistance of carbonation.

Assessment of water quality in an artificial urban canal: A case study of Songdo City in South Korea

  • Ahn, Jungkyu;Na, Yeji;Park, Sung Won
    • Environmental Engineering Research
    • /
    • 제24권4호
    • /
    • pp.582-590
    • /
    • 2019
  • Currently, the waterfront facility was constructed in New Songdo City, South Korea. It has the various water leisure areas and especially an artificial urban canal with filtered seawater by re-circulating flow system. However, due to excessive amount of nutrients from seawater combined with complicated geometry, it is highly vulnerable to deterioration of water quality. In this study, flow characteristics and pollutant transport were analyzed with comprehensive numerical models, MIKE 3 FM and ECO-lab. Based on these numerical results, notable sampling points were selected for field measurements and comparison between modeling and measured results were conducted. In addition, the integrated water quality evaluation index, Water Quality Index was applied to analyze various water quality issues. We also set up scenarios to control the two kinds of water quality factors, dissolved oxygen (DO), and total phosphorus (TP). As a result, the effect of 20% reduction of TP was less than 10% and it was almost ineffective for a year but it was reduced by up to 40% in case of scenario which DO is increased by 20%. Therefore, it was recommended to control the DO concentration, usually by applying re-aeration facility, rather than TP in artificial urban canal with seawater.

섬유망을 이용한 RC슬래브의 균열제어 (The Crack Control of Fiber Net Reinforced RC Slab)

  • 배주성;김경수;김남욱;김철민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.225-231
    • /
    • 2002
  • Severe cracks on Reinforced Concrete (RC) structures caused by structural displacement can be often one of the main reasons for the degradation of tensile and flexural rigidities of RC structures and for the deterioration of durability and serviceability of RC structures through accelerated steel corrosion. These combined factors adversely affect the performance of RC concrete, leading to shortened life time of RC structures. In consideration of these problems, we conducted 3 point bending experiments by employing three different types of concrete specimens: fiber-net reinforced concrete (FNRC), polypropylene-fiber reinforced concrete (PFRC), and plain concrete (PC). FNRC is well known for its strong corrosion resistance, light self-weight, and excellent tensile strength, while PFRC is known to be effective in crack control. FNRC was found to have the best first and final crack resistances followed by PFRC and PC, as evidenced by the highest initial crack load and the smallest final crack width, respectively. The FNRC specimens with various tensile strength of fiber net exhibited greater ultimate strengths than those for PFRC and PC. Furthermore, the crack widths of FNRC specimens were smaller than those calculated by the crack-width estimation equation of the KCI and ACI code. Therefore, we conclude that fiber net reinforcement is effective not only on crack control, but also on loading share.

3상 유도전동기 구동장치의 동상모드 전류 능동 제거법 (An Active Cancellation Method for the Common Mode Current of the Three-Phase Induction Motor Drives)

  • Uzzaman, Tawfique;Kim, Unghoe;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 추계학술대회
    • /
    • pp.96-97
    • /
    • 2019
  • Pulse Width Modulation (PWM) is a widely adopted technique to drive the motor using the voltage source inverters. Since they generate high frequency Common Mode (CM) Voltage, a high shaft voltage in induction motor is induced which leads to parasitic capacitive currents causing adverse effects such as premature deterioration of ball bearings and high levels of electromagnetic emissions. This paper presents an Active Cancellation Circuit (ACC) which can significantly reduce the CM voltage hence the common mode current in the three phase induction motor drives. In the proposed method the CM voltage is detected by the capacitors and applied to the frame of the motor to cancel the CM voltage hence the CM current. Unlike the conventional methods the proposed method does not insert the transformer in between the inverter and motor, a high power rating three phase transformer is not required and no losses associated with it. In addition the proposed method is applicable to any kind of PWM motor drives regardless of their PWM methods. The effectiveness of the proposed method is proved by the experiments with a three phase induction motor (1.1kW 415V/60Hz) combined with a three phase voltage source inverter modulated by the Space Vector Modulation (SVM).

  • PDF

기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류 (Properties and classification of air discharge by Kohonen network)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

장스팬 슬라브 콘크리트의 열화저감에 대한 연구 (A Study on Reducing Deterioration in Long-span Slab Concrete)

  • 김대건;차훈;최상환;문경식
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.11-12
    • /
    • 2014
  • In this study, fundamental properties of concrete mixed with fiber has been analysed. Compressive strength, tensile strength and plastic shrinkage has been tested to conduct the optimum addition ratio of fiber. Effect to control press concrete's cracking has been tested. The following results could be made as the conclusion. For the flowability, slump decreased about 41-79% when all types of fiber used in the concrete. When the addition ratio of fiber is 1.2%, the slump of concrete decreased about 45%. For the strength properties. all the specimens with different addition ratio of fiber shown higher compressive strength comparing with Plain. Comparing with Plain, cracking decreased when the fiber added. Especially, when NY fiber used in the concrete, the plastic shrinkage did not occurred. In addition, Latex modified concrete(LMC) has improved superior physical and chemical properties. The properties of latex, combined with the low water-cement ratio, produce a concrete that has improved flexural, tensile, and bond strength, lower modulus of elasticity, increased freeze-thaw resistance, and reduced permeability compared to conventional concrete of similar mix design.

  • PDF