• Title/Summary/Keyword: Combined Cycle Plant

Search Result 225, Processing Time 0.032 seconds

Development of Inter-Turn Short Circuits Sensor for Rotor Winding of Synchronous Generator (발전기 회전자의 층간단락 감지기 개발)

  • Nam, Jong-Ha;Lee, Seung-Hak;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.307-312
    • /
    • 2002
  • Inter-turn short circuits can have significant effects on a generator and its performance. The Inter-turn short circuits sensor for synchronous generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a shorted- turn test was performed at the Seoinchon combined cycle power plant on gas turbine generator and stim turbine generator. This sensor will be used as a detecting of Inter-turn short circuits for synchronous generator's field winding.

Estimation of Hydraulic Status on Intake Structure at Gunsan Combined Cycle Power Plant by Numerical and Physical Model Test (수치모의와 수리모형실험에 의한 군산복합화력발전소 냉각수 취수부 수리현상 검토)

  • Park, Byong-Jun;Song, Hyun-Ku;Hur, Young-Hwoe;Kang, Shin-Wook;Park, Young-Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1884-1888
    • /
    • 2009
  • 군산복합화력발전소의 냉각수 취수부는 부지 여건상 수로의 길이가 짧고, 좌안이 좁아진 후 단차가 있는 형태에 직각으로 흐름방향이 전환되면서 CWP로 유입되는 구조로 설계되었기 때문에 CWP 운영에 불리한 수리현상이 예상되어 수치모의와 수리모형실험을 통한 사전검증이 필요하였다. 이에 $FLOW-3D^(R)$를 이용한 3차원 수치모의와 축척 1/10의 수리모형실험을 통하여 면밀히 검토한 결과 CWP 진입부의 깊은 수심이 흐름을 감세하여 0.3m/s 이하의 유속분포를 나타내 균등취수에 문제가 없는 것으로 확인되었다.

  • PDF

The Performance and the NOx Emission Characteristics of the Combined Cycle Using Medium-Btu Coal Gas (중발열량 석탄 가스를 사용하는 복합발전 사이클의 성능 및 NOx 배출 특성)

  • Lee, Chan;Yun, Yong-Seong
    • Journal of Energy Engineering
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • 증발열량 석탄가스 연료를 사용하는 석탄가스와 복합 발전 플랜트의 성능 및 NOx 배출량을 동시에 예측하기 위한 모사 방법을 제시하였다. 본 방법은 복합 사이클의 열역학적 해석 기법을 토대로, 석탄가스화 복합발전 플랜트의 시스템 연계 및 석탄가스 연소에 의한 탈설계점 효과를 예측하는 모델들을 포함하고 있다. 본 방법에 의한 전산 모사 결과와 천연가스를 사용하는 복합발전소의 실제 시험 결과를 비교함으로써, 본 방법의 예측정확도를 검증하였다. 본 모사 방법을 이용하여, 서로 다른 4가지 석탄가스 연료에 대해, 공기 분리장치와의 다양한 연계 설계 조건에 따른 석탄가스화 복합발전 플랜트의 전체 성능, 운전 안전성 및 NOx 배출 특성들을 비교, 검토하였다.

  • PDF

Multi-Ejector Design for High Altitude Simulation (고고도 환경 모사를 위한 멀티 이젝터 설계)

  • NamKoung, Hyuck-Joon;Shim, Chang-Yol;Lee, Jae-Ho;Park, Sun-Sang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.705-708
    • /
    • 2011
  • Ejector system can induce the secondary flow or affect the secondary chamber pressure by both shear stress and pressure drop which are generated in the primary jet boundary. Ejectors are widely used in a range of applications such as a turbine-based combined-cycle propulsion system and a high altitude test facility for rocket engine, pressure recovery system, desalination plant and ejector ramjet etc. The primary interest of this study is to set up an design procedure on the configuration and operating condition of multi-ejector for the various high altitude simulation.

  • PDF

Numerical simulations on flow and particle behaviors in the upper part of a syngas cooler for IGCC (IGCC 합성가스 냉각기 상부의 열유동 및 입자거동 특성에 대한 전산해석 연구)

  • Park, Sangbin;Ye, Insoo;Ryu, Changkook;Kim, Bongkeun
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.147-148
    • /
    • 2012
  • The syngas produced from coal gasification is cooled down for gas cleaning by a syngas cooler that produces steam. Due to the presence of fly slag in the syngas, erosion, slagging and corrosion especially in the upper part of the syngas cooler may cause major operational problems. This study investigates the flow, heat transfer and particle behaviors in the syngas cooler of a 300MWe IGCC plant by using computational fluid dynamics. For various operational loads and geometry, the gas and particle flows directly impinged on the wall opposite to the syngas inlet, which may lead to erosion of the membrane wall. In the evaporate channels inside the syngas cololr, the particle flows were concentrated more on the outer channel where slagging becomes more serious. The heat transfer to the wall was mainly by convection which was larger on the side wall below the inlet level.

  • PDF

Development of Shorted-Turn Sensor for Generator Rotor (발전기 계자의 층간단락 감지기 개발)

  • Lee, Young-Jun;Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1765-1767
    • /
    • 2001
  • The shorted-turn sensor for generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a shorted-turn test was performed at the Seoinchon combined cycle power plant on gas turbine generator. This sensor will be used as a detecting of shorted-turn for generator's field winding.

  • PDF

Management of Combined Cycle Plant in Real-Time Economic Dispatch (실시간 경제급전 프로그램에서 복합화력 처리 방안)

  • Lee, Sang-Ho;Lee, Jeong-Ho;Oh, Tae-Kyoo;Kim, Ki-Woon;Lee, Jin-Soo;Seo, Eun-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.40-41
    • /
    • 2008
  • 본 논문에서는 한국형 통합 에너지관리시스템(K-EMS)용 발전계획 응용프로그램 중에서 경제급전(Economic Dispatch) 프로그램 개발의 상세 내용을 소개한다. 특히 복합화력에서 가스터빈(GT)과 스팀 터빈(ST)의 현재출력을 고려하여 등가복합화력기로 변환하여 경제배분에 포함시키는 방안 및 데이터 이상 또는 데이터 미비 처리 방안 등을 소개한다.

  • PDF

A Development of the integrated monitoring and control system for the combined cycle power plant (복합화력발전을 위한 통합감시제어 시스템 개발)

  • Lee, Bong-Kuk;Shin, Yong-Hak;Chun, Tae-Young;Lee, Seung-Joo;Lee, Kwang-Soon;Won, Wang-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1553-1554
    • /
    • 2008
  • 본 논문에서 복합 화력 발전을 위한 개방화 되고 표준화된 보일러/터빈 통합 감시제어 시스템을 개발하였고, 검증하였다. 통합 감시 제어 시스템은 복합 화력 공정의 HRSG, BOP, DEHC 계통을 위한 통합 감시 제어 시스템이다. 복합 화력 공정에서 시스템은 다양한 운전모드와 잦은 기동, 정지에 의해 운영되는 특징이 있다. 통합감시제어시스템은 복합모드 제어를 수행하고 고급제어를 포함하는 고기능제어 시스템으로 개발되었다. 타 시스템과의 효율적인 연계를 위해 표준화된 인터페이스의 개방형 시스템으로 개발하였으며, 원거리관리를 위한 Web monitoring 기능을 수행하고, 효율적인 실시간 이력 시스템을 포함한다. 개발된 시스템은 현장에서 실제로 검증되었다.

  • PDF

On-Line Diagnosis Method for Generator Rotor Windings (발전기 운전중 회전자 진단에 관한 연구)

  • Lee, Young-Jun;Kong, Tae-Sik;Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1846-1849
    • /
    • 2002
  • A shorted-turn test was performed at the Sininchon combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line diagnosis system. The flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

Noise Prediction of HRSG for Gas Turbine (복합발전용 배열회수보일러의 소음예측)

  • 남경훈;박석호;김백영;김원일
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1116-1122
    • /
    • 1999
  • HRSG, which is one of main components of the combined cycle power plant,is composed of an inlet duct, a main body and casing, an outlet duct and a stack. It is important to design HRSG wihtin the allowable noise limit. For this purpose, it is necessary to analyze and predict the noise reduction and radiation at HRSG. In this paper, the technology for the noise prediction at each part of HRSG has been based on the empirical and field data, and also the HRSG noise prediction program has been developed. In order to verify the developed technology and program a field test is conducted. The results of noise prediction show good agreement with the measured.

  • PDF