• Title/Summary/Keyword: Combine operation

Search Result 171, Processing Time 0.259 seconds

Combined Free Flaps in Reconstruction of Upper Extremity (결합 유리피판을 이용한 상지 복합결손의 재건)

  • Kim, Sug Won;Lee, June Bok;Lee, Sung Jun;Seul, Chul Hwan;Seo, Dong Wan
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • Advances in microvascular techniques and refinements in microsurgical tissue transfers have enabled surgeons to combine different tissue components and reconstruction into a single-stage operation in extensive or composite defect following injury. Some problems and consideration for extensive or composite defects are form, shape, function, and dimension of the defect sites. Therefore combination of two or more flaps is required to reconstruct extensive or composite defect. This paper presents our clinical experience of four cases of combined free flaps with or without sequential microanastomosis in reconstruction of upper extremity based on peroneal flowthrough, thoracodorsal, and dorsalis pedis vascular system. Satisfactory results were obtained without flap loss and complications. The free flaps were combined in th following fashion; two cases by bridge fashion, one by chimeric microanastomosis and one by simple chimeric fashion. The median follow-up time on all patients was 21.7 months. Donor site morbidity was minimal. Extensive soft tissue or composite defects can be effectively covered by various combined flaps. Even though the risk for complication exists, the options of combination with or without sequential microanastomosis can add a functional or sensory dimension to reconstruction of complex wounds.

  • PDF

Brightness Property of ICCP(Inductive Capacitive Coupled Plasma) for External Electrode Fluorescent Lamp (EEFL) (외부전극 형광램프를 위한 유도-용량형 플라즈마의 휘도특성)

  • Lee, Seong-Jin;Choi, Gi-Seung;Chai, Su-Gil;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1657-1658
    • /
    • 2006
  • An external electrode fluorescent lamps (EEFLs) have the advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Studies on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high brightness using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter. To solve these problems of CCFL, EEFL (External Electrode Fluorescent Lamp) is introduced. Because electrode of EEFL is on the outer surface of discharge tube, the electrode is perfectly prevented from the sputtering by accelerated ions. And it is possible to drive the many CCFLs at the same time, because EEFL shows the positively resistant characteristic. But EEFL has the large non-radiative power loss in sheath. In this study the novel electrode structure was introduced in order to reduce non-radiative power loss in sheath of EEFL. The novel electrode structure comes from the idea to combine conceptually capacitive discharge with inductive discharge. Thus, this study verifies the change in the optical characteristics according to the change in electrode structure through a Maxwell's electromagnetic field simulation and examines the relationship between the change in the EEFL electrode structure and brightness by measuring the optical characteristics.

  • PDF

Development of an Evaluation Procedure for Seakeeping Performance of High-speed Planing Hull using Hybrid Method (하이브리드 방법을 사용한 고속 활주정의 내항성능평가 절차 개발)

  • Kim, YoungRong;Park, Jun-Bum;Park, Jong-Chun;Park, Seul-Ki;Lee, Won-Min
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.3
    • /
    • pp.200-210
    • /
    • 2019
  • High-speed planing craft is generally smaller than commercial vessels, for which not only the roll motion but also the pitch and heave motions are relatively large during operation However, if seakeeping performance of high-speed planing craft is evaluated by assessment methods of commercial vessels considering roll damping only, it would get unreasonable results due to excessive magnitudes of motion. This research aims at developing a procedure to evaluate seakeeping performance of high-speed planing craft reasonably well by considering responses of roll, heave and pitch motions. In addition, we tried to combine advantages of the potential flow method and CFD in this procedure, a so-called hybrid method, which uses the 3D panel method for the analysis of seakeeping performance, and tunes the damping coefficient using CFD analysis at a specific frequency. Finally, we evaluated seakeeping performance of coastal rescue boat in operation by applying the proposed procedure, and analyzed the results referring to the seakeeping criteria.

Performance Analysis of QoS Mechanism Using DiffServ in IPOA Networks (IPOA 망에서 DiffServ를 이용한 QoS 메커니즘의 성능분석)

  • 문규춘;최현호;박광채
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.307-310
    • /
    • 2000
  • ATM is the switching and multiplexing technology chosen by the ITU-T for the operation of B-lSDN. Basically, ATM technology is designed to combine the reliability of circuit switching with the efficiency and flexibility of packet switching technology. For servicing QoS in IPOA(IP over ATM) when the larger effort is given, it will be the good method that the original QoS benefits having ATM switching have in ATM layer underlying layer. The IETF has recently proposed Differentiated Services framework for provision of QoS. In this paper we analyse performance of two Diffserv mechanism. Threshold Dropping and Priority Scheduling. Threshold Dropping and Priority Scheduling can be regarded as basic mechanisms from which the other mechanisms have been derived. Hence comparative performance of these two mechanisms in providing required QoS is an important issue. In this Paper we carry out a performance comparison of the TD and PS mechanisms with the aim of providing the same level of packet loss to the preferred flow. Our comparison of the TD and PS allows us to determine resultant packet loss for the non-preferred flows as a function of various parameters of the two mechanisms.

  • PDF

Vision-based Navigation for VTOL Unmanned Aerial Vehicle Landing (수직이착륙 무인항공기 자동 착륙을 위한 영상기반 항법)

  • Lee, Sang-Hoon;Song, Jin-Mo;Bae, Jong-Sue
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.226-233
    • /
    • 2015
  • Pose estimation is an important operation for many vision tasks. This paper presents a method of estimating the camera pose, using a known landmark for the purpose of autonomous vertical takeoff and landing(VTOL) unmanned aerial vehicle(UAV) landing. The proposed method uses a distinctive methodology to solve the pose estimation problem. We propose to combine extrinsic parameters from known and unknown 3-D(three-dimensional) feature points, and inertial estimation of camera 6-DOF(Degree Of Freedom) into one linear inhomogeneous equation. This allows us to use singular value decomposition(SVD) to neatly solve the given optimization problem. We present experimental results that demonstrate the ability of the proposed method to estimate camera 6DOF with the ease of implementation.

A Modified Single-Phase Transformerless Z-Source Photovoltaic Grid-Connected Inverter

  • Liu, Hongpeng;Liu, Guihua;Ran, Yan;Wang, Gaolin;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1217-1226
    • /
    • 2015
  • In a grid-connected photovoltaic (PV) system, the traditional Z-source inverter uses a low frequency transformer to ensure galvanic isolation between the grid and the PV system. In order to combine the advantages of both Z-source inverters and transformerless PV inverters, this paper presents a modified single-phase transformerless Z-source PV grid-connected inverter and a corresponding PWM strategy to eliminate the ground leakage current. By utilizing two reversed-biased diodes, the path for the leakage current is blocked during the shoot-through state. Meanwhile, by turning off an additional switch, the PV array is decoupled from the grid during the freewheeling state. In this paper, the operation principle, PWM strategy and common-mode (CM) characteristic of the modified transformerless Z-source inverter are illustrated. Furthermore, the influence of the junction capacitances of the power switches is analyzed in detail. The total losses of the main electrical components are evaluated and compared. Finally, a theoretical analysis is presented and corroborated by experimental results from a 1-kW laboratory prototype.

A New Zero-Current-Transition Buck Converter (새로운 영전류 천이형 벅 컨버터)

  • 최현칠
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.556-563
    • /
    • 2001
  • In this paper a new zero current transition pulse width modulation (ZCT-PWM) buck converter is proposed to combine the desirable feature of both the conventional buck converter and resonant converters. In this proposed scheme an auxiliary circuit is added to the conventional buck converter and used to achieve soft-switching for both the main switch and the freewheeling diode while not incurring any additional losses due to auxiliary circuit And this converter operates exactly like the conventional PWM converter except for a short particular time interval. The operation of the proposed converter is explained and analyzed. and design guidelines are presented. To validate the feasibility of the proposed converter, a 100KHz 180-W prototype is built and tested.

  • PDF

On Line Fault Diagnosis in the Large Power System (온라인 전력계통 고장 진단 시스템 개발)

  • Kim Jung-Nyun;Baek Sik-Young;Seo Gyul-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.5
    • /
    • pp.205-211
    • /
    • 2005
  • Recently, power system is getting larger and more complex. When the complex power system has a problem, it is very difficult even for the experts to find out where the problem is and to make a timely decision by operators. There have been many studies on these problems but the results are not good enough for applying to real power system. Therefore, power system operators always had to judge the exact state of power system and be preparative for the problems that can occur later. We developed new methods that can be applied to complex power system by dividing the system into small modules. By using 'module', we can combine small modules together to make complex power systems and the knowledge base that is applied to fault diagnosis system. As a result, compared to previously developed diagnosis products, operation time is shortened and the knowledge base is become simpler and clearer, which made online usage capable. This system can be used as a complementary measurement that helps the operator from making any mistakes.

Anticorit Prelube oils for sheet metal forming Lubricity joined to corrosion protection for steel mill and automotive press shop application

  • LOSCH A.;KUBICKI F.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.249-254
    • /
    • 2004
  • The pressing of car body parts is one of the most important sheet metal drawing processes. The corrosion protection oil applied by the steel mills plays a part in every sheet metal forming operation and also makes up the largest proportion of lubricants used. The idea to combine the corrosion protection properties of a corrosion preventive oil with the lubricity of a drawing oil lead to the development of the Anticorit prelubes. Applied at the finishing lines of the steel mills, they finally serve as lubricant in the press shops. A prerequisite for the suitability of a prelube-type oil is the absolute compatibility with all single processes from the coil to the Body in White. The use of prelubes in steel mills reduces the number and quantity of spot lubricants for additional press shop oiling dramatically. But their true benefits can only be fully achieved if the compatibility principle is applied throughout the manufacturing chain. Therefore, modem prelubes systems are modular, even different viscosities can be part of the same concept. This results in a far-reaching multifunctionality of the Anticorit prelube system for all applications.

  • PDF

Design Method for Flowing Water Purification with UV Lamp (UV램프를 이용한 유수처리형 살균장치의 설계방법)

  • Jung, Byung-Kyun;Lee, Jin-Jong;Jeong, Byeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.455-460
    • /
    • 2009
  • A number of factors combine to make ultraviolet radiation a superior means of water purification for ground water, rainwater harvesting systems and so on. Ultraviolet radiation is capable of destroying all types of bacteria. Additionally, ultraviolet radiation disinfects rapidly without the use of heat or chemical additives which may undesirably alter the composition of water. In a typical operation, water enters the inlet of a UV lamp and flows through the annular space between the quartz sleeve and the outside chamber wall. The irradiated water leaves through the outlet nozzle. Several design features are combined to determine the dosage delivered. The first is Wavelength output of the lamp, the Second is Length of the lamp - when the lamp is mounted parallel to the direction of water flow, the exposure time is proportional to the length of the lamp, the third is Design water flow rate - exposure time is inversely related to the linear flow rate, the forth is Diameter of the purification chamber - since the water itself absorbs UV energy, the delivered dosage diminishes logarithmically with the distance from the lamp. In this paper, It describe the how to design optimal UV disinfection device for ground water and rainwater. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method manufactured prototype applied to disinfection test and proved satisfied performance.