• 제목/요약/키워드: Column strength

검색결과 1,787건 처리시간 0.027초

Investigations on the behaviour of corrosion damaged gravity load designed beam-column sub-assemblages under reverse cyclic loading

  • Kanchanadevi, A.;Ramanjaneyulu, K.
    • Earthquakes and Structures
    • /
    • 제16권2호
    • /
    • pp.235-251
    • /
    • 2019
  • Corrosion of reinforcement is the greatest threat to the safety of existing reinforced concrete (RC) structures. Most of the olden structures are gravity load designed (GLD) and are seismically deficient. In present study, investigations are carried out on corrosion damaged GLD beam-column sub-assemblages under reverse cyclic loading, in order to evaluate their seismic performance. Five GLD beam-column sub-assemblage specimens comprising of i) One uncorroded ii) Two corroded iii) One uncorroded strengthened with steel bracket and haunch iv) One corroded strengthened with steel bracket and haunch, are tested under reverse cyclic loading. The performances of these specimens are assessed in terms of hysteretic behaviour, energy dissipation and strength degradation. It is noted that the nature of corrosion i.e. uniform or pitting corrosion and its location have significant influence on the behaviour of corrosion damaged GLD beam-column sub-assemblages. The corroded specimens with localised corrosion pits showed in-cyclic strength degradation. The study also reveals that external strengthening which provides an alternate force path but depends on the strength of the existing reinforcement bars, is able to mitigate the seismic risk of corroded GLD beam-column sub-assemblages to the level of control uncorroded GLD specimen.

각형 강관의 축방향 압축강도에 관한 연구 (Axial Compressive Strength of Rectangular Hollow Section Members)

  • 조재병;임정순;한충성
    • 한국강구조학회 논문집
    • /
    • 제10권2호통권35호
    • /
    • pp.153-160
    • /
    • 1998
  • 각형 강관(${\boxe}-75{\times}75{\times}3.2,\;{\boxe}-100{\times}100{\times}4.2,\;{\boxe}-125{\times}125{\times}6.0$) 기둥의 단면 치수와 초기 변형을 측정하였다. 인장시험, 단주 압축강도 실험, 그리고 세장비 $46{\sim}84$ 사이의 기둥에 대한 압축강도 실험을 수행하였다. 유한요소법에 의한 기둥의 압축 강도를 산출하였다. 단면의 공칭 치수에 대한 측정값의 오차는 무시할 정도이며, 초기변형은 각 단면별로 세장비 100에 해당하는 기둥길이에 대해 초과 확률 2.5% 값이 각각 1/490, 1/1121, 1/1395로 나타났다. 인장시험 결과 강재의 항복강도는 최소 규정 강도보다 30% 이상 높다. 기둥 실험 결과 얻은 각형 강관 기둥의 압축강도는 단주 압축강도를 강재의 항복강도로 간주하고 비교하면 유한요소 해석 결과나 AISC, Eurocode의 강도 곡선과 거의 같거나 약간 높은 값이나, 강재의 최소 규정강도를 기준으로 비교하면 실험 결과가 훨씬 높은 강도를 보이는 것으로 나타났다.

  • PDF

고강도 콘크리트를 사용한 보-기둥 접합부의 비 선형 거동에 관한 기초적 연구 (A Fundmental Study of the Inlastic Behavior of High Strength Concrete Beam-Column Joints.)

  • 민정규;박현수;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.51-56
    • /
    • 1990
  • Six small-scale reinforced concrete beam-column joint specimens subjected to monotonic and cyclic loading were tested to investigate the effects of strength of concrete. Variables are 1)compressive strength of concrete(f' c=300, 700kg/㎠), 2)shear span to depth ratio (a/d=4.7, 2.0). The major results of this test were: 1)flexural strength of high strength concrete beam-column joint was not affected too much by the compressive strength of concrete, 2) flexural cracks emerge to inside of beam deeply for high strength concrete member.

  • PDF

고강도 재료를 사용한 외부 보-기둥-슬래브 접합부의 지진응답 (Seismic Response of Exterior Beam-Column-Slab connection using High-Strength Materials)

  • 장극관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.343-350
    • /
    • 1999
  • The purpose of this study is to compare the response of the high-strength concrete beam-column-slab subassembly with the response of a normal-strength concrete specimens. Four assemblies were designed 2/3 scale beam-column-slab joint(fc'=240kg/cm2 fc'=700kg/cm2) and tested to investigate seismic behaviour. From the test results 1) flexral cracks emerge to inside of bean deeply for high strength concrete member 2) the high-strength specimens represented stable hysteretic behaviour for the displacement ductility 5.5 but degradation in stiffness and strength and unstable hysteretic behaviors were observed owing to the brittleness of high-strength concrete beyond its range.

  • PDF

Buckling Strength Analysis of Box-Column Including the Coupling Effect Between Local and Global Buckling

  • Paik, Jeom-K.
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1988년도 가을 학술발표회 논문집
    • /
    • pp.36-42
    • /
    • 1988
  • In this study, a formulation of the idealized plate element based upon the idealized structural unit method(ISUM) firstly proposed by Ueda et.al is made in an attempt to analyze the geometric nonlinear behaviour up to the buckling strength of thin-walled long structures like box-column structure including the coupling effect between local and global buckling. An application to the example box-column is also performed and it is found that the present method gives reliable results with consuming very short computing times and therefore is very useful for evaluation of the buckling strength of thin-walled long structures.

  • PDF

고강도 콘크리트를 사용한 플랫 플레이트 구조의 기둥·슬래브 접합부 구조성능 (Structural Performance of Column-Slab Connection in Flat Plate System Using High Strength Concrete)

  • 김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.97-105
    • /
    • 2006
  • 플랫 플레이트 구조에서 고강도 콘크리트를 사용함에 따라서 접합부의 전단강도와 같은 구조성능을 향상시켜서 플랫 플레이트 구조의 단점을 보완하여 장점을 극대화시킬 수 있다고 판단된다. 이에 본 논문에서는 70MPa급 고강도 콘크리트를 사용한 플랫 플레이트구조의 기둥 슬래브 접합부 실험체를 제작한 후에 수직하중과 수평하중의 조합하중을 가력하여 플랫 플레이트구조의 기둥 슬래브 접합부에 대한 전단강도를 비롯한 주요한 구조성능을 평가하고자 한다. 본 연구에서의 실험변수는 슬래브의 철근비와 슬래브에 작용하는 수직하중의 비율로 하였다.

고장력(SM570) 강재의 기둥재 특성에 관한 연구 (A Study on the Characteristics of High Tensile Strength Steel (SM570) Plates in Beam-Column Members)

  • 임성우;장인화
    • 한국강구조학회 논문집
    • /
    • 제15권1호
    • /
    • pp.9-15
    • /
    • 2003
  • 최근 건축물의 고층화 및 장스팬화 됨에 따라서 부재단면이 점차 증대되서 용접시공 등이 어려워지고 있다. 이에 대한 해결방안의 하나로 고강도강을 사용하면 부재단면을 감소시킬 수 있다. 고강도강의 주 사용 부위은 높은 축력을 받는 기둥재이다. 휨모멘트와 축력을 동시에 받는 박스형 및 H형 단면을 갖는 고강도 기둥부재의 성능실험을 축력과 세장비를 변수로 수행하였다. 실험 결과 기둥부재의 최대내력이 허용응력도 설계법과 한계상태 설계법을 모두 만족하였다.

A new statistical approach for joint shear strength determination of RC beam-column connections subjected to lateral earthquake loading

  • Kim, Jaehong;LaFavet, James M.;Song, Junho
    • Structural Engineering and Mechanics
    • /
    • 제27권4호
    • /
    • pp.439-456
    • /
    • 2007
  • Reinforced concrete (RC) joint shear strength models are constructed using an experimental database in conjunction with a Bayesian parameter estimation method. The experimental database consists of RC beam-column connection test subassemblies that maintained proper confinement within the joint panel. All included test subassemblies were subjected to quasi-static cyclic lateral loading and eventually experienced joint shear failure (either in conjunction with or without yielding of beam reinforcement); subassemblies with out-of-plane members and/or eccentricity between the beam(s) and the column are not included in this study. Three types of joint shear strength models are developed. The first model considers all possible influence parameters on joint shear strength. The second model contains those parameters left after a step-wise process that systematically identifies and removes the least important parameters affecting RC joint shear strength. The third model simplifies the second model for convenient application in practical design. All three models are unbiased and show similar levels of scatter. Finally, the improved performance of the simplified model for design is identified by comparison with the current ACI 352R-02 RC joint shear strength model.

고강도 콘크리트를 사용한 철근콘크리트 외부 보-기둥 접합부의 거동 평가 (Evaluation of Structural Behavior of Reinforced Concrete Exterior Beam-Column Joints with High-Strength Concrete)

  • 이범식;김경덕;김상우;김길희;이정윤
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권6호
    • /
    • pp.72-81
    • /
    • 2014
  • 이 논문은 고강도 콘크리트를 사용한 철근콘크리트 외부 보-기둥 접합부의 실험결과를 보고한 것이다. 실험체의 주요 실험변수는 접합부 파괴모드, 콘크리트 압축강도, 철근의 정착 방법이다. 모든 실험체는 ACI 352R-02 기준에 바탕을 두어 J파괴와 BJ파괴가 되도록 계획하였다. 주철근은 90도 표준갈고리로 하거나 확대머리철근으로 하였다. 실험결과는 콘크리트 압축강도에 제한되는 현행 ACI 설계 기준식이 고강도 콘크리트를 사용한 보-기둥 접합부의 강도를 다소 과소평가하고 있음을 보여준다. 또한 확대머리철근을 가진 J파괴형 보-기둥 접합부의 강도는 표준갈고리를 가진 접합부보다 약 10% 이상 높게 평가되었다.

콘크리트강도 및 단면특성에 따른 콘크리트 충전강관(CFT) 기둥의 극한강도 분포에 관한 실험적 연구 (An Experimental Study on Distribution of Ultimate Strength of Concrete-Filled Steel Tube Columns according to Concrete Strength and Section Properties Ratio)

  • 장갑철;장경호
    • 한국공간구조학회논문집
    • /
    • 제8권5호
    • /
    • pp.59-65
    • /
    • 2008
  • 최근, 교량교각과 같은 기둥구조물의 사용성능을 향상시킴과 동시에 복잡한 도심지 내 효율적 공간활용을 위해 콘크리트 충전강관(CFT: concrete-filled steel tube)의 적용이 점차 증가하고 있다. 이러한 기둥구조물의 정확한 설계를 위해서는 재료 및 기하학적 특성에 따른 콘크리트 충전강관 기둥의 거동에 관한 실험적 연구가 요구된다. 이에 본 연구에서는 압축강도실험을 통하여 외경-두께비 (D/t) 및 강재-콘크리트 단면적비 (As/Ac)에 따른 콘크리트 충전강관 기둥의 극한강도 분포특성에 대해 명확히 파악하였다. 또한 콘크리트 배합강도에 따른 콘크리트 충전강관 기둥의 극한강도 분포특성을 실험을 통하여 명확히 파악하였다. 실험결과의 고찰을 통하여 압축하중을 받는 콘크리트 충전강관 기둥의 극한강도는 콘크리트 강도보다 강과의 단면특성에 주로 의존함을 알 수 있었다.

  • PDF