• Title/Summary/Keyword: Column size

Search Result 758, Processing Time 0.034 seconds

Evaluation of Granular Activated Carbon Process Focusing on Molar mass and size distribution of DOM (DOM의 분자량과 크기분포에 따른 입상활성탄 공정의 평가)

  • Chae, Seon H.;Lee, Kyung H .
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.31-38
    • /
    • 2008
  • The primary objective of this study was to evaluate the variation of the molecular size distribution by granular activated carbon (GAC) adsorption. GAC adsorption was assessed by using the rapid small-scale column test (RSSCT) and high-performance size-exclusion chromatography (HPSEC) was used to analyze the molecular size distribution (MSD) in the effluent of GAC column. RSSCT study suggested that GAC adsorption exhibited excellent interrelationship between dissolved organic carbon (DOC) breakthrough and MSD as function of bed volumes passed. After GAC treatment, the nonadsorbable fraction which was about 25percents of influent DOC corresponded to the hydrophilic (HPI) natural organic carbon (NOM) of NOM fractions and was composed entirely of <300 molecular weight (MW) in the HPSEC at the initial stage of the RSSCT operation. The dominant MW fraction in the source water was 1,000~5,000daltons. At the bed volumes 2,500, MW <500 of GAC treated water was risen rather than it of source water. After the bed volumes 7,300 of operation, the MW 1,000~3,000 fraction was closed to about 80percents of DOC found in the GAC influent. The Number-average molecular weight (Mn) value determined using HPSEC for the effluent of GAC column was gently increased as DOC breakthrough progress. The quotient p(Mw/Mn) can be used to estimate the degree of polydispersity was shown greatest value for the GAC effluent at the initial stage of the RSSCT operation.

Experimental Design of Column Flotation for Recovery of High Grade Molybdenite (고품위 몰리브덴 회수를 위한 컬럼부선 요인설계)

  • Hyun Soo Kim;Purev Oyunbileg;Chul-Hyun Park
    • Resources Recycling
    • /
    • v.32 no.6
    • /
    • pp.34-44
    • /
    • 2023
  • In this work, column flotation using factorial design was performed for recovering high-grade molybdenite concentrate. First, the flotation concentrate from Samyang Mining Plant was regrinded to a mean size of 165, 116, 46.7, and 38.4 ㎛ for an increase of the liberation degree. Tests were carried out for various variables affecting column flotation, and then the concentrates with molybdenite grade and recovery of 98.3 % and 95.28 % were obtained, respectively. Also, regression was performed using the statistical analysis program (SPSS 25) with the factorial design and experimental data on particle size, flow wash-water velocity and depressant that affect high grade. From the results, a model equation was derived to predict the molybdenite grade (MG) and recovery (MR) with the relationship between column flotation variables. Factors such as depressant concentration + wash-water velocity and particle size + depressant concentration + wash-water velocity were smaller than the significance level (0.05) and had a significant effect on the dependent variable, grade, and in the recovery model, only particle size and wash-water velocity factors affected the dependent variable, recovery.

The Growth of Transgenic Tobacco′s Suspension Culture and the Production of β-Glucuronidase in Bubble Column Bioreactor (Bubble column bioreactor에서 형질전환된 담배세포의 성장양상 및 β-Glucuronidase의 생산)

  • 김석우;이동근;현진원;이상현;하종명;하배진;이재화
    • Journal of Life Science
    • /
    • v.12 no.5
    • /
    • pp.577-583
    • /
    • 2002
  • The growth kinetics and the production of $\beta$-glucuronidase from transgenic tobacco's suspension culture was investigated in the flask culture and a 2.5 L bubble column reactor. The growth of bubble column reactor was similar to that of flask culture. However, in the bubble column reactor, the production of $\beta$ -glucuronidase reached 2850 U/mg (85-fold higher than that of flask culture). In both case, the production level of $\beta$ -glucuronidase was fluctuated, which was resulted from periodical degradation of the protein. Sucrose is important component in plant culture medium. Twice addition of sucrose in bubble column reactor could not improve cell growth, since other components in a medium were already depleted. However, the addition of sugar decreased cell size, which facilitated the operation of bioreactor. The production of $\beta$ -glucuronidase was continuously increased, however final concentration of $\beta$ -glucuronidase was similar to that without sucrose addition.

Column cleaning, regeneration and storage of silica-based columns (실리카 기반 컬럼의 세척, 재생 및 보관 가이드)

  • Matt James;Mark Fever
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.1.1-1.4
    • /
    • 2024
  • This article provides comprehensive guidance on the maintenance, cleaning, regeneration, and storage of silica-based HPLC (High-Performance Liquid Chromatography) columns. The general considerations emphasize the importance of using in-line filters and guard cartridges to protect columns from blockage and irreversible sample adsorption. While these measures help, contamination by strongly adsorbed sample components can still occur over time, leading to an increase in back pressure, loss of efficiency, and other issues. To maximize column lifetime, especially with UHPLC (Ultra-High Performance Liquid Chromatography) columns, it is advisable to use ultra-pure solvents, freshly prepared aqueous mobile phases, and to filter all samples, standards, and mobile phases. Additionally, an in-line filter system and sample clean-up on dirty samples are recommended. However, in cases of irreversible compound adsorption or column voiding, regeneration may not be possible. The document also provides specific recommendations for column cleaning procedures, including the flushing procedures for various types of columns such as reversed phase, unbonded silica, bonded normal phase, anion exchange, cation exchange, and size exclusion columns for proteins. The flushing procedures involve using specific solvents in a series to clean and regenerate the columns. It is emphasized that the flow rate during flushing should not exceed the specified limit for the particular column, and the last solvent used should be compatible with the mobile phase. Furthermore, the article outlines the storage conditions for silica based HPLC columns, highlighting the impact of storage conditions on the column's lifetime. It is recommended to flush all buffers, salts, and ion-pairing reagents from the column before storage. The storage solvent should ideally match the one used in the initial column test chromatogram provided by the manufacturer, and column end plugs should be fitted to prevent solvent evaporation and drying out of the packing bed.

  • PDF

An Experimental Study on the Mock-up test take advantage of the High Strength Concrete (초고강도 콘크리트를 이용한 CFT실물대 실험)

  • Son Young Jun;Kim Jae Eun;Yang Dong Il;Jung Keun Ho;Lim Nam Gi;Jung Sang Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.458-461
    • /
    • 2004
  • The column for Steel Framed Reinforced Concrete Structure (SFRCS) and the column for Reinforced Concrete Structure (RCS) could be the most common building structure. The increasing of the need for massive space hasaffected the size of building components for supporting the massive structure. However, the changing of components size makes inefficient space of building. Hence. to meet the need for acquiring efficient space comparing the budget and cost the new structure method, Concrete Filled Tube Steel (CFT), was developed. CFT is the structure for which steel tube instead of other materials such as wood for holding concrete is used. The most benefit of this one is to help in reducing the size of the building components and local buckling because of tube steel holding concrete. For this reason, this research will examine the probability of applying CFT on construction sites by using the concrete $(800kg/cm^2)$ especially for CFT through the data from the real size mock-up.

  • PDF

Seismic Evaluation of Exposed Column-base Plate Weak-axis Connections Using L-shaped Hooked Anchor Bolts (L형 갈고리 앵커볼트를 사용한 약축방향 노출형 주각부의 내진성능 평가)

  • Lim, Woo-Young;You, Young-Chan
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.4
    • /
    • pp.269-280
    • /
    • 2017
  • In this study, seismic performance was evaluated for the exposed column-base plate weak-axis connections of small size steel structures through cyclic loading tests. The primary test parameters are the thickness of base plate, the presence of rib plates, the number of anchor bolts and embedment length of anchor bolts. To investigate the effect of bond performance of anchor bolts on the seismic performance of column-base plate connections, L-shaped round bars and thread bars were used as the hooked anchor bolts in the test specimens. Test results showed that bond performance of anchor bolts and the thickness of base plate significantly affect the structural performance and energy dissipation capacity. In particular, it was found that even if the requirements for minimum thickness of the base plate that is satisfied, the base plate can yield before the capacity of steel column reaches the plastic moment resulting in decreasing the structural performance of the connections. However, the proposed details of the connections might be considered as the partially restrained, that is semi-rigid connections. Consequently, the L-shaped thread anchor bolts is applicable in the exposed column-base plate weak-axis connections of small-size steel structures.

Retention Behavior of Organic Compounds on Reversed-Phase Column expected by Van der Waals Volume (Van der Waals Volume을 이용한 역상 컬럼에서의 유기화합물들의 용출거동)

  • Park, Wun-Kyu;Lee, Yong-Moon;Moon, Dong-Cheul;Kang, Jong-Seong
    • Analytical Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.383-390
    • /
    • 1993
  • Retention behaviors of aliphatic and aromatic compounds were investigated with Van der Waals volume which represented the molecular size. The organic solvents, methanol, acetonitrile and tetrahydrofuran, were mixed with water at various ratio, respectively. The selectivity of organic solvents were tested by change of column temperature. The capacity factor was increased linearly according to the enlargement of molecular size. Therefore, Van der Waals volume was useful to predict the elution of organic molecules in reversed-phase column. The order of elution capacity of solvents was methanol

  • PDF

Separation of X- and Y-Bearing Spermatozoa III. Separation of bull spermtozoa by Sephadex Gel Filtration (X-정자와 Y-정자의 분이에 관한 연구 III. Sephadex Gel 여과에 의한 우정자의 분이)

  • 이주영;엄기붕;고대환;김종배;정길생
    • Korean Journal of Animal Reproduction
    • /
    • v.12 no.1
    • /
    • pp.24-30
    • /
    • 1988
  • These experiments were carried out to develop new techniques for In Vitro separatin of X-and Y-bearing spermatozoa. The bull semen was applied to the various Gel-Columns filled with swellen Sephadex G-50 Fine and then elutriated wtih Locke solution (elutriation rate; 1ml/3-4min., 1ml/1-2min.). Elutriated solution was fractionated into 1ml by automatic Fraction Collector and spermatozoa included in each fraction were subjected to the estimation of viability and recovery rate, and to B-body test. The results obtained in these experiments were summarized as follows: 1. When the column size and the elutriation rate were adjusted to 15$\times$1.6cm and 1ml/3-4min., respectively, the highest sperm concentration was obtained from the 8th to the 12th fraction. 2. As a trend, the viability of spermatozoa was improved by chromatography, and the degree of improvement ranged 5 to 10 percentage. 3. The average recovery rate of spermatozoa applied to column was 73.2 percentage and ranged 52.6 to 81.3 percentage. 4. The lowest rate of B-body bearing spermatozoa following chromatography was obtained when the column size and the elutriation rate were adjusted to 15$\times$0.8cm and 1ml/1-2min., respectively.

  • PDF

Experimental study on vacuum preloading with flocculation for solid-liquid separation in waste slurry

  • Wu, Yajun;Kong, Gangqiang;Lu, Yitian;Sun, De'an
    • Geomechanics and Engineering
    • /
    • v.13 no.2
    • /
    • pp.319-331
    • /
    • 2017
  • This vacuum preloading combined with polyacrylamide (PAM) flocculation was proposed to separating solid-liquid in waste slurry and to improving bearing capacity of soft soil ground. By using waste slurry taken from drilled shaft construction site in Shanghai, China, a series of settling column tests with four typical flocculants and one normal for waste slurry were carried out for comparative analysis. The optimal amounts for each flocculant were obtained from the column tests. Then, model tests on vacuum preloading with anionic polyacrylamide (APAM) flocculation and without flocculants were carried out. The out of water and the settlement of slurry surface ground were monitored during the model tests, and the changes in water content, particle-size and pore-size distributions in different positions after the model tests were measured and discussed. It is found that water content of the waste slurry without APAM flocculation changed from 204 to 195% by 24 hours standing and 15 hours vacuum preloading, while the water content of the waste slurry with APAM flocculation was declined from 163 to 96% by 24 hours standing, and was further reduced into 37% by 136 hours vacuum preloading, which shows that the combined method is feasible and effective.

A column study of effect of filter media on the performance of sand filter

  • Kim, Tae-hoon;Oh, Heekyong;Eom, Jungyeol;Park, ChulHwi
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.247-255
    • /
    • 2020
  • Sand filter is a key unit process for particle removal in water purification treatments. Its long-standing use is due to on-site customized retrofit. Proper selection of filter media is one of the retrofit approaches to improve filter performance. This study described a series of controlled laboratory column tests and examined the effects of media property on filtration and backwash. When sand media of 0.51 mm in effective size was replaced by sand of 0.60 mm, the filter run increased up to 5 times in the given bed depth. The change of media property required an increase of backwash rate by 0.05 m/min to satisfy the requirement of bed expansion, more than 20%. When the anthracite was changed with lower effective size and uniformity coefficient, correlation with sand in the filter bed could be satisfied within the permissible error between media and bulk characteristics. Besides, this selection resulted in a well-stratified configuration of media layers after bed expansion. The column study showed that the correlation of property between the dual media had a significant effect on the filter productivity and backwash interval.