• 제목/요약/키워드: Column section shape

검색결과 83건 처리시간 0.021초

플랫플레이트-기둥 접합부 강도발현에 관한 연구 (A Study on Strength of Flat Plate-Column Connections)

  • 강수민;이도범;김욱종;이지웅;박홍근;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.213-216
    • /
    • 2005
  • A numerical analysis was performed for interior connections of continuous flat plate to analyze the effect of design parameters such as column section shape, gravity load and slab span on the behavioral characteristics of the connections. Through the parametric study, the variations of shear stress distribution around the connection were investigated. According to the result of numerical analysis, as the length of the cross section of column in the direction of lateral load increases and gravity load increases, the effective area and the maximum shear strength providing the torsional resistance decrease considerably. And as the slab span loaded with relatively large gravity load increases, the negative moment around the connection increases and therefore the strength of connection against unbalanced moment decreases.

  • PDF

yLRC 합성기둥의 압축강도에 관한 실험 연구 (Experimental Study on the Compressive Strength of yLRC Composite Columns)

  • 김형근;김명한;조남규;김상섭;김상대
    • 한국강구조학회 논문집
    • /
    • 제21권5호
    • /
    • pp.545-552
    • /
    • 2009
  • 이 연구에서는 y형강판과 L형강으로 기둥의 외부를 구성하고 내부에 콘크리트를 타설하여 완성하는 yLRC (Reinforced Concrete with y-shape steel sheets and L-shape steel angles) 합성기둥에 대한 기초적인 실험을 수행하였다. yLRC 합성기둥은 철골과 콘크리트의 합성작용으로 단면성능이 우수하고, 거푸집 공사와 배근 공사를 생략할 수 있으므로 공기단축과 시공성 향상에도 상당한 효과를 나타낼 것으로 예상된다. L형강의 폭-두께비가 압축강도에 미치는 영향을 분석하기 위해서 L형강의 폭-두께비를 실험변수로 하는 6개의 실험체 (축소실험체 3개 및 실대실험체 3개)를 제작하고, 이 실험체에 대하여 중심축하중 실험을 수행하였다. 실험결과를 바탕으로 yLRC 합성기둥의 압축거동 및 압축강도에 대한 역학적인 특성을 분석하였다.

2축 편심 축하중을 받는 직사각형 고강도 RC기둥의 거동에 대한 실험적연구 (An Experimental Study in Rectangular High Strength Concrete Columns under Both Axial Load and Biaxial Bending)

  • 이종원;조문희;한경돈;유석형;반병열;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.209-214
    • /
    • 2001
  • Most reinforce concrete Columns of Building structure are subjected to both axial load and biaxial bending. However, It is hard to estimate the moment capacity of biaxial bending by exact solution. Thus, columns under biaxial bending are designed by approximate methods in practice. The purpose of this study is to compare experimental result with approximate methods and exact solution by computer. Parameters of the present test are compressive strength of concrete (350, 585, 650kgf/$\textrm{cm}^2$) and shape ratio of rectangular section. Ultimately, an experimental shape factor for rectangular RC column section is obtained through the test program. The shape of load contour is dominated by this shape factor obtained experimentally. So, reasonable design of RC columns subjected to both axial compression and biaxial bending depends on load contour.

  • PDF

Wall Column을 적용한 플랫플레이트 접합부 강도발현에 관한 연구 (A Study on Strength of Plat-Plate Wall-Column Connections)

  • 이도범;박홍근;이리형
    • 콘크리트학회논문집
    • /
    • 제18권2호
    • /
    • pp.257-266
    • /
    • 2006
  • 최근 공기단축, 낮은 층고, 자유로운 평면계획 등의 많은 장점을 가지는 플랫플레이트 구조형식이 고층주거건물의 구조형식으로 많이 사용되고 있다. 특히 국내에서 건설되고 있는 플랫플레이트 구조시스템은 횡력에 대한 저항성을 크게 하기 위하여 기둥의 단면이 매우 크며 직사각형 형태를 가지는 벽기둥(wall-column)을 사용하는 경우가 많으므로 접합부 강도산정모형에서는 이러한 기둥의 형태적 요소를 적절히 반영해야 한다. 기둥단면형상에 따른 플랫플레이트-기둥 접합부의 거동특성을 분석하기 위하여 기존의 강도모델을 검토하고 비선형 유한요소해석을 실시하였다. 기존 강도모델은 위험단면에서의 전단응력분포를 가정함에 있어서 기둥단면형상의 영향을 고려하지 못하여 플랫플레이트-기둥 접합부의 강도를 정확하게 예측하지 못하였다. 비선형 유한요소해석 결과, 하중가력방향과 평행한 기둥폭이 길어질수록 위험단면 측면에서 비틀림 전단을 받는 유효영역과 측면 최대전단강도가 줄어들어 접합부의 강도가 큰 폭으로 감소한다. 따라서 플랫플레이트-기둥 접합부의 강도를 정확히 산정하기 위해서는 하중가력방향과 평행한 기둥폭의 길이($c_1$)이 접합부 거동에 미치는 영향을 적절히 반영해야 할 것이다.

2-Seam 냉간성형 각형 CFT 기둥-보 내다이아프램 접합부의 구조성능에 관한 연구 (Study on Structural Performance of Two Seam Cold-Formed Square CFT Column to Beam Connections with Internal Diaphragm)

  • 오헌근;김선희;최영환;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제3권4호
    • /
    • pp.27-37
    • /
    • 2012
  • The construction of a moment connection for a rectangular hollow section (RHS) column and a H-shaped beam is difficult because the RHS is a closed section. When a inner diaphragm is used for such a connection, in general, it is installed after cutting the HSS columns, which results in increased construction work. This paper suggests a new fabrication method to overcome such problems: An inner diaphragm is welded to inside a C-shaped section first, and then a column is fabricated by welding two C-shaped sections. This fabrication method is superior to a classic method in terms of constructibility. An experimental and a numerical study using Ansys 9.0 were performed in order to compare the strength of connections with respect to the presence of concrete, the corner shape of diaphragm, and the axis of loading. The experimental results including initial stiffness and ultimate loads are reported and the analytical results including load transfer mechanism, degree of stress concentration, and strain distribution are also reported.

2심 냉간성형 각형 CFT기둥-보 접합부의 구조거동 (Structural Behavior of Two-Seam Cold Formed Square CFT Column to Beam Connections)

  • 오헌근;김선희;박찬면;최성모
    • 한국공간구조학회논문집
    • /
    • 제12권4호
    • /
    • pp.81-90
    • /
    • 2012
  • The concrete-filled tube (CFT) column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. Its Solution, 2 members of ㄷchennel in which Internal diaphragm is installed were welded beforehand and the method of making Rectangular Steel Tube was proposed. According to upside and downside junction shape, Internal diaphragm suggested as symmetric specimen and asymmetric specimen. The upper and lower diaphragm of the Symmetric specimen used the same horizontal and The upper diaphragm of the Asymmetric specimen used the horizontal plate and the lower diaphragm used the vertically plate. In this research, 4 T-shape column to beam steps connections were tested with cyclic loading experiment in order to evaluate the structural capability of the offered connection. Symmetric specimens be a failure in 0.03rad from beam flange. And Asymmetric specimens be a failure in 0.05rad from column interface. The comparison results of All specimens shown similar to energy absorption capacity in 0.02rad.

콘크리트채움 U형 강재보 - 콘크리트 기둥 접합부의 내진성능 (Seismic Resistance of Concrete-filled U-shaped Steel Beam-to-RC Column Connections)

  • 황현종;박홍근;이철호;박창희;이창남;김형섭;김성배
    • 한국강구조학회 논문집
    • /
    • 제23권1호
    • /
    • pp.83-97
    • /
    • 2011
  • 본 논문에서는 콘크리트 채움 U형 강재보와 철근콘크리트 기둥으로 구성된 접합부의 내진 상세를 개발하였다. 접합부 내진성능을 평가하기 위하여 세 개의 보-기둥 접합부 실험체를 반복주기하중에 대하여 실험하였다. 보춤과 기둥 단면 형상을 실험 변수로 하였다. 합성보의 춤은 슬래브 두께를 포함하여 610mm, 710mm이며, 철근콘크리트 기둥은 사각단면과 원형단면이 사용되었다. 접합부를 보강시키기 위하여 사각단면 기둥과 원형단면 기둥에 각각 대각 철근과 외다이어프램 강판을 사용한 특수 상세가 사용되었다. 실험 결과 실험체는 강도와 변형능력, 에너지 소산에 있어서 우수한 성능을 보여주었다. 변형능력은 특수모멘트골조 기준인 4% 이상의 층간변위각을 발휘하였다.

축력과 모멘트를 받는 H형강 주각부의 거동에 관한 해석적 연구 (An analytical study on the structural behavior of H shape column base plates under axial loads and moments)

  • 김정현;이승준
    • 한국강구조학회 논문집
    • /
    • 제17권2호통권75호
    • /
    • pp.217-225
    • /
    • 2005
  • 본 연구에서는 축력과 모멘트를 받는 H형강 주각부의 거동에 대해 조사하였다. 주각부의 거동을 분석하기 위하여 유한요소해석법을 이용하였으며 주각부의 해석적 모델을 도출하고자 하였다. 6개의 시험체에 대하여 축력비와 앵커볼트 크기, 베이스플레이트의 두께를 변수로 두고 각각의 거동을 알아보고자 하였으며 H형강 주각부의 실험결과와 유한요소해석결과 그리고 해석적 모델을 상호 비교하였다. 또한 일반적으로 축력과 모멘트를 받는 베이스플레이트의 설계에서 가정하는 지압응력과 유한요소해석에 의한 베이스플레이트의 지압응력의 분포를 비교하였다. 연구결과를 비교한 결과 주각부의 거동을 나타내는 초기강성과 항복하중은 유사하게 나왔으며, 지압응력은 베이스플레이트의 두께가 얇을수록 기둥의 하단에 집중되는 현상을 보였다.

Stiffener configurations of beam to concrete-filled tube column connections

  • Dessouki, Abdelrahim K.;Yousef, Ahmed H.;Fawzy, Mona M.
    • Steel and Composite Structures
    • /
    • 제17권1호
    • /
    • pp.83-103
    • /
    • 2014
  • The objective of this research is to study the ultimate moment capacity of the connections between steel I-beams and concrete-filled steel tube columns using different stiffener configurations. The main parameters considered are column cross section shape, square or circular, and filling the column with concrete. This analytical study includes finite element models using ANSYS program taking geometric and material nonlinearities into consideration. These models are verified against the experimental results obtained from previous researches and current design guides. The results show that using proper stiffener configuration affects the stress distribution through the connection and increases the ultimate moment capacity of the connections. Also, circular column is advantageous than the square column for all stiffener configurations and dimensions.

착색단고추 재배용 1-2W형 개조온실 구조의 안정성 검토 (Structural Safely Analysis of a Modified 1-2W Type Greenhouse Enhanced for Culturing Paprika)

  • 서원명;최만권;배용한;이종원;윤용철
    • 생물환경조절학회지
    • /
    • 제17권3호
    • /
    • pp.197-203
    • /
    • 2008
  • 본 연구는 1-2W형 온실의 구조를 개조하여 착색단 고추 재배온실로 이용하고 있는 온실의 구조의 안정성을 검토하였다. SAP-2000에 의한 구조해석 결과 1-2W기본형 온실의 기둥을 1.2m높였을 경우, 구조물이 견딜 수 있는 한계적설심은 변화는 거의 없으나 한계풍속은 약 $26.0\sim41.0m/s$정도로서 기본형에 비하여 약 $3\sim18%$ 정도 감소하는 것으로 나타났다. 풍하중 작용시 변형도를 비롯하여 축방향력, 전단력, 휨모멘트 등의 최대단면력은 기본형이나 개조형에 관계없이 거의 유사한 경향으로 나타났으며, 최대단면력은 풍상측의 처마높이 부위에서 발생하는 것으로 나타났다. 설하중 작용시 변형도를 비롯하여 축방향력, 전단력, 휨모멘트 등의 최대단면력은 기본형이나 개조형에 관계없이 거의 유사한 경향으로 나타났으며, 축방향력을 제외한 최대단면력은 처마높이 부위에서 발생하였으며, 최대축방향력은 내측기둥에서 발생하였다. 한계적설심에 대한 내측기둥의 좌굴은 모두 안전한 것으로 나타났으며 세장비 또한 제한값 범위내에 들어 기본형 및 개조형 모두 만족하였다. 기초의 인발저항력과 지내력은 기본형과 개조형에 관계없이 모두 안전한 것으로 나타났다.