• Title/Summary/Keyword: Column quantification

Search Result 318, Processing Time 0.02 seconds

Simultaneous Determination of Dictamine, Obacunone and Fraxinellone in Dictamnus dasycarpus cortex by HPLC-DAD (HPLC-DAD를 이용한 백선피의 Dictamine, Obacunone, Fraxinellone의 동시분석법 확립)

  • Song, Ji-Yeon;Lee, Min-A;Yoon, Jeong-Seon;Kim, Dea-Hyun;Kim, Seung-Hyun;Kim, Young-Choong;Sung, Sang-Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.4
    • /
    • pp.323-327
    • /
    • 2010
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of dictamine, obacunone and fraxinellone was established for the quality control of traditional herb Dictamnus dasycarpus cortex. Separation and quantification were successfully achieved with a Shiseido C18 column ($5\;{\mu}m$, 4.6 mm I.D. ${\times}$ 250 mm) by gradient elution of a mixture of methanol and water at a flow rate of 1.0 ml/min. The diode-array UV/Vis detector (DAD) was used for the detection and the wavelength for quantification was set at 236 nm. The presence of dictamine, obacunone and fraxinellone in this extract was ascertained by retention time, spiking with each authentic standard and UV spectrum. All three compounds showed good linearity ($r^2$ > 0.999) in relatively wide concentration ranges. The R.S.D. recovery of each compound was 101.0~103.7% with R.S.D. values less than 1.0%. This method was successfully applied to the determination of contents of dictamine, obacunone and fraxitnellone in three commercial products of D. dasycarpus cortex. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial products.

Simultaneous Determination of Baicalin and Glycyrrhizin in Eul-Ja-Tang by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Park, Jung-Hyun;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-JIn;Kim, Young-Choong;Sung, Sang-Hyun
    • Natural Product Sciences
    • /
    • v.14 no.3
    • /
    • pp.147-151
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, baicalin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Eul-Ja-Tang (EJT). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, 4.6 mm I.D. ${\times}$ 150 mm) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/VIS detector (DAD) was used for the detection and the wavelength for quantification was set at 250 nm. The presence of baicalin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. Both baicalin and glycyrrhizin showed good linearity ($r^2$ > 0.999) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 5% and the limits of detection (LOD) were about 30 ng. The mean recovery of each compound was 99.5 - 101.2% with R.S.D. values less than 4.0%. This method was successfully applied to the determination of contents of baicalin and glycyrrhizin in three commercial products of EJT, which resulted in the difference in the contents of these compounds. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial EJT products.

Simultaneous Determination of Paeoniflorin and Glycyrrhizin in Sayuk-san by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Jeon, Min-Ji;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-Jin;Sung, Sang-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.23-27
    • /
    • 2009
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, paeoniflorin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Sayuk-san (SYS). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}150mm$) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/vis detector (DAD) was used for the detection and the wavelength for quantification was set at 230 nm. The presence of paeoniflorin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. All two compounds showed good linearity ($r^2$>0.996) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 7.3% and the limits of detection (LOD) were less than 55.7 ng. The mean recovery of each compound was $102.3{\sim}111.1%$ with R.S.D. values less than 4.6%. This method was successfully applied to the determination of contents of paeoniflorin and glycyrrhizin in three commercial products of SYS. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial SYS products.

Visualizing Large Two-way Crosstabs by PLS Method (PLS 방법에 의한 "큰" 2원 교차표의 시각화)

  • Lee, Yong-Goo;Choi, Youn-Im
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.3
    • /
    • pp.421-428
    • /
    • 2009
  • On the visualization of categorical data, if the number of categories is small, we can consider Hayashi Quantification Method 3 for visualization of the categories of the variables. But it is known that the method is unstable because it quantifies more significantly for the small frequency categories rather than large frequency categories. The purpose of this research is to propose the visualization of large two-way crosstabulation data by PLS methods for checking the relationship between the categories of row and column variables. In this research, we utilize the PLS visualization methods (Huh et al., 2007) that is proposed for visualization of the qualitative data to visualize the categories of the large categorical data. We also compared both methods by applying them to real data, and studied the results from PLS visualization method on the real categorized data with many categories.

Quantification Analysis and Antioxidant Activity of Leejung-tang (LC-MS/MS를 이용한 이중탕(理中湯)의 정량분석 및 항산화 활성)

  • Seo, Chang-Seob;Kim, Ohn Soon;Kim, Yeji;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.21 no.1
    • /
    • pp.177-185
    • /
    • 2013
  • Objectives : Leejung-tang (Lizhong-tang) has been used for treatment of gastrointestinal disorders in Korea. In this study, we performed quantification analysis of five marker components, liquiritin, ginsenoside Rb1, ginsenoside Rg1, glycyrrhizin, and 6-gingerol in Leejung-tang using a ultra performance liquid chromatography- electrospray ionization-mass spectrometer (UPLC-ESI-MS). In addition, we evaluated antioxidant activity of Leejung- tang. Methods : The column for separation of five constituents used a UPLC BEH C18 ($100{\times}2.1mm$, $1.7{\mu}m$) maintained at $45^{\circ}C$. The mobile phase consisted of two solvent systems, 0.1% (v/v) formic acid in H2O (A) and CH3CN (B) by gradient flow. The flow rate was 0.3 mL/min with detection at mass spectrometer. The antioxidative activities conduct an experiment on 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) and 2,2-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activities of Leejung-tang. Results : Calibration curves of five marker compounds were acquired with r2 values > 0.99. The amount of the five compounds in Leejung-tang were 0.07 - 0.84 mg/g. The concentration required for 50% reduction (RC50) against ABTS radical was 119.02 ug/mL. In addition, the scavenging against DPPH radical of Leejung-tang was 11.4%, 14.5%, 19.8%, 29.6%, and 49.2% at 25 ug/mL, $50{\mu}g/mL$, $100{\mu}g/mL$, $200{\mu}g/mL$, and $400{\mu}g/mL$, respectively. Conclusions : The established LC-MS/MS method will be helpful to improve quality control of Leejung-tang. In addition, Leejung-tang is a potential antioxidant therapeutic agent.

Quantification of the 25 Components in Onkyung-Tang by Ultra Performance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry (UPLC-ESI-MS/MS를 이용한 온경탕 중 25종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.1
    • /
    • pp.92-101
    • /
    • 2016
  • In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometry (UPLC-ESI-MS/MS) method was established for simultaneous determination of the 25 marker components, including chlorogenic acid, gallic acid, oxypaeoniflorin, homogentisic acid, methyl gallate, caffeic acid, 3,4-dihydroxybenzaldehyde, paeoniflorin, albiflorin, liquiritin, nodakenin, ferulic acid, ginsenoside Rg1, liquiritigenin, coumarin, cinnamic acid, benzoylpaeoniflorin, ginsenoside Rb1, cinnamaldehyde, paeonol, glycyrrhizin, 6-gingerol, evodiamine, rutecarpine, and spicatoside A in traditional Korean formula, Onkyung-tang. All analytes were separated on a Waters Acquity UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}m$) at $45^{\circ}C$ using a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile with gradient elution. The MS analysis was carried out using a Waters ACQUITY TQD LC-MS/MS coupled with an electrospray ionization (ESI) source in the positive and negative modes. The flow rate and injection volume were 0.3 mL/min and $2.0{\mu}L$, respectively. The correlation coefficient of all analytes in the test ranges was greater than 0.98. The limits of detection and quantification values of the 25 marker compounds were in the ranges 0.03-19.43 and 0.09-58.29 ng/mL, respectively. As a result, methyl gallate, 3,4-dihydroxybenzaldehyde, evodiamine, and rutecarpine were not detected in this sample and the concentrations of the 21 compounds except for the above 4 compounds were $33.09-3,496.32{\mu}g/g$ in Onkyung-tang decoction. Among these compounds, paeonol was detected at the highest amount as a $3,496.32{\mu}g/g$.

Rapid High Performance Liquid Chromatographic Quantification of Major Isoflavones in Soybeans and Soybean Pastes

  • Kim, Won-Chan;Kwon, Soon-Ho;Rhee, In-Koo;Hur, Jong-Moon;Jeong, Hyun-Hee;Choi, Sun-Ha;Lee, Kyung-Bok;Kang, Young-Hwa;Song, Kyung-Sik
    • Food Science and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.24-27
    • /
    • 2006
  • A simple HPLC quantification method was developed for genistein, genistin, daidzein, and daidzin in soybeans and soybean products. The procedure used a $4.6{\times}100\;mm$ $Chromolith^{(R)}$ RP-18e column with a mobile phase of 1% HOAc in 20% MeOH to 1% HOAc in 80% MeOH for 10 min. The injection volume was $2\;{\mu}L$ at a flow rate of 2 mL/min. Detection was carried out under UV at 254 nm. Under these conditions, the major isoflavones daidzein, daidzin, genistein, and genistin in soybean and soybean pastes were eluted within 7 min with baseline separation. Optimal extraction of the above four major isoflavones was achieved when 40 g of soybean or soybean paste was refluxed in 100 mL of 95% ethanol for 2 hr. Ten different soybean cultivars and nine commercial soybean pastes were analyzed by this method. The total isoflavone content was highest in the cultivar Somyung ($2,497\;{\mu}g/g$ dry weight). The isoflavone content in soybean pastes varied widely from manufacturer to manufacturer (an almost five-fold difference between the highest and lowest values). Such variations were presumably due to differences in fermentation conditions, type of soybeans used, and levels of such additives as starch and salt.

Electrospray-Mass Spectrometric Analysis of Plasma Pyrophosphates Separated on a Multi-Modal Liquid Chromatographic Column

  • Lee, Su-Hyeon;Lee, Jeong-Ae;Lee, Won-Yong;Chung, Bong-Chul;Choi, Man-Ho
    • Mass Spectrometry Letters
    • /
    • v.2 no.4
    • /
    • pp.92-95
    • /
    • 2011
  • Pyrophosphates are the key intermediates in the biosynthesis of isoprenoids, and their concentrations could reveal the benefits of statins in cardiovascular diseases. Quantitative analysis of five pyrophosphates, including isopentenyl pyrophosphate (IPP), dimethylallyl pyrophosphate (DMAPP), geranyl pyrophosphate (GPP), farnesyl pyrophosphate (FPP), and geranylgeranyl pyrophosphate (GGPP), was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in negative ionization mode. After dilution with methanol, samples were separated on a 3 ${\mu}m$ particle multi-modal $C_{18}$ column ($50{\times}2$ mm) and quantified within 10 min. The gradient elution consists of 10 mM ammonium bicarbonate and 0.5% triethylamine (TEA) in water and 0.1% TEA in 80% acetonitrile was used at the flow rate of 0.4 mL/min. Overall recoveries were 51.4-106.6%, while the limit of quantification was 0.05 ${\mu}g$/mL for GPP and FPP and 0.1 ${\mu}g$/mL for IPP, DMAPP, and GGPP. The precision (% CV) and accuracy (% bias) of the assay were 1.9-12.3% and 89.6-111.8%, respectively, in 0.05-10 ${\mu}g$/mL calibration ranges ($R^2$ > 0.993). The devised LC-MS/MS technique with the multi-modal $C_{18}$ column can be used to estimate the biological activity of pyrophosphates in plasma and may be applicable to cardiovascular events with cholesterol metabolism as well as the drug efficacy of statins.

Analytical Method for Methylxanthin, Catechin, and Theaflavin Determinations in Korean Commercial Teas by HPLC (차에 함유된 methylxanthin류, catechin류 및 theaflavin류의 HPLC에 의한 동시분석법)

  • Kim, Soo-Yeun;Kozukue, Nobuyuki;Han, Jae-Sook;Lee, Kap-Rang
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.5-9
    • /
    • 2006
  • Method for separation and quantification of methylxanthins, catechins, and theaflavins in Korean commercial teas (green, oolong, and black teas) was developed using reversed phase high-performance liquid chromatography (HPLC). After extraction with hot water, tea compounds were separated on Inertsil ODS-3v $(5\;{\mu}m)$ column, eluted with gradient of 7% acetonitrile and 93% of 20 mM phosphate buffer mixture for 7 min. Column effluent was monitored at 270 nm. This technique was effective for analyses of m methylxanthins, catechins, and theaflavins in teas and biological samples. In green and oolong teas, two kinds of methylxanthins and 7 of catechins were identified, whereas 4 theaflavins were only identified in black tea. Among seven catechins in green and oolong teas, EGCG showed highest amount, whereas ECG was highest in black tea. (theaflavins were found only in black teas) In all teas, theobromine content was lower than that of caffeine.

Intra-laboratory Validation of an HPLC Post-column Oxidation Method for the Analysis of PSP Toxins in Oysters and Mussels (굴과 진주담치 중 마비성 패류독소 분석을 위한 HPLC post-column oxidation method의 시험소 내 유효성 검증)

  • Song, Ki Cheol;Lee, Ka-Jeong;Yu, Hong-Sik;Mok, Jong-Soo;Kim, Ji Hoe;Lim, Keun-Sik;Lee, Mi-Ae;Kim, Mee-Hye
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.241-247
    • /
    • 2013
  • AOAC Mouse Bioassay Analysis (MBA) has been the gold standard for the analysis of paralytic shellfish poisoning toxin (PSP toxin) for more than 50 years. However, this method has inaccurate limit of quantification and cannot be used to determine toxic profiles. An HPLC method (PCOX) was optimized for Korean shellfish to establish an alternative or supplementary method for PSP analysis and was intended to be used for the official monitoring and regulation of food. The recovery rate of the PCOX method was 83.5-112.1% and the limit of quantification for total toxin was about $8.6{\mu}g$/100 g. A long-term comparison study showed a good correlation of the PCOX results with the AOAC MBA results: the correlation factors were 0.9534 and 0.9109 for oyster and mussel matrices, respectively. The PCOX method may be used as an alternative or supplementary method for AOAC MBA to monitor the occurrence of PSP and to analyze PSP toxin profile in oysters and mussels.