• 제목/요약/키워드: Column Test

검색결과 2,171건 처리시간 0.024초

Test study of precast SRC column under combined compression and shear loading

  • Chen, Yang;Zhu, Lanqi;Yang, Yong
    • Steel and Composite Structures
    • /
    • 제42권2호
    • /
    • pp.265-275
    • /
    • 2022
  • A new type of precast steel reinforced concrete (PSRC) column was put forward in this paper. In order to study the static performance of PSRC column and hollow precast steel reinforced concrete (HPSRC) column subjected to combined compression and shear loading, a parametric test was carried out and effects of axial compression ratio, concrete strength and shear ratio on the mechanical behavior of composite PSRC column and HPSRC column were explored. In addition, the cracks development, load-span displacement relationship, strain distribution and shear bearing strength of column specimens were emphatically focused. Test results implied that shear failure of all specimens occurred during the test, and higher strength of cast-in-place concrete, smaller shear ratio and larger axial compression ratio could lead to greater shear resistance, but when the axial compression ratio was larger than 0.36, the shear capacity began to decrease gradually. Furthermore, truss-arch model for determining the shear strength of PSRC column and HPSRC column was proposed and the calculated results obtained from proposed method were verified to be valid.

파형강관 내부 구속 중공 철근 콘크리트 기둥의 내진 성능 (Seismic Performance of Internally Confined Hollow RC Column with Corrugated Steel Tube)

  • 한택희;김종민;강준석;강영종
    • 한국방재학회 논문집
    • /
    • 제8권2호
    • /
    • pp.31-38
    • /
    • 2008
  • 파형강관으로 내부 구속된 중공 철근콘크리트 기둥(파형강관 내부 구속 중공 RC 기둥, ICH RC-CT column ; Internally Confined Hollow RC column with a Corrugated Steel Tube)의 내진 성능 평가 실험을 수행하였다. 준정적 실험을 통하여 ICH RC-CT 기둥과 일반 중실 RC 기둥의 내진 성능을 비교 평가 하였다. 각각의 기둥 시험체에 대해 하중과 변위의 관계를 측정하였으며, 이를 바탕으로 연성도, 소산에너지, 등가 감쇠비, 손상 지수가 계산되었다. 실험 결과 ICH RC-CT 기둥은 중실 RC 기둥에 비해 작은 에너지 소산능력을 보여주었으나, 에너지 연성도와 등가 점성 감쇠비 측면에서는 거의 대등한 성능을 보여주었다.

철근으로 보강한 콘크리트충전 각형강관 기둥-H형강보 접합부의 거동 (Behavior of Concrete-Filled Square Steel Tubular Column-H Beam Connections with Reinforced bars)

  • 유영찬;신경재;오영석;이승준;문태섭
    • 한국강구조학회 논문집
    • /
    • 제9권3호통권32호
    • /
    • pp.377-390
    • /
    • 1997
  • 본 연구는 콘크리트충전 각형강관을 이용한 기둥-보 접합부에 있어서 시공성과 충전성을 고려하여 철근으로 보강한 콘크리트충전 각형강관 기둥-H형강보 접합부를 제시하고, 1차적으로 보의 인장플랜지와 충전 각형강관 기둥 접합부와의 인장거동을 실험적으로 관찰한 후, 내진 설계 개념을 적용하여 수평 하중을 반복적으로 가할 경우의 접합부 실험을 실시하고 제시한 접합부의 내력 및 변형 특성을 파악한다. 실험결과로부터 항복선이론을 적용하여 내력을 평가하고 접합부의 내력식을 제안하며, 향후 국내의 콘크리트충전 강관구조 규준 제정에 필요한 기초 자료를 제시하는데 그 목적이 있다.

  • PDF

Pullout Test of Headed Reinforcement 2: Deep Embedment

  • Choi, Dong Uk;Shin, InYong
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.1091-1096
    • /
    • 2003
  • Pullout tests of single headed bars using plain concrete blocks indicate that the embedment depth of $10d_b$ is in general required for the headed bars to develop pullout strength equivalent to 125% of bar yield strength. In this experimental study, test results of multiple headed bars installed in reinforced concrete column sections are presented. Test variables included embedment depth, column main reinforcement ratio, and spacing of column ties. 2D29 bars were pulled out at one time from normal strength concrete. Test results indicated that the embedment depths, column tie spacings, and column main reinforcement ratios all influenced the pullout strengths of the headed bars. When the embedment depth was not sufficient, narrow tie spacings especially resulted in increased pullout strengths of the headed bars. Test results also indicated that the embedment depth of 15㏈ was sufficient for the closely spaced two headed bars (head-to-head spacing =$6d_b$) to develop pullout strength equivalent to 125% of the bar yield strength.

  • PDF

대용량 Dynamic RAM의 Data Retention 테스트 회로 설계 (Design of Data Retention Test Circuit for Large Capacity DRAMs)

  • 설병수;김대환;유영갑
    • 전자공학회논문지A
    • /
    • 제30A권9호
    • /
    • pp.59-70
    • /
    • 1993
  • An efficient test method based on march test is presented to cover line leakage failures associated with bit and word lines or mega bit DRAM chips. A modified column march (Y-march) pattern is derived to improve fault coverage against the data retention failure. Time delay concept is introduced to develop a new column march test algorithm detecting various data retention failures. A built-in test circuit based on the column march pattern is designed and verified using logic simulation, confirming correct test operations.

  • PDF

실내모형시험을 통한 Gravel Drain의 배수효과에 관한 연구 (A Study on the Drainage Effects of Gravel Drain by Laboratory Model Test)

  • 천병식;김백영;고용일;여유현;박경원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.87-94
    • /
    • 1999
  • Sand drain as a vertical drainage is widely used in soft ground improvement. Recently, sand, the principal source of sand drain, is running out. A laboratory model test was carried out to utilize gravel as a substitute for sand. Though which the characteristics of gravel are compared to those of sand for engineering purpose. Two cylindrical containers for the model test were filled with marine clayey soil from the west coast of Korea with a column in the center, one with sand, the other with gravel. Vibrating wire type piezometers were installed at the distance of 1.0D, 1.5D and 2.0D from the center of the column. D is the diameter of the column. The transient process of pore water pressure with loading and the characteristics of consolidation were studied with the data gained from the measuring instrument place on the surface of the container. The parameter study was performed for the marine clayey soil before and after the test in order to check the effectiveness of the improvement. The clogging effect was checked at various depth in gravel column after the test. According to the test, the settlement was found to be smaller in gravel drain than in sand drain. The increase in bearing capacity by gravel pile explains the result. The clogging effect was not found in gravel column. As a result, it is assumed that gravel is relatively acceptable as a drainage material.

  • PDF

진동대실험을 통한 축소 아치구조물의 고유진동주기 분석 (Natural Vibration Period of Small-scaled Arch Structure by Shaking Table Test)

  • 김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제15권4호
    • /
    • pp.107-114
    • /
    • 2015
  • Large spatial structures can not easily predict the dynamic behavior due to the lack of construction and design practices. The spatial structures are generally analyzed through the numerical simulation and experimental test in order to investigate the seismic response of large spatial structures. In the case of analysis for seismic response of large spatial structure, the many studies by the numerical analysis was carried out, researches by the shaking table test are very rare. In this study, a shaking table test of a small-scale arch structure was conducted and the dynamic characteristics of arch structure are analyzed. And the dynamic characteristics of arch structures are investigated according to the various column cross-section and length. It is found that the natural vibration periods of the small-scaled arch structure that have large column stiffness are very similar to the natural vibration period of the non-column arch structure. And in case of arch structure with large column stiffness, primary natural frequency period by numerical analysis is very similar to the primary natural frequency period of by shaking table test. These are because the dynamic characteristics of the roof structure are affected by the column stiffness of the spatial structure.

이축반복하중을 받는 2주형 철근콘크리트 교각의 실험거동 (Experimental Behavior of Reinforced Concrete Column-Bent Piers under Bidirectional Repeated Loading)

  • 박창규;이범기;송희원;정영수
    • 한국지진공학회논문집
    • /
    • 제9권1호통권41호
    • /
    • pp.17-24
    • /
    • 2005
  • 기존의 RC 교각에 대한 내진성능 연구는 실험여건상 일방향 반복하중을 받는 단주교각에 집중되어 있었다. 그러나 고속도로상의 교각은 대다수가 다주교각으로 이루어져 있으므로, 본 연구에서는 국내고속도로에서 많이 사용되고 있는 2주형 교각에 대한 이축지진하중에서의 지진응답을 실험적으로 조사하였다. 실험체는 지름 400mm, 높이 2,000mm인 2주형 원형 교각 4기를 제작하였으며, $0.1f_{ck}A_g$크기의 축방향 하중작용하에서 횡방향 하중을 이축으로 교번반복 재하하였다. 실험변수는 횡구속 철근비와 주철근 겹침이음으로서 기존 단주에 대한 연구결과와 유사하게 이들 실험변수들은 교각의 내진성능에 상당한 영향을 미치고 있었다. 또한 동일하게 설계된 일축하중을 받는 단주와 이축하중을 받는 다주의 내진성능을 비교한 결과 단주의 경우 손상이 하부 소성힌지 한 곳에 집중된 반면 다주의 경우 교축직각방향 하중으로 인하여 손상이 상ㆍ하부 두 곳으로 분산되어 나타났다.

Field behaviour geotextile reinforced sand column

  • Tandel, Yogendra K.;Solanki, Chandresh H.;Desai, Atul K.
    • Geomechanics and Engineering
    • /
    • 제6권2호
    • /
    • pp.195-211
    • /
    • 2014
  • Stone columns (or granular column) have been used to increase the load carrying capacity and accelerating consolidation of soft soil. Recently, the geosynthetic reinforced stone column technique has been developed to improve the load carrying capacity of the stone column. In addition, reinforcement prevents the lateral squeezing of stone in to surrounding soft soil, helps in easy formation of stone column, preserve frictional properties of aggregate and drainage function of the stone column. This paper investigates the improvement of load carrying capacity of isolated ordinary and geotextile reinforced sand column through field load tests. Tests were performed with different reinforcement stiffness, diameter of sand column and reinforcement length. The results of field load test indicated an improved load carrying capacity of geotextile reinforced sand column over ordinary sand column. The increase in load carrying capacity depends upon the sand column diameter, stiffness of reinforcement and reinforcement length. Also, the partial reinforcement length about two to four time's sand column diameter from the top of the column was found to significant effect on the performance of sand column.

외부다이아프램으로 보강한 콘크리트충전 각형강관 기둥-H형강보 접합부의 거동 (Behavior of Concrete-Filled Square Steel Tubular Column-H Beam Connections with Exterior Diaphragm)

  • 유영찬;이승준;문태섭
    • 한국강구조학회 논문집
    • /
    • 제9권2호통권31호
    • /
    • pp.205-220
    • /
    • 1997
  • 본 연구는 콘크리트충전 각형강관을 이용한 기둥-보 접합부에 있어서 시공성과 충전성을 고려하여 외부다이아프램으로 보강한 콘크리트충전 각형강관 기둥-H형강보 접합부를 제시하고, 1차적으로 보의 인장플랜지와 충전 각형강관 기둥 접합부와의 인장거동을 실험적으로 관찰한 후, 내진설계 개념을 적용하여 수평 하중을 반복적으로 가할 경우의 접합부 실험을 실시하고 제시한 접합부의 내력 및 변형 특성을 파악한다. 실험결과로부터 항복선 이론을 적용하여 내력을 평가하고 접합부의 내력식을 제안하며, 향후 국내의 콘크리트충전 강관구조 규준 제정에 필요한 기초 자료를 제시하는데 그 목적이 있다.

  • PDF