• Title/Summary/Keyword: Color stability

Search Result 1,062, Processing Time 0.025 seconds

COLOR STABILITY OF CEROMERS AFTER THERMOCYCLING AND BRUSHING (잇솔질과 열처리가 세로머의 색안정성에 미치는 영향)

  • Yi Yang-Jin;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.37-48
    • /
    • 2001
  • Ceromers, new indirect resin system, are now being adopted for esthetic restorations. Despite of its translucency and good color matching, color stability after long-term use was unknown till now. This in vitro study was designed to evaluate color stability of some ceromers when subjected to brushing after thermocycling. Three types of ceromers: Scupture, Targis, Artglass and a direct resin system, Z100 were prepared to disks 12 mm in diameter, 2.5 mm in thickness. All specimens were polished, and Sculpture and Targis specimens were divided two groups, respectively. Then, half of them were glazed according to manufacturer's instructions. All specimen were brushed 20,000 times after 10,000 cycle thermocycling. Color was measured with spectrophotometer after 1,000, 3,000, 10,000 times thermocycling and 20,000 time brushing, respectively. Color difference (${\Delta}E$) was calculated according to CIE LAB system. During thermocycling, Sculpture & Targis system with polished surface showed greater color change than any other groups. After brushing, color difference was reduced significantly. Mean values of ${\Delta}E$ ranged 0.98 to 2.98. All Ceromers were considered clinically acceptable after thermocycling and brushing, and color change mechanism was affected by the brands and finishing methods. It might be concluded that color change of ceromer is due to surface alteration.

  • PDF

Physical properties and color stability of injection-molded thermoplastic denture base resins

  • Song, So-Yeon;Kim, Kyoung-Soo;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.32-40
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare mechanical and physical properties of injection-molded thermoplastic denture base resins. MATERIALS AND METHODS. In this study, six commercially available products (VA; Valplast, LC; Lucitone, ST; Smiltone, ES; Estheshot-Bright, AC; Acrytone, WE; Weldenz) were selected from four types of thermoplastic denture base materials (Polyamide, Polyester, Acrylic resin and Polypropylene). The flexural properties and shore D hardness have been investigated and water sorption and solubility, and color stability have evaluated. RESULTS. For the flexural modulus value, ES showed the highest value and WE showed significantly lower value than all other groups (P<.05). Most of experimental groups showed weak color stability beyond the clinically acceptable range. CONCLUSION. Within the limits of this study, thermoplastic denture base resin did not show sufficient modulus to function as a denture base. In addition, all resins showed discoloration with clinical significance, and especially polyamides showed the lowest color stability.

Effect of Accelerated Aging on the Color Stability of Dual-Cured Self-Adhesive Resin Cements

  • Kim, Ah-Rang;Jeon, Yong-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • v.8 no.2
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: The effect of accelerated aging on color stability of various dual-cured self-adhesive resin cements were evaluated in this study. Materials and Methods: Color stability was examined using three different brands of dual-cured self-adhesive resin cements: G-CEM LinkAce (GC America), MaxCem Elite (Kerr), and PermaCem 2.0 (DMG) with the equivalent color shade. Each resin cement was filled with Teflon mold which has 6 mm diameter and 2 mm thickness. Each specimen was light cured for 20 seconds using light emitting diode (LED) light curing unit. In order to evaluate the effect of accelerated aging on color stability, color parameters (Commission Internationale de l'Eclairage, CIE $L^*$, $a^*$, $b^*$) and color differences (${\Delta}E^*$) were measured at three times: immediately, after 24 hours, and after thermocycling. The $L^*$, $a^*$, $b^*$ values were analyzed using Friedman test and ${\Delta}E^*$ values on the effect of 24 hours and accelerated aging were analyzed using t-test. These values were compared with the limit value of color difference (${\Delta}E^*=3.7$) for dental restoration. One-way ANOVA and Scheff's test (P<0.05) were performed to analyze each ${\Delta}E^*$ values between cements at each test period. Result: There was statistically significant difference in comparison of color specification ($L^*$, $a^*$, $b^*$) values after accelerated aging except $L^*$ value of G-CEM LinkAce (P<0.05). After 24 hours, color difference (${\Delta}E^*$) values were ranged from 2.47 to 3.48 and $L^*$ values decreased and $b^*$ values increased in all types of cement and MaxCem Elite had high color stability (P<0.05). After thermocycling, color change's tendency of cement was varied and color difference (${\Delta}E^*$) values were ranged from 0.82 to 2.87 and G-CEM LinkAce had high color stability (P<0.05). Conclusion: Color stability of dual-cured self-adhesive resin cements after accelerated aging was evaluated and statistically significant color changes occurred within clinically acceptable range.

Storage Stability and Color Reproducibility of Yellow and Red Dyes Extracted from Carthamus tinctorius L.

  • Shin, Youn-Sook;Yoo, Dong-Il
    • Textile Coloration and Finishing
    • /
    • v.24 no.3
    • /
    • pp.165-172
    • /
    • 2012
  • The stability of yellow and red dyes prepared from safflower (Carthamus tinctorius L.) in aqueous solution and in solid state was investigated. External factors such as light irradiation and temperature on the stability were examined during storage. Changes in absorbance of dye solutions and the color changes of fabrics dyed after long time storage were measured. Also, color reproducibility during storage was investigated by dyeing test on various fabrics. Red colorant in aqueous solution was very unstable to light, resulting that about 40% of absorbance were lost in 12hrs. The absorbance of yellow dye solutions was not decreased within 84hrs. In aqueous medium, yellow dye was much more stable than carthamin. Both dyes are relatively stable for long storage when they are stored in solid state compared to when in aqueous solution. Color changes are marginal in both dyes.

Yellow Color Extraction from Gardenia jasmonoides Ellis for Development of Natural Food Color (천연식용색소 개발을 위한 치자에서 황색소의 추출)

  • 김희구;손홍주
    • The Korean Journal of Food And Nutrition
    • /
    • v.10 no.2
    • /
    • pp.241-245
    • /
    • 1997
  • In order to make natural food color from Gardenia, we investigated optimal conditions of color extraction, and thermal stability and light stability of color extracted compared with Yellow-4. In case of ethanol extraction, optimal conditions for color extraction were substrate 10%, 4$0^{\circ}C$, pH 7.0 and 42rs, respectively. In case of water extraction, optimal conditions for color extraction were substrate 10%, 7$0^{\circ}C$, pH 7.0 and 48hrs, respectively. Extraction yield in the optimal conditions was 75% in ethanol and 63% in water. The thermal stability and light stability of Yellow-4 were both upper 98%, but those of Gardenia yellow color were 62 and 90%, respectively.

  • PDF

A Study on Emotional Information System Using User Color Information

  • Ko, Hye-Kyeong
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.82-92
    • /
    • 2019
  • The appropriate use of color and light can increase psychological stress or feelings of mental stability. As such, many people currently use color therapy, which provides relaxation and stability through color stimulation. Many people currently use color therapy, which provides relaxation and stability through color stimulation. The smartphone-based psychological color therapy system that is to be developed through the study is a method for relieving stress. This study examines a method of using smartphones to understand user's emotional information such as types of stress and to provide color therapy information regarding these emotions. The goal of this study is to use the user's smart phone to provide color therapy that employs the user's emotional information. The intelligent emotion system, which uses platforms such as mobile devices and the PC, was designed considering the user's context, and it provides the user with various data formats such as images, video, text, audio, to send results to the user. The system was developed in the form of a service-based mobile application. The study designed an emotional color therapy system that uses a smartphone to measure the user's stress and provides appropriate color therapy.

Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

  • Jang, Dae-Eun;Lee, Ji-Young;Jang, Hyun-Seon;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.278-287
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS. Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. RESULTS. All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. CONCLUSION. Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed.

STUDY ON THE COLOR STABILITY OF VENEER RESIN (Veneer Resin의 색안정성에 관한 연구)

  • Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 1991
  • The purpose of this study was to investigate the color stability of 2 light - polymerized veneer resins and 3 heat - polymerized veneer resins. Five specimen discs of each brand were immersed in distilled water at $37^{\circ}C$, in darkroom for 120 days. The distilled water was changed on every third day to prevent contamination from micro - organisms. The color characteristics of all the samples were measured by computer controlled spectrophotometer. The appearence was characterized by means of the $L^*$, $a^*$ and $b^*$ uniform color space(CIELAB) and total color difference was calculated. The following results were obtained 1) ${\Delta}E^*ab$ - value in all brand except IS is were greater than 1 perceptable in visual evaluation. 2) ${\Delta}E^*ab$ - value in VI, IS and VG were lower than upper limit of acceptablilty(3.3 in ${\Delta}E^*ab$). DC was the worst in color stability and was changed into yellow color.

  • PDF

Electroencephalogram Analysis on Learning Factors during Relaxed or Concentrated Attention according to the Color Temperatures of LED Illuminance (이완집중 및 긴장집중 시 LED 조명의 색온도에 따른 학습요인의 뇌파분석)

  • Jee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.6
    • /
    • pp.33-42
    • /
    • 2014
  • The objective of this study is to investigate learning factors (stability, attention and activation) in school by electroencephalogram (theta, alpha and beta waves) analysis during relaxed or concentrated. In order to measure electroencephalograms, MP 150 by Biopac and ECI Electro-Cap are employed. Three types of color temperatures (3000K, 5000K, 7000K) are used and 13 undergraduate and 12 graduate students are selected as experimental subjects. When subjects are relaxed during contemplation or concentrated during mental arithmetic, we compare with stability, attention and activation indices. The test results show that subjects were stable when color temperature is 5000K. Subjects gave best attention when color temperature is 7000K. Subjects activated well when color temperature is 3000K during relaxed attention. However, subjects activated rigorous when color temperature is 7000K during constrained attention.

Color enhancement system Based on the improvement of Transition Time and color detdetion Stability (천이 시간 개선과 색검출 안정화 기반의 색 향상 시스템)

  • Lee, Eung-Joo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.3
    • /
    • pp.715-719
    • /
    • 1998
  • In this paper, we propose a color enhancement system which is based on the improvement of transition time problem and specific color detection stability. The proposcd system apply the time difference correction step to corrects time difference which is taken place at the transimission process between color signal and color subcarrier signal and to reduce detection errors. And also, we proposed stability method to improve transition time problem and detection efficiency as the control of reference color. The proposed system controls specific color when the mean difference value of detected voltages greater than the value of minimum discriminate voltages of two adjacent color signals. Thus, the color enhancement system improves detection efficiency and controls specific color from the color signal without overlapping of correction range.

  • PDF