• Title/Summary/Keyword: Color coordinates

Search Result 300, Processing Time 0.027 seconds

A Study on Digital Control Method of LED Luminance (LED 휘도의 디지털 제어 방식에 관한 연구)

  • Kang, Shin-Ho;Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • The pulse width modulation(PWM) method has been generally used as conventional method controlling luminance of LED(light emitting diode). PWM method as analog method with a relation that duty ratio of LED be proportional to luminance has weak point that it is not compatible with digital method of communication etc. In this paper, a experiment is conducted which the luminance of RGB LED be controlled by digital method. For this, the LED digital control system is developed which consist of LED driving circuits and digital logic circuits. By controlling the number of pluses on RGB LED versus digital input, various lighting colors is implemented and digital codes are optimized in order that measured x, y chromaticity coordinates of lighting colors are comprised in the CIE chromaticity coordinates area of targeted lighting colors. The result of this study can be utilized usefully in research on implementing full color by using remote control of LED lamp with digital communication.

A STUDY ON THE ANALYSIS OF OCCLUSAL CURVE OF THE NORMAL SUBJECTS (정상인의 교합 만곡 분석에 관한 연구)

  • Choi, Myung-Sik;Kay, Kee-Sung;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.95-122
    • /
    • 1990
  • This study was done to analyze the occlusal curve as one of the factors to be considered for maintenance of occlusal stability in the orthodontic and prosthodontic treatments. Sixty gnathological casts we.e obtained from 43 subjects with normal occlusion and 17 subjects with some of temporomandibular disorders. The occlusal surfaces of gnathologic casts were duplicated by using a Color kit SK-700 and tile reference points of X, Y coordinates were digitized by using the Summagraphic digitizer and 18AT computer system. The Z coordinates of cusp height were measured by 0.01mm measurable caliper. The mathematical computer program of least square method was used to analyze the occlusal curve arranged by three dimensional coordinates of X, Y, Z. The following results were obtained : 1. The occlusal curve of buccal and lingual cusp tips was fitted to the ellipse, and the occlusal curve of anterior teeth was fitted to a part of the circle in the analysis of conic sections. 2. The radius of Spee's curve showed individual differences, but was average 98.7mm in male subjects and 93.7mm in female subjects. 3. The radius fo Spee's curve according to the half of canine width showed the least coefficient of variation. 4. The radius of Spee's curve was not significantly relative to the lateral occlusal contacts on laterotrusion and the absence or presence of temporomandibular disorders. 5. The radius of Wilson's curve showed individual difference and the size of radius was followed by the order of 1st premolar, 2nd premolar, 2nd molar and 1st molar.

  • PDF

Optical and Electrical Properties of Two-Wavelength White Tandem Organic Light-Emitting Diodes Using Red and Blue Materials (적색과 청색 물질을 사용한 2파장 방식 백색 적층 OLED의 광학 및 전기적 특성)

  • Park, Chan-Suk;Jua, Sung-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.9
    • /
    • pp.581-586
    • /
    • 2015
  • We studied optical and electrical properties of two-wavelength white tandem organic light-emitting diodes using red and blue materials. White fluorescent OLEDs were fabricated using Alq3 : Rubrene (3 vol.% 5 nm) / SH-1 : BD-2 (3 vol.% 25 nm) as emitting layer (EML). White single fluorescent OLED showed maximum current efficiency of 9.7 cd/A, and tandem fluorescent OLED showed 18.2 cd/A. Commission Internationale de l'Eclairage (CIE) coordinates of single and tandem fluorescent OLEDs was (0.385, 0.435), (0.442, 0.473) at $1,000cd/m^2$, respectively. White hybrid OLEDs were fabricated using SH-1 : BD-2 (3 vol.% 10 nm) / CBP : $Ir(mphmq)_2(acac)$ (2 vol.% 20 nm) as EML. White single hybrid OLED showed maximum current efficiency of 7.8 cd/A, and tandem hybrid OLED showed 26.4 cd/A. Maximum current efficiency of tandem hybrid OLED was more twice as high as single OLED. CIE coordinates of single hybrid OLED was (0.315, 0.333), and tandem hybrid OLED was (0.448, 0.363) at $1,000cd/m^2$. CIE coordinates in white tandem OLEDs compared to those for single OLEDs observed red shift. This work reveals that stacked white OLED showed current efficiency improvement and red shifted emission than single OLED.

Neuro-controller for Broadcast Lighting LED to Express xy Chromaticity Coordinates (xy 색도좌표 표현을 위한 방송 조명용 LED 신경망 제어기)

  • Park, Sung-Chan;Park, Jin-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.6
    • /
    • pp.706-713
    • /
    • 2020
  • To control the LED lighting for broadcasting, LED current control using tri-stimulus values is used for RGB LEDs. For the convenience of control, this control is approximated as a linear function or used as an appropriate value through trial and error. Also, it is not suitable for broadcast lighting because it does not use a diffuser plate applied for mixing sufficient light and color required for actual it. In this study, a neural network with excellent nonlinear function approximation is used as a control method for LED panels for broadcast lighting. We intend to implement an LED panels controller suitable for the desired chromaticity coordinates and dimming values of intensity. As a result of the performance evaluation, the errors of the xy chromaticity coordinates are mostly ±0.02 and the acceptable range of ANSI C78.377A was satisfied. The average errors of the xy chromaticity coordinate are xerror=0.0044 and yerror=0.0030, respectively, and we confirmed the superiority and stable performance of the proposed algorithm.

Excimer-Based White Phosphorescent OLEDs with High Efficiency

  • Yang, Xiaohui;Wang, Zixing;Madakuni, Sijesh;Li, Jian;Jabbour, Ghassan E.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1520-1521
    • /
    • 2008
  • There are several ways to demonstrate white organic light emitting diodes (OLEDs) for displays and solid state lighting applications. Among these approaches are the stacked three primary or two complementary colors light-emitting layers, multiple-doped emissive layer, and excimer and exciplex emission [1-10]. We report on white phosphorescent excimer devices by using two light emitting materials based on platinum complexes. These devices showed a peak EQE of 15.7%, with an EQE of 14.5% (17 lm/W) at $500\;cd/m^2$, and a noticeable improvement in both the CIE coordinates (0.381, 0.401) and CRI (81). Devices with the structure ITO/PEDOT:PSS/TCTA (30 nm)/26 mCPy: 12% FPt (10 nm) /26 mCPy: 2% Pt-4 (15 nm)/BCP (40 nm)/CsF/Al [device 1], ITO/PEDOT:PSS/TCTA (30 nm)/26 mCPy: 2% Pt-4 (15 nm)/26 mCPy: 12% FPt (10 nm)/BCP (40 nm)/CsF/Al [device 2], and ITO/PEDOT:PSS/TCTA (30 nm)/26 mCPy: 2% Pt-4: 12% FPt (25 nm)/BCP (40 nm)/CsF/Al [device 3] were fabricated. In these cases, the emissive layer was either the double-layer of 26 mCPy:12% FPt and 15 nm 26 mCPy: 2% Pt-4, or the single layer of 26mCPy with simultaneous doping of Pt-4 and FPt. Device characterization indicates that the CIE coordinates/CRI of device 2 were (0.341, 0.394)/75, (0.295, 0.365)/70 at 5 V and 7 V, respectively. Significant change in EL spectra with the drive voltage was observed for device 2 indicating a shift in the carrier recombination zone, while relatively stable EL spectra was observed for device 1. This indicates a better charge trapping in Pt-4 doped layers [10]. On the other hand, device 3 having a single light-emitting layer (doped simultaneously) emitted a board spectrum combining emission from the Pt-4 monomer and FPt excimer. Moreover, excellent color stability independent of the drive voltage was observed in this case. The CIE coordinates/CRI at 4 V ($40\;cd/m^2$) and 7 V ($7100\;cd/m^2$) were (0.441, 0.421)/83 and (0.440, 0.427)/81, respectively. A balance in the EL spectra can be further obtained by lowering the doping ratio of FPt. In this regard, devices with FPt concentration of 8% (denoted as device 4) were fabricated and characterized. A shift in the CIE coordinates of device 4 from (0.441, 0.421) to (0.382, 0.401) was observed due to an increase in the emission intensity ratio of Pt-4 monomer to FPt excimer. It is worth noting that the CRI values remained above 80 for such device structure. Moreover, a noticeable stability in the EL spectra with respect to changing bias voltage was measured indicating a uniform region for exciton formation. A summary of device characteristics for all cases discussed above is shown in table 1. The forward light output in each case is approximately $500\;cd/m^2$. Other parameters listed are driving voltage (Bias), current density (J), external quantum efficiency (EQE), power efficiency (P.E.), luminous efficiency (cd/A), and CIE coordinates. To conclude, a highly efficient white phosphorescent excimer-based OLEDs made with two light-emitting platinum complexes and having a simple structure showed improved EL characteristics and color properties. The EQE of these devices at $500\;cd/m^2$ is 14.5% with a corresponding power efficiency of 17 lm/W, CIE coordinates of (0.382, 0.401), and CRI of 81.

  • PDF

Color Component Analysis For Image Retrieval (이미지 검색을 위한 색상 성분 분석)

  • Choi, Young-Kwan;Choi, Chul;Park, Jang-Chun
    • The KIPS Transactions:PartB
    • /
    • v.11B no.4
    • /
    • pp.403-410
    • /
    • 2004
  • Recently, studies of image analysis, as the preprocessing stage for medical image analysis or image retrieval, are actively carried out. This paper intends to propose a way of utilizing color components for image retrieval. For image retrieval, it is based on color components, and for analysis of color, CLCM (Color Level Co-occurrence Matrix) and statistical techniques are used. CLCM proposed in this paper is to project color components on 3D space through geometric rotate transform and then, to interpret distribution that is made from the spatial relationship. CLCM is 2D histogram that is made in color model, which is created through geometric rotate transform of a color model. In order to analyze it, a statistical technique is used. Like CLCM, GLCM (Gray Level Co-occurrence Matrix)[1] and Invariant Moment [2,3] use 2D distribution chart, which use basic statistical techniques in order to interpret 2D data. However, even though GLCM and Invariant Moment are optimized in each domain, it is impossible to perfectly interpret irregular data available on the spatial coordinates. That is, GLCM and Invariant Moment use only the basic statistical techniques so reliability of the extracted features is low. In order to interpret the spatial relationship and weight of data, this study has used Principal Component Analysis [4,5] that is used in multivariate statistics. In order to increase accuracy of data, it has proposed a way to project color components on 3D space, to rotate it and then, to extract features of data from all angles.

Comparison of the optical properties of pre-colored dental monolithic zirconia ceramics sintered in a conventional furnace versus a microwave oven

  • Kim, Hee-Kyung;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.394-401
    • /
    • 2017
  • PURPOSE. The purpose of this study was to compare the optical properties of pre-colored dental monolithic zirconia ceramics of various thicknesses sintered in a microwave and those in a conventional furnace. MATERIALS AND METHODS. A2-shade of pre-colored monolithic zirconia ceramic specimens ($22.0mm{\times}22.0mm$) in 3 thickness groups of 0.5, 1.0, and 1.5 mm were divided into 2 subgroups according to the sintering methods (n=9): microwave and conventional sintering. A spectrophotometer was used to obtain CIELab color coordinates, and translucency parameters and CIEDE2000 color differences (${\Delta}E_{00}$) were measured. The relative amount of monoclinic phase ($X_m$) was estimated with x-ray diffraction. The surface topography was analyzed by atomic force microscope and scanning electron microscope. Statistical analyses were conducted with two-way ANOVA (${\alpha}=.05$). RESULTS. There were small interaction effects on CIE $L^*$, $a^*$, and TP between sintering method and thickness (P<.001): $L^*$ (partial eta squared ${{\eta}_p}^2=0.115$), $a^*$ (${{\eta}_p}^2=0.136$), and TP (${{\eta}_p}^2=0.206$), although higher $b^*$ values were noted for microwave sintering regardless of thickness. Color differences between two sintering methods ranged from 0.52 to 0.96 ${\Delta}E_{00}$ units. The $X_m$ values ranged from 7.03% to 9.89% for conventional sintering, and from 7.31% to 9.17% for microwave sintering. The microwave-sintered specimen demonstrated a smoother surface and a more uniform grain structure compared to the conventionally-sintered specimen. CONCLUSION. With reduced processing time, microwave-sintered pre-colored dental monolithic zirconia ceramics can exhibit similar color perception and translucency to those by conventional sintering.

Highly Efficient Trans-Reflective Color Filters Incorporating TiO2-MgF2 Multilayer Stacks

  • Shrestha, Vivek Raj;Park, Chul-Soon;Koirala, Ishwor;Lee, Sang-Shin;Choi, Duk-Yong
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.566-574
    • /
    • 2015
  • We report for the first time highly efficient trans-reflective color filters capable of demonstrating coloration in both transmission and reflection modes by taking advantage of a multilayer stack consisting of MgF2 and TiO2 used respectively as the low and high index materials. In order to enable such trans-reflective performance, securing an optimal stop band assuming an appropriate bandwidth within the visible regime is pivotal, which was realized by tailoring the thicknesses and the numbers of TiO2-MgF2 bi-layers. Three devices were designed through rigorous simulations and developed via e-beam evaporation to demonstrate vivid blue, green, and red colors in the reflection mode, and yellow, magenta, and cyan colors in the transmission mode, featuring an enhanced efficiency exceeding 90% under normal incidence. The color performance of the filters was examined by referring to the chromaticity coordinates of the transmission and reflection spectra, alongside photographed color images. The dependence of the performance on the angle of incidence was explored with respect to incident polarization, indicating that a transmission surpassing 60% could be stably maintained up to an angle of 75°. Polarization independent transfer characteristics were especially achieved for the normal incidence. The proposed devices may be readily extended to other spectral regimes by adjusting the thicknesses of the films.

Real-Time face detection using the Skin color and Haar-like feature (피부색과 Haar-like feature를 이용한 실시간 얼굴검출)

  • Jeong, Joong-Gyo;Park, Sang-Sung;Jang, Dong-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.4 s.36
    • /
    • pp.113-121
    • /
    • 2005
  • Face detection in real-time video constitutes one of the major trend in face recognition. In this paper, we propose a face detection algorithm using the skin color and Haar-like feature in real-time video. The proposed algorithm is followed by three sequences; First, moving objects are detected by difference-method in YCbCr coordinates, and then by using Haar-like features, face candidate regions of the moving objects is selected. Finally we extract the most possible face candidates by comparing the pixel values of face candidates with the skin color. In order to prevent a mistake. we use similar features or skin color to detect a face by selecting a adaptive ROI and improve the processing speed in real-time video. The computer simulation shows the validity of the proposed method that the processing speed is improved by 30% than previous works and the detection success rate is 96.8%.

  • PDF

A Study on Seasonal Color Image of Flower Display in Commercial Spaces (상업공간 플라워 디스플레이의 계절별 색채이미지에 관한 연구)

  • Yang, Hee Sun;Wang, Kyung Hee;KIm, Jung Min
    • Journal of the Korean Society of Floral Art and Design
    • /
    • no.43
    • /
    • pp.3-17
    • /
    • 2020
  • Through color analysis and survey of seasonal display cases using flower materials in department stores, hotels, and retailers, which are representative commercial spaces in Korea and abroad, it is designed to recognize the need for color planning that applies seasonal colors and emotional adjectives, away from the traditional method of relying on the season, shape and texture of materials, in the process of flower displays. The research method analyzed the colors used in the 48 domestic and foreign commercial space flower display cases collected. Based on this, the first expert questionnaire collected adjectives extraction and seasonal coordinates reminiscent of the case and examined the suitability of emotional adjectives extracted by the second public survey. The research results extracted typical colors and tones of spring, summer, fall, and winter, and recognized seasonal emotional adjectives. Based on these results, We could see that the color scheme should be advanced in the flower display, which used to depend solely on the shape or texture of the flower material, to produce the intended emotional design.