• 제목/요약/키워드: Colloid

검색결과 428건 처리시간 0.021초

$^{113m}In$ 교질(膠質)에 의(依)한 간주사(肝走査)에 관(關)한 연구(硏究) (A Study of Liver Scan using $^{113m}In$ Colloid)

  • 고창순;이종헌;장고창;홍창기
    • 대한핵의학회지
    • /
    • 제3권1호
    • /
    • pp.83-99
    • /
    • 1969
  • There have been reported numberous cases of liver scanning in use of $^{198}Au$ colloid by many investigators, however, one in use of $^{113m}In$ colloid has not been reported as yet in this country. The dose of $^{113m}In$ for high diagnostic value in examination of each organ was determined and the dignostic interpretability of liver scanning with the use of $^{113m}In$ was carefully evaluated in comparison with the results of the liver scanning by the conventionally applied radioisotopes. The comparative study of both figures of liver scannings with the use of $^{113m}In$ colloid and $^{198}Au$ colloid delivered following results: 1. The liver uptake rate and clearance into peripheral blood were accentuated more in case of $^{113m}In$ colloid than in case of $^{198}Au$ colloid. 2. The interpretability of space occupying lesion in liver scanning with $^{113m}In$ was also superior to one with $^{198}Au$. 3. The figure of liver scanning with $^{113m}In$ colloid corresponds not always to the figure with $^{198}Au$. This difference can be explained by differences of phagocytic ability of reticuloendotherial system within liver. 4. In the liver scanning with $^{113m}In$ colloid, the spleen is also visualized even in normal examinee. 5. In the cases of disturbed liver function, uptake is more decreased in use of $^{113m}In$ colloid than in $^{198}Au$, in the spleen, however, the way is contrary. 6. With use of $^{113m}In$ colloid, the time required for scanning could be shortened in comparison with $^{198}Au$. 7. The filtration of $^{113m}In$ colloid for scanning prior to human administration gives an expectation for better scanning figure.

  • PDF

Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가 (Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy)

  • 이훈희;김찬규;송관수;방문균;강동윤;신동호;이두현
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.191-199
    • /
    • 2018
  • 목 적 : 본 연구는 colloid gel(slime)을 자체 제작하여, 방사선치료에서 불규칙한 환자 체표면에 대한 보상체로 적용하기 위하여 유용성을 평가하고자 한다. 대상 및 방법 : 본 연구를 위하여 치료에 적합한 colloid gel을 자체적으로 제작하였고, 방사선 치료 적용 가능성 평가를 위해 네 가지 실험을 하였다. 치료 장비 및 CT 장비로는 Trilogy(Varian)와 CT(SOMATOM, Siemens)를 이용하였다. 첫 번째로 colloid gel의 조성에 따른 균질도를 EBT3 Film(RIT)을 이용하여 측정하였다. 두 번째는 colloid gel의 Hounsfield Unit(HU)값을 CRIS phantom과 Eclipse RTP(Eclipse 13.1, Varian) 및 CT 촬영을 이용하여 선량 측정 및 확인을 하였다. 세 번째로 colloid gel의 치료 기간 내 변형 및 변질을 검사하기 위하여 ion chamber(PTW-30013, PTW)를 이용하여 매일 3회씩, 2주간 측정하였다. 네 번째 실험은 자체 제작한 아크릴 팬텀을 이용하여 실제 치료와 유사한 환경에서 bolus, rice, colloid gel을 이용한 치료계획 및 측정된 선량 분포 비교하였고, 추가적으로 dose profile도 확인하였다. 결 과 : 첫 번째 실험에서 조성된 colloid gel case 1, 2, 3의 밀도는 각각 평균 $1.02g/cm^3$, $0.99g/cm^3$, $0.96g/cm^3$이었으며, 6 MV 및 9 MeV에서 측정된 균질도를 판단하였을 때 case 1이 표준편차 1.55, 1.98로 다른 case들에 비해 더 균질한 것으로 확인되었다. 두 번째 실험에서는 HU값은 case 1, 2, 3 평균 15 HU로 확인되었으며, 치료계획과 측정된 선량을 비교하였을 때 9, 12 MeV 모든 측정 위치에서 1 % 이내 차이를 보였으며, 6 MV는 두 측정 위치에서 -1.53 %, -1.56 % 차이로 전체 2 % 내의 오차를 보였다. 세 번째 실험에서는 2주 동안 측정하였을 때 colloid gel의 선량변화가 1 % 내외로 측정되었다. 네 번째 실험에서는 치료계획과 EBT3 film으로 측정된 결과를 비교하였을 때 6 MV에서는 bolus, rice 모두 비슷한 선량 차이를 보였으며, 9 MeV에서는 photon과 달리 colloid gel이 bolus, rice와 비교하여 선량 차이가 적게 나는 것을 확인하였다. Dose profile 면에서도 colloid gel이 bolus, rice보다 균일한 dose 분포를 보였다. 결 론 : 본 연구에서 방사선치료를 위해 제작된 colloid gel의 밀도는 $1.02g/cm^3$로 물의 밀도와 비슷하며, 방사선치료 과정 동안 변질 및 변형이 확인되지 않았다. Colloid gel 제작 시 밀도에 유의를 해야 하지만, bolus, rice보다 환자의 체표면에 대한 충분한 보상을 통해 선량을 균일하게 전달할 수 있고, 저가에 제작을 할 수 있다는 점에서도 충분한 장점이 있다. 앞으로 임상적용을 위한 추가적인 실험 및 연구를 통해 방사선치료에 적용할 수 있을 것으로 사료된다.

  • PDF

졸-겔법에 의한 나노크기의 티탄-콜로이드 합성 및 인산염 피막 특성 (Synthesis of Nanosized Titanium-Colloid by Sol-Gel Method and Characterization of Zinc Phosphating)

  • 이만식;이선도
    • 한국표면공학회지
    • /
    • 제38권1호
    • /
    • pp.37-43
    • /
    • 2005
  • Nanosized titanium-colloid particles were prepared by sol-gel method. The physical properties, such as thermal stability, crystallite size and crystallinity according to synthesis condition have been investigated by TEM, XRD, SEM, TGA and DTA. In addition, Zinc phosphating has been studied in order to compare the phosphating characterization of prepared nanosized titanium-colloid particles. The major phase of all the prepared titanium-colloid particles was an amorphous structure regardless of synthesis temperature and the structure was composed of phoshate complex and titanium. The micrographs of HR- TEM showed that nanosized titanium-colloid particles possessed a spherical morphology with a narrow size distribution. The crystallite size of the titanium-colloid particles synthesized at 80℃ was 4-5 nm and increased to 8-10 nm with an increase of synthesis temperature (150℃). In addition, the coating weight increased with an increase of temperature of phosphating solution and when the concentration of titanium-colloid was 2.0 g/l, the coating weight was 1.0 g/㎡.

$^{99m}Tc$-colloid 섭취를 보인 췌장의 도세포종 : 증례보고 (Radiocolloid Uptake in the Pancreas Islet Cell Tumor: Case Report)

  • 양우진;정수교;연수경;신경섭;박용휘
    • 대한핵의학회지
    • /
    • 제28권1호
    • /
    • pp.145-147
    • /
    • 1994
  • Colloid uptake in various hepatic conditions such as focal nodular hyperplasia, regenerating nodules in the cirrhotic liver, hamartoma, hemangioma and rarely hepatoma has been documented. Extrahepatic tumors may show colloid uptake and they include splenic hemangioma, malignant fibrous histiocytoma, breast carcinoma and Kaposi's sarcoma. The mechanism of colloid uptake in those lesions is associated with phagocytic activity in or around the tumors. We report a pancreas islet cell tumor that showed colloid uptake on $^{99m}Tc$-phytate liver scan without histologic evidence of phagocytosis by tumor cells or infiltration of phagocytes in the tumor Microscopically the tumor was highly vascular and showed diffuse hemorrhage throughtout the tumor. We postulated that extravasation of the colloid into the tumor insterstitium caused nonspecific colloid uptake in this tumor. It is expected that hemorrhagic tumor may show nonspecific colloid uptake without phagocytosis in or about the lesion.

  • PDF

International Joint Research for the Colloid Formation and Migration in Grimsel Test Site: Current Status and Perspectives

  • Sang-Ho Lee;Jin-Seok Kim;Bong-Ju Kim;Jae-Kwang Lee;Seung Yeop Lee;Jang-Soon Kwon
    • 방사성폐기물학회지
    • /
    • 제20권4호
    • /
    • pp.455-468
    • /
    • 2022
  • Colloid Formation and Migration (CFM) project is being carried out within the Grimsel Test Site (GTS) Phase Ⅵ. Since 2008, the Korea Atomic Energy Research Institute (KAERI) has joined CFM to investigate the behavior of colloid-facilitated radionuclide transport in a generic Underground Research Laboratory (URL). The CFM project includes a long-term in-situ test (LIT) and an in-rock bentonite erosion test (i-BET) to assess the in-situ colloid-facilitated radionuclide transport through the bentonite erosion in the natural flow field. In the LIT experiment, radionuclide-containing compacted bentonite was equipped with a triple-packer system and then positioned at the borehole in the shear zone. It was observed that colloid transport was limited owing to the low swelling pressure and low hydraulic conductivity. Therefore, a postmortem analysis is being conducted to estimate the partial migration and diffusion of radionuclides. The i-BET experiment, that focuses more on bentonite erosion, was newly designed to assess colloid formation in another flow field. The i-BET experiment started with the placement of compacted bentonite rings in the double-packer system, and the hydraulic parameters and bentonite erosion have been monitored since December 2018.

림포신티그래피용 $^{99m}TC$를 표지황화안티몬 콜로이드 및 전분의 제조에 관한 연구 (Studies on the Preparation of $^{99m}TC$ Labelled Antimony Sulfide Colloid and Hydroxyethyl Starch for Lymphoscintigraphy)

  • 박경배;오옥두;김재록;임상무;홍성운
    • 대한핵의학회지
    • /
    • 제23권1호
    • /
    • pp.71-83
    • /
    • 1989
  • For the development of $^{99m}Tc-labelled$ antimony sulfide colloid and hydroxyethyl starch, various experiments such as preparation of colloid, control of the distribution of particle size, establishment of labelling conditions, determination of labelling yield and radiochemical purity, examination of stability, and organ imagings of rabbits etc. were carried out. 1) Antimony sulfide colloid was readily prepared by the reaction of aqueous solution of antimony potassium tartrate with hydrogen sulfide generated by treating ferrous sulfide with dilute sulfuric acid. The colloid could be stabilized by adding small amount of polyvinylpyrrolidone. 2) Electron microscopy analysis exhibited the distribution of colloid size in the range of $1\sim15nm$ with a major portion of 9 m. The colloid solution was sterilized by membrane filtration $(0.2{\mu}m)$ and then stored at $4^{\circ}C$. This sterilized colloid was so stable that it was usable at least for one year. 3) The antimony sulfide colloid was labelled by adding sodium $pertechnetate-^{99m}Tc$ solution to the reaction vial, followed by adding hydrochloric acid and then boiled for 30 min. The optimal pH of the reaction mixture was found to be in the range of $1.3\sim1.4$. Instant thin layer chromatography (ITLC) analysis showed high labelling yield of above 99.5%. This labelled colloid maintained high radio-chemical purity of above 99% until 10 hours after labelling. 4) Animal studies showed high uptake of $^{99m}Tc-Sb_2S_3$ colloid at lymph vessels and nodes indicating a suitable agent for lymphoscintigraphy. Satisfactory results were also abtained in other clinical studies. 5) Hydroxyethyl starch (HES $0.6\sim1.0%$) was labelled with $Na^{99m}TcO_4$ in the presence of $SnCl_2$ with high labelling yield of above 99.5%. The optimal pH of the reaction mixture was in the range of $1.8\sim2.0$. $^{99m}Tc-HES$ maintained high radiochemical purity of above 99% until 10 hours after labelling. 6) Animal studies showed that $^{99m}Tc-HES$ migrated more rapidly from the injection sites into the lymph vessels than $^{99m}Tc-Sb_2S_3$ colloid while less amount of the former was uptaken at lymph nodes than that of the latter. Similar phenomenon was also observed in other clinical studies. As a result, $^{99m}Tc-Sb_2S_3$ colloid was found to be more effective lymphoscintigraphic agent than $^{99m}Tc-HES$.

  • PDF

Radionuclide Transport Mediated by Pseudo-Colloid in the fractured Rock Media : Model Development

  • Baik, Min-Hoon;Hahn, Phil-Soo
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 춘계학술발표회논문집(2)
    • /
    • pp.769-774
    • /
    • 1995
  • In this study, a transport model was developed in order to analyze and predict the transport behaviors of radionuclides mediated by pseudo-colloid in the fractured rock media. It was resulted that the transport of Pu-239 was faster than Ni-63 because pseudo-colloid formation constant of Pu-239 was greater than that of Ni-63. Also, the effect of pseudo-colloid formation on the transport of a radionuclide was shown to be very significant when the apparent pseudo colloid formation constant, $K_{ap}(m^{3}/kg)$, was greater than 100. Thus, it can be concluded that acceleration of radionuclide migration may be occurred because the pseudo-colloid formation of radionuclides increases the amount of mobile components in the solution and consequently decreases the amount of radionuclides adsorbed on the stationary solid medium.

  • PDF

액중 전기선폭발법으로 제조된 구리 나노콜로이드의 특성 평가 (Evaluation of Cu nano-colloid prepared by electrical wire explosion in liquid phase)

  • 윤재철;양상선;유지훈
    • 한국입자에어로졸학회지
    • /
    • 제6권1호
    • /
    • pp.37-46
    • /
    • 2010
  • Cu nano-colloid was prepared by wire electric explosion process under de-mineralized water and anhydrous ethanol. To control the properties of Cu nano-colloid, experimental conditions such as diameter of Cu wire and applied voltage were changed. The optimal Cu nano-colloid was prepared when the 0.1mm diameter of Cu wire with the applied voltage of 2000 V was used. The shape of Cu particles in colloid was spherical and the XRD result revealed that the phase of Cu particles was cubic phase. About 20nm Cu nanoparticles with high crystallinity were successfully prepared using wire explosion process under anhydrous ethanol and they showed more than 100 hours dispersion stability.

유방암 환자의 전초림프절 검사에서 Tc-99m Tin-colloid와 Tc-99m Phytate의 효용성에 대한 비교 (Camparison of the Efficiency for Tc-99m Tin-colloid and Tc-99m Phytate in Sentinel Node Detection in Breast Cancer Patients)

  • 석주원;김인주
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권6호
    • /
    • pp.451-455
    • /
    • 2008
  • 목적 : 전초림프절 스캔과 전초림프철 생검은 유방암 환자에서 액와림프절 전이를 인지하기 위한 표준화된 방법으로 사용되게 되었지만, 표준화된 방사성의약품은 마련되어 있지 않다. 액와림프절 전이를 인지하기 위한 전초림프절 검사에 있어서 본 연구에서는 Tc-99m Tin-colloid와 Tc-99m Phytate의 결과를 비교하여 보았다. 대상 및 방법: 본 연구에서는 2001년에서 2008년까지 유방암으로 수술을 시행했던 381명의 환자를 대상으로 하였다. 349명의 환자는 Tc-99m Tin-colloid (37-185MBq) 0.8ml를 유륜하로 주사하였다. 33명의 환자는 Tc-99m Phytate (37-185 MBq) 0.8 ml를 유륜하로 주사하였다. 앉은 자세에서 림프신티그라피가 시행되었고, 수술 중에 감마프로브로 전초림프절을 발견하였다. 결과: Tc-99m Tin-celloid로 검사를 시행한 전체 349명의 환자 중에서 312명(89.4%)이 림프신티그라피에 의해 전초림프절이 발견되었고, 304명(87.1%)이 감마프로브에 의해 전초림프절이 발견되었다. 전날검사를 시행한 전체 33명의 환자 중에서 32명(97.0%)이 림프신티그라피에 의해 전초림프절이 발견되었고 33명(100%)이 감마프로브에 의해 전초림프절이 발견되었다. Tc-99m Phytate에 의한 림프신티그라피와 감마프로브에 의한 전초림프절 발견율은 Tc-99m Tin-celloid와 비교하여 통계학적으로 유의하게 높았다 (p<0.05, P<0.05). 결론: 유방암 환자에서 전초림프절을 발견하는데 있어 Tc-99m Phytate가 Tc-99m Tin-colloid보다 더 좋은 선택일 것이다.