• 제목/요약/키워드: Collimator lens

검색결과 40건 처리시간 0.028초

Opto-Mechanical Detailed Design of the G-CLEF Flexure Control Camera

  • Jae Sok Oh;Chan Park;Kang-Min Kim;Heeyoung Oh;UeeJeong Jeong;Moo-Young Chun;Young Sam Yu;Sungho Lee;Jeong-Gyun Jang;Bi-Ho Jang;Sung-Joon Park;Jihun Kim;Yunjong Kim;Andrew Szentgyorgyi;Stuart McMuldroch;William Podgorski;Ian Evans;Mark Mueller;Alan Uomoto;Jeffrey Crane;Tyson Hare
    • 천문학회지
    • /
    • 제56권2호
    • /
    • pp.169-185
    • /
    • 2023
  • The GMT-Consortium Large Earth Finder (G-CLEF) is the first instrument for the Giant Magellan Telescope (GMT). G-CLEF is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. G-CLEF Flexure Control Camera (FCC) is included as a part in G-CLEF Front End Assembly (GCFEA), which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within GCFEA. FCC consists of an optical bench on which five optical components are installed. The order of the optical train is: a collimator, neutral density filters, a focus analyzer, a reimager and a detector (Andor iKon-L 936 CCD camera). The collimator consists of a triplet lens and receives the beam reflected by a fiber mirror. The neutral density filters make it possible a broad range star brightness as a target or a guide. The focus analyzer is used to measure a focus offset. The reimager focuses the beam from the collimator onto the CCD detector focal plane. The detector module includes a linear translator and a field de-rotator. We performed thermoelastic stress analysis for lenses and their mounts to confirm the physical safety of the lens materials. We also conducted the global structure analysis for various gravitational orientations to verify the image stability requirement during the operation of the telescope and the instrument. In this article, we present the opto-mechanical detailed design of G-CLEF FCC and describe the consequence of the numerical finite element analyses for the design.

안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가 (Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit)

  • 곽용국;홍순기;하민용;박장필;유숙현;조웅
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.87-95
    • /
    • 2015
  • 목 적 : 안와 주변 방사선 치료 시 수정체 피폭선량감소를 위하여 사용된 2차 차폐 block의 유용성을 알아보고자 한다. 대상 및 방법 : Human phantom(Alderson Rando Phantom, The Phantom Laboratory, USA)을 사용하여 CT(Somatom Definition AS, Siemens, Germany) 모의촬영 후 전산화치료계획시스템(Pinnacle, PHILIPS, USA)을 통해 실제 치료와 유사한 IMRT치료계획을 실시하였다. 2차 차폐를 위하여 두께 3mm 지름 25 mm의 납판과 3 mm tungsten eye-shield block(Extra small size, Radiation Products Design, Inc, USA)를 사용하였으며, TPS(Treatment Planning System) 상의 lens dose와 모의치료 상의 lens dose를 OSLD로 측정 비교하였다. 또한, 5 cm 두께의 acrylic phantom에 동일한 조건의 2차 차폐물인 3 mm 납판과 tungsten eye-shield block을 사용하여 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$)를 조사 및 측정하였으며, 조사야 밖의 누설선 및 투과방사선 영향을 제한시키고자 8 cm 납블럭(O.S.B: Outside Scatter Block)을 적용하여 위와 동일한 실험을 시행하였다. 조사야로부터 1 cm 이격하여 phantom 끝 옆면에 OSLD(Optically Stimulated Luminescence Dosimeter)를 부착하였고, eyelid의 두께에 해당하는 bolus 3 mm를 적용하였다. 결 과 : human phantom을 이용하여 IMRT 치료계획 상의 Lens dose와 실 측정치는 각각 315.9, 216.7 cGy가 측정되었고, 3 mm 납판과 tungsten eye-shield block으로 2차 차폐 후 각각 234.3, 224.1 cGy가 측정되었다. acrylic phantom을 이용한 실험 결과는 no block, 3 mm 납판, tungsten eye-shield block을 사용했을 때 5.24, 5.42, 5.39 cGy가 측정되었으며, 조사야 밖에 O.S.B를 적용하여 no block, 3 mm 납판, tungsten eye-shield block을 실험한 결과 각각 1.79, 2.00, 2.02 cGy가 측정되었다. 결 론 : 광자선 조사 시 critical organ을 보호하기 위하여 2차 차폐를 적용할 시에는 field 외부일지라도 헤드 누설방사선 및 collimator & MLC 투과방사선이 존재하므로 치료부위와 beam 방향에 따라 금속과 같은 높은 원자번호의 차폐물질이 critical organ근처에 있다면 선량 증가의 원인이 될 수 있다는 사실을 알 수 있었다. 따라서 피폭선량 감소를 위한 2차 차폐의 시도는 분명 의미가 있었으나 미 검증된 시도는 오히려 역효과를 가져올 수 있다는 사실을 인지하여 QA를 통해 목적에 부합하는 결과가 나오는지를 사전에 알아보아야 할 것이다.

  • PDF

비인두암 Vertical MLC VMAT plan 유용성 평가 (Evaluating efficiency of Vertical MLC VMAT plan for naso-pharyngeal carcinoma)

  • 채승훈;손상준;이제희
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.127-135
    • /
    • 2021
  • 목 적 : 비인두암 VMAT 치료 시 콜리메이터 각도 273°와 350°를 사용한 2회전 치료계획(Vertical MLC VMAT plan, 이하 VMV plan)과 콜리메이터 각도 20°와 340°를 사용한 2회전 치료계획(Complemental MLC VMAT plan, 이하 CMV plan)과의 비교 분석을 통해 유용성을 평가해 보고자 한다. 대상 및 방법 : 본원에서 VMAT 치료를 받은 비인두암 환자 30명을 대상으로 하였다. 전산화치료계획은 Eclipse, PO, AcurosXB 알고리즘을 이용하였으며, 치료기는 Vital-beam을 사용하였다. 치료계획은 갠트리 회전반경이 각각 360°인 두 개의 회전(Arc)을 6MV를 이용하여 생성하고, 콜리메이터 각도 변화에 의한 영향을 확인하기 위해 273°와 350°로 설정한 VMV plan과 20°와 340°로 설정한 CMV plan을 수립하였다. 선량용적 히스토그램에서 확인 및 산출된 계획표적용적(PTV)과 결정장기(OAR)들의 선량지표들과 변조복잡성지수(MCSv), MU, 치료시간에 대해 기술통계 및 대응표본 t-검정을 실시하였다. 그리고 대상별로 두 치료계획의 MCSv의 차이와 각각의 평가지표들의 차이 간 상관관계가 있는지 확인하기 위해 피어슨의 상관관계 분석을 실시하였다. 결 과 : PTV 평가 지표의 경우, VMV Plan에서 PTV_67.5의 CI가 3.76% 개선되었으며, OAR의 경우 척수(-14.05%)와 뇌 줄기(-9.34%)의 선량감소 효과가 두드러지게 나타났다. 그리고 귀밑샘들(왼쪽 : -5.38%, 오른쪽 : -5.97%)과, 시각기관들(왼쪽 시신경 : -4.88%, 오른쪽 시신경 : -5.80%, 시신경교차 : -6.12%, 왼쪽 수정체 : -6.12%, 오른쪽 수정체 : -5.26%), 청각기관(왼쪽 : -11.74%, 오른쪽 : -12.31%)과 갑상샘(-2.02%)에서의 선량감소효과도 확인할 수가 있었다. 또한 MCSv가 VMV Plan에서 5.31% 높게 나왔으며, MU의 경우에 6.11% 낮은 것으로 나타났다. 그리고 두 치료계획의 MCSv의 차이는 PTV_54의 CI(r=-0.55)의 차이, PTV_48의 CI(r=-0.43)의 차이와 유의한 음(-)의 상관관계를 보였고, 척수(r=0.40), 뇌줄기(r=0.34), 양쪽 침샘들(왼쪽 : r=0.36, 오른쪽 : r=0.37)의 차이와 양(+)의 상관관계를 보였다. 이는 VMV plan의 moluation 복잡성이 CMV plan에 비해 상대적으로 높아 질 때, PTV_54, 48의 CI 개선 및 척수, 뇌줄기, 양쪽침샘들의 선량 감소 효과가 커지는 것을 의미하며, 이러한 분석결과들을 바탕으로 VMV plan의 modulation에 대한 효율성이 CMV plan 보다 크다는 것을 확인할 수 있었다. (위 모든 값에 대해 유의수준은 p<.05) 결 론 : VMV Plan은 CMV plan과 비교하여 MLC가 더 효율적으로 modulation할 수 있도록 함으로써, 치료계획의 질을 향상 시키는데 도움이 될 것이라 사료된다.

선형가속기형 방사선수술시 인형 팬텀에서 수정체 및 갑상선 선량 (Radiation Dose of Lens and Thyroid in Linac-based Radiosurgery in Humanoid Phantom)

  • 김대용;김일한
    • Radiation Oncology Journal
    • /
    • 제16권4호
    • /
    • pp.517-529
    • /
    • 1998
  • 목적 : 정위방사선수술은 뇌동정맥기형 및 청신경초종, 뇌수막종양, 뇌하수체종양 뿐만 아니라 단일 전이성 종양의 치료에 있어서도 그 이용의 빈도가 급격히 늘어나는 추세이다. 그에 따라 목표부위에 있어서 정위방사선술의 선량분포에 관한 연구는 많이 발표되고 있으나 두 개강 외의 수정체 갑상선과 같이 방사선의 결정적 또는 확률적 효과에 민감한 장기와 같은 조직에서 흡수되는 선량에 관한 자료는 극히 제한적이다. 본 연구는 인체모형에서 방사선수술시 수정체 및 갑상선의 선량을 측정하고 그 선량에 영향을 미치는 변수를 규명하고자 하였다. 대상 및 방법 : 6 곳의 상이한 회전중심점에서 각각 서울대학교 의과대학 치료방사선과학교실에서 개발한 선형가속기형 정위방사선수술 기법을 이용하여 치료계획을 세웠다. 각 회전중심점당 6개의 arc를 기본으로 하고 각 arc의 범위는 100도를 기준으로 하고 보조콜리메이터 크기는 직경 2cm로 선정하였다. 각 arc 별로 250cGy 조사한 후 내회 열형광선량계를 이용하여 수정체 및 갑상선의 표면에 미치는 선량을 측정하였다. 결과 : 회전중심점 또는 arc plane 이 각 장기와 가까울수록 흡수 선량이 높았다. exit beam이 수정체나 갑상선을 지나지 않을 경우 각 장기의 선량은 최대선량의 0.23$\pm$0.08$\%$ 와 0.18$\pm$0.05$\%$ 이고, exit beam 이 수정체나 갑상선을 지나는 경우 각 장기의 선량은 최대선량의 0.76$\pm$0.12$\%$ 와 0.41$\pm$0.04$\%$ 이다. exit beam의 통과 여부가 각 장기의 선량에 미치는 가장 큰 인자이며, 장기를 통과하는 arc에 의해 흡수하는 선량은 총 선량의 80$\%$를 차지한다. 인체 모형의 표면선량과 5mm 깊이에서의 선량에 큰 차이가 없어 표면선량을 수정체 및 갑상선 선량으로 대체할 수 있다고 판단한다. 결론 : 정위방사선수술시 인체모형의 수정체와 갑상선에 흡수되는 방사선량을 측정한 결과 회전중심점 및 arc plane 이 각 장기와 가까울수록 높은 흡수 선량을 나타내었으며, exit beam이 수정체나 갑상선을 통과하는 경우 흡수선량이 높았고 exit beam의 통과 여부가 각 장기의 흡수선량에 가장 큰 영향을 미쳤다. 또한 수정체와 갑상선의 표면선량은 수정체 및 갑상선 선량과 큰 차이가 없었다. 최적의 방사선수술을 위한 계획을 수립할 경우 각 장기의 선량은 최대 1$\%$ 미만으로 후유증을 일으키기에 낮은 선량이기는 하나, 특히 소아 등에서는 갑상선 선량을 가능한 낮추어야 할 것이다.

  • PDF

각이등분법 및 평행법에 의한 전악 구내 표준 촬영시 두경부 피부 흡수선량 비교 (SKIN ABSORBED DOSES FROM FULL MOUTH STANDARD INTRAORAL RADIOGRAPHY IN BISECTING ANGLE AND PARALLELING TECHNIQUES)

  • 김애지;나경수;도시홍;김현자;유명진
    • 치과방사선
    • /
    • 제20권2호
    • /
    • pp.315-333
    • /
    • 1990
  • This study was performed to measure the skin absorbed doses from full mouth standard intraoral radiography (l4 exposures) in bisecting angle and paralleling techniques. Thermoluminescent dosimeters were used in a phantom. Circular tube collimator(60㎜ in diameter, 20㎝ in length) and rectangular collimator(35㎜ × 44㎜, 40㎝ in length) were set for bisecting angle and paralleling techniques respectively. All measurement sites were classified into 8 groups according to distance from each point of central rays. The results were as follows: 1. The skin absorbed doses from the paralleling technique were significantly decreased than those from the bisecting technique in both points at central ray and points away from central ray. The percentage rates of decrease were greater at points away from central ray than those at central ray. 2. The skin absorbed doses at the lens of eye, parotid gland, submandibular gland and thyroid region were significantly decreased in paralleling techniuqe, but those of the midline of palate remained similar in both techniques. 3. The highest doses were measured at the site 20mm above the point of central ray for the mandibular premolars in bisecting angle technique and at the point of central ray for the mandibular premolars in paralleling techniques. The lowest doses were measured at the thyroid region in both techniques.

  • PDF

대기오염 연구용 이동형 LIDAR 광학계 설계 (Optical system design of a mobile LIDAR for air polution research)

  • 홍경희
    • 한국광학회지
    • /
    • 제7권3호
    • /
    • pp.191-195
    • /
    • 1996
  • 대기오염 연구용 이동형 라이다의 광계통을 설계하였다. 대기오염이나 오종층의 측정을 위해 라이다를 사용하며 군에서는 화생방 오염 측정에도 사용된다. 역 Cassegrain형의 시준기로 평행광을 만들어 평면경에 의해 전송하는 레이저광속과 수신 망원경의 광축이 일치하게 된다. 레이저광속은 대기로 향하여 전송되며 측정하고자 하는 물질에 의해 산란되어 수신 망원경으로 되돌아 온다. 주사반사경은 수직으로 60.deg. 수평으로 180.deg.회전되며 주사한다. 주사반사경은 수신망원경과 분리되어 자동차 지붕위에 설치된다. 수신된 레이저광은 공간주파수 여과기에 의해 여과되고, fabri렌즈에 의해 평행광으로 되어 광속분리기에 의해 2개의 광속으로 나뉘어 검출된다. 각 레이저광은 PM관에 의해 검출되어 증폭되고 분석된다.

  • PDF

흘로그램 간섭계를 이용한 광픽업 베이스의 미소 열변형 측정 (Measurement of Micro Thermal Deformation of Optical Pick-up Base Using Holographic Interferometry)

  • 서영민;강신일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.191-194
    • /
    • 2002
  • In optical pick-up, optical components such as objective lens, collimator, mirror, laser diode and photo diode are mounted on the pick-up base. These components must keep their original position during operation for proper transmittance of information from laser diode to optical disk and back to photo diode. However, micro thermal deformation of pick-up base which is induced by thermal environment during operation can deteriorate the performance of optical pick-up. Therefore, it is important to measure and analyze the thermal deformation behavior of pick-up base under thermal environment. In the present study, a measurement system using holographic interferometry was designed to measure micro thermal deformation of pick up base. The measurement system was verified by using the deformation of cantilever with prescribed motion actuated by PZT with 1 nm resolution. Interferometric measurement was compared quantitatively with that induced by PZT actuator. Finally, micro thermal deformation of pick-up base under actual thermal environment was measured using the present holographic interferometry and the results were analysed.

  • PDF

Ebert-Fastie spectrograph using the Transformable Reflective Telescope kit

  • Ahn, Hojae;Mo, Gyuchan;Jung, Hyeonwoo;Choi, Junwhan;Kwon, Dou Yoon;Lee, Minseon;Kim, Dohoon;Lee, Sumin;Park, Woojin;Lee, Ho;Park, Kiehyun;Kim, Hyunjong;Pak, Soojong
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.40.4-40.4
    • /
    • 2020
  • Kyung Hee university invented the Transformable Reflective Telescope (TRT) for optical experiment and education. The TRT kit can transform into three optical configurations from Newtonian to Cassegrain to Gregorian by exchanging the secondary mirror. We designed the Ebert-Fastie spectrograph as an extension of the TRT kit. The primary mirror of the TRT kit serves as both collimator and camera lens, and the reflective grating as the dispersing element is placed along the optical axis of the primary mirror. We designed and fabricated the grating holder and the source units using 3D printer. Baffle was also fabricated to suppress the stray light, which was reduced by 83%. The spectrograph can observe the optical wavelength range (4000Å~7000Å). Measured resolving power (R=λ/Δλ) was ~700 with slit width of 0.18mm. The spectrograph is optimized for f/24, and the spectral pixel scale is 0.49Å/pixel with Canon 550D detector. We present the sample spectra of discharged Ne, Ar and Kr gases. The flexible setting and high performance make this spectrograph a useful tool for education and experiment.

  • PDF

Tungsten eyeball shield block의 임상적용에 관한 고찰 (Dosimetric characteristics of an independent collimator system using measurements performed quarter fields.)

  • 정덕양;이병구;황웅구
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.89-94
    • /
    • 2002
  • I. 목적 : Sebaceous gland carcinoma, Squamouse cell ca., basal cell ca., low grade MALToma 등에서 전자선을 이용하여 eyelid 치료시 안구의 선량은 될 수 있는 한 최소선량으로 관리되어야 한다. 그러나 upper나 lower eyelid 전부를 포함하는 조사면은 치료후 백내장등의 심각한 부작용을 만들어 낼 수 있다. 본원에서는 상용되는 Tungsten eyeball shielding block과 기존의 lead block에 의한 차폐시 안구의 선량을 비교하여 Tungsten eyeball shielding block의 유용성에 대해 평가해 보고자한다. 2. 재료 및 방법: 시판되고 있는 BOLX-I 물질을 이용하여 모형안구를 제작하고 안구의 6곳 주요지점을 선정한 후 TLD chip을 이용하여 주로 사용되는 6MeV와 9MeV electron beam의 선량을 측정, Tungsten eyeball shielding block과 lead block의 선량을 비교하였다. 3. 결과 : Tungsten eyeball shielding block의 사용이 안구의 주요 지점인 각막, 망막, 시신경부위의 선량을 lead block사용 때보다 $90\%$에서 $50\%$의 감소효과가 있었다. 4. 결론 : Tungsten eyeball shielding block은 6MeV 전자선 치료시 보다 뛰어난 차폐효과를 보여 임상에서의 유용성이 인정되었다. 그러나 안구에 삽입시 환자의 고통과 불쾌감을 줄일 수 있는 방안이 모색되어야 하는 숙제를 남겼다.

  • PDF

적외선 광학계용 MTF 측정장치 개발 (Development of a MTF Measurement System for an Infrared Optical System)

  • 손병호;이회윤;송재봉;양호순;이윤우
    • 한국광학회지
    • /
    • 제26권3호
    • /
    • pp.162-167
    • /
    • 2015
  • 본 논문에서는 적외선 파장대에서 렌즈의 변조전달함수(MTF)를 칼날 주사방식으로 측정하는 적외선 MTF 측정장치를 구성하고 평가하였다. 측정장치는 물체부, 평행광을 만들어주는 시준부, 형성된 상을 분석하는 분석부로 나뉜다. 광원으로는 텅스텐 필라멘트 광원을 사용하였으며 중적외선 영상을 검출하기 위해 MCT를 사용하였다. 이 장치를 사용하여 ZnSe 재질의 f 수가 5인 표준렌즈의 MTF를 중적외선 파장대인 $3{\sim}5{\mu}m$에서 측정하고 Zemax 프로그램을 통해 계산한 이론값과 측정값 차이를 비교하여 차단주파수(Cut-off frequency)인 50 1/mm까지 전구간에서 ${\pm}0.035$이내임을 확인하였다. 또한 측정값의 신뢰도를 확인하기 위한 A형 측정불확도를 계산한 결과 MTF의 대표 공간 주파수인 20 1/mm에서 0.002으로 동일한 조건 하에서 측정 시 측정값의 변화가 거의 없음을 알 수 있었다.