• 제목/요약/키워드: Collimator

검색결과 491건 처리시간 0.03초

X선촬영실 내에서의 공간산란선량 변동에 관한 연구 (A Study on the Behavior of the Free Space Scatter dose in X-ray Diagnostic Room)

  • 오현주;김성수;김영일;임한영;김흥태;이후민;김학성;이상석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제17권2호
    • /
    • pp.21-27
    • /
    • 1994
  • In this pauper, when the X-ray exposure condition is 70, 90, 110 kV, 10 mAs, FFD 180 cm, FSO $10{\times}10$, $35{\times}35\;cm$, toward the $36{\times}36{\times}15\;cm$ acryl phantom, the free space scatter dose rate at the 15th points in X-ray diagnostic room was measured by electrometer and 1800 co ionization chamber. Therefore, the free space scatter dose distribution profile was drown, and then, the free space scatter dose contribution percentage was Investigated. The obtained results are summarized as following. 1. The X-ray tube leakage dose rate of the experiment generator at the 1 m from focus was measured maximum 85 mR/hr, minimum 20 mR/hr, therefore, this values was appeared below the KS rules, 2. The free space scatter dose become to larger at the primary X-ray beam around area, and lower at the back ward X-ray tube. The maximum values were 3,812 mR/hr at the front Lt 1 m $45^{\circ}$ point, minimum 117 mR/hr at the back ward 1 m $180^{\circ}C$ point. 3. As the more tube voltage and field size increase, the more free space scatter dose contribution percentage become to increase, as to 90 kV from 70 kV, increase to 12 %, to 110 kV from 90 kV, increase to 18 %, and then, become to 11 % at the $10{\times}10\;cm$ and 87 % at the $35{\times}35\;cm$. 4. The 89 % of the total producted scatter ray occured from acryl phantom, at the X-ray tube housing 6 %, at the front side back wall 5 %. 5. The free space scatter dose contribution percentage at the one point build up 80 % from the phanton direction, 14 % from the X-ray tube and collimator direction, 2.2 % from the front wall, 1.8 % from the side wall, 1.7 % the back wall.

  • PDF

다중 슬릿 즉발감마선 카메라를 위한 이중모드 신호처리 모듈 개발 (Development of Dual-mode Signal Processing Module for Multi-slit Prompt-gamma Camera)

  • 박종훈;이한림;김성훈;김찬형;신동호;이세병;정종휘
    • 한국의학물리학회지:의학물리
    • /
    • 제27권1호
    • /
    • pp.37-45
    • /
    • 2016
  • 양성자 치료 시 양성자 빔의 특성을 이용하여 치료 부위에 국부적인 선량을 부여하고 정상조직에 불필요한 선량을 줄이기 위해서는 인체 내 양성자 빔의 비정을 실시간으로 확인하는 것이 중요하다. 이를 위해 본 연구팀은 24개의 섬광검출기 배열 및 24채널의 신호 처리 시스템으로 구성된 즉발감마선 카메라 모듈을 개발하고 있다. 본 연구에서는 다채널의 섬광 검출기 신호를 처리하기 위하여 이중모드 다채널 신호 처리 모듈을 개발하여 그 성능을 평가해보았다. 성능을 평가한 결과 에너지 교정 모드를 통해 다채널의 섬광검출기에 대하여 동시에 에너지 교정이 가능함을 확인하였고, 이를 통하여 정확하게 3 MeV에 해당하는 측정 하한 값을 결정할 수 있었다. 고속 데이터 획득 모드를 통해 45 MeV 양성자 빔에서 발생한 즉발감마선 분포를 측정한 결과 $3{\times}10^9$개의 양성자 빔에서도 양성자 선량 분포와 유사한 결과를 얻을 수 있었고, 빔 비정을 평가한 결과 $17.13{\pm}0.76mm$로 EBT film을 통하여 측정한 비정인 16.15 mm와 굉장히 밀접한 관련이 있음을 확인하였다.

좌측 유방 방사선치료를 위한 역치료계획의 세기변조방사선치료와 다중빔조사영역치료기법 사이의 포괄적 선량측정 분석 (A Comprehensive Dosimetric Analysis of Inverse Planned Intensity Modulated Radiation Therapy and Multistatic Fields Technique for Left Breast Radiotherapy)

  • 문성권;윤선민
    • Radiation Oncology Journal
    • /
    • 제28권1호
    • /
    • pp.39-49
    • /
    • 2010
  • 목 적: 좌측 유방의 방사선치료에 있어, 3 빔 또는 5 빔을 이용한 세기변조방사선치료(intensity modulated radiation therapy, IMRT)와 다중빔조사영역 치료기법(multistatic fields techniques, MSF) 사이의 선량학적 차이를 분석하고자 하였다. 대상 및 방법: 개선된 선량 균일성을 만들 수 있는 가능성을 지닌 두 종류의 방사선치료 기술을 서로 비교 분석하였다. 첫째, 다중빔조사영역치료로 주조사야와 소조사야를 동시에 사용하여 치료하였다. 둘째, 고정된 다엽 조준기를 사용하는 IMRT로, 3 빔 또는 5 빔을 이용하였다. 유방보존술 후 방사선치료를 받은 16명의 초기 좌측 유방암 환자들을 대상으로 방사선치료계획들을 세운 다음, 이들을 선량학적 측면에서 비교 분석하였다. 결 과: $V_{95}$와 선량균일지수의 평균값은, 이 세 치료 사이에 통계학적으로 유의한 차이가 없었다. 방사선처방선량의 110% 이상을 받는 극심한 열점은 세 치료 모두에서 관찰되지 않았다. 동측 폐와 심장의 피폭 선량측정인자들에 대한 Tukey 검정에서, 세기변조방사선치료가 다중빔조사영역치료에 비해 저선량 영역의 피폭 선량을 유의하게 증가시킨 반면, 오히려 고선량 영역에서는 다중빔조사영역치료가 방사선 피폭을 약간 증가시켰다. 결 론: 선량 균일성 개선을 위해, 통상적인 쐐기기법 대신, 세기변조방사선치료보다 쉽게 계획되고 실시 될 수 있는 다중빔조사영역치료의 적용은 초기 좌측 유방암의 방사선치료 기술로 적합하다고 생각한다.

대퇴골의 전장검사 시 stitching method의 적용에 관한 유용성 연구 (A Study on Useful Application of Stitching Method for Full-Length Examination of the Femur)

  • 노지숙;정지훈;김성길;정명진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권2호
    • /
    • pp.97-103
    • /
    • 2011
  • 대퇴골의 전장검사 시 조사야의 넓이와 필름이나 검출기 등의 크기의 한계로 인하여 대각선 방향으로 위치를 잡는다 하여도 모두 포함되지 못하는 경우가 있다. 본 연구에서는 대퇴골의 골첨부와 골단부가 포함되도록 두 번 촬영을 하여 얻어진 영상을 융합하는 방식을 적용하여 검사한 결과에 대한 유용성에 대해 알아보고자 하였다. 2007년 8월부터 2009년 11월까지 광주지역의 한 대학병원 응급실에 내원한 환자 중 대퇴골 검사 시 고식적인 DR방식과 SM방식을 이용한 검사방법 모두를 시행한 경험이 있는 방사선사 30명을 대상으로 설문조사를 하였고, 같은 기간에 대퇴골검사를 시행한 환자의 영상의 질 평가는 영상의학과 전문의 2명과 10년 이상 근무한 방사선사 6명에 의해 대퇴경의 축소여부, 무릎관절의 회전여부, 대퇴골의 포함정도에 따라 20개의 영상을 평가하였다. 설문조사한 결과는 검사시간, 검사자수, 체력적 소모, 재 촬영률, 환자의 불편 등에 대한 항목에서 SM방식의 검사에서 모두 높은 점수를 받았고, 통계적으로 유의함을 알 수 있었으며(p < 0.001), 영상의 평가에서도 고식적인 DR방식보다 SM방식의 영상이 높은 평가점수를 받았다. 본 연구의 결과로 대퇴골 검사 시 SM방식이 고식적인 DR방식에 비하여 유용함을 알 수 있었다.

악성 골 및 연부조직 종양에서 Tl-201 SCAN의 진단적 효능 - Tc-99m-MIBI 및 Tc-99m-MDP scan과의 비교 - (Thallium-201 Scan in Bone and Softtissue Sarcoma - Comparison with Tc-99m-MIBI and Tc-99m-MDP Scan -)

  • 신덕섭;조인호;안종철;안면환;이상호
    • 대한골관절종양학회지
    • /
    • 제2권1호
    • /
    • pp.1-7
    • /
    • 1996
  • PURPOSE : The purpose of this study is to know the ability of detecting malignant tumor tissue by Tl-201 scan, and to compare with that of Tc-99m-MIBI and Tc-99m-MDP scan. MATERIAL AND METHODS : Between February 1994 and December 1995,38 unselected patients with various bone pathologies were studied prospectively. Eighteen had malignant bone and soft tissue pathologies, while twenty had benign. All patients were studied with Tl-201, Tc-99mMIBI and Tc-99m-MDP scan prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator was used for scanning. To avoid the interaction of isotope, the early(30min.) and delayed phase(3hrs.) of Tl-20l scan was performed first and Tc-99m-MIBI scan was performed after 30 minutes, and then Tc-99m-MDP scan 48 hours later. The scan images were visually evaluated by a blinded nuclear medicine physician. We could find true positive, true negative, false positive and false negative by the comparison of results with those of biopsy. We calculated positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%) of each scan. RESULT : The results of each scan were 85.7, 100, 100, 85, 92.1% in Tl-201, 81, 94.1, 94.4, 80, 86.8% in Tc-99m-MIBI and 50, 66.7, 88.9, 20, 52.6% in Tc-99m-MDP scan. As a conclusion, Tl-201 scan was the most specific and accurate method for detecting malignant tumor tissue. Tc-99m-MIBI scan was also good for malignant tumor searching. CONCLUSION : With our results, we can use Tl-201 scan to differentiate benign from malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

운동성 장애에 대한 감마나이프 시술의 초기경험 (Preliminary Report of Gamma Knife Radiosurgery for the Movement Disorders)

  • 홍준기;김무성;이선일;정용태;김수천;심재홍
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권8호
    • /
    • pp.1024-1029
    • /
    • 2000
  • Objectives : With recent improvements in neuroimaging and the development of third and fourth-generation radiosurgical dose-planning soft ware, came a renewed interest in using radiosurgery for the treatment of movement disorders. Radiosurgery involves no opening of the cranium and no incisions, eliminating both the risk of hemorrhage from passing an electrode to the depths of meningitis from operative infection. It is for these reasons stereotactic radiosurgical treatment of movement disorders has value in a small subgroup of patients. The authors report four cases of Parkinson's disease and one case of dystonia that were treated by Gamma knife. Methods : Radiosurgical nucleus ventralis intermedius thalamotomy using the gamma knife unit was performed to make lesion in two Parkinson's disease patients. A radiation dose of 120Gy was delivered to nucleus using a single 4-mm collimator plug pattern following classic anatomical landmarks. Patients were followed for a median of 10.5 months(range 9-12 months). An independent neurological evaluation of tremor, based on the change in the United Parkinson's Disease Rating Scale tremor score(UPDRS), was correlated with a subjective evaluation. Gamma knife ventrolateral(V.O.P) thalamotomy was performed in one case of dystonia. A central dose of 150Gy was delivered and the patient was followed for 18 months. Gamma knife globus pallidus interna pallidotomy was performed in two Parkinson's disease patients. A radiation dose of 130Gy(range 120-140Gy) was delivered. Patients were followed for a median of 13 months(range 9-14 months). Result : Ventrolateral thalamotomy in dystonia produced regained left hand usage in order to be able to use the telephone. Ventralis intermedius thalamotomy produced an excellent improvement of the tremor in one case, mild improvement of the tremor in the other case of Parkinson's disease. A globus pallidus internalis(GPi) pallidotomy produced improvement of rigidity and dyskinesia : one other showed no change. There were no neurological complications. Conclusion : Gamma Knife thalamotomy considered a safe and effective technique for the treatment of tremor in Parkinson's disease. Although the results from Longer follow-up is not available yet, the short-term results seem to be encouraging.

  • PDF

The Treatment Outcome of Elderly Patients with Idiopathic Trigeminal Neuralgia : Micro-Vascular Decompression versus Gamma Knife Radiosurgery

  • Oh, In-Ho;Choi, Seok-Keun;Park, Bong-Jin;Kim, Tae-Sung;Rhee, Bong-Arm;Lim, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권4호
    • /
    • pp.199-204
    • /
    • 2008
  • Objective : This study was designed to compare the efficacy of micro-vascular decompression (MVD) and Gamma knife radiosurgery (GKRS) for elderly idiopathic trigeminal neuralgia patients by analyzing the clinical outcome. Methods : In the past 10 years, 27 elderly patients were treated with MVD while 18 patients were treated with GKRS (>65-years-old). We reviewed their clinical characteristics and clinical courses after treatment as well as the treatment outcomes. For patients who were treated with MVD, additional treatment methods such as rhizotomy were combined in some areas. In GKRS, we radiated the root entry zone (REZ) with the mean maximum dose of 77.8 (70-84.3) Gy and one 4 mm collimator. Results : The mean age was 68.1 years for MVD, and 71.1 years for GKS group. The average time interval between first presenting symptom and surgery was 84.1 (1-361) months, and 51.4 (1-120) months, respectively. The mean follow-up period after the surgery was 35.9 months for MVD, and 33.1 months for GKRS. According to Pain Intensity Scale, MVD group showed better prognosis with 17 (63%) cases in grade I-II versus 10 (55.6%) cases in GKRS group after the treatment. The pain recurrence rate during follow up did not show much difference with 3 (11.1%) in MVD, and 2 (11.1%) in GKRS. After the treatment, 2 cases of facial numbness, and 1 case each of herpes zoster, cerebrospinal fluid (CSF) leakage, hearing disturbance, and subdural hematoma occurred in MVD Group. In GKRS, there was 1 (5.6%) case of dysesthesia but was not permanent. Three cases were retreated by GKRS but the prognosis was not as good as when the surgery was used as primary treatment, with 1 case of grade I-II, and 1 case of recurrence. The maximal relieve of pain was seen just after surgery in MVD group, and 1 year after treatment in GKRS group. Conclusion : For trigeminal neuralgia patients with advanced age, MVD showed advantages in immediately relieving the pain. However, in overall, GKRS was preferable, despite the delayed pain relief, due to the lower rate of surgical complications that arise owing to the old age.

정위적 방사선 수술에서의 이상표적모델과 경험적 지식을 활용한 수술계획 최적화 방법 개발 (Development of Ideal Model Based Optimization Procedure with Heuristic Knowledge)

  • 오승종;송주영;최경식;김문찬;이태규;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.84-93
    • /
    • 2004
  • 정위적 방사선수술(stereotactic radiosurgery, SRS)은 정위적 기구를 이용해 환자를 고정시킨 후 한번에 고선량의 방사선을 병변에 조사하는 방사선 치료법이다. 일반적인 방사선 치료와 달리 단 한번의 조사로 고선량의 방사선이 환자에게 주어지므로 정확한 수술계획의 수립이 필요하다. 현재, 수술계획은 사람이 직접 시행착오를 거듭하며 수립되고 있다. 이로 인해 계획의 재연성과 신뢰성에 문제가 재기되고 있으며, 이를 해결하고자 컴퓨터를 활용한 수술계획 최적화 방법들이 제안되어 왔다. 그러나 기존의 방법들은 최종적인 수출계획을 얻을 때까지 많은 시간이 필요하고 사용되는 수학적 알고리듬의 한계로 국소적 최적해를 최종해로 산출해 낼 위험성을 가지고 있다. 이를 해결하기 위해 이상표적모델을 활용한 정위적 방사선수술계획 최적화 방법을 연구하였다. 병소의 다양한 모양을 근사시킬 이상표적모델을 구형과 원통형, 원뿔형, 타원체의 4종류 가정하였다. 회전중심점(isocenter)을 여러 개 사용하여 이상표적모델을 50% 등선량 내에 포함시키고, 이 조건을 만족하는 경우의 회전중심점의 위치, 콜리메이터 크기를 데이터베이스화 하였다. 병소가 주어질 경우 기하학적 비교를 통해 병소의 모양을 가장 잘 나타낼 수 있는 이상표적모델, 또는 이상표적모델의 조합을 결정한 후 병소를 근사화하는 과정을 개발하였다. 이후 각 이상표적모델에 대해 데이터베이스에 구축되어 있는 최적변수들을 찾아 회전중심점을 배치시키고 실제 병소에 맞게 최종적인 수정을 통해 최적화 과정을 마치도록 하였다. 이 과정을 가상 표적에 대해 수행한 결과 뛰어난 결과를 보이진 않았으나 회전중심점에 대한 간단한 변화만으로 만족할 만한 결과를 나타내었다. 이는 직접적인 수술에 사용될 수는 없을지라도 수술계획을 함에 있어 최적화 과정의 시작점(Starting Point)으로 받아들이기에 만족할 만한 결과이다.

  • PDF

전자포탈영상을 이용한 다엽시준기의 정도관리 (Quality Assurance of Multileaf Collimator Using Electronic Portal Imaging)

  • 진호상;;최보영;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.151-160
    • /
    • 2003
  • 삼차원 입체조형방사선치료나 세기조절방사선치료와 같은 다엽시준기(Multileaf Collmator, MLC)를 이용하는 보다 복잡한 방사선 치료 기술은 다엽시준기의 위치 및 운동의 검증의 중요성을 증가시키고 있다. 이러한 다엽시준기의 검증은 신뢰성과 그동안 축척된 경험적 검증능력으로 인하여 주로 필름을 가지고 수행되어왔다. 그러나 전자포탈영상장치(Electornic Portal Imaging Device, EPID)의 사용의 편이성과 디지털 영상 제공 능력은 낮은 임상편이성, 효율성, 비용대 수익률에도 불구하고 정기적인 정도확립(Quality Assurance, QA)에 현실적인 필름의 대체재로 관심을 모아왔다. 본 연구에서는 EPI를 활용한 다엽시준기의 정기적인, 특히 일간 정도확립법을 개발하였다. 정기적 정도확립을 위한 전자포탈영상(Electronic Portal Imaing, EPI)의 적용가능성에 대한 검증은 방사선 조사시 동시에 획득된 필름과 다엽시준기의 제어장치에 입력한 다엽시준기의 처방과의 비교를 통해 수행되었다. 특별히 설계된 두가지 형태의 시험형(test pattern)이 영상 획득 및 비교에 적용되었다. 정성적인 온라인 육안 검증과 함께 윤곽 검출 알고리듬을 이용한 정량적인 오프라인 분석이 검증 절차에 이용되었다. 결론적으로, 본 연구에서 개발된 EPI를 이용한 다엽시준기의 일간 정도확립법은 필름의 정확도를 가지고 편리하게 수행될 수 있었다.

  • PDF

방사선치료시 최적의 빔 위치와 크기 결정 (The Determination of Optimum Beam Position and Size in Radiation Treatment)

  • 박정훈;서태석;최보영;이형구;신경섭
    • 한국의학물리학회지:의학물리
    • /
    • 제11권1호
    • /
    • pp.49-57
    • /
    • 2000
  • 방사선 치료에 따른 방사선량 최적화 문제를 풀기 위한 새로운 방법이 제시되었다. 기존의 2차원 치료계획과는 달리 3차원 문제에서는 모든 조건이 훨씬 복잡하고 관련된 변수도 많아지기 때문에 문제를 해결하기가 쉽지 않다. 본 연구에서는 3차원 선량최적화 문제를 접근하는데 있어서, 해가 존재할 수 있는 범위를 줄여주고, 중요한 파라미터들을 미리 구해주어서 치료계획에 관련된 변수를 줄이는 방법을 연구하였다. 먼저 선형가속기와 환자좌표계사이의 좌표변환을 이용하여 두부 내의 중요기관을 피하는 빔 위치를 찾았다 그리고 임의의 빔 위치에 대해 병소를 완전히 감싸는 빔 크기와 콜리메이터 회전각을 구하였다. 그 결과 가능한 빔 위치를 줄여줄 수 있었고, 빔 크기와 회전각에 대한 의존성을 없앨 수 있었다. 따라서 고려해야할 변수의 조합이 크게 줄어들게 되었고, 목적함수를 이용한 선량최적화에 있어서 최소한의 변수로만 계산이 가능하게 되었다. 위의 결과를 이용하여 임상에 널리 쓰이는 2차원 방사선치료계획의 선량최적화 문제를 해결하였다. 선량기울기, 중요기관의 선량, 선량분포 균일도를 조합한 목적함수를 최소화하는 최적해를 step search 방법을 이용하여 구하였다. 그리고 이 최적해를 이용한 선량분포로부터 새로운 방법에 의한 선량최적화의 가능성을 확인할 수 있었고, 후속 연구를 통하여 상용 방사선 치료계획 시스템에 적용함으로써 임상에 쓰일 수 있을 것으로 사료된다.

  • PDF