• 제목/요약/키워드: Collimator

검색결과 496건 처리시간 0.022초

항공용 카메라 전방운동 보상기능의 실험실 입증방안 (Laboratory Test Method for the Forward Motion Compensation of Airborne Camera)

  • 송대범;윤용은
    • 한국군사과학기술학회지
    • /
    • 제15권4호
    • /
    • pp.507-512
    • /
    • 2012
  • Image blurring in airborne camera can be prevented through timely actuation of LOS(Line of Sight) into the opposite direction to the aircraft advancement, i.e. FMC(Forward motion compensation). Performance verification of FMC requires installation of camera to the aircraft. However, in many ways the verification process has little choice but to be implemented in the laboratory. In this paper verification method of FMC performance in the laboratory is introduced. With collimator target installed in the known reference position image obtained by actual mission plan naturally displays image blurring as well as LOS displacement by FMC effect. Through comparison of the amount of those image blurring and LOS displacement to the equivalent image distortion expected by the application of the FMC reference command can the performance be verified. In this paper we propose a new verification method of FMC performance in laboratory along with generalized solution of FMC reference command, and assess the validity of our proposition.

HCM(hollow cathode magnetron sputtering)방식으로 증착한 titanium 박막의 특성연구

  • 최효직;고대홍;최시영;최승만
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.63-63
    • /
    • 2000
  • Deep submicron device contact hole에서의 bottom step coverage의 향상 및 SALICIDE공정의 필요성에 의해 collimated sputtering 및 ionized sputtering 등의 다양한 증착방법이 연구되어왔다. 반도체소자의 고집적화 및 미세화에 따라서 기존의 증착방법보다 더 높은 throughput을 가진 새로운 증착방법의 필요성이 대두되고 있다. Collimated sputtering방식으로 증착한 박막의 경우에는 증착속도가 느리고 collimator의 사용기간에 따른 공정조건의 변화가 단점으로 작용하였고 새로이 ionzied sputtering방식이 개발되었다. ionzied sputtering방식은 증착되는 금속 입자를 이온화시키고 기판에 바이어스를 걸어서 증착되는 입자의 방향성 및 증착속도의 향상을 얻을 수 있었다. 하지만 고집적도가 더욱 증가함에 따라서 더 높은 박막의 증착속도, bottom step coverage의 향상, 방향성의 향상과 더불어 증착되는 입자의 이온화 율의 증가 및 기존의 증착방식에 의한 박막보다 향상된 물성을 가진 박막증착의 필요성에 의해 hollow cathode magnetron sputtering방식이 연구되었다. HCM방식으로 titanium 박막을 증착하여 collimated sputtering 및 ionize sputtering 방식으로 증착한 titanium 박막과 물성을 비교해서 증착방식에 따른 박막물성의 차이를 연구하였다. 증착전에 기판온도는 30$0^{\circ}C$를 유지하였고 base pressure는 5.0$\times$10-9torr, working pressure는 5.7m torr로 유지하였다. power는 30kW를 가하여 50nm두께의 titanium박막을 증착하였다. 증착된 박막의 미세구조는 TEM 및 XRD로 분석하였다. HCM방식으로 증착한 titanium박막은 5nm두께의 비정질 층이 관찰되었고 ionized sputtering방식으로 증착한 titatnium박막에서 나타나는 것으로 보고된 silicon (002)와 titanium (0002) eledtron diffraction spot사이의 (10-10)spot은 관찰되지 않았다. 박막은 크고 작은 grain의 연속적 분포를 가졌고 HCM방식으로 증착한 titanium박막의 in-plane grain size가 다른 증착방식으로 증착한 박막에 비해 크게 관찰됨을 Plan-view TEM 분석을 통해서 확인되었다.

  • PDF

DESIGN AND APPLICATION OF A SINGLE-BEAM GAMMA DENSITOMETER FOR VOID FRACTION MEASUREMENT IN A SMALL DIAMETER STAINLESS STEEL PIPE IN A CRITICAL FLOW CONDITION

  • Park, Hyun-Sik;Chung, Chang-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.349-358
    • /
    • 2007
  • A single-beam gamma densitometer is utilized to measure the average void fraction in a small diameter stainless steel pipe under critical flow conditions. A typical design of a single-beam gamma densitometer is composed of a sealed gammaray source, a collimator, a scintillation detector, and a data acquisition system that includes an amplifier and a single channel analyzer. It is operated in the count mode and can be calibrated with a test pipe and various types of phantoms made of polyethylene. A good average void fraction is obtained for a small diameter pipe with various flow regimes of the core, annular, stratified, and bubbly flows. Several factors influencing the performance of the gamma densitometer are examined, including the distance between the source and the detector, the measuring time, and the ambient temperature. The void fraction is measured during an adiabatic downward two-phase critical flow in a vertical pipe. The test pipe has an inner diameter of 10.9 mm and a thickness of 3.2 mm. The average void fraction was reasonably measured for a two-phase critical flow in the presence of nitrogen gas.

Performance evaluation of noise reduction algorithm with median filter using improved thresholding method in pixelated semiconductor gamma camera system: A numerical simulation study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.439-443
    • /
    • 2019
  • To improve the noise characteristics, software-based noise reduction algorithms are widely used in cadmium zinc telluride (CZT) pixelated semiconductor gamma camera system. The purpose of this study was to develop an improved median filtering algorithm using a thresholding method for noise reduction in a CZT pixelated semiconductor gamma camera system. The gamma camera system simulated is a CZT pixelated semiconductor detector with a pixel-matched parallel-hole collimator and the spatial resolution phatnom was designed with the Geant4 Application for Tomography Emission (GATE). In addition, a noise reduction algorithm with a median filter using an improved thresholding method is developed and we applied our proposed algorithm to an acquired spatial resolution phantom image. According to the results, the proposed median filter improved the noise characteristics compared to a conventional median filter. In particular, the average for normalized noise power spectrum, contrast to noise ratio, and coefficient of variation results using the proposed median filter were 10, 1.11, and 1.19 times better than results using conventional median filter, respectively. In conclusion, our results show that the proposed median filter using improved the thresholding method results in high imaging performance when applied in a CZT semiconductor gamma camera system.

프레넬 렌즈를 이용한 항공장애등 광학계 최적 설계 (Optimization of the Optical System for an Aircraft Warning Light Using a Fresnel Lens)

  • 김종태;박현준
    • 한국광학회지
    • /
    • 제32권1호
    • /
    • pp.15-21
    • /
    • 2021
  • 본 논문에서는 LED 광원 모듈과 시준용 프레넬 렌즈를 이용하여 항공기 장애등 광학 시스템을 설계하였다. 설계된 광학계는 국토 교통부 항공기 경고등의 수직 양각 중심 광도 20,000 cd와 발산각 광도 규격 조건을 만족시키기 위해 프레넬 렌즈를 모듈별로 설계하였다. 또한 LED 광원 모듈과 프레넬 렌즈의 위치와 기울기를 조정하여 광학 시스템을 최적화하였으며, 이렇게 설계된 광학계의 배광 특성을 분석하고 비교하여 최적의 성능을 가진 항공기 경고등 광학계를 설계하였다.

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

Development and evaluation of a compact gamma camera for radiation monitoring

  • Dong-Hee Han;Seung-Jae Lee;Hak-Jae Lee;Jang-Oh Kim;Kyung-Hwan Jung;Da-Eun Kwon;Cheol-Ha Baek
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2873-2878
    • /
    • 2023
  • The purpose of this study is to perform radiation monitoring by acquiring gamma images and real-time optical images for 99mTc vial source using charge couple device (CCD) cameras equipped with the proposed compact gamma camera. The compact gamma camera measures 86×65×78.5 mm3 and weighs 934 g. It is equipped with a metal 3D printed diverging collimator manufactured in a 45 field of view (FOV) to detect the location of the source. The circuit's system uses system-on-chip (SoC) and field-programmable-gate-array (FPGA) to establish a good connection between hardware and software. In detection modules, the photodetector (multi-pixel photon counters) is tiled at 8×8 to expand the activation area and improve sensitivity. The gadolinium aluminium gallium garnet (GAGG) measuring 0.5×0.5×3.5 mm3 was arranged in 38×38 arrays. Intrinsic and extrinsic performance tests such as energy spectrum, uniformity, and system sensitivity for other radioisotopes, and sensitivity evaluation at edges within FOV were conducted. The compact gamma camera can be mounted on unmanned equipment such as drones and robots that require miniaturization and light weight, so a wide range of applications in various fields are possible.

Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study

  • Youngjin Lee;Chanrok Park
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4652-4659
    • /
    • 2022
  • Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.

Ebert-Fastie spectrograph using the Transformable Reflective Telescope kit

  • Ahn, Hojae;Mo, Gyuchan;Jung, Hyeonwoo;Choi, Junwhan;Kwon, Dou Yoon;Lee, Minseon;Kim, Dohoon;Lee, Sumin;Park, Woojin;Lee, Ho;Park, Kiehyun;Kim, Hyunjong;Pak, Soojong
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.40.4-40.4
    • /
    • 2020
  • Kyung Hee university invented the Transformable Reflective Telescope (TRT) for optical experiment and education. The TRT kit can transform into three optical configurations from Newtonian to Cassegrain to Gregorian by exchanging the secondary mirror. We designed the Ebert-Fastie spectrograph as an extension of the TRT kit. The primary mirror of the TRT kit serves as both collimator and camera lens, and the reflective grating as the dispersing element is placed along the optical axis of the primary mirror. We designed and fabricated the grating holder and the source units using 3D printer. Baffle was also fabricated to suppress the stray light, which was reduced by 83%. The spectrograph can observe the optical wavelength range (4000Å~7000Å). Measured resolving power (R=λ/Δλ) was ~700 with slit width of 0.18mm. The spectrograph is optimized for f/24, and the spectral pixel scale is 0.49Å/pixel with Canon 550D detector. We present the sample spectra of discharged Ne, Ar and Kr gases. The flexible setting and high performance make this spectrograph a useful tool for education and experiment.

  • PDF

Optimal Design of a Coudé Mirror Assembly for a 1-m Class Ground Telescope

  • Jaehyun Lee;Hyug-Gyo Rhee;Eui Seung Son;Jeon Geon Kang;Ji-Young Jeong;Pilseong Kang
    • Current Optics and Photonics
    • /
    • 제7권4호
    • /
    • pp.435-442
    • /
    • 2023
  • These days, the size of a reflective telescope has been increasing for astronomical observation. An additional optical system usually assists a large ground telescope for image analysis or the compensation of air turbulence. To guide collimated light to the external optical system through a designated path, a coudé mirror is usually adopted. Including a collimator, a coudé mirror of a ground telescope is affected by gravity, depending on the telescope's pointing direction. The mirror surface is deformed by the weight of the mirror itself and its mount, which deteriorates the optical performance. In this research, we propose an optimization method for the coudé mirror assembly for a 1-m class ground telescope that minimizes the gravitational surface error (SFE). Here the mirror support positions and the sizes of the mount structure are optimized using finite element analysis and the response surface optimization method in both the horizontal and vertical directions, considering the telescope's altitude angle. Throughout the whole design process, the coefficients of the Zernike polynomials are calculated and their amplitude changes are monitored to determine the optimal design parameters. At the same time, the design budgets for the thermal SFE and the mass and size of the mount are reflected in the study.