256 다중 검출기 전산화단층촬영에서 두개부 전용 팬톰을 이용한 분해능 파라메터와 재구성 필터의 영상 평가 (Image Evaluation of Resolution Parameter and Reconstitution Filter in 256 Multi Detector Computed Tomography by Using Head Phantom)

  • 구본승;성열훈
    • 한국콘텐츠학회논문지
    • /
    • 제11권12호
    • /
    • pp.814-821
    • /
    • 2011
  • 256 다중 검출기 전산화단층촬영 (multi detector computed tomography, MDCT)에서 두개부 전용 팬톰을 이용하여 분해능 파라메터와 재구성 필터의 영상 품질을 평가하고자 하였다. 사용한 장비는 256 MDCT 을 사용하였으며 philips system head phantom을 이용하여 Extended Brilliance Workspace에서 영상의 질 평가를 측정하였다. 장비에서 지원하고 있는 분해능 파라메터와 재구성 필터가 화질에 미치는 영향을 알아보기 위해서 검사조건을 $512{\times}512$ matrix, $128{\times}0.625$ mm beam collimation, 120 kVp, 250 mAs, 0.5 sec, 250 mm field of view (FOV), 절편 두께와 절편 간격은 5 mm, 1.0 pitch로 동일하게 적용하였다. 분해능 파라메터은 'Standard', 'High', 'Ultrahigh'로 구분하여 적용하였으며, 재구성 필터는 'A', 'B', 'C', 'D', 'UA', 'UB', 'UC' 등으로 바꿔가면서 영상을 재구성하여 노이즈, 균일도, 직선성, 변조전달함수 (modulation transfer function, MTF)의 50%와 10%를 측정하였다. 그 결과 'High' 분해능은 균일도, 직선성, MTF 50%와 10%에서 우수하였다. 'UA', 'UB' 재구성 필터는 균일도와 노이즈 평가에서 양호했으며 'C'재구성 필터는 직선성과 MTF 50%와 10%에서 양호하였다.

파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측 (Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring)

  • 김영수;박진형;조화연;김재현;권흥록;서희;박세환;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.1-9
    • /
    • 2015
  • 콤프턴 카메라는 검출 신호의 동시성 판단을 기반으로 한 전자적 집속방식을 이용하기 때문에, 기존의 물리적 집속기를 이용하는 감마선 영상 장비의 가시영역이 좁고 투과력이 높은 고에너지 감마선에 적용하기 어렵다는 한계를 극복할 수 있다. 특히 대면적의 콤프턴 카메라는 절대 검출 효율이 높아 영상 장비의 운반이 요구되지 않는 대규모 공정 시설내 핵물질의 모니터링용으로 매우 적합하다. 본 연구팀은 한국원자력연구원에서 개발 중인 파이로 시험 공정 시설에서의 안전조치 수립을 위해 대면적 콤프턴 카메라를 적용하고자 한다. 대면적 콤프턴 카메라를 구성하는 대면적의 검출기는 그 형태나 구성 방식에 따라 에너지 분해능이나 위치 분해능이 달라질 수 있다. 이는 콤프턴 영상의 질에 직접적으로 영향을 미치므로, 본 연구에서는 전산모사를 통해 그 영향을 예측하여 대면적 검출기의 설계 방향을 결정하였다. 또한 한국원자력연구원으로부터 파이로 시험 공정 시설의 정보를 전달받아 전산모사를 수행하였고, 여러 계측 환경에 대해 대면적 콤프턴 카메라의 성능을 예측하여 보았다. 그 결과 대면적 검출기는 에너지 분해능 측면에서의 손실을 최소화 할 수 있도록 구성하여야 한다는 결론을 얻었으며, 에너지 분해능 10%, 위치 분해능 7 mm 정도 성능의 검출기를 이용하여 콤프턴 카메라를 구성할 경우 1 m 거리에 위치한 감손우라늄 선원을 영상 해상도 16.3 cm(각도 분해능 $9.26^{\circ}$)으로 영상화할 수 있음을 확인하였다.

디지털 심혈관조영장치의 기하학적 특성에 따른 선량 감소 (Reduction of Radiation Dose according to Geometric Parameters from Digital Coronary Angiography)

  • 강영한;조평곤
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.277-284
    • /
    • 2013
  • 심혈관 촬영 시 선량감소를 위해 실무자가 조절 가능한 기하학적 특성을 살펴보고, 각 특성에 따른 유효선량을 비교해 보았다. 인체 모형 팬텀을 이용하여 투시촬영과 영화촬영을 시행하였고, 선량의 측정은 심혈관 장치의 DAP meter를 이용하여 DAP 값을 유효선량으로 환산하였다. 먼저 영화촬영은 투시촬영에 비해 기하학적 특성 전반에 걸쳐서 선량이 약 6-7배 높았다. FPS mode에 따른 선량은 FPS를 낮게 설정할수록 선량이 70%까지 감소하였다. 선관 각도에 따른 선량은 LAO $45^{\circ}$+Caudal $30^{\circ}$이 가장 높게 측정되었고, 조사야 조절장치를 많이 적용할수록 선량은 감소하였다. X-선관과 영상증배관의 거리가 10 cm 멀어질수록 투시촬영과 영화촬영에서 각각 선량이 25-35%까지 증가하였다. FOV가 확대될수록 선량이 1.21-2배 증가하였고, 테이블과 영상증배관 거리가 10cm 멀어질수록 선량은 1.11-1.25배 까지 증가하였다. 따라서 본 연구에서 실험한 기하학적 특성인 FPS mode, 선관 각도, 조준기, 선관과 영상증배관 거리, 테이블과과 영상증배관 거리, FOV 영상 확대 등은 중재적 시술 시 실무자가 수시로 조절 가능한 인자이며, 각 특성에 따라 선량 감소 효과를 기대할 수 있다.

한국형 중이온 가속기 RAON의 의생물 연구시설 탄소 빔 노즐에 대한 Monte Carlo 시뮬레이션 (Monte Carlo Simulation of the Carbon Beam Nozzle for the Biomedical Research Facility in RAON)

  • 배재범;조병철;곽정원;박우윤;임영경;정현태
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.12-17
    • /
    • 2015
  • 본 연구에서 한국형 중이온 가속기 RAON에서의 의생물 실험을 위하여 요구되는 빔 조건을 만족할 수 있도록 Monte Carlo 전산모사를 통한 노즐 설계를 최적화하고자 하였다. 의생명 실험을 위한 빔 조건으로 최대 조사면 크기, 선량균일도 그리고 빔 오염도의 특정 조건을 만족하는 $C^{12}$ 빔 생산이 요구되었다. 이때 최적화된 빔 노즐 설계를 위하여 Monte Carlo 시뮬레이션인 GEANT4 toolkit이 사용되었다. $15{\times}15cm^2$ 이상의 빔 조사면 크기와 3% 이내의 선량 균일도 그리고 전체 선량의 5% 보다 낮은 빔 오염도를 기본적인 조건으로 설정 되었다. 조사면 크기는 쌍극자 자석에 의해서 빔의 각도를 기울여 원형으로 회전하면서 쌍극자 자석의 아래쪽에 위치한 산란판의 두께를 조정하여 최적화 하였다. 빔 스캐닝 각도와 산란판의 두께는 Monte Carlo 시뮬레이션 분석에 의해서 각각 $0.5^{\circ}$와 0.05 cm로 최적의 값을 나타내었다. 선량 균일도와 최대 조사면 크기를 만족하기 위하여 static과 scanning beam을 복합하는 기술을 이용한 새로운 빔 전달 방법을 소개하였다. 중앙 고정용 빔과 빔 축으로부터 $0.5^{\circ}$ 경사각을 가지고 회전하는 빔과 경사각이 없이 바로 들어오는 빔을 조합하여 선량균일도가 1.1%와 빔 조사면의 최대크기가 $15{\times}15cm^2$가 되는 것을 확인하였다. 빔 오염도는 $C^{12}$ 이온과 다른 입자들에 의해서 전달된 흡수선량의 비율로 나타내었다. 물등가 깊이(water equivalent depth) 5 cm에서 17 cm 사이에서의 빔 오염도는 전체 선량에서의 2.5% 미만임을 확인하였으며 이와 같은 결과를 바탕으로, 본 연구에서는 의생명 실험을 위하여 요구되는 빔 조건을 만족하는 노즐 구조를 설정할 수 있었다.

보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究) (Survery on Business of the Departments of Radiology in Health Centers)

  • 최종학;전만진;허준;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

방사광 X-선을 이용한 고해상도 영상획득과 응용 (Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.51-58
    • /
    • 2001
  • 물질의 X-선 흡수도에 의해 영상을 얻는 일반 X-선 시스템과 달리 방사광 X-선은 위상이 일치하고 평행하며 진동방향이 일치하는 특성들을 이용하면 고 분해능, 고 대조도의 투사영상을 얻을 수 있다. 국내에서는 포항 방사광 가속기 연구소에 최근 건설된 5C1 빔라인에 미세구조 X-선 영상 획득을 위한 영상시스템을 구축하여 여러 기초 생물, 의학연구분야의 고 분해능 영상획득이 가능하게 되었다. 방사광 X-선을 이용하여 얻은 고 해상도 투사영상들 및 단층 재구성 영상들을 일반 X-선을 사용하는 유방찰영시스템, 치아 X-선 찰영시스템, 전신측정용 CT 시스템에서 각각 획득한 동일한 대상의 영상들과 비교하였다. 실험에 사용한 방사광 X-선은 6 ~30 keV 사이의 연속적인 에너지 분포를 가지며, 실험의 대상에 따라서 실리콘웨이퍼 필터들을 사용하여 빔의 세기와 에너지 스펙트럼 분포를 조절하여 사용하였다. 실험 대상 물체를 통과한 방사광 X-선의 투사영상은 형광판 (CdWO$_4$ scintillator)과 반응하여 가시광선으로 바뀐 후, 금도금된 거울을 통해 90$^{\circ}$ 반사되어 CCD 카메라로 획득하며, 이러한 디지털 영상정보는 PC로 전송되어 저장된다. 방사광 X-선의 공간 분해능 특성은 X-선 시험패턴(25 $\mu$m)과 초 고해상도 패턴 (13.5 $\mu$m)을 방사광 X-선 영상획득시스템 과 일반 X-선을 사용하는 유방촬영시스템에서 획득하여 분석하였다. 영상획득 실험대상으로는 일반 구조물로 커패시터, 생체조직으로 성인치아, 유아치아, 생쥐 척추뼈 및 유방암조직을 대상으로 실험하였다. 단층영상은 각각의 샘플을 0.72$^{\circ}$ 간격으로 180$^{\circ}$ 회전시켜 250개의 투과영상들로부터 재구성한 후 컴퓨터 단층촬영기에서 얻은 영상과 비교하였다. 포항 방사광가속기연구소 5C1 빔라인에 간단하고, 경제적인 방사광 X-선 영상획득시스템을 성공적으로 구축할 수 있었고, 획득한 투사 영상과 재구성한 단층영상을 기존 X-선을 사용한 시스템으로 획득한 단층영상들과 분해능, 대조도의 특성들을 비교, 분석하였다. 방사광 X-선을 사용하여 획득한 영상들은 일반 시스템에서 얻은 영상보다 고 해상도의 영상 질을 보여주었고, 기초 의학영상 연구 측면에서 많은 정보를 제공해 주었다. 방사광 X-선을 이용한 영상획득시스템은 고 분해능과 고 대조도로 미세구조의 상세한 의학영상을 얻기 위한 유용한 방법으로 활용될 수 있을 것으로 기대된다. 향후 해부학적, 병리학적 및 임상학적 의료영상 분야에 효과적으로 응용하기 위하여 X-선 선량 정량 분석과 수치적 영상 해석연구가 계속되어야 할 것으로 사료된다.

  • PDF

64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소 (Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols)

  • 김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.299-306
    • /
    • 2009
  • MDCT의 시간분해능 향상과 등방성 해상능(isotrophic resolution) 영상의 획득, 그리고 지능적인 심전도 동조를 바탕으로 하여 심혈관 질환의 효과적인 진단검사로 인정받고 있는 후향적 심전도 동조화(retrospective ECG gating) 하의 coronary CT angiography는 상대적으로 많은 환자선량을 제공함으로 인해 우수한 진단방법으로서의 장점을 반감시키고 있다. 이에 각 장치 제조사에서는 환자선량을 감소시키는 방법의 연구가 활성화되어 왔으며, 이의 일환으로 지능적인 cardiac dose modulation 기술과 전향적 심전도 동조화(prospective ECG gating)를 사용한 sequential scan이 도입되고 있다. 이에 본 연구에서는 64 채널 MDCT에서 54 kg, 163 cm인 여성 인체모형팬텀을 대상으로 하고 형광유리선량계를 사용하여 후향적 심전도 동조화 하의 coronary CT angiography 프로토콜에서 환자선량의 정량적 평가와 환자선량 감소를 위해 본원에서 선택적으로 적용하고 있는 5가지 검사 프로토콜을 적용하였을 경우의 effective dose와 중요 부위의 organ dose를 측정 비교하여 다음과 같은 결과를 얻었다. 1) Dose modulation없이 120 kVp와 210 mAs의 노출조건으로 retrospectively ECG gated helical scan으로 시행한 conventional coronary CT angiography 프로토콜의 effective dose는 17.8 mSv였으며, 심장의 organ dose는 103.8 mGy였다. 2) 관전압을 120 kVp에서 100 kVp로 낮추었을 경우 effective dose는 11.0 mSv로 conventional coronary CT에 비해 38.2%가 감소하였으며, 심장은 67.3 mGy로 45.2%가 감소하였다. 3) Cardiac dose modulation을 적용한 경우 effective dose는 13.3 mSv로 conventional coronary CT에 비해 25.3%가 감소하였으며, 심장은 80.0 mGy로 22.9%가 감소하였다. 4) 100 kVp의 저관전압과 cardiac dose modulation을 적용한 경우 effective dose는 8.1 mSv로 conventional coronary CT angiography에 비해 54.5%가 감소하였으며, 심장은 49.5 mGy로 52.3%가 감소하였다.

  • PDF