• 제목/요약/키워드: College building

검색결과 1,655건 처리시간 0.028초

The capacity loss of a RCC building under mainshock-aftershock seismic sequences

  • Zhai, Chang-Hai;Zheng, Zhi;Li, Shuang;Pan, Xiaolan
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.295-306
    • /
    • 2018
  • Reinforced concrete containment (RCC) building has long been considered as the last barrier for keeping the radiation from leaking into the environment. It is important to quantify the performance of these structures and facilities considering extreme conditions. However, the preceding research on evaluating nuclear power plant (NPP) structures, particularly considering mainshock-aftershock seismic sequences, is deficient. Therefore, this manuscript serves to investigate the seismic fragility of a typical RCC building subjected to mainshock-aftershock seismic sequences. The implementation of the fragility assessment has been performed based on the incremental dynamic analysis (IDA) method. A lumped mass RCC model considering the tri-linear skeleton curve and the maximum point-oriented hysteretic rule is employed for IDA analyses. The results indicate that the seismic capacity of the RCC building would be overestimated without taking into account the mainshock-aftershock effects. It is also found that the seismic capacity of the RCC building decreases with the increase of the relative intensity of aftershock ground motions to mainshock ground motions. In addition, the effects of artificial mainshock-aftershock ground motions generated from the repeated and randomized approaches and the polarity of the aftershock with respect to the mainshock on the evaluation of the RCC are also researched, respectively.

AUTOMATIC AS-IS BIM EXTRACTION FOR SUSTAINABLE SIMULATION OF BUILT ENVIRONMENTS

  • Chao Wang;Yong K. Cho
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.47-51
    • /
    • 2013
  • Existing buildings now represent the greatest opportunity to improve building energy efficiency. Building performance analysis is becoming increasingly important because decision makers can have a better visualization of their building's performance and quickly make the solution for improving building energy efficiency and reducing environmental impacts. Nowadays, building information models (BIMs) have been widely created during the design phase of new buildings, and it can be easily imported to third party software to conduct various analyses. However, a BIM is not always available for all existing buildings. Even if a BIM is available during the design and construction phases, it is very challenging to keep updating it while a building is aged. A manual process to create or update a BIM is very time consuming and labor intensive. A laser scanning technology has been a popular tool to create as-is BIM. However it still needs labor-intensive manual processes to create a BIM out of point clouds. This paper introduces automatic as-is simplified BIM creation from point clouds for energy simulations. A framework of decision support system that can assist decision makers on retrofits for existing buildings is introduced as well. A case study on a residential house was tested in this study to validate the proposed framework, and the technical feasibility of the developed system was positively demonstrated.

  • PDF

대학의 실내 라돈가스 농도의 변화 평가 (Assesment of Indoor Radon Gas Concentration Change of College)

  • 박훈희;정의환;김학재;이주영;유광열
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.127-134
    • /
    • 2017
  • 본 연구는 실내 라돈 가스의 농도를 낮추기 위한 방법을 찾기 위해 건물의 준공연도, 건물의 용적, 환기 세 가지 변수에 따른 실내 라돈 농도를 비교, 측정하여 그 영향을 알아보고자 한다. 측정은 1973년에 건축이 되었고, 2011년에 증축이 된 건물의 6층을 대상으로 용적이 서로 다르고 준공연도가 1973년과 2011년인 6개의 강의실을 측정하였다. 준공연도에 따른 라돈농도를 비교하기 위해 4개의 강의실을 선정하였고, 용적에 따른 라돈농도를 비교하기 위해 준공연도가 같고 용적이 다른 강의실을 선정하였고, 환기에 따른 라돈농도를 비교하기 위해 6개의 강의실의 폐쇄와 환기를 시행하였다. 결과적으로 준공연도에 따른 라돈농도는 최근에 지어진 건물에서 라돈농도가 최대 4배 높게 나타났으며, 용적에 따른 라돈농도는 용적이 작을수록 높게 나타났다. 환기에 따른 라돈농도의 변화는 폐쇄 시보다 환기를 할 경우 약 80%의 감소율을 보였다. 특히, 준공연도가 최근이면서 용적이 작을수록 라돈농도가 높게 검출되었고, 세 가지 변수 중 환기가 라돈농도 감소에 가장 큰 영향을 끼쳐 라돈에 의한 피폭감소 효과를 기대할 수 있을 것으로 사료된다.

국내 건축자재에 함유된 석면의 함량에 대한 X-선회절분석 연구 (Asbestos Determination of Some Domestic Building-Materials Using X-ray diffraction)

  • 황진연;이효민;오지호;박기남
    • 한국광물학회지
    • /
    • 제24권2호
    • /
    • pp.119-131
    • /
    • 2011
  • 대표적인 일부 건축자재의 석면 함량을 일본공업표준법 (JIS)에 따른 X-선회절분석으로 측정하였고, 분석과정에서의 광물학적 성분변화와 문제점을 검토하였다. 국내의 슬레이트, 벽재, 천장재의 대표적인 건축자재에 대해 석면 함량을 정량한 결과, 슬레이트 시료가 6.87~6.93%의 온석면을 함유하여 가장 많은 석면을 함유하고 있는 것으로 분석되었다. 분석된 다른 건축자재들에서도 1.35~3.98%의 범위로 다양한 양의 온석면이 포함되어 있는 것으로 분석되었다. 이번 연구에서 국내에서 처음으로 일부 건축자재의 석면 함량에 대한 X-선회절방법에 의한 분석결과를 제시하였으며, 이런 방법을 통하여 국내에서 최근에 개정된 규정(노동부 산업안전보건법 제2007-26호)에서 규정한 석면의 허용기준량 0.1% 함량을 평가하는데 효과적인 것으로 나타났다. 일부 시료에서 온석면과 함께 투각섬석이 소량 수반되고 있음이 나타났으나, 이들의 결정형태와 그 함량과 지질학적 산출상태 등으로 보아, 석면 활용의 목적으로 첨가한 것이 아니고 온석면에 본래 수반되었던 볼순광물로 나타난 것으로 생각된다. X-선회절분석으로 석면상과 비석면상의 구분이 어렵기 때문에 형태를 관찰할 수 있는 광학현미경과 전자현미경의 보조적인 관찰도 필요한 것으로 나타났다. 이번에 사용한 X-선회절분석 방법에서는 가열처리와 산처리에 의한 소실율이 많아 석면의 농집도가 높은 건축자재 시료에 가장 효과적인 것으로 나타났다.

보성전문학교 도서관(1935~37)의 건축적 연원 탐구 (Tracing the Architectural Origin of the Bosung College Library (1935~37))

  • 김현섭
    • 건축역사연구
    • /
    • 제21권4호
    • /
    • pp.47-58
    • /
    • 2012
  • The purpose of this paper is to trace the architectural origin of the Bosung College Library (1935~37), which is currently used as Graduate School Building of Korea University. So far, numerous books have repeatedly described that the library was modelled on a Duke University library, but without any serious consideration. Through literature review, field-trip and archives investigation, this research discovered new critical facts concerning the origin of the building. First, Dong-Jin Park, the architect for Bosung College, saw a photograph of the Duke library in a Duke University catalog possessed by Chun Suk Auh, Professor of the college at that time. Second, the Duke library that he saw in the catalog, which might possibly be Bulletin of Duke University (Feb. 1931), is certainly the present Perkins Library (1930) in Duke University West Campus. Third, the architect probably referred not only to the library but also to other Duke buildings such as School of Medicine and The Union, of which photographs were also published impressively in the Bulletin. Although the Bosung College Library was inspired by the Duke buildings, however, it is undoubtedly a creative design work by the architect Park. Arguably, these findings broaden our view of Korean architectural history in the modernization period, and it is more than a confirmation of just one building's origin.

3kW 건물일체형 태양광발전시스템의 출력특성 (The Output Characteristics of 3kW BIPV System)

  • 김지훈;김평호;임양수;조금배;백형래;오금곤
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.471-474
    • /
    • 2006
  • BIPV(Building Integrated PV) system can expect dual effects that reduce expenses for establishment of PV system by adding new function as outer covering material of building expect producing the electricity. But, there are many generation differences according to the exterior environmental facts(solar cell away, design and installation condition of interactive inverter system) Therefore, it is difficult to optimum design. Consequently in advance design system, we experiment 3kW BIPV(Building Integrated PV) generation. We concrete PV system efficient application of variable. BIPV system that is proposed in this paper, was established in Solar Energy research center of Chosun University, composed with system. This research is a basic study for application of building integrated photovoltaic system for builing.

  • PDF

Development and evaluation of a pediatric nursing competency-building program for nursing students in South Korea: a quasi-experimental study

  • Koo, Hyun Young;Lee, Bo Ryeong
    • Child Health Nursing Research
    • /
    • 제28권3호
    • /
    • pp.167-175
    • /
    • 2022
  • Purpose: The present study aimed to develop and examine the effectiveness of a pediatric nursing competency-building program for nursing students. Methods: This was a quasi-experimental study with a nonequivalent control group pretest-posttest design conducted between October and December 2021. The participants included 40 nursing students (20 each in the experimental and control groups) at a university in a South Korean city. The pediatric nursing competency-building program integrated problem-based learning and simulation into clinical field practice. The experimental group participated in the program, while the control group did not. Data were analyzed using the 𝑥2 test, the independent t-test, and repeated-measures analysis of variance. Results: Pediatric nursing competency and clinical performance showed a greater increase in the experimental group than in the control group. However, the change in problem-solving ability in the experimental group was not significantly different from that in the control group. Conclusion: The pediatric nursing competency-building program effectively improved students' pediatric nursing competency and clinical performance.

Quantifying Values from BIM-projects life cycle with cloud-based computing

  • Choi, Michelle Mang Syn;Kim, Inhan
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.271-275
    • /
    • 2015
  • A variety of evaluation application and initiatives on the adoption of Building Information Modelling (BIM) have been introduced in recent years. Most of which however, focused mainly on evaluating design to construction phase-processes, or BIM utilization performances. Through studying existing publications, it is found that continuous utilization of BIM data throughout the building's life cycle is comparatively less explored or documented. Therefore, this study looks at improving this incomplete life cycle condition with the concept that accumulated BIM data should be carried forward and statistically quantified for cross comparison, in order to facilitate practitioners to better improve the projects the future. Based on this conceptual theory of moving towards a closedloop BIM building life cycle, this study explores, through existing literature, the use of cloud based computing as the means to quantify and adaptively utilize BIM data. Categorization of BIM data relations in adaptive utilization of BIM data is then suggested as a initial step for enhancing cross comparison of BIM data in a cloud environment.

  • PDF

가변전열 히트파이프의 저온 시동특성에 관한 연구 (A study on the characteristics of a frozen start up for a variable conductance heat pipe)

  • 홍성은;강환국;조광철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.339-345
    • /
    • 2006
  • This these was conducted to investigate tile characteristics of a frozen start up for a VCHP which has water as a working fluid and Nitrogen as a non-condensible gas. The tested heat pipe was made of a copper tube with the outer diameter of 12.7 mm, the length of 340 mm, and the sintered metal wick had the thickness of 0.7 mm. This experiment was conflicted under the thermal load, inclined angle and cooling conditions.

  • PDF

동적 특성을 고려한 상주 양진당의 구조 안전성 평가 (Structural Safety Evaluation of Yangjindang in Sang-ju Using Vibration Characteristics)

  • 이가윤;이성민;김시윤;이기학
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.37-44
    • /
    • 2019
  • Yangjindang house, which is located in Sang-ju province of South Korea, is one of the special Hanok structures dated back to Joseon dynasty. This study aims to examine structural safety of the Yangjindang wood frame building considering dynamic parameters such as the natural frequency and damping ratio. The numerical model of the wood frame building is implemented using Midas Gen, especially the wood joint where column and beam were connected. The behavior of the actual frame building was compared with the modeling results. In addition, structure responses such as shear force, axial force, flexural moment and deflections were calculated and compared with the allowable limits. Numerical results show that, generally, despite of some local members shear failure, Yangjindang's structural response does not exceed the limitation according to current standards.