• 제목/요약/키워드: Collector design

검색결과 243건 처리시간 0.028초

산성 전해질 기반의 전기 이중층 커패시터용 흑연 집전체의 전기화학적 안정성 평가 (Evaluation of Electrochemical Stability of Graphite Current Collector for Electric Double Layer Capacitor Based on Acid Electrolyte)

  • 박시진;안건형
    • 한국재료학회지
    • /
    • 제31권5호
    • /
    • pp.272-277
    • /
    • 2021
  • Owing to its low cost, easy fabrication process, and good ionic properties, aqueous supercapacitors are under strong consideration as next-generation energy storage devices. However, the limitation of the current collector is its poor electrochemical stability, leading to low energy storage performance. Therefore, a reasonable design of the current collector and the acidic electrolyte is a necessary, as well as interfacial engineering to enhance the electrochemical performance. In the present study, graphite foil, with excellent electrochemical stability and good electrical properties, is suggested as a current collector of aqueous supercapacitors. This strategy results in excellent electrochemical performance, including a high specific capacitance of 215 F g-1 at a current density of 0.1 A g-1, a superior high-rate performance (104 F g-1 at a current density of 20.0 A g-1), and a remarkable cycling stability of 98 % at a current density of 10.0 A g-1 after 9,000 cycles. The superior energy storage performance is mainly ascribed to the improved ionic diffusion ability during cycling.

태양열/공기열 복합 집열기를 가지는 하이브리드 히트펌프 시스템의 열성능에 관한 연구 (Study on the Thermal Performance of a Solar Assisted Heat Pump System with a Hybrid Collector)

  • 도규형;최병일;한용식;김명배;김태훈
    • 한국수소및신에너지학회논문집
    • /
    • 제27권2호
    • /
    • pp.182-191
    • /
    • 2016
  • In the present work, a solar assisted heat pump (SAHP) system with a hybrid collector was analyzed. For this, a simplified thermodynamic model was developed. Based on the proposed model, the heat transfer rate, COP, and the annual operating hour of the SAHP system were estimated. The effect of the variation of system design parameters on the performance of the system was also examined. From the results, the performance was improved with increasing the effectiveness of heat exchangers and decreasing the difference between the evaporation temperature and the outlet brine temperature of the hybrid collector loop. Finally, the performance of SAHP system with a hybrid collector was compared with that of conventional serial and parallel SAHP systems. The SAHP system with a hybrid collector was substantially better than a series system and slightly worse than a parallel system for both the yearly averaged heat transfer rate and COP. However, the annual operating hour of the SAHP system with a hybrid collector was much better than that of a parallel system.

$TiO_2/PVP$ 나노섬유의 제조 (Fabrication of axially aligned $TiO_2/PVP$ nanofibers)

  • 이세종
    • 한국결정성장학회지
    • /
    • 제17권1호
    • /
    • pp.30-34
    • /
    • 2007
  • [ $TiO_2/PVP$ ] 나노섬유의 배열을 증진시키기 위하여 콜렉터 접지방법을 변화시키면서 전기방사하였다. 한축방향의 배열을 가진 섬유를 만들기 위하여 두개의 전도성 기판을 콜렉터로 사용하여 전기방사하였다. 또한, 두축방향의 섬유배열을 하기 위하여 $90^{\circ}$ 각도로 배치된 콜렉터를 타이머로 조절하면서 방사하였다. 전기방사 시 나노섬유는 콜렉터 전극사이에서 전기장 효과에 의해 퍼지는 현상이 관찰되었다. 실험결과, 후자의 $TiO_2/PVP$ 나노섬유 경우 콜렉터에 정체된 전하의 해소로 인하여 방향성에 더 효과적이었다.

An Experimental Study on the Characteristic of the Hot Water-Air Heating Generating System with a Solar Collector

  • Rokhman, Fatkhur;Hong, Boo-Pyo;You, Jin-Kwang;Yoon, Jung-In;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.360-363
    • /
    • 2012
  • A solar air heating has low efficiency compared with the solar water heating because the heat capacity of the air is small. The heat received by solar collector plate is not fully transferred to the air and then a part of them became the losses to the environment through conduction and convection process. This research is focusing on a design of better combined multi-purposed system suggested by us and aims to secure the more efficient solar energy utilization by combining the hot water and air heating system. The result in this paper has shown that the proposed design has better thermal performance than that of the common design. Furthermore, it was found that the performance of the combined air - water heating system increases the efficiency from 30% to 35%-40%.

  • PDF

Tracepro를 활용한 이중 블라인드 광파이프 채광 시스템의 블라인드 설계 및 시스템 효율 평가 (Tracepro Simulation Design and Evaluation for the Double Blind Light Pipe Daylighting System)

  • 강은철;이의준;유성연
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.515-520
    • /
    • 2012
  • A daylighting system includes three parts; light collector, light transformer and light distributor. A DBLP(Double blind light pipe) daylighting system consists of a double blind light collector, a mirror duct type light transformer and a prism film light pipe distributor. The double blinds for a light collection are used to track the sun's altitude and azimuth movements throughout the day. Behind both sets of blinds is the light transformer, which is based on a rectangular cone shaped light duct. The light transformer was designed to efficiently deliver the light into the light pipe within a 30 degree radial spread for the efficient light into the distributor. In this study, DBLP system efficiency was simulated, evaluated and optimized by Tracepro as a popular ray trace light design simulation program. The results indicated that DBLP system efficiency evaluated a maximum 22.4% in case of Spring/Fall season solar noon time. While the overall average system efficiency in the morning and afternoon is evaluated about 10%.

Reliability Analysis for Structure Design of Automatic Ocean Salt Collector Using Sampling Method of Monte Carlo Simulation

  • Song, Chang Yong
    • 한국해양공학회지
    • /
    • 제34권5호
    • /
    • pp.316-324
    • /
    • 2020
  • This paper presents comparative studies of reliability analysis and meta-modeling using the sampling method of Monte Carlo simulation for the structure design of an automatic ocean salt collector (AOSC). The thickness sizing variables of structure members are considered as random variables. Probabilistic performance functions are selected from strength performances evaluated via the finite element analysis of an AOSC. The sampling methods used in the comparative studies are simple random sampling and Sobol sequences with varied numbers of sampling. Approximation methods such as the Kriging model is applied to the meta-model generation. Reliability performances such as the probability failure and distribution are compared based on the variation of the sampling method of Monte Carlo simulation. The meta-modeling accuracy is evaluated for the Kriging model generated from the Monte Carlo simulation and Sobol sequence results. It is discovered that the Sobol sequence method is applicable to not only to the reliability analysis for the structural design of marine equipment such as the AOSC, but also to Kriging meta-modeling owing to its high numerical efficiency.

강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구 (A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method)

  • 박형수;김철호
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.122-126
    • /
    • 2017
  • 태양열 에너지를 이용하여 단순한 형태의 공기가열식 집열기를 이용하여 공기를 가열하고 이를 활용하여 생활공간의 난방문제를 해결하기 위한 장치를 개발하는데 목적을 두고 진행되고 있다. 현 시점에서 연구는 모델로 개발한 공기가열식 태양열에너지 집열기의 크기 변화에 따른 가용한 에너지의 량을 이론적으로 산출해 보고 이를 통해 개발 시스템의 가능성을 판단하고자 한다. 본 연구에서는 공기가열식 태양열 집열기의 공기가열성능을 판단하기 위하여, 특정 크기의 태양열 집열기에 일정한 일사량을 투하하였을 때, 모델 집열기 내부에서의 열전달 특성변화와 이를 통해 생산되는 공기의 온도($^{\circ}C$)와 생산량(kg/h)을, 유한체적법(Finite Volume Method)을 적용한 범용 열유동해석(CFD) 프로그램인 영국 CHAM사의 PHOENICS(1)를 이용하여, 분석한 결과를 구하였다. 분석한 결과에서 알 수 있듯이 집열기의 크기가 ($1.2m{\times}1.1m{\times}0.19m$)의 집열기에서 알루미늄으로 제작하는 내경 0.1m의 공기 가열관을 이용하여 가열할 수 있는 공기의 온도는 약 $40.5^{\circ}C$이며 이때 생산되는 공기의 생산량은 약 $161m^3/h$으로 산출되었다. 본 모델장치는 충분히 태양의 열에너지를 이용하여 실내공간의 온도를 인간이 활동하기에 적합한 활동의 환경을 유지하는데 활용할 수 있다고 판단된다.

플래시 메모리 파일 시스템을 위한 가비지 콜렉터 설계 및 구현 (A garbage collector design and implementation for flash memory file system)

  • 김기영;손성훈;신동하
    • 정보처리학회논문지A
    • /
    • 제14A권1호
    • /
    • pp.39-46
    • /
    • 2007
  • 최근 들어 많은 임베디드 기기들이 휴대성과 성능 향상을 위해 플래시 메모리를 저장 매제로 사용하고 있다. 플래시 메모리는 일반적인 디스크와는 다른 특성과 제약 조건으로 인해 파일 시스템 설계에 있어서 여러 가지가 고려되어야 하며, 디스크와 다르게 덮어쓰기가 불가능하다. 플래시 메모리 파일 시스템은 LFS(Log-structure File System)의 형태를 가지며, 따라서 가비지 콜렉터를 사용한다. 블록을 재사용하기 위해서는 가비지 콜렉터의 역할이 크며, 가비지 콜렉터는 파일 시스템의 성능에 직접적으로 영향을 주기 때문에 플래시 메모리의 특성을 고려하여 설계해야 한다. 이에 본 논문에서는 JFFS2(Journaling Flash File System II)의 가비지 콜렉터를 개선한 플래시 메모리 파일 시스템을 제시하고, 이를 임베디드 시스템 실험 보드에서 테스트하였다. 그 결과 기존의 파일 시스템에 비해 메모리 사용률을 감소시킬 수 있었으며, 이로 인한 플래시 메모리 수명 연장, 쓰기 평준화(wear-leveling) 개선 등의 성능 향상이 나타남을 확인할 수 있었다.

공진형 컨버터를 이용한 비접촉 전력공급장치 제작 (Manufacture of contactless power supply using by resonance converter)

  • 장동욱;김형철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2208-2209
    • /
    • 2011
  • In this paper, the contactless power transfer using inductive power collector in order to apply to the vehicle such as the electric railway vehicle system is suggested and some ideas for power collector design to improve the power transfer performance are presented. This paper was presented for the transfer characteristic of power from input to output by resonance converter.

  • PDF

방사형 집수정의 적정 설계를 위한 조사 물량 제안 (A Proposal for the Number of Investigation Wells for Optimal Radial Collector Well Design)

  • 최명락;김규범
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권2호
    • /
    • pp.1-8
    • /
    • 2020
  • In general, the estimation of optimum yield for the radial collector well is determined by the empirical equation or numerical modeling, in which hydraulic conductivity of the aquifer is a main influence factor. Hydraulic conductivities of 164 soil samples collected from boreholes and horizontal wells (average length: about 50 m) installed during well construction in the Anseong stream were drawn in two-dimensional map by the Kriging method and utilized in this study. Hydraulic conductivity analyses by Representative Elementary Count (REC) indicated the average hydraulic conductivity is similar to that of the pumping test when the number of samples reaches about 1,000, which correspond to 1,000 ㎡. Pumping test was also conducted at 1 pumping well and 13 observation wells to estimate hydraulic conductivities at each observation well. REC analysis indicated that the average value of hydraulic conductivity calculated from at least four observation wells is valid as a representative value. The overall result suggested that multiple observation wells or multiple pumping-observation well systems that are located within the range of horizontal wells should be utilized to properly estimate the representative hydraulic conductivity values and the yield of a radial collector well.